• Title/Summary/Keyword: 화재확산 방지구조

Search Result 32, Processing Time 0.022 seconds

A Study on the Fire Spread Risk of Resident Buildings With Pilotis (필로티 건물 이격거리에 따른 화재확산 위험성 연구)

  • Choi, Seung-Bok;Choi, Doo-Chan;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.103-110
    • /
    • 2017
  • With the common tendency in the accordance with the trend, low-stories built edifices that are Pilotis-oriented structured exponentially and constantly increasing its number of buildings. It inevitably contains its risks of facing conflagrations as most of its part is used as parking lots. In the parking lots, the length of the flame has a heavy-weighted possibility that it would get increased because the heat release rate gets relatively high due to the vehicle insulation. Following on top of that, due to the nature of the Pilotisconsisting of pillars, there is a risk of flame spread to the adjacent building if the same Pilotis-structured buildings are adjacent to each other, if the flame spreads to the surroundings due to the influence of the wind. Because the most of the pilotis-structured-buildings have this entrance that makes the residents be able to enter, if the entrance were plugged the resident get a serious risk of a poisonous gas and a flame. Therefore, if the parking-lots of the pilotis-structured-buildings are adjacent to each other it requires a space to prevent the place from the spread of flame. This research studied how far is appropriate to prevent flame spreading with FDS. As a result, the study found that the distance at least 3.0 m is required.

A Study on the Refractory Performance Verification of the Thermal Insulators for AES Ducts and Piping (AES 계열 덕트·배관 단열재의 내화성능 검증에 관한 연구)

  • Kwang-Ho Ham;Jea-Chun Sa;Joo-Hwan Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.419-429
    • /
    • 2024
  • Purpose: To enhance the non-combustibility of fire protection piping insulation and improve the heat resistance of smoke extraction duct insulation, I plan to verify the suitability of AES insulation materials for these applications through performance testing. Method: The non-combustibility, heat resistance, and thermal insulation performance of AES insulation materials will be verified through various tests. Result: According to the 'Standards for Flame Retardancy and Fire Spread Prevention of Building Finishing Materials,' the results of non-combustibility and gas toxicity tests confirmed the non-combustible properties. The standard fire resistance tests verified the fire resistance performance. Additionally, the thermal insulation performance was confirmed through building insulation tests. Conclusion: As the performance tests on AES inorganic insulation materials have proven their noncombustibility, fire resistance, and thermal insulation performance, these materials are considered a viable alternative for improving fire spread prevention in buildings.

Fire Suppression Test using the Automatic Monitor System for Double-Deck Tunnel (복층터널 자동 모니터 소화설비를 이용한 화재진압 실험)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Kim, Hwi-Seung;Park, Byoung-Jik;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.40-46
    • /
    • 2017
  • As one of the solutions to deal with economic loss caused by traffic congestion in metropolitan area, a deep underground road has been planned and implemented at home and abroad. The part of them has been pushed ahead with a double-deck scheme which has an advantage in constructability and cost efficiency comparing to traditional road tunnel. However, the double-deck tunnel has a lower floor height than the general road tunnel due to the special structure used as the upper and lower lines by installing the middle slab on one excavation section. Therefore, it is relatively weak against fire accidents and ventilation problems occurring in tunnels. Thus study to develop the life safety system optimized to a double-deck tunnel has been systematically carried out in order to overcome their weak point. In this study, automatic monitoring fire extinguisher (AMFE) is developed to suppress a fire and prevent its spread at early stage of tunnel fire, conducting the performance test through vehicle fire tests as verification. The tests were conducted with AMFE being 30 m apart from the vehicle and 10 m apart from engine room. As a results, it was confirmed that AMFE enables to suppress a fire and prevent its spread in both cases.

