• Title/Summary/Keyword: 화재 감시

Search Result 179, Processing Time 0.042 seconds

An Efficient Image Information Transfer System for Wireless Image Sensor Network Environments (무선 이미지 센서네트워크 환경을 위한 효율적인 영상 정보 전송 시스템)

  • Lee, Sang-Shin;Kim, Jae-Ho;Won, Kwang-Ho;Kim, Joong-Hwan
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.3
    • /
    • pp.207-214
    • /
    • 2008
  • There are lots of studies on application systems using wireless sensor networks. As the application systems are adapted to industrial field, the reliability of these systems becomes new key feature. The lack of reliability is an obstacle to extension of wireless sensor networks. In this paper, we propose the monitoring system framework that can offer the reliability of wireless sensor networks using a micro camera module and wireless sensor network nodes. And also we propose the efficient transfer method for image information over low rate wireless networks. Using these system framework and transfer method, we implement WiSN(Wireless image Sensor Network) based fire monitoring system.

Realization of the Information Visualization of Electric Power Monitoring System for MV/LV Distribution Customers (중소규모 수용가용 전력감시시스템에서의 정보시각화 구현에 관한 연구)

  • 강봉석;김재철;문종필;박기주;권영복
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.157-166
    • /
    • 2004
  • Recently, switchboards for MV/LV distribution customers have been united and digitalized rapidly. This paper suggestes the effective information visualization method for the data mesured from cubicle switchboard for MV/LV distribution customers. We developed the algorithm that analyzes a large number of mesured data and displays them to users overall, such as fire index, power condition index, switchboard safety index, and power diminution index. Using a touch screen made users to operate it easily. User interface was also strengthened by taking graph visualization. We guess the information visualiztion method suggested in this paper shows the new direction that heavy electrical equipments including switchboards are going to develop in the future.

Introduction of Intelligent fire-disaster Surveillance System for Subway Station (도시철도 역사 지능형 화재감시시스템 구축방안 연구)

  • Shin, Jeong-Ryol;An, Tae-Ki;Jeon, Bo-Ik;Kim, Gab-Young;Kim, Hyung-Min;Yun, Byeong-Ju
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.457-465
    • /
    • 2009
  • Subway system including light-rail transit system is the representative public urban transportation. Accordingly, Nothing is more important than the safety operation as well as passengers' convenience. Due to the fire disaster of Daegu subway on 2003, more strict regulations of detecting fire and of conducting on emergency circumstances. However, regardless of this improved management, it was reported that installations of lots of fire-detection facilities may be harm than good to operate subway system due to frequent malfunction of some fire-detection facilities. It may cause mis-alarm for fire and induces abnormal operation of subway due to the strict regulation; the train shall be stopped on emergency circumstances. Therefore, in this paper, new scheme on surveiling breaking-out-of fire in the station is suggested with new IT technologies, Wireless Sensor Network(WSN) and CCTVs. which were integrated with an intelligent software. This intelligent system enables to surveil breaking-out-of fire in real time through sensor network technology and watch the emergency site on CCTV as well. Through this system, subway organizers could cope with the emergency circumstance rapidly as well as judge precisely whether fire breaks out or not.

  • PDF

Performance Improvement of CO Sensor Signal Conditioner for Early Fire Detection System (조기화재 감시시스템을 위한 CO센서의 시그널컨디셔너 성능개선)

  • Park, Jong-Chan;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.2
    • /
    • pp.82-87
    • /
    • 2017
  • This paper presents performance improvement of CO gas sensor signal conditioner for early fire warning system. The warning system is based on the CO sensor and its advanced signal conditioning modules network that employ electochemical gas sensor. The electochemical has advantage of having a linear output and operating with a low consumption and fast response. This electrochemical gas sensor contains a gas membrane and three electrodes(working, counter, reference electrode) in contact with an electrolyte. To use a three-electrode sensor, a voltage has to be applied between the working and the reference electrode according to the specification of the sensor. In this paper, we designed these requirements that should be considered in temperature compensation algorithm and electrode measurement of CO sensor modules by using advanced signal conditioning method included 3-electrode. Simulation and experimental results show that signal conditioner of CO sensor module using 3-electrode have a advantage linearity, sensitivity and stability, fast response etc..

