• Title/Summary/Keyword: 화재위험성 평가

Search Result 438, Processing Time 0.026 seconds

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

An Experimental Study on the Fire Risk at Welding·Cutting Process (용접·절단 작업시 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.60-66
    • /
    • 2012
  • In this study, it was evaluated the fire risk during welding cutting tasks. Welding-cutting machines are representatively used at construction sites. Inverter AC/DC TIG welding macnine and inverter air plasma cutting machine were used in experiments. Temperature of spreaded cinders was measured using a thermal camera. Cinder sizes and spread range were measured according to the height and input current. It was also evaluated the fire risk during welding-cutting process, when flammable materials were located around the working area. There were used hay, dust fence, urethane foam, vinyl, paper and oil as flammable materials. Temperature of spreaded cinders was reached at about $450^{\circ}C$. Cinders were spread approximately 4.7 m, when a worker carried out cutting process at 2.5 m height. The possibility of a fire is very high, when flammable materials were located around the working area.

A Study on the Fire Risk Assesment of Solvent-based Paints (유성페인트의 화재 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Kwon, Seong-Pil
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • Currently, flammable liquids account for more than 87 wt% of the hazardous materials in circulation in Korea, and paint products are the most commonly used mixed hazardous materials. Therefore, one of the most urgent and important issues is that we have to secure the safety for manufacturing, storage and transport of paint products. In this study we investigated and analyzed the domestic hazardous materials safety management method, the international GHS test method and so forth. We tested risks for a variety of oil paints and found a relation between the results. Furthermore, the risk test method and criteria adapted for domestic situation was presented. Paints were classified as hazardous or non-hazardous according to the results of the flash point test, the amount of flammable liquid or the UN-combustion persistence test. It was revealed from the test results of 6 kind of oil-based paints using different resins that they were hazardous materials with very high risks and belonged to the Category 1 or the Category 2.

A Study on the Life Risk Assessment of Ship's Engine Room Fire (기관실화재 인명위험성평가에 관한 연구)

  • Han, Sang-Kook;Cho, Dae-Hwan;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.283-289
    • /
    • 2006
  • This study is a preparation for the application of FSA (Formal Safety Assessment) to the fire safety of ships. FSA is the new-fashioned methodology proposed to prevent ships from the accidents. To make a base of the fire safety assessment about ship's fire protection design and Classification Society rule, statistical informations for the fire safety engineering are investigated. From results, the necessity of new criterion for ship's fire safety design, the need to study the human behavior in the evacuation from fire, and the development of new fire progress model considering special situations in ships are acknowledged.

  • PDF

A Study on the Evaluation Model of Disaster Risks for Earthquake : Centering on the Cases of Cheongju City (지진에 대한 재해위험도 평가 모형에 관한 연구 - 청주시 사례 중심으로 -)

  • Jeong, Eui-Dam;Shin, Chang-Ho;Hwang, Hee-Yun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.67-73
    • /
    • 2010
  • Relatively high density of population and buildings exists in urban area mainly because of broad job opportunities and conveniences available. In other words, if happened, there might be high possibility of disaster which can not be easily recovered. The purpose of this study is to show evaluation approach of the risk degree resulted from the disaster, which considers the attributes of urban area. Cheongju-city in Chungcheongbuk-do is selected as sample district to be estimated. The degree of overall risk including fire risk, building collapse risk, evacuation risk and gas explosion risk etc. is analyzed in the designated area. The analysis suggests the highest risk degree in Bukmun-ro district which also shows CBD decline phenomenon. Therefore, it can be not only predicted that this area as old downtown has not been provided with disaster prevention operation and urban renewal project, but also judged that administrative assistances for the disaster are required possibly soon.

Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions (지하철 승강장 급배기 조건에 따른 화재 위험성 평가)

  • Kim, Ha-Young;Rie, Dong-Ho;Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.29-34
    • /
    • 2008
  • In this research, to establish the emission for the people who are clearing out, through the numerical analysis using the CFD model, the dangerousness has been investigated in the various emission conditions in a station platform. As a result of research, it is found out that the temperature variation falls between 65.37% and 74.97% to compare without installation of platform screen doors. In the addition, with the supply mode or push-pull mode, the warm current is generated in the platform so the temperature and the layer of smoke are stirred up and felled off. It will make the dangerousness when the people escape. Therefore, when the capacity of emission and the space of platform is set up, the design regards the properties of the fire emission.

Derivation of Building Fire Safety Assessment Factors for Generating 3D Safety Status Map (3D 안전상태지도 제작을 위한 건물 화재안전 평가항목 도출)

  • Youn, Junhee;Kim, Taehoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.40-47
    • /
    • 2020
  • Various technologies, systems, and legal systems are applied to prevent and quickly respond to fire disaster; nevertheless, the damages to life and property caused by fires are not reduced every year. For managing fire disaster, generating spatial information-based safety status map and procuring suitability of attribute information for each position information are essential. The safety status map is generated by deriving the fire safety status assessment factors, indexing, and locating the surveying results through various methods. In this paper, we deal with derivation of building fire safety assessment factors for 3D safety status map. At first, we survey the foreign and domestic fire assessment model cases and its factors, and analyze the applicability of Korean 3D fire safety status map. Next, assessment factors for fire safety assessment model are derived. Assessment factors are derived and categorized by their information collecting activity; factors that can be accessed through basic building information and factors that can be accessed through field survey. As a derivation result, 14 assessment factors were derived over five categories(Industry Risk, Structural Risk, Fire Fighting Facility, Fire Dangerousness, Fire Response Status).

Risk Assessment and Hazard Information Map Generation of Urban Areas (도시지역 위험도 평가 및 재해정보지도 제작)

  • Park, Ki-Youn;Choi, Woo-Suk;Kim, Weon-Seok;Yoo, Hwan-Hee
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.363-368
    • /
    • 2005
  • 도시지역의 토지이용의 고도화로 도시재해가 증가하고 있으며 향후에도 증가될 가능성이 매우 높은 실정이다 따라서 본 연구에서는 건물들의 재해특성을 분석하고 위험도를 평가하여 재해가 일어나기 전에 발생 위험성을 사전에 분석하여 위험도를 평가하고 평가 결과를 이용해 재해정보지도를 제작하는 것을 목표로 하여 연구를 수행하였다. 그 결과 위험도항목을 자연조건, 토지이용 및 건축물, 인구, 교통, 위험물취급시설로 구분하여 자료를 구축하고, 항목별 위험도를 설정하여 등급화 하였으며, 침수위험도, 화재위험도, 대피위험도, 건물붕괴 위험도로 구분하여 재해지도를 제작함으로서 해당지역의 지구단위계획을 수립 시 재해요소를 적용할 수 있고, 재해발생시 사전대응 및 대피를 위한 정보를 효과적으로 제공할 수 있었다.

  • PDF

Hazard Evaluation on Fire and Explosion Characteristics of Resorcinol (레조르시놀의 화재·폭발 위험성 평가)

  • Lee, Keun Won;Choi, Yi Rac;Song, Se Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.45-50
    • /
    • 2013
  • Resorcinol is widely used as a wood, tire adhesives, and a raw material of synthetic dye. This material with white crystals at room temperature, the particulates in the air can form explosive mixtures. It is known to be an explosion hazard when exposed to heat in a confined space. The study was evaluated fire and explosion characteristics of the resorcinol through thermal analysis, thermal stability, dust explosion characteristics, and the minimum ignition energy. From this study, it can be used to provide a safety information in the using and handling process of the resorcinol.