• Title/Summary/Keyword: 화재 사고

Search Result 1,170, Processing Time 0.033 seconds

A Study on the Development of Smart Control Valve (스마트 컨트롤 밸브 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.6
    • /
    • pp.582-590
    • /
    • 2019
  • As Korea's low fertility and aging progress, Korea is facing a social change such as an increase of one generation by entering an aging society that has raised 14% of the population. An effective way to prevent a gas fire accident caused by an increase in one generation in an aging society is to install a control valve to forcibly shut off the gas after a set time. In this study, we developed a valve that can be opened and closed by rotating the valve left and right by transmitting power to the worm gear and the helical gear by using a motor by pressing the switch. It is easy to assemble and inspect by developing a dedicated valve that is easy to attach and detach. It was developed to enhance competitiveness by reducing cost by reducing the number of parts and product size. In addition, through endurance test, it was developed to be used for more than 9 years by repeating ON / OFF once every 12 seconds so that it can operate stably for 10,000 times for 34 hours. The instrument and PCB were designed using solid works and Altium Designer tools. Firmware development was developed in IAR Embedded Workbench environment.

A Stress Analysis for Pressure Vessel to Prevent Spontaneous Ignition of Coal Stockpile (저탄장 자연발화 방지를 위한 압력용기의 응력 해석)

  • Kim, Young In;Kim, Seung Hun;Jie, Min-Seok;Yeum, Chan Sub;Choi, Won Hyuck
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.3
    • /
    • pp.205-212
    • /
    • 2018
  • Spontaneous ignition is not only severe economic damage but also a typical plant damage caused by harmful gases generated during the fire. Because coal is porous, it causes oxygen to be absorbed in the amount of oxygen per unit weight of oxygen, resulting in low humidity and low thermal conductivity. The cause and effect of spontaneous ignition are very complex, so it is difficult to prevent it beforehand and once it is difficult to digest it, it is difficult to digest it. This study examines structural safety by conducting a structural analysis of the cooling ball system to prevent spontaneous combustion of coal stockpile plants and external pressures.

Vision-Based Fast Detection System for Tunnel Incidents (컴퓨터 시각을 이용한 고속 터널 유고감지 시스템)

  • Lee, Hee-Sin;Jeong, Sung-Hwan;Lee, Joon-Whoan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • Our country has so large mountain area that the tunnel construction is inevitable and the need of incident detection that provides safe management of tunnels is increasing. In this paper, we suggest a tunnel incident detection system using computer vision techniques, which can detect the incidents in a tunnel and provides the information to the tunnel administrative office in order to help safe tunnel operation. The suggested system enhances the processing speed by using simple processing algorithm such as image subtraction, and ensures the accuracy of the system by focused on the incident detection itself rather than its classification. The system is also cost effective because the video data from 4 cameras can be simultaneously analyzed in a single PC-based system. Our system can be easily extended because the PC-based analyzer can be increased according to the number of cameras in a tunnel. Also our web-based structure is useful to connect the other remotely located tunnel incident systems to obtain interoperability between tunnels. Through the experiments the system has successfully detected the incidents in real time including dropped luggage, stoped car, traffic congestion, man walker or bicycle, smoke or fire, reverse driving, etc.

WIVA : WSN Monitoring Framework based on 3D Visualization and Augmented Reality in Mobile Devices (모바일 기기의 3차원 시각화와 증강현실에 기반한 센서네트워크 모니터링 프레임워크)

  • Koo, Bon-Hyun;Choi, Hyo-Hyun;Shon, Tae-Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.2
    • /
    • pp.106-113
    • /
    • 2009
  • Recently, due to many industrial accidents at construction sites, a variety of researches for structural health monitoring (SHM) of buildings are progressing. For real site application of SHM, one of the advanced technologies has blown as wireless sensor networks (WSN). In this paper, we proposed WIVA(WSN Monitoring framework based on 3D Visualization and Augmented Reality in Mobile Devices) system that applies 3D visualization and AR technology to mobile devices with camera based on WSN in order to expand the extent of information can observe. Moreover, we performed experiments to validate effectiveness in 3D and AR mode that utilize WSN data based on IEEE 802.15.4. In real implementation scenario, we demonstrated a fire occurrence test in 3-story building miniature.

A Study on the Integrated Monitoring of a Leakage Current of the Grounding Wire of Neutral Point of the Low Voltage Side of Transformer (변압기 저압측 중성점 접지선의 누설전류 통합 감시에 관한 연구)

  • Hong, Soon-Seuk;Park, Joon-Yeol;Lee, Jung-Eun;Choi, Kyung-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.106-113
    • /
    • 2010
  • If leakage current is neglected, it can become a cause for disasters such as electric shock and fire, therefore a continuous monitoring is necessary. However in most cases, because management of substations is performed by unmanned systems, or walk-around inspections, continuous monitor is difficult. So when an accident occurs and the cause is not immediately resolved causing the emergency generator's OCGR getting activated by the leakage current that in turn cut off the ACB, the emergency generator may stop working. To prevent such a problem, a real-time integrated monitoring system for monitoring the leakage current returning to the grounding wire of neutral point of the low voltage side of transformer is proposed. Therefore in this paper, the effects of flow of leakage current, which is caused by insulation degradation phenomena or insulation destroy phenomena, were identified by simulation. And through cases studies; the excellence of integrated monitoring system was verified.

