• Title/Summary/Keyword: 화재현장

Search Result 610, Processing Time 0.028 seconds

A Theoretical Review on the Planting and Management of Coastal Forests in Korea (우리나라 해안림조성과 관리의 이론적 고찰)

  • Kim, Yong-Shik;Kim, Do-Gyun
    • Korean Journal of Plant Resources
    • /
    • v.30 no.1
    • /
    • pp.110-123
    • /
    • 2017
  • The authors reviewed the history of creation and management, purposes, extents, methods of creation, planting species and mediums, structure of vegetation layers and legal management, etc. of coastal forests of Korea. Since the Goryeo dynasty, the inhabitants in the coastal regions has long been aware the safety from natural disasters and the local governments manages for the defence and natural disasters, and collaboration among GO and NGOs, as well as enterprises are participating to the conservation of coastal forests in Korea. The purposes of creation and management of coastal forests in historical aspects are prevention of disasters, safety by the Fengsui, military uses, and timber productions, but partly as the places for religious beliefs, safety from diseases and fires, increasing of forest products and fishes, as well as tourists, improving of amenity and landscapes and recreation, inherits of traditional culture, habitats for wildlife, and ecological corridors, etc. The inhabitant in the coastal region who experienced frequent natural disasters has strong supports for the conservation of coastal forest and as a natural resources to inherits to the coming generations as the coastal forests has high values of academic researches on human society, culture, ecology and recreational uses, etc. The extensive overall researches on the creation and managements of coastal forests, as well as cultural tradition in the coastal forests of Korean peninsula are critically essential.

A Study on the Durability Performance of a Receptacle for CNG Vehicles (천연가스 차량용 리셉터클의 내구성능에 관한 연구)

  • Choi, Young;Kim, Young-Min;Lee, Yong-Gyu;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.6
    • /
    • pp.15-20
    • /
    • 2010
  • Compressed Natural Gas (CNG) buses have been supplied since the year 2000 in order to resolve severe atmospheric pollution in metropolitan area and contributed on the improvement of urban atmospheric environment. However, it is indispensible to take an adequate measure to guarantee the safety of CNG vehicles because of the possibility of huge fire accident. A receptacle, connecting device between high pressure fuel supply tank and fuel line, plays an important role in CNG supply system. In recent, leakage of CNG from receptacles has been reported. So, the concern about the security and reliability of receptacles has been arisen. Therefore, a lot of efforts to prevent leakage are invested among researchers and the durability of this component should be guaranteed despite repeated operation. This research has performed durability tests of a CNG receptacle regarding the repeated usage, extreme chattering, and continuous full flow test. Although a receptacle used for CNG vehicle satisfies validation requirements in the test results, it has been found that failure in the function of leakage prevention in a receptacle could take place in the case of prolonged exposure to high supply pressure in common quick charging environment on site.

A Study on the Implementation and Modeling of 20kW Scale ESS Load Test Device for Emergency Generator (소방용 비상발전기의 현장부하시험을 위한 20 kW급 ESS 부하시험장치 모델링과 구현에 관한 연구)

  • Choi, Seung-Kyou;Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.541-550
    • /
    • 2019
  • An emergency generator is key equipment for fire-fighting to supply power to fire-fighting facilities, which protect property and people in cases of fire accidents. A rated load test for emergency generators must be carried out by connecting an emergency load to the generator in accordance with related regulations. However, a no-load test has been performed for emergency generators in general since serious problems can occur when the main power is cut off, including the damage of customer devices and shut down of critical loads. Therefore, this paper proposes a load test method for an emergency generator using energy storage system (ESS) without the interruption of main power. The emergency power system was also modeled based on PSCAD/EMTDC software, and a 200-kW scale ESS load test device was implemented. The simulation and test results show that the load test method is useful and practical for an emergency power supply system.

A Study on the Measurement of Explosion Range by CO2 Addition for the Process Safety Operation of Propylene (프로필렌의 공정안전 운전을 위한 CO2 첨가량에 따른 폭발범위 측정에 관한 연구)

  • Choi, Yu-Jung;Heo, Jong-Man;Kim, Jung-Hun;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.599-606
    • /
    • 2019
  • Most facilities that manufacture products made from the hazardous materials operate at high temperatures and pressures. Therefore, there is a risk of fire explosion. In particular, an explosion accident is a major risk factor for facilities with hazardous materials, such as oil, chemical, and gas. Propylene is often used in sites producing basic raw materials and synthetic materials by addition polymerization at petrochemical plants. To prevent an explosion in the business using propylene, the explosion range with the oxygen concentration was calculated according to the changes in temperature and pressure using an inert gas, carbon dioxide. In these measurements, the temperature was $25^{\circ}C$, $100^{\circ}C$, and $200^{\circ}C$ and the amount of carbon dioxide in the container was $1.0kgf/cm^2.G$, $1.5kgf/cm^2.G$, $2.0kgf/cm^2.G$, and $2.5kgf/cm^2.G$. The explosion limit was related to temperature, pressure, and oxygen concentration. The minimum oxygen concentration for an explosion decreased with increasing temperature and pressure. The range of explosion narrowed with decreasing oxygen concentration. In addition, no explosion occurred at concentrations below the minimum oxygen concentration, even with steam and an ignition source of propylene.

