• 제목/요약/키워드: 화재피해 철근콘크리트

검색결과 24건 처리시간 0.033초

화재피해를 입은 철근콘크리트 단주시험체의 보수재료 적용 후 내화성능 평가 (Fire Resistant Performance after Application of Repaired Materials for Fire-Damaged Reinforced Concrete Column)

  • 심상락;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.147-154
    • /
    • 2020
  • Currently, there are no specific repair methods for RC structures damaged by fire, and repair methods are applied when durability deteriorates due to aging. In addition, a number of recent studies have been reported that have conducted fire resistance assessment of the repair materials themselves, assuming exposure to high-temperature environments such as fires. However, researches that evaluate the fire resistance performance of the repair materials by applying existing repair materials to the actual fire damaged reinforced concrete structures are very rare. Therefore, in this study, a number of existing repair materials were applied to fire-damaged concrete column to compare and evaluate the fire resistance performance with the original cover concrete.

다양한 설계변수에 따른 고강도 콘크리트 기둥의 열적 거동 분석을 위한 실험 연구 (Experimental Studies on the Effect of Various Design Parameters on Thermal Behaviors of High Strength Concrete Columns under High Temperatures)

  • 신영수;박지은;문지영;김희선
    • 콘크리트학회논문집
    • /
    • 제23권3호
    • /
    • pp.377-384
    • /
    • 2011
  • 화재에 취약한 고강도 콘크리트 구조물의 화재 피해를 보다 정확하게 예측하기 위해서는 다양한 구조물의 설계 조건과 가열 조건 하에서 열적 특성을 고려하는 연구가 필요하다. 따라서 이 연구에서는 단면 크기, 피복 두께, 철근 배근을 다르게 한 고강도 콘크리트 기둥을 제작하여 다른 가열 조건하에서 가열하였을 때 발생하는 내부 온도 분포와 폭렬을 관찰하였다. 내부 온도 분포는 콘크리트 타설 전 설치한 열전대를 통해서 측정하였으며 가열 전후에 측정한 콘크리트 기둥 실험체의 무게 손실률과 단면 손실률을 통해서 폭렬을 수치화 하였다. 가열 실험은 비재하 상태에서 ISO 834 화재 곡선을 따라 가열하는 실험과 화재 시뮬레이션을 통해 측정한 온도-시간 곡선을 따라 가열하는 실험의 두 가지로 나누어 수행하였다. 고강도 콘크리트 기둥은 일반적으로 고온에서 폭렬이 발생하여 내부 온도의 급격한 증가와 단면 손실을 나타내었으며, 설계 변수에 따라서는 단면이 클수록, 피복 두께가 작을수록 내부 온도 분포와 단면 손실률이 높게 나타났다. 또한 철근비가 동일한 상태에서 철근 배근을 다르게 하였을 때, 단면이 작은 철근을 여러 개 배치하는 것이 단면이 큰 철근을 적게 배치하는 것 보다 높은 온도 분포와 단면 손실을 보였다. 이 연구를 통하여 화재로 인한 고강도 콘크리트 구조물의 열적 변화를 정확하게 파악함으로써, 내화 안전성을 평가하고 현재 적용되고 있는 내화 성능 관리 기준을 보다 효율적이고 안전하게 정립할 수 있도록 하는데 유용하게 활용될 수 있을 것이라고 판단된다.

H형강-국부 콘크리트 합성보지 휨 실험 (Bending Tests of H steel-Partial Concrete Incased Composite Beams)

  • 김성훈;김대곤
    • 한국지진공학회논문집
    • /
    • 제9권3호
    • /
    • pp.77-85
    • /
    • 2005
  • 2001년 9월 11일 세계무역센터 붕괴 후. 그리고 지진발생시 빈번히 발생하는 건물의 화재피해 때문에 구조부재의 내화에 대한 사회적 관심이 증대되었다. 최근에는 전통적인 방법이 아니라 콘크리트의 내화성능과 철골의 구조적 특성을 복합한 내화성능이 향상된 합성구조에 대한 연구가 진행 중이다. 본 논문에서는 내화성능향상을 목적으로 개발된 부분적으로 철근콘크리트로 채워진 H형강-국부 콘크리트 합성 보의 상온에서의 휨 거동을 조사하기 위하여 몇 가지 합성상세를 갖는 실험체들의 휨실험을 실시하였다. 실험결과 $6\~8$의 변위 연성계수를 얻었다. 콘크리트와 철골의 일체화를 위한 합성상세간의 횡 거동 차이는 미미하였고, 극한 휨 강도에 가장 영향을 주는 것은 배근된 주철근 양임을 알 수 있었다. 따라서 중진 지역의 내진설계시 이 타입의 합성보를 사용하면 단일 H형강에 철근배근만 달리하여 상당부분의 층에서의 보의 춤을 동일하게 유지할 수 있다.