Intelligent CCTV for Port Safety, "Smart Eye" (항만 안전을 위한 지능형 CCTV, "Smart Eye")

  • Baek, Seung-Ho;Ji, Yeong-Il;Choi, Han-Saem
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.1056-1058
    • /
    • 2022
  • 본 연구는 항만에서 안전 수칙을 위반하여 발생하는 사고 및 이상행동을 실시간 탐지를 수행한 후 위험 상황을 관리자가 신속하고 정확하게 대처할 수 있도록 지원하는 지능형 CCTV, Smart Eye를 제안한다. Smart Eye는 컴퓨터 비전(Computer Vision) 기반의 다양한 객체 탐지(Object Detection) 모델과 행동 인식(Action Recognition) 모델을 통해 낙하 및 전도사고, 안전 수칙 미준수 인원, 폭력적인 행동을 보이는 인원을 복합적으로 판단하며, 객체 추적(Object Tracking), 관심 영역(Region of Interest), 객체 간의 거리 측정 알고리즘을 구현하여, 제한구역 접근, 침입, 배회, 안전 보호구 미착용 인원 그리고 화재 및 충돌사고 위험도를 측정한다. 해당 연구를 통한 자동화된 24시간 감시체계는 실시간 영상 데이터 분석 및 판단 처리 과정을 거친 후 각 장소에서 수집된 데이터를 관리자에게 신속히 전달하고 항만 내 통합관제센터에 접목함으로써 효율적인 관리 및 운영할 수 있게 하는 '지능형 인프라'를 구축할 수 있다. 이러한 체계는 곧 스마트 항만 시스템 도입에 이바지할 수 있을 것으로 기대된다.

A Study on the Design and Implementation of Multi-Disaster Drone System Using Deep Learning-Based Object Recognition and Optimal Path Planning (딥러닝 기반 객체 인식과 최적 경로 탐색을 통한 멀티 재난 드론 시스템 설계 및 구현에 대한 연구)

  • Kim, Jin-Hyeok;Lee, Tae-Hui;Han, Yamin;Byun, Heejung
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.4
    • /
    • pp.117-122
    • /
    • 2021
  • In recent years, human damage and loss of money due to various disasters such as typhoons, earthquakes, forest fires, landslides, and wars are steadily occurring, and a lot of manpower and funds are required to prevent and recover them. In this paper, we designed and developed a disaster drone system based on artificial intelligence in order to monitor these various disaster situations in advance and to quickly recognize and respond to disaster occurrence. In this study, multiple disaster drones are used in areas where it is difficult for humans to monitor, and each drone performs an efficient search with an optimal path by applying a deep learning-based optimal path algorithm. In addition, in order to solve the problem of insufficient battery capacity, which is a fundamental problem of drones, the optimal route of each drone is determined using Ant Colony Optimization (ACO) technology. In order to implement the proposed system, it was applied to a forest fire situation among various disaster situations, and a forest fire map was created based on the transmitted data, and a forest fire map was visually shown to the fire fighters dispatched by a drone equipped with a beam projector. In the proposed system, multiple drones can detect a disaster situation in a short time by simultaneously performing optimal path search and object recognition. Based on this research, it can be used to build disaster drone infrastructure, search for victims (sea, mountain, jungle), self-extinguishing fire using drones, and security drones.

A Study on the Comparison between an Optical Fiber and a Thermal Sensor Cable for Temperature Monitoring (온도 모니터링을 위한 광섬유 센서와 온도센서 배열 케이블의 비교 연구)

  • Kim, Jung-Yul;Song, Yoon-Ho;Kim, Yoo-Sung
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • Two kinds of temperature monitoring technology have been introduced in this study, which can measure coincidently temperatures at many points along a single length of cable. One is to use a thermal sensor cable comprizing of addressable thermal sensors. The other is to use an optic fiber sensor with Distributed Temperature Sensing (DTS) system. The differences between two technologies can be summarized as follows: A thermal sensor cable has a concept of "point sensing" that can measure temperature only at a predefined position. The accuracy and resolution of temperature measurement are up to the capability of the individual thermal sensor. On the other hand, an optic fiber sensor has a concept of "distributed sensing" because temperature is measured practically at all points along the fiber optic cable by analysing the intensity of Raman back-scattering when a laser pulse travels along the fiber. Thus, the temperature resolution depends on the measuring distance, measuring time and spatial resolution. The purpose of this study is to investigate the applicability of two different temperature monitoring techniques in technical and economical sense. To this end, diverse experiments with two techniques were performed and two techniques are applied under the same condition. Considering the results, the thermal sensor cable will be well applicable to the assessment of groundwater flow, geothermal distribution and grouting efficiency within about loom distance, and the optic fiber sensor will be suitable for long distance such as pipe line inspection, tunnel fire detection and power line monitoring etc.