Validity of solar energy generation at the underused Space of LPG filling station (LPG충전소 유휴공간의 태양광발전설비 설치 유효성)

  • Lee, Minkyung;Kim, Jeonghwan;Lee, Jinhan;Joe, Youngdo;Lee, Yeonjae
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.25-32
    • /
    • 2016
  • The purpose of this study is safety evaluation of solar energy generation which is installed on the canopy at the LPG filling station. in case of a gas station, the solar energy generation was become legalization through a related law reform in 2008. Also, in case of a LPG filling station, the solar energy generation was become legalization through a related law reform in 2015. So, the related law that KGS CODE and Safety control of dangerous substances law and the case of installed solar energy generation in gas, LPG filling station was investigated. two scenarios are supposed for the CFD. Release of safety valve pipeline and ruptured dispenser leakage are the scenarios. The FLACS which developed GexCon in Norway was used for simulation. LPG dispersion to the upper side of canopy was very small with safety distance.

Optimal Route Discovery System for Emergency Escape from Disaster Situations (재난 상황 시 탈출을 위한 최적 경로 탐색 시스템)

  • Kang, Moo-Bin;Joo, Yang-Ick
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.448-449
    • /
    • 2016
  • Enlargement and complexification of current structures increase the expected casualty in case of accident in those e.g., fire. In that case, there only have been basic instructions such as announcement of that situation, alarm bell, exit signs, etc. but any guidance to lead to proper escape route was not been provided so far. To tackle the problem, several schemes have been proposed. However, various risk factors were not considered and route discovery performance must be improved to be applied to structures. Therefore, this paper proposes an optimal route discovery system for emergency escape from disaster situations which takes into account various possible risk factors and enhances the searching efficiency by using the $A^{\ast}$ algorithm. Performance evaluation by computer simulation shows that the proposed scheme effectively leads to safe escape route.

  • PDF

Intelligent evacuation systems considering bottleneck (병목 현상을 고려한 지능형 대피유도 시스템)

  • Kim, Ryul;Joo, Yang-ick
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.69-70
    • /
    • 2017
  • As the industry develops, the size of buildings and ships are getting bigger and more complicated. In such a complex space, emergency evacuation systems are required because of the possibility of casualties when an accident situation occurs. However, because present systems are composed of basic devices, such as alarms, emergency exit signs, and announcement regarding the situation and inform only the least information to evacuees, evacuees are not able to judge objectively. To solve these problems, various evacuation algorithms have been proposed. However, these studies aim to search evacuation routes based on specific risk factors or to model the effects of bottlenecks in evacuation situations. Therefore, there is a limit to apply to real systems. Therefore, we propose algorithms to search the optimal evacuation route considering various risk factors such as fire and bottleneck in evacuation situations and to be applicable in actual situation in this paper. Performance evaluation using computer simulations showed that the proposed scheme is effective.

  • PDF

The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor (16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2016
  • The ELCB(: Earth Leakage Circuit Breaker) is the only way being used to prevent accidents from happening caused by electrical disaster. However, the existing ELCB has a limit to prevent damages to life and property due to a electric fire and a human body electric shock caused by the resistive leakage current, because of detecting the total leakage current in the block range of 15mA~30mA. It also has problems such as reduced productivity and reliability due to malfunctions by capacitive leakage currents. In this study, we have implemented the algorithm for the resistive leakage current detection technique and developed the resistive leakage current detection module based on a MSP430 processor, 16bit signal processor and this module can be operated in a desired block threshold within 0.03 seconds as specified in KS C 4613.

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment I: Transient Thermal (A60급 구획 적용 격벽 관통용 관의 열전달 특성 I: 관의 설계에 따른 과도 열해석)

  • Park, Woo-Chang;Song, Chang Yong;Na, Ok-Gyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.310-323
    • /
    • 2018
  • In order to protect lives and prevent large-scale injuries in the event of a fire on a ship or an offshore plant, most classification societies are strengthening their fire resistance designs of relevant cargo holds and accommodation compartments to keep flames from being transferred from a fire point to other compartments. Particularly in critical compartments, where flames should not propagate for a certain period of time, such as the A60 class division, both the airtightness and fire-resistant design of a piece passing through a bulkhead are subject to the Safety of Life at Sea Convention (SOLAS) issued by the International Maritime Organization (IMO). In order to verify the suitability of a fire-resistant design for such a penetrating piece, the fire test procedure prescribed by the Maritime Safety Committee (MSC) must be carried out. However, a numerical simulation should first be conducted to minimize the time and cost of the fire resistance test. In this study, transient thermal analyses based on the finite element method were applied to investigate the heat transfer characteristics of a bulkhead penetration piece for the A60 class compartment. In order to determine a rational bulkhead penetration piece design, the transient heat transfer characteristics according to the variation of design parameters such as the diameter, length, and material were reviewed. The verification of the design specification based on a numerical analysis of the transient heat transfer performed in this study will be discussed in the following research paper for the actual fire protection test of the A60 class bulkhead penetration piece.