고온에 일면 노출된 콘크리트부재의 손상깊이 평가를 위한 실험적 연구 (A Experimental Study on the Evaluation of Deteriorated Concrete Member Exposed One Side at High Temperature)

  • 이중원;최광호;홍갑표
    • 콘크리트학회논문집
    • /
    • 제18권3호
    • /
    • pp.431-438
    • /
    • 2006
  • 화재 피해 콘크리트 건축물의 기존 손상도 평가 방법은 명확한 손상 깊이를 정량적으로 추정하기가 어렵고, 특히 코아 압축강도 테스트는 콘크리트 깊이별로 수열온도 따라 손상도의 변화를 반영하지 못하고 손상 공시체의 압축강도를 구조체 압축강도 저하의 대표 값으로 사용하게 되어 손상 깊이의 판단이 어려운 불합리한 점이 있다. 따라서 본 연구에서는 화재 피해를 입은 철근콘크리트 슬래브나 벽체 부재의 손상 깊이를 정량적으로 평가하기 위해서, 공시체를 대상으로 전기로에서 일면 가열한 후, 2cm 두께로 절편화시켜 색조분석, 흡수율 및 할렬인장강도실험에 의한 압축강도를 분석함으로써 공시체 깊이별 손상 깊이를 정량적으로 평가하는 실험기법을 제안하고 고온에 노출된 콘크리트의 특성변화를 고찰함으로써 그 적용성을 검증하였다. 실험결과, 본 연구에서 제안한 손상도 평가기법은 가열조건 및 강도별로 공시체 깊이에 따른 잔존강도의 정량적 평가가 가능하였으며, 이 결과를 이용하여 화재를 경험한 슬래브나 벽체의 보수보강 범위를 선정하는 판단 기준으로 활용할 수 있는 것으로 나타났다.

화재 피해를 입은 일반 강도 철근콘크리트 휨부재의 구조 거동 (Structural Behavior of Fire-Damaged Reinforced Concrete Beam with Normal Strength Concrete)

  • 이소진;신영수;이차돈;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.307-312
    • /
    • 2002
  • This paper deals with structural behavior of reinforced concrete beams under fire and fire damaged condition. The main purpose of this study is to investigate the structural behavior of the beams under high temperature condition and to evaluate the remaining strength of flexural members by exposure time to fire. For this purpose, twelve beam specimens are fabricated and experimented. Ten specimens are exposed to the fire for 1 and 2 hours and to the failure. After being cooled in room temperature, the specimens are loaded to the failure. The research result shows that the main variables of the test, concrete cover and exposure time to fire are much influenced on the structural behavior and the remaining strength.

  • PDF

화재 피해를 입은 고 강도 철근콘크리트 휨 부재의 구조 거동 (Structural Behavior of Fire-Damaged Reinforced Concrete Beam with High Strength Concrete)

  • 신미경;신영수;이차돈;홍성걸;이은주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.635-638
    • /
    • 2003
  • This paper deals with structural behavior of reinforced concrete beams with high strength under fire and fire damaged condition. The main purpose of this study is to evaluate the residual strength of flexural members by exposure time to fire. For this purpose, six beam specimens are fabricated and experimented. Among the specimens, four specimens are exposed to the fire for 60 and 90 minutes and two specimens are control beam that is not exposed to fire. After being cooled in room temperature, the specimens are loaded to the failure. The research result shows that the main variables of the test, concrete cover and exposure time to fire are much influenced on the structural behavior and the residual strength.

  • PDF

화재 피해를 입은 철근콘크리트 슬래브의 잔존 구조성능 평가기법 (Evaluation Techniques for Residual Structural Performance of a Reinforced Concrete slab under Fire Damage)

