• Title/Summary/Keyword: 화염전파

Search Result 312, Processing Time 0.02 seconds

A Study on the Fire Reconstruction of Exterior on High-rise Building (Focus on Fire Case Including the Woosin Golden Suite in Haeundae) (고층 건축물 외장재의 화재 재현에 관한 연구 (해운대 우신골든스위트의 화재사례를 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • 'Heaundae Woosin Building' fire was the case that a fire breaking out on the $4^{th}$ floor spread out the $38^{th}$ floor which is a top story and the penthouse was destroyed by fire. After this fire, the fire safety for high rise buildings has been on the rise and several new laws and regulations related in the buildings were created. The study is to analyze Heaundae officetel building case using FDS which is one of the CFD programs for fire. The methodology of this study is to analyze the case comparing with fire spread and route from a virtual fire simulation and related articles and a video clip of actual scene fire. This study shows that a fire spreading on top of levels spent approximately 30 minutes and, which is similar to the actual fire case. Also the pattern of spread has similarity with the case. However, even if the actual fire case shows the fire pattern was "V shape", the smoke-view presents the fire dose not spread horizontally as much as the real fire case. The result shows uncertainty of the modeling based on many grids and a limitation of putting interior finish input sources and the direction of the wind might cause the difference. Also, to analyze factors influencing on a vertical fire, another fire modeling is performed by in condition of modeling environment considering concrete interior finish between buildings and no wind. The result presents the fire spread in smoke-view does not spread vertically as much as the actual case.

Mg-Al합금의 조성비율에 따른 발화온도특성

  • Han, U-Seop;Lee, Geun-Won
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.77-77
    • /
    • 2013
  • 최근의 산업활동에서는 신규 원료 개발과 생산 효율성을 높이기 위하여 분체 공정이 증가하고 있는데, 미세 분진의 취급으로 분진운의 형성과 착화가 용이해지므로 분진폭발이나 화재 위험성이 증가하고 있다. 분진을 안전하게 사용하고 저장, 취급하기 위해서는 착화 전의 위험성 지표로서 최저발화온도(MIT ; Minimum Ignition Temperature)를 사전에 파악해 두는 것이 중요하다. 분진농도의 발화온도는 장치 내의 발화위험성이나 분진 취급 공정의 사고예방대책 관리를 위한 실용적 관점에서 중요하게 활용되는 폭발특성값이다. 또한 분진의 발화온도는 분진농도에 의존하며 농도변화에 따른 가장 낮은 온도를 MIT라고 한다. 본 연구에서는 화재폭발사고 빈도가 줄지 않고 있는 Mg 및 Mg-Al합금(60:40 wt%, 50:50 wt%, 40:60 wt%)을 대상으로 조성비율에 따른 최저발화온도를 실험적으로 조사하였다. Mg 및 Mg-Al(60:40 wt%), Mg-Al(50:50 wt%), Mg-Al(40:60 wt%) 시료의 평균입경은 142, 160, 151, $152{\mu}m$이다. MIT실험장치는 IEC 61241-2-1(Methods for Determining the Minimum Ignition Temperatures of Dust, 1994)에 준거하여 제작하여 사용하였다. 실험장치는 가열로, 분진운 시료홀더, 온도조절장치, 압축공기 제어장치 등으로 구성되어 있다. 구체적인 실험방법은 시험분진를 분진홀더에 장착하고 0.5 bar의 압축공기를 0.3 sec 동안 사용하여 일정 온도로 가열된 로의 내부로 분진운을 부유시킬 때에 분진운이 발화하여 가열로 하단부의 개방구에까지 화염이 전파하는지를 디지털비데오카메라로 기록, 평가하여 발화 유무를 판정하였다. Mg합금에 대한 MIT를 측정한 결과 $740^{\circ}C$가 얻어졌으며, Mg-Al(60:40 wt%)의 MIT는 $820^{\circ}C$로 조사되었다. 그러나 Mg-Al(50:50 wt%) 및 Mg-Al(40:60 wt%)에 대해서는 최대 가열로의 설정온도를 $890^{\circ}C$까지로 하여 농도를 변화시키면서 조사하였으나 발화가 일어나지 않았다. 문헌에 따르면 Mg입자 표면의 산화피막은 다공성으로 일정 온도에서 산화반응이 시간에 따라 직선적으로 증가하는데 반하여, Al의 산화피막은 보호 작용을 하여 일정 온도에서 산화반응속도가 표면과 내부의 농도 기울기에 의한 확산속도에 의존한다고 보고하고 있다. 본 연구결과를 토대로 Mg-Al합금의 발화특성을 고찰해 보면, Mg-Al합금에서 자기 전파성이 작은 Al성분의 증가는 착화지연이 증가하여 연소성이 감소하여 최저발화온도의 증가로 이어지는 것으로 추정되었다. 또한 발화온도는 주어진 조건의 온도장에서 분진이 존재하는 시간 길이에 따라 변화하므로, 발화온도를 실험적으로 측정하는 경우에는 측정장치나 방법에 따라 달라지므로 사업장의 현장에 발화온도를 적용하는 경우에는 장치 내의 분진의 존재시간을 고려할 필요가 있다.