A Study on Fire Origin Determination Methods by Fire Patterns (화재패턴에 의한 발화부판단 방법에 관한 연구)

  • Kim, Young Chul;Lee, Su Kyung
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.63-63
    • /
    • 2011
  • 화재란 사람의 의도에 반하거나 고의에 의해 발생하는 연소현상으로서 소화시설 등을 사용하여 소화할 필요가 있는 것을 말한다. 사람의 의도에 반한다고 하는 것은 과실에 의한 화재를 의미하며 화기취급 중 발생하는 실화뿐만 아니라 부작위에 의한 자연발화도 포함하며, 고의에 의한다고 하는 것은 일정한 대상에 대하여 피해발생을 목적으로 화재발생을 유도하였거나 직접 방화한 경우를 말한다. 연소현상이라 함은 가연성 물질이 산소와 결합하여 열과 빛을 내며 급속히 산화되어 형질이 변경되는 화학반응을 말한다. 소화시설 등을 사용하여 소화할 필요가 있다는 것은 화재란 연소현상으로서 소화의 필요성이 있어야 하며 소화의 필요성의 정도는 소화시설이나 그와 유사한 정도의 시설을 사용할 수준 이상이어야 한다. 화재원인조사란 발화부를 판단하고 화재에 이르게 된 발화원을 규명하며, 발화부로부터 연소확대된 경과를 조사하는 일련의 행위로서 화재원인조사시 가장 중요한 사항은 발화부 판단인 바, 이는 화재원인이 발화부에만 존재하기 때문이다. 최근에는 다양한 소재의 사용으로 인해 일단 화재로 진행될 경우 인명 및 재산상 피해가 증가하게 되어 있으며, 이로 인해 화재조사시 화학, 물리, 전기, 건축, 기계, 소방 등 다양한 지식과 화재현장에 대한 이해가 요구된다. 화재현장 조사시 발화부 판단의 과학적 접근은 매우 중요한 것으로서, 화재원인의 명쾌한 규명으로 책임한계 구분은 물론, 유사사고의 재발방지를 위한 연구가 필요하다. 본 연구에서는 기 발생한 화재사례에서 얻은 화재패턴을 분석하여 얻은 자료를 통해 발화부를 판단할 수 있는 조사방법을 다음과 같이 제시하였다. 1) 화재시 열전달과 화염확산 과정에서 건축구조물, 내장재, 집적물 및 각종 설치물의 구조, 재질 등에 따라 다양한 화재패턴을 형성하게 됨을 알 수 있다. 2) 화재패턴의 종류로는 화재플럼에 의한 삼각형, 주상, V, U 패턴 등이 있으며, 연소 생성물인 화염, 연기, 열 등에 의해 다양한 형태를 보임을 알 수 있다. 3) 위와 같은 결과를 종합하여 연소의 상승성, 불꽃 및 연기 흔적, 열에 의한 흔적 등에 의해 연소의 방향성을 알 수 있다. 4) 결국 화재현장에서 명확한 화재원인을 규명하기 위해서는 화재패턴에 의해 연소확대과정을 역으로 추적하여 발화부를 결정한 다음, 발화부내에서 화재원인을 찾아내야 할 것이다.

  • PDF

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing (공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.115-123
    • /
    • 2022
  • Statistics on the occurrence of fires in residential facilities over the past 10 years, show that approximately 40% are fires in apartment buildings. To prevent the spread of fire and support evacuation in apartment housing, the fire resistance performance and performance design of fire doors are becoming more important. This study established a database using 395 quality inspection reports from 2016 to 2020, which passed the fire performance test, and derived the fire door performance-influencing factors through an analysis of the structure (12 elements) of the fire door. As a result, the effect of core material, adhesive, hinge type, blowing agent, etc. was confirmed in 287 pass cases. On the other hand, it was confirmed that the occurrence of flames and crevices in the 108 cases of failure were the major failure factors in the fire door fire resistance test. Fire doors are composed of composite materials to prevent failure of fire resistance performance, and efficient design and quality control are required through standardization of components.

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel (대심도 복층터널 화재 시 유입풍속 저감방안 연구)

  • Yang, Yong-Won;Moon, Jung-Joo;Shin, Tae-Gyun
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.81-86
    • /
    • 2016
  • Recently, frequent traffic congestion has occurred in domestic urban roads. As a solution for downtown traffic congestion in domestic urban roads, plans for great depth underground double-deck tunnels have been made. Great depth underground double-deck tunnels that have been planned for passenger cars, has the structure of a network type; the entry of vehicles is carried out in the underground space. In these network great depth underground double-deck tunnels, the cross section and the height of the tunnel are smaller than the general road tunnel, and the smoke of a fire will propagate faster than the evacuation of tunnel passengers by the action of the traffic-ventilation and casualties are expected. Therefore, in the present study, an attempt was made to prevent the delay system for fire smoke diffusion at the time of a fire in a domestic network great depth underground double-deck tunnel according to the area of the tunnel block during the operation of the delay system for fire smoke diffusion to analyze the effects of reducing the inflow velocity. When the area of the tunnel block was not less than 50%, the effect of reducing about 21% of the wind speed acting on the tunnel was significant. If the area is more than 50%, the diffusion rate of fire smoke was reduced by approximately 21%, which will be useful for a safe evacuation.