  • 최광호
    • 한국산학기술학회논문지
    • /
    • 제21권2호
    • /
    • pp.588-594
    • /
    • 2020
  • 이 연구에서는 철근콘크리트 건축물의 슬래브에 대해 화재 후 잔존 구조성능을 상온 시 내구성 진단과는 다르게, 고온특성을 보다 정확히 평가하기 위하여 전기로를 이용 800 ℃까지의 가열실험을 수행하였고 가열 전 후의 잔존 구조성능을 반발경도법과 초음파속도법 등의 비파괴 검사와 아울러 진동실험으로 구한 고유진동수로 처짐계산에 사용되는 강성을 평가하는 기법을 제안하였다. 반발경도를 이용한 압축강도 평가에서는 두꺼운 두께와 물/시멘트비(W/C)가 큰 실험체의 잔존 압축강도가 크게 나타났다. 콘크리트를 투과하는 초음파속도로 상온 대비 고온수열 콘크리트의 균질도를 평가하였으며 W/C와 부재 두께의 차이는 초음파 속도법의 결과에 큰 차이가 없는 것으로 판단되었다. 화재 피해 슬래브의 처짐 증가에 영향을 미치는 강성을 평가하기 위한 기법으로, 진동실험에 의해 고유진동수를 측정하고 이를 강성과의 관계식에 대입하였으며, 이를 슬래브 실험체에 적용해 본 결과 매우 합리적인 평가기법이 될 수 있음을 보여주었다. 또한, 고온 수열 후 부재의 잔존강도를 평가하기 위해 가열중과 가열 후 가력실험을 수행한 결과 800 ℃ 내력은 상온의 부재 내력에 비해 22%의 감소를 나타내었다.

화재 피해를 입은 고강도 철근 콘크리트 압축부재의 비파괴 검사 (Non destructive test of Fire-damaged reinforced concrete columns with high strength concrete)

  • 서지민;이수진;최은규;신영수;이차돈;권영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.13-16
    • /
    • 2005
  • This study is aimed to investigate the strength variation of fire-damaged reinforced concrete column by non-destructive test. It is studied to infer the recovery degree of residual strength of fire-damaged concrete. For measuring the surface hardness of RC columns. Schmidt hammer test is used. Testing is performed three-times: before fire test, directly after fire test and after 20 days.

  • PDF

신개발 내화재료에 피복된 철근콘크리트 터널라이닝의 내화성능평가 (Evaluation of fire-proofing performance of reinforced concrete tunnel lining coated by newly developed material)

  • 박해균;김장호
    • 한국터널지하공간학회 논문집
    • /
    • 제10권4호
    • /
    • pp.329-336
    • /
    • 2008
  • 도심지 생활 편의를 위한 효율적인 교통 네트워크가 요구되고 있다. 그러나 과밀한 교통 네트워크는 교통체증은 물론 지반환경에 좋지 않은 영향을 주고 있어 터널 및 지하공간에 대한 효율적인 사용과 개발이 요구된다. 지난 20년간 전세계에서 많은 터널 화재사고가 발생하였으며, 그 결과 인명 및 구조물 피해는 물론 경제적으로 큰 손실을 초래하였다. 산악터널의 경우에는 화재 발생에 따른 터널 라이닝의 손상이 터널 안전성에 큰 영향을 주지는 않을 것이다. 그러나, 쉴드터널, 침매터널, 개착터널의 콘크리트 라이닝은 구조부재로 사용되는 관계로 화재 발생이 터널 붕괴로 이어지는 위험성을 안고 있다. 본 연구의 목적은 새롭게 개발된 시멘트계 내화재료로 피복된 터널 철근 콘크리트 라이닝의 내화성능을 평가하기 위함이다. 콘크리트 라이닝 시편을 대상으로 독일의 RABT 내화곡선(최고온도 $1,200^{\circ}C$), 네델란드의 RWS 내화곡선(최고온도 $1,350^{\circ}C$)을 이용하여 실험을 실시하였으며, 그 결과 RABT 내화곡선 하에서는 30mm의 내화피복만으로도 우수한 내화성능을 확인할 수 있었다.

  • PDF

화재피해를 받은 철근콘크리트 건축물의 기둥의 영향인자를 고려한 해석적 연구 (Numerical Study on the Fire Damaged Reinforced Concrete Building Structures Considering Influencing Fire Case and Parameters of Columns)

  • 서연우;손희주
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.101-112
    • /
    • 2022
  • Expanding urbanization practices result in high numbers of buildings being developed in city centers. This high building concentration leads to an increased fire risk, resulting in higher casualty rates and increased economic damages compared to fires in the past. The purpose of this study was to analyze the structural behavior of fire-damaged reinforced concrete buildings using analytical methods and to suggest methods of improving fire resistance in the event of a fire. Damage levels were measured using commercial software to apply the finite element method, ABAQUS, and MIDAS GEN to the dataset. Load-deflection curves were calculated using the effective area and moment of inertia of the fire-damaged columns provided by ABAQUS. The results of this analysis indicate that fire-damaged beams with experience greater deflection from indoor fires than they will from outdoor fires. Fires that occurred on the middle floors were more dangerous than those occurring on higher floors, and eccentrically loaded columns experienced more damage than axially loaded columns. The results indicate that these methods accurately predict structural behaviors of fire damaged concrete columns by considering fire exposure area and eccentric loading.