  • PDF

Analysis on the Heat-resisting Coating of High Heat-resisting/Smoke Retardancy Fireproof Fabrics and Products (고내열/차연성 방화제품의 내열 코팅에 관한 연구)

  • Kim, Sang-Ryong;Kim, Sang-Wook;Lee, Do-Hyun;Min, Moon-Hong;Son, Hyun-Sik;Ahn, Seung-Guk;Bae, Jin-Hwa
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.97-97
    • /
    • 2011
  • 현대사회에서 화재에 의한 물적 피해는 물론 인적피해가 현저하게 증가하고 있으며 희생자의 사망원인이 종래에는 화재시 발생한 열에 의한 화상을 중심으로 하는 소사였지만, 최근에는 화염보다 독성가스로 인하여 사망하는 경우가 많아졌고, 희생자는 거의 화상을 확인할 수 없거나 화상자이더라도 혈액 중에서 일산화탄소를 중심으로 한 유독가스가 확인되기 때문에 이들 유독가스의 흡입으로 인하여 행동불능상태 이후 열의 영향으로 사망한 것으로 추정되는 사례가 증가하는 추세이다. 따라서 대규모 건축물에 있어서는 화재발생시 유독가스가 건물 전체로 연소 확대되는 것을 방지하기 위하여 넓은 면적을 일정한 면적으로 구획하거나 계단실 등과 다른 부분 또는 층별 등으로 구획하고 있으며, 국내의 방화구획은 크게 다른 층으로 화재전파를 막기 위한 층간 방화구획, 연소면적을 제한하기 위한 면적별 방화구획, 다른 용도로 인한 화재 위험성 감소를 위해 용도별 방화구획으로 3가지를 법에서 채택하고 있다. 방화구획은 방화문 또는 자동방화셔터를 이용하거나, 내부구조의 바닥, 벽, 각종 방화문으로 구획할 것을 정하고 있다.(피난방화규칙 제14조) 본 연구에서는 철제방화셔터 대체용으로 직물방화셔터용의 실리카 소재를 이용하여 제직한 직물에 내열/차연 기능성 코팅의 공정 조건을 변화하여 최종 방화시험을 거치기 전 내열성 테스트중 하나인 불꽃열 통과량 실험을 실행하여 방화 직물의 내열성을 비교 분석하였다. 이러한 결과를 토대로 본 연구는 고내열/차연성 방화 제품 기술을 개발하는데 필요한 연구를 수행하는데 목적이 있다.

  • PDF

Electrochemical characteristics of WC-27NiCr and WC-10Co4Cr coated Al bronze (WC-27NiCr과 WC-10Co4Cr로 코팅된 동합금의 전기화학적 특성)

  • Kim, Min-Seong;Park, Jae-Cheol;Jang, Seok-Gi;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.80-80
    • /
    • 2011
  • 세계 기후 변화와 불안정한 유가 변화에 대응하고 국내산업의 저탄소 녹색성장을 위해 신재생에너지 개발이 활발하게 이루어지고 있다. 해양에너지 중에서 조류발전은 대규모 댐을 건설할 필요가 없어 비용이 적게 소요되고 특히 날씨 변화나 계절에 관계가 없고, 발전량이 예측 가능하므로 신뢰성 있는 에너지원으로 적용이 가능하다. 조류발전기 블레이드에 폴리머계 복합재료와 스테인리스강이 대부분인데, 이 재료는 특정 회사에서만 제작 가능하며, 충격에 약하고, 균열전파 속도가 빠르며, 대단히 고가이며, 수입에 의존하고 있는 실정이다. 이러한 조류발전에 사용되는 블레이드는 가혹한 부식, 캐비테이션 그리고 침식환경에 노출되어 있어 내구성이 우수한 제품개발이 대단히 중요하며, 조류발전 블레이드를 동합금으로 제작시, 내식성이 뛰어나며 구리의 특성상 해양생물 서식을 방지할 수 있고, 내캐비테이션 특성, 내구성, 가공성 및 유지보수가 용이한 장점이 있다. 이러한 동합금에 WC-27NiCr와 WC-10Co4Cr를 초고속 화염용사(HVOF)를 이용하여 코팅층의 캐비테이션 특성 및 전기화학적 거동을 연구하였다. 본 연구에서는 조류발전용 블레이드의 재료로 사용하려는 동합금에 WC-27NiCr와 WC-10Co4Cr이 용사코팅된 시험편을 사용하였다. 다채널 부식시험기인 WonA-tech WMPG-1000을 이용하여, 자연전위를 측정하였으며, 분극실험은 자체 제작한 홀더를 사용하여 $0.3318cm^2$를 노출 시켜 실험하였다. 기준전극은 은/염화은 전극을, 대극은 백금 전극을 사용하였다. 양분극과 음분극 실험을 통해 개로전위에서의 부식거동을 확인하였고, 정전위 실험도 실시하였다. 실험 종료 후 3D현미경 및 전자주사현미경(SEM)을 사용하여 코팅층 표면의 손상거동을 관찰하였다. 캐비테이션 실험은 ASTM-G32 규정에 의거하여 압전효과를 용한 진동발생 장치(RB 111-CE)를 사용하였다. 수조는 전기화학적 부식의 영향을 고려하여 아크릴로 제작하였고, 시험편은 실험장비에 맞게 파인커팅머신을 이용하여 $20mm{\times}20mm$로 절단하여 사용하였으며 혼과 대향하도록 하여 1mm 간격을 두어 실험하였다. 실험 실시 전, 미소전자저울을 사용하여 무게감소량을 측정하였으며 표면관찰을 통하여 캐비테이션 거동을 관찰하였다.