Statistical Analysis of the Structure and Performance of Fire Doors for Evacuation Space and Common Areas in Apartment Housing (공동주택 대피공간·공용부 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.3
    • /
    • pp.239-249
    • /
    • 2022
  • Fire resistance performance and performance design of fire doors are becoming more important to prevent the spread of fire and support the rapid evacuation of apartment buildings. In this study, a database using 182 evacuation spaces and 308 common areas that passed the fire performance test was established, and fire door performance influencing factors were derived through an analysis of the structure(12 elements) of the fire door. As a result, the effects of fire-resisting filler density, adhesive, and foam gasket were confirmed for evacuation space, and the effects of fire-resisting filler, adhesive, and fire fins were confirmed for common areas. In the fire door fire resistance test, flames and cracks were analyzed as the most frequent failure factors.

Development of 1D River Storage Model for Tracing of Hazardous Chemicals in the Water Environment (수환경 유출 유해화학물질 추적을 위한 1차원 저장대모형 개발)

  • Yun, Se Hun;Seo, Il Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.89-89
    • /
    • 2019
  • 수환경으로 유출되는 유해화학물질은 독성을 가지고 직접 유출되거나 다양한 매체와 반응하여 화재 및 폭발 등의 사고가 발생한다. 실제로 낙동강 유역에서는 1991년 페놀 유출사고를 시작으로 2009년 구미공단 '1,4-다이옥산' 유출사고, 2014년 11월 경북 봉화군의 황산유출사고 등 크고 작은 사고가 빈번히 발생하고 있으며 작년 6월에는 대구와 부산의 수돗물에서 과불화화합물이 검출되기도 하였다. 이러한 대규모 사고를 방지하기 위해 신속한 오염물의 거동 예측이 가능한 추적모델이 필요하며, 본 연구에서는 수환경으로 유출된 유해화학물질의 추적을 위한 1차원 저장대 모형을 개발하였다. 일반적으로 저장대 모형은 복잡한 하천 구조를 하천의 주 흐름이 존재하는 본류대와 하천 흐름이 정체되는 저장대, 그리고 하상구조로 단순화 하여 나타낸다. 본류대에서는 하천흐름에 의한 이송 및 횡방향 유속차로 발생하는 전단류에 의한 확산이 일어나며, 저장대와의 물질교환으로 발생하는 저장효과와, 하상구조와의 흡착 및 탈착, 그리고 생물화학적 반응 및 휘발이 발생한다고 가정한다. 본류대와 저장대간의 질량교환은 난류유속변동과 농도차에 의해서만 발생한다고 가정하고 오염물질의 이송과 분산과정을 해석한다. 저장대에서는 이송 및 전단류에 의한 확산은 일어나지 않으며, 본류대와의 물질교환으로 발생하는 저장효과와 하상구조로의 흡착, 그리고 생물화학적 반응 및 휘발이 발생한다고 가정하며, 하상구조에서는 본류대 및 저장대와의 흡착 및 탈착만 발생한다고 가정한다. 저장대 모형의 해석을 위해서는 리치(Reach) 별로 본류대 분산계수($K_F$), 본류대 면적($A_F$), 저장대 면적($A_S$), 그리고 저장대 교환계수(${\alpha}$)의 네 가지 저장대 매개변수가 필요하며 본 연구에서 개발된 저장대 모형은 흡탈착, 생물화학적 반응 및 휘발 과정을 모두 고려하여 유해화학물질의 확산 거동을 모의한다. 최적의 리치길이, 흡탈착, 반응 및 휘발 계수를 산정하여 모형의 정확도를 향상시켰으며, 신속하고 정확하게 오염물의 거동을 예측할 수 있었다.

  • PDF