Comparison of Surface Fuel and Soil Layer Moisture after Rainfall in Broad-Leaved Forest at Young Dong Region (영동지역 활엽수림에서의 강우 후 지표연료의 습도변화 분석)

  • Kwon, Chun-Geun;Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.49-60
    • /
    • 2012
  • The change in fuel moisture in accordance with the number of days after rainfall is an important factor in predicting forest fire dangers and supporting forest fire rangers. Therefore, in order to clear up these forest fire occurrence conditions, forest fire danger levels for surface fuel 0.6 cm or lower, 0.6~3.0 cm, 3.0~6.0 cm, and 6.0 cm or above by fallen leaves layer, humus layer, soil layer, and diameter after rainfall of 5.0 mm and higher in accordance with tree density in 2008, 2009 Spring/Autumn Young Dong region have been analyzed. Research showed an approximate 17 % fuel moisture which is a dangerous forest fire occurrence level after 5 days from rainfall in medium-density areas and 3 days after rainfall in loose-density areas of Spring time in the fallen leaves layer. On the other hand, the humus layer showed a 40 % or higher fuel humidity even after 6 days from rainfall regardless of the season, while the upper and lower parts of the soil layer had a little change. In loose-density areas with 0.6 cm or less surface fuel per diameter in Spring time, the fuel humidity displayed a dangerous level in fire forest occurrence after 3 days, and 4days in medium-density areas, and for loose-density areas with 0.6~3.0 cm surface fuel per diameter in Autumn time it showed a dangerous level in forest fire occurrence after 3 days, and for medium-density areas, 5 days. In the case of 3.0~6.0 cm of fuel moisture per diameter in both Spring and Autumn times, even after 6 days, low and medium-density areas showed that they maintain fuel moisture and therefore the dangers of forest fires were very low, and in the case of 6.0 cm or higher, it showed 25 % or higher fuel moisture even after 6 days from rainfall regardless of the season.

Development of Prediction Model of Fuel Moisture Changes in the Spring for the Pine Forest Located the Yeongdong Region(Focused on the Fallen Leaves and Soil Moisture Level) (영동지역 봄철 소나무림에서 연료습도변화 예측모델 개발(낙엽 및 토양습도를 중심으로))

  • Lee, Si-Young;Kwon, Chun-Geun;Lee, Myung-Woog;Lee, Hae-Pyeong;Cha, Joo-Young
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.67-75
    • /
    • 2010
  • The fuel moisture changes accompanying with the elapsed days after a rainfall is very important to predict the risk of forest fire and make a good use of forest fire guard. So, to investigate the conditions for the risk of forest fire, it was studied the risk of forest fire for fallen leaves level, rotten level, and soil level after more-than-5 mm-rainfall according to the different forest density of pine forests which were located in Yeong-dong region in the Spring of 2007. The result of the study showed that the around 17% of fuel moisture which was the risky level for forest fire was reached after three days of a rainfall in the coarse dense forest region and after five days in the medium or highly dense forest region. However, for the rotten level represents more than 30% of fuel moisture even after six days after the rainfall, and the lower and upper level of the soil represented a slight or almost no changes. Based on the result, the prediction model ($R^2$=0.56~0.87) for the change of fuel moisture was developed, and it was examined by applying to actual meteorological measurements in the same period of 2008. It showed a meaningful result of 1% level of distinction.

Development of Prediction Model of Fuel Moisture Changes After Precipitation in the Spring for the Pine Forest Located the Yeongdong Region (Focused on the Down Wood Material Diameter) (영동지역 봄철 소나무림에서 강우후 연료습도변화 예측모델 개발 (지표연료 직경두께를 중심으로))

  • Lee, Si-Young;Kwon, Chun-Geun;Lee, Myung-Woog;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.18-26
    • /
    • 2010
  • The change of fuel moisture according to the passed days after a raindrop is very important to forecast risk of forest fire and to make a good use of forest fire watchmen. For that reason, in the Spring of 2007, we researched pine forest that were widespread growing in Yeongdong region to find out the condition of forest fire risk. We developed the forecast model of fuel moisture change on dead tree branches which were dropped on the ground and less than 0.6 cm, 0.6~3.0 cm, 3.0~6.0 cm, and more than 6.0 cm in diameter after more than 5.0 mm in precipitation. The result showed that the less diameter of ground fuel and small stand of pines the faster diminishing of fuel moisture, and the days of reaching to a forest fire danger fuel moisture level were represented by two (2) days for less than 0.6 cm diameter of small stand of pine and three (3) days for 0.6~3.0 cm diameter one, respectively. By those results, we developed the forecast model($R^2=0.76{\sim}0.92$) of fuel moisture change on different diameter of small stand of pine, and found that the model had statistical significant of 1% level after we applied it to the data of 2008 after the same period of raindrop by actual meteorological measurement.