  • PDF

The Effects of Nozzle Shapes and Pressures on Boundary Layer Flashback of Hydrogen-Air Combustor (수소 전소용 연소 노즐 형상과 연소실 압력이 경계층 역화에 미치는 영향)

  • WON JUNE LEE;JEONGJAE HWANG;HAN SEOK KIM;KYUNGWOOK MIN;MIN KUK KIM
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.776-785
    • /
    • 2022
  • Hydrogen combustion in modern gas-turbine engine is the cutting edge technology as carbon-free energy conversion system. Flashback of hydrogen flame, however, is inevitable and critical specially for premixed hydrogen combustion. Therefore, this experimental investigation is conducted to understand flashback phenomenon in premixed hydrogen combustion. In order to investigate flashback characteristics in premixed hydrogen (H2)/air flame, we focus on pressure conditions and nozzle shapes. In general, quenching distance reduces as pressure of combustion chamber increases, causing flashback from boundary layer near wall. The flashback regime for reference and modified candidate configurations can broadly appear with increasing combustion chamber pressure. The later one can improve flashback-resist by compensating flow velocity at wall. Also, improved wall flow velocity profile of suggested contraction nozzle prevents entire flashback but causes local flashback at nozzle exit.

Study on the Deep Stead Fire Spread Temperature by the Change of the Wood Flour Density (목분의 밀도변화에 따른 온도전이에 관한 실험적 연구)

  • Kim, Jin Su;Rie, Dong Ho
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.1-5
    • /
    • 2015
  • The productivity and demand of porous material has been increasing by development of industry and increasing income. In particular, the fire caused by using wood flour risks wood processing industry and stock farm. The heat transfer of wood flour is carried into the depth direction by effect of oxidizer around flame, flame sometimes is progressed as smoldering. In the case of progressing as combustion fire, identifying the location of fire is difficult, and it leads to failing fire aid fire fighting. Therefore potential cause is acted as raising additional damage. This paper conducts experiments of downward deep seated fire of natural convection conditions. The samples is New Zealand wood flour that is demanded much in the domestic and oversea market. In this experiment, temperature of deep seated side is measure by changing wood flour density in holder The densities used in experiment are 3%, 5%, 10%, 15%. As a result, the tendency of temperature inside decreases as wood flour density increases. But, in the case of density which is above $0.2140g/cm^3$, the phenomenon, decreasing temperature, is not shown. The result of measurement show that average flame spread speed of wood flour is 0.249 mm/min.

A Study on the Fire Characterization of Foam block using Cone-calorimeter and FTIR (콘칼로리미터와 적외선분광계(FTIR)를 이용한 폼블럭의 연소특성에 대한 실험적 연구)

  • Han, Bong-Hoon;Seo, Dong-Ho;Kwon, Young-Hee;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.23-32
    • /
    • 2017
  • Foam block, popularized as the self-interior goods, is susceptible to fire since the main material is the polyethylene flammable synthetic resin. However, it is widely used in homes, offices, and multi-use facilities. In order to understand the fire characteristics of the foam block, two kinds of foam blocks sold in the market (non-fire retardant and fire retardant) were evaluated according to standard of KS F 5660-1 (Reaction to fire test). In addition, the hazard analysis of the gas generated by the combustion of the specimen was performed using the FTIR gas analyzer. The cone calorimeter test showed that the ignition and flame combustion of both two specimens were burned as soon as the radiant heat blocking device was removed, and it was confirmed that the flame could become a rapid propagation factor during the fire. The analysis of the combustion gas through the FTIR gas analyzer showed that both the carbon dioxide and carbon monoxide classified as the common combustion gases and the acrolein, ammonia, and hydrogen cyanide causing serious damage to the human body were detected substantially. This study showed that a foam block product has high ignitionability and generates toxic gases. Hence, it is urgently required to establish the standards used for properly classifying the combustion characteristics of the material on the basis of the use conditions of a foam block product and to prepare the standards on the purpose of use.