A Study on the Crisis Management Standard Manual for Large-scale Human Accident at Workplace for Efficiency of Disaster Response (재난대응 효율화를 위한 사업장 대규모 인적사고 위기관리 표준매뉴얼 개정방안 연구)

  • Woo Sub Shim;Sang Beam Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.656-664
    • /
    • 2023
  • Purpose: The Ministry of Employment and Labor manages disasters based on the standard manual for risk management of large-scale human accidents in workplaces when large-scale disasters such as fires and collapses occur in workplaces. We are going to check the standard manual currently in operation and suggest improvement plans for the insufficient items. Method: Accordingly, the standard manual was checked together with internal and external experts in the disaster management manual and disaster management staff at headquarters and local government offices, and items to be improved were identified with priority. Result: In case of a collapse accident, it is necessary for the Ministry of Public Administration and Security to accurately present the selection criteria in order to eliminate the controversy over the selection of the disaster management department. In addition, it seems necessary to supplement the details of the disaster safety communication network operation and evacuation guidelines. Conclusion: In the future, in order to improve the disaster management system that meets the public's eye level, it is expected to prepare a standard manual for risk management of large-scale human accidents in workplaces that guarantees the lives and safety of workers through the collection of opinions from experts in the relevant field, disaster management personnel, and the general public.

A Survey of Perceptions of Elementary School Teachers on the Small-Scale Chemistry (미량화학(Small-Scale Chemistry)에 대한 초등학교 교사들의 인식)

  • Kim, Sung-Kyu;Kong, Young-Tae
    • Journal of Science Education
    • /
    • v.34 no.2
    • /
    • pp.291-305
    • /
    • 2010
  • The aim of this study was to survey the perceptions of the elementary school teachers on the smallscale chemistry(SSC) following its training session. The teachers participating in the survey were 266 teachers in the Gyeongnam province. They were given a questionnaire that focused on the nine areas of the SSC: Needs for the teacher training and its application, its benefits, issues of safety and danger as well as treatment of environmental pollution, its economic efficiency and the development of investigative skills. The designed questionnaire was checked by an authority, and the responses to each question were tallied and analyzed. The results are as follows. The biggest problems of the traditional experimental methods as rated by the teachers were, in the order of importance, the preparation time, the legal liability of teachers for the safety and accidents, financial issues, disposal of the experimental wastes and the lack of relevant data. Since most of the teachers had not experienced the SSC lab programs in the field, they responded positively to the questions of need for its introduction and training. The implementation of the experimental SSC lab programs should proceed in the following order: introduction into the textbook, teacher training program, after-school education and the invitation of instructors. The most useful materials for the SSC program were CDs, videos, books and various printed materials, in that order. The responses regarding benefits of the SSC program included its simplicity, convenience, time savings, diversity, qualitative and quantitative aspects, integration into the regular class and use of toys. In particular, the teachers mentioned the increased safety due to the small amount of experimental reagents needed and the durability of plastic instruments. The familarity from the use of everyday tools as well as easy access to and the low-cost of the instruments were other important benefits. The teachers in general rated the educational content of the program highly, but many also found it to be average. Some pointed out the lack of sufficient discussion due to the individual or pair groupings as a potential shortcoming. The potential for development of problem solving ability and improvement of skills was rated positively. The number of teacher who rated the development of creativity positively was just over the half. As for the area of improving investigative skills, many found its assessment difficult and confusing because of the lack of its systemic definition and categorization. Based on the findings of this study, I would like to recommend the application and a wider dissemination of the small-scale chemistry lab program into the elementary school science curriculum.

