• Title/Summary/Keyword: 화염위치

Search Result 143, Processing Time 0.017 seconds

A study on the location of fire fighting appliances in cargo ships (화물선 소화설비 비치에 대한 연구)

  • Ha, Weon-Jae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.852-858
    • /
    • 2016
  • To safeguard the accommodation spaces on cargo ships from fire, structural fire protection provisions introduced by SOLAS and these measures retard the propagation of flames and smoke. SOLAS also specifies provisions for fire fighting drills. These provisions are a combination of regulations regarding structure and equipment and those dealing with the human element for the fire protection and effective responses in the event of fire. Requirements related to the human element play a supporting role to the requirements for structure and equipment because the present accommodation structure and equipment are insufficient for extinguishing a fire, therefore, fire-extinguishing activity performed by crew members is essential. To reduce human error and ensure effective fire fighting, it is necessary to install a fire-fighting system and improve the fire fighting process. The fundamental concept of fire fighting exercises is to commence fire fighting before the fire grows too big to extinguish. It is essential to relocate the storage place of fire fighting equipment to expedite the fire-fighting exercise. This study was carried out to reduce human risk for this purpose, the fire control station was relocated to a site that could be accessed from the open deck. Further, two sets of a fire fighter's outfit were stored at the same site. This relocation eliminated the risk of the crew reentering to operate the fire fighting system in the fire control station and allowed the crew to pick up the fire fighters' outfits quickly in the event of a fire. In addition, it was proposed that the IIC method be made mandatory. This method is combination of automatic fire detection system and sprinkler system which can reduce the risk of the fire fighting exercises for the crew and to suppress fire in the initial stage. This study was carried out to provide a foundation to the possible amendment of the relevant SOLAS regulations and national legislation.

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

Four Heavenly Kings Statues of Hoeamsa in the Early Joseon Dynasty: Seen Through Clay-Fragments Excavated From the Yangju Hoeamsa Site (양주 회암사지(楊州 檜巖寺址) 4단지 문지 출토 소조편(塑造片)을 통해 본 회암사 사천왕상)

  • SHIM, Yeoungshin
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.3
    • /
    • pp.168-191
    • /
    • 2021
  • This article examines the shape, iconography, and creation date of the Four Buddhist Heavenly Kings (Sacheonwang 四天王) enshrined in the Heavenly Kings' Gate (Cheonwangmun 天王門) of Hoeamsa in Yangju, Gyeonggi Province during the early Joseon Dynasty. First, small fragments of clay decoration excavated from a fourth-platform gate site of the Hoeamsa Temple Site in Yangju Gyeonggi Province were analyzed and compared to other Four Heavenly Kings enshrined in the (Cheonwangmun gates) during the Joseon Dynasty. In addition, the size and shape of the gate were compared to other Cheonwangmun gates constructed during the Joseon Dynasty. Results revealed that the excavated fragments were part of the armor of Sacheonwang, and the clay-standing statues enshrined in the fourth-platform gate of Hoeamsa Temple would be proportional in size to those of Beopjusa Temple in Boeum, South Chungcheong Province. The flame-type pieces, which decorated the Heavenly King's crown in the Joseon Dynasty, and the rectangular-type pieces were not found in artifacts from the Goryeo Dynasty. Therefore, the Sacheonwang sculptures of the Hoeamsa Temple were likely made in the late 15th century in the early Joseon Dynasty. A detailed iconography of the Sacheonwang of Hoeamsa is presumedly based on the Buddhist paintings and illustrations of Buddhist scriptures (Gyeongbyeonsangdo 經變相圖)from the late Goryeo and early Joseon. During the late Goryeo Dynasty and early Joseon Dynasty, Traditional iconography from Goryeo and new iconography from Ming coexisted. However, in the late 15th century, the Sacheonwang statues of the early Joseon Dynasty had many different elements from those of the Goryeo Dynasty and were similar to those enshrined in Cheonwangmun Gate during the Joseon Dynasty. The Four Heavenly Kings of Hoeamsa Temple, believed to have been produced in the late 15th century, has historical significance in the following points. They were the first Joseon Sacheonwang statues example enshrined in the Cheonwangmun gate. In addition, they were established as a new tradition that influenced the iconography of the Four Heavenly Kings during the Joseon Dynasty.