Fire Experiment for a Water Curtain Nozzle in a Double Glazed Curtain Wall System (유리커튼월 수막시스템 분무헤드의 화재 실험 연구)

  • Kim, Sung-Won;Nam, Jiwoo;Cho, Seongwook;Ryou, Hong-Sun;Nam, Jun-Seok;Kim, Dong-Joon
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2016
  • Recently, a curtain wall system was applied to skyscrapers to prevent fire spreading along the vertical direction due to stack effect and outside air flow when a fire breaks out in skyscraper. Conventional sprinklers cannot prevent the spread of fire to the upstairs areas, which increases the loss of life and property. In this study, a water curtain nozzle that creates wider water coverage on the surface of glass and can prevent the spread of fire to the upstairs areas was developed. The spray pattern of the water curtain nozzle was compared with that of a sprinkler to determine performance of the water curtain nozzle. A fire experiment was constructed on the second floor to verify performance of the water curtain nozzle in preventing the spread of fire to the upstairs areas. The fire and watering experiment proved that the water curtain nozzle prevented more effectively the spread of fire than the conventional sprinkler. The position of first crack and critical temperature of fracture were also analyzed using numerical analysis.

Development of On-axis Raman Lidar System for Remotely Measuring Hydrogen Gas at Long Distance (원거리 수소 가스 원격 계측을 위한 On-axis 라만 라이다 장치 개발)

  • Choi, In Young;Baik, Sung Hoon;Lim, Jae Young;Cha, Jung Ho;Kim, Jin Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.3
    • /
    • pp.119-125
    • /
    • 2018
  • Hydrogen gas is an important and promising energy resource that has no emissions of pollutants during power generation. However, hydrogen gas is very dangerous because it is colorless, odorless, highly flammable, and explosive at low concentration. Conventional techniques for hydrogen gas detection are very difficult for measuring the hydrogen gas distribution at long distances, because they sample the gas to measure its concentration. Raman lidar is one of the techniques for remotely detecting hydrogen gas and measuring the range of the hydrogen gas distribution. A Raman lidar system with an on-axis optical receiver was developed to improve the range of hydrogen gas detection at long distance. To verify the accuracy and improvement in the range of detecting the hydrogen gas, experiments measuring the hydrogen gas concentration are carried out using the developed on-axis Raman lidar system and a gas chamber, to prevent explosion of the hydrogen gas. As a result, our developed on-axis Raman lidar system can measure a minimum hydrogen gas concentration of 0.66 volume percent at a distance of 50 m.

A Case of Intracranial Tuberculoma and Optic Disc Tuberculoma Suspected by Miliary Tuberculosis (속립성 결핵에서 발생된 것으로 사료된 두개내 및 시신경 유두부의 결핵성 육이종 1예)

  • Lim, Byung-Hun;Jeon, Kyeong-Hong;Cho, Yong-Kyun;Hang, Ki-Eun;Kim, Ki-Tack;Lim, Si-Young;Kim, Byeung-Ik;Lee, Sang-Jong;Lee, Byeung-Ro
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.236-242
    • /
    • 1996
  • Intracranial tuberculoma results from hematogenous spread of pulmonary, intestinal or urogenital tuberculosis. However, it might be caused by pulmonary tuberculosis, mainly. Clinically, symptoms of intracranial tuberculoma are headache and seizure, its symptoms are simillar to intracranial tumor. A 25-year-old-unmarried shopgirl was visited to this hospital because of headache, dizziness and visual disturbance for couple weeks in Sep. 1995. She had been treated with anti-tuberculosis agents of miliary tuberculosis during past nine months period. Brain MRI revealed intracranial tuberculoma and brain edema but not involved optic nerve. Ophthalmic examination revealed severe papilledema and splinter hemorrhage with bitemporal hemianopsis and central scotoma. This finding was strongly suggested of optic disc tuberculoma. Her symptoms became much better following repeated retrobulbar steroid injection with continuous anti-tuberculosis agents. We report a interesting case with intracranial tuberculoma and optic disc tuberculoma associated by miliary tuberculosis during anti-tuberculous treatment.

  • PDF