  • PDF

Changes of the Substances during Composting of Seafood Processing Wastewater Sludge (수산가공폐수슬러지의 퇴비화과정중 물질변화)

  • Lee, Hong-Jae;Back, Song-Bum;Kim, Woo-Seong;Park, Hyun-Geoun;Heo, Jong-Soo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.3
    • /
    • pp.55-69
    • /
    • 2001
  • To study the possibility of agricultural utilization of seafood processing wastewater sludges, the changes of temperature and humus, the form of organic matter and nitrogen and the germination ratio of plant during the composting were investigated. The results were summarized as follows. Temperature was rapidly increased at early stage of composting, reached to $67{\sim}76^{\circ}C$ in highest temperature at 3~5 days, and then decreased gradually fallen to $40{\sim}50^{\circ}C$ at 19 days after composting, at the point was upset firstly. The third upset was conducted at 60days after composting, and then the temperature was little changed. The contents of total organic matters in the compost for composting were down 4.5~8.0%. Ether extractable materials, resins and hemicellulose contents of the organic matters for composting were decreased with 35~77%, 32~69% and 19~30%, respectively. And cellulose, lignins and unknown materials contents in the organic matters for composting were increased a little, but water soluble polysaccharides of organic matters were little changed. Total nitrogen, amino sugar and amino acid nitrogen contents in the compost for composting were decreased with 20~42%, 11~49% and 23~65%, respectively. The contents of humic acid in the compost for composting were little changed, but contents of fulvic acid in the compost for composting were decreased gradually. Germination ratio of radish, chinese cabbage and cucumber were over 90%, when the compost produced at 30 days after composting was tested on plant germination.

  • PDF

An Experimental Study on the Pore Structure and Thermal Properties of Lightweight Foamed Concrete by Foaming Agent Type (기포제 종류에 따른 경량기포콘크리트의 기포구조 및 열적특성에 관한 실험적 연구)

  • Kim, Jin-Man;Choi, Hun-Gug;Park, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.63-73
    • /
    • 2009
  • Recently, the use of lightweight panels in building structures has been increasing. Of the various lightweight panel types, styrofoam sandwich panels are inexpensive and are excellent in terms of their insulation capacity and their constructability. However, sandwich panels that include organic material are quite vulnerable to fire, and thus can numerous casualties in the event of a fire due to the lack of time to vacate and their emission of poisonous gas. On the other hand, lightweight foamed concrete is excellent, both in terms of its insulation ability and its fire resistance, due to its Inner pores. The properties of lightweight concrete is influenced by foaming agent type. Accordingly, this study investigates the insulation properties by foaming agent type, to evaluate the possibility of using light-weight foamed concrete instead of styrene foam. Our research found thatnon-heating zone temperature of lightweight foamed concrete using AP (Aluminum Powder) and FP (animal protein foaming agent) are lower than that of light-weight foamed concrete using AES (alkyl ether lactic acid ester). Lightweight foamed concrete using AES and FP satisfied fire performance requirements of two hours at a foam ratio 50, 100. Lightweight foamed concrete using AP satisfied fire performance requirements of two hours at AP ratio 0.1, 0.15. The insulation properties were better in closed pore foamed concrete by made AP, FP than with open pore foamed concrete made using AES.

Impact Assessment of Flame Retardant on Wooden Building with Dancheong (목조문화재 단청에 방염제가 미치는 영향평가)

  • Kim, Hwan-Ju;Lee, Han-Hyoung;Lee, Hwa-Soo;Chung, Yong-Jae;Han, Kyu-Sung
    • Korean Journal of Heritage: History & Science
    • /
    • v.49 no.2
    • /
    • pp.56-69
    • /
    • 2016
  • Flame resistant treatment has been applied since 1973 for fire prevention in historical wooden buildings, but several problems, such as whitening and discoloration are constantly occurring in some Dancheong, in spite of evaluation criteria. It is supposed that these phenomena are caused by the stability issue of flame retardant, Dancheong production methods, the residue of chemicals, which were applied in the past, building location environments, etc., but no evaluation and cause inspection has been performed. Therefore, this study aims to verify the effect of flame retardant on Dancheong by producing Pseudo-samples and setting spatial and temporal environment conditions. Pseudo-samples of Dancheong were produced using three methods; the method specified in the Standard Specification of Properties; the method, which is generally used in the site and the traditional method. For different environment conditions of pseudo-samples, the areas were classified into a coastal area and an inland area and the places were classified into a sunny place and a wetland. After applying a flame retardant, annual variations were inspected for 12 months and change aspects were observed through scan and regular observation. In annual variation inspection, various variations like whitening, decolorization, dissolution and exfoliation were found and especially, whitening was most dominant. When the effect of flame retardant depending on the production methods was analyzed, whitening occurred in all the three production methods. It is supposed that this is because calcium(Ca) was contained in the coloring material of each production method and it reacted with phosphorous(P) of flame retardant. When the effect of flame retardant depending on the environment conditions was analyzed, whitening occurred more in the coastal area than in the inland area and it reduced in the building in a sunny place, which was constructed using the traditional method. It is supposed that this results from the humidity change and the difference of glue used in each production method. In conclusion, for using a flame retardant containing phosphorous(P), there is a need to check if calcium components including Oyster Shell White were used in Dancheong in advance and to conduct various preliminary studies on place conditions and Dancheong construction conditions.

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.