• Title/Summary/Keyword: 화상검사

Search Result 133, Processing Time 0.027 seconds

The Findings of Pulmonary Function Test in Patients with Inhalation Injury (흡입화상 환자에서의 폐기능검사 소견)

  • Kim, Jong Yeop;Kim, Cheol Hong;Shin, Hyun Won;Chae, Young Je;Choi, Chul Young;Shin, Tae Rim;Park, Yong Bum;Lee, Jae Young;Bahn, Joon-Woo;Park, Sang Myeon;Kim, Dong-Gyu;Lee, Myung Goo;Hyun, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.60 no.6
    • /
    • pp.653-662
    • /
    • 2006
  • Background: The changes in the pulmonary function observed in burn patients with an inhalation injury are probably the result of a combination of airway inflammation, chest wall and muscular abnormalities, and scar formation. In addition, it appears that prolonged ventilatory support and an episode of pneumonia contribute to the findings. This study investigated the changes in the pulmonary function in patients with inhalation injury at the early and late post-burn periods. Methods: From August 1, 2002, to August 30, 2005, surviving burn patients who had an inhalation injury were enrolled prospectively. An inhalation injury was identified by bronchoscopy within 48hours after admission. Spirometry was performed at the early phase during admission and the recovery phase after discharge, and the changes in the pulmonary function were compared. Results: 37 patients (M=28, F=9) with a total burn surface area (% TBSA), ranging from 0 to 18%, were included. The initial $PaO_2/$FiO_2$ratio and COHb were $286.4{\pm}129.6mmHg$ and $7.8{\pm}6.6%$. Nine cases (24.3%) underwent endotracheal intubation and 3 cases (8.1%) underwent mechanical ventilation. The initial X-ray findings revealed abnormalities in, 18 cases (48.6%) with 15 (83.3%) of these being completely resolved. However, 3 (16.7%) of these had residual sequela. The initial pulmonary function test, showed an obstructive pattern in 9 (24.3%) with 4 (44.4%) of these showing a positive bronchodilator response, A restrictive pattern was also observed in 9 (24.3%) patients. A lower DLco was observed in only 4 (17.4%) patients of which 23 had undergone DLco. In the follow-up study, an obstructive and restrictive pattern was observed in only one (2.7%) case each. All the decreased DLco returned to mormal. Conclusions: Most surviving burn patients with an inhalation injury but with a small burn size showed initial derangements in the pulmonary function test that was restored to a normal lung function during the follow up period.

VTR Head Inspection by using Image Processing Technique (화상처리기법을 이용한 비데오 헤드의 형상 검사)

  • Yoo, Young-Ki;No, Byeong-Ok;Oh, Chun-Suk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.4
    • /
    • pp.1074-1082
    • /
    • 1998
  • In one VTR(Video Tape Recorder), two or more heads are used to record or reproduce video signals. To obtain a uniform quality of a VTR, video heads should have similar characteristics such as geometrical shapes and electro-magnetic performances. This research is aimed to develop a visual inspection system measuring four geometrical parameters;H0,H1,Tw and CW. To obtain a high reliable results, image processing algorithms were developed. A series of experiments was performed for one thousands of video heads. From observation of the experimental results, the system is found to show excellent performance for inspection of video heads.

  • PDF

Comparison of FEA with Condition Monitoring for Real-Time Damage Detection of Bearing Using Infrared Thermography Techniques (적외선열화상을 이용한 베어링 실시간 손상검출 상태감시의 전산수치해석 비교)

  • Kim, Hojong;Kim, Wontae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.3
    • /
    • pp.185-192
    • /
    • 2015
  • Since real-time monitoring systems, such as early fault detection, have been very important, an infrared thermography technique was proposed as a new diagnosis method. This study focused on damage detection and temperature characteristic analysis of ball bearings using the non-destructive, infrared thermography method. In this paper, for the reliability assessment, infrared experimental data were compared with finite element analysis (FEA) results from ANSYS. In this investigation, the temperature characteristics of ball bearing were analyzed under various loading conditions. Finally, it was confirmed that the infrared thermography technique was useful for the real-time detection of damage to bearings.

Infrared Thermographic Monitoring for Failure Characterization in Railway Axle Materials (철도차량 차축 재료의 파괴특성 적외선열화상 모니터링)

  • Kim, Jeong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • The wheelset, an assembly of wheel and axle, is one of important parts in railway bogie, directly related with the running safety of railway rolling stock. In this investigation, the tensile failure behavior of railway axle materials was investigated. The tensile coupons were prepared from the actual rolling stock parts, which were operated over 20 years. The tensile testing was performed according to the KS guideline. During tensile testing, an infrared camera was employed to monitor temperature changes in specimen as well as demonstrate temperature contour in terms of infrared thermographic images. The thermographic images of tensile specimens showed comparable results with mechanical behavior of tensile materials. In this paper, the failure mode and behavior of railway axle materials were provided with the aid of infrared thermography technique.

Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique (적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출)

  • Yun, Kyung-Won;Kim, Dong-Lyul;Jung, Hyun-Chul;Hong, Dong-Pyo;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • In the advanced research deducted infrared thermography (IRT) test using 4 inch pipe with artificial wall-thinning defect to measure on the wall-thinned nuclear pipe components. This study conducted for defect detection condition of nuclear small-bore pipe research using deducted condition in the advanced research. Defect process is processed by change for defect length, circumferential direction angle, wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and Target pipe experiment performed to the distance of the changed 1 m, 1.5 m, 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. artificial defect of 4 inch pipe is high reliability in the 2 m, but small-bore pipe is in the 1.5 m from the defect clearly was detected.

Shearing Phase Lock-in Infrared Thermography for Defects Evaluation of Metallic Materials Specimen (금속재료 시편의 결함평가에 대한 전단위상 Lock-in 적외선열화상 연구)

  • Park, Jeong-Hak;Choi, Man-Yong;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.91-97
    • /
    • 2010
  • This paper proposes method to evaluate the location and size of the internal defects of metallic specimens by the shearing phase lock-in infrared thermography. Until now, infrared thermography test for metal specimen of STS304 and Cu-Zn were conducted to find the best test conditions. However, In unspecified situation of the form and existence of defects, there was a disadvantage to takes a long time for finding the optimal experimental conditions. The defect detection and evaluation was performed at 60 MHz signal using lock-in and shearing-phase method under limited heating conditions. By shearing-phase distribution method, Defects for the maximum, minimum and zero points were quantitatively detected at the size and location of the subsurface. As results, application of the proposed technique was verified for STS304 and Cu7-Zn3 with artificial defect and factors affected defect evaluation were searched and analyzed.

Development of Control Library of Inspection System using OPC (OPC를 이용한 검사장비 제어 라이브러리 개발)

  • Han, Chang-Ho;Park, Seong-Soo;Oh, Choon-Suk
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10a
    • /
    • pp.244-247
    • /
    • 2006
  • 본 논문에서는 검사장비에 제어용 라이브러리를 연구, 개발을 하였다. 개발된 라이브러리는 OPC 클라이어트, 스테이지 구동, 스위치 구동, 현미경 구동, 화상처리, 얼라이먼트, 태스크 관리로 나뉘며, 라이브러리 테스트 프로그램을 개발하여 모든 라이브러리의 기능 구현 테스트를 실시하고 있다. 제어 시스템 분야에서 세계 표준인OPC 개념을 도입하여, 검사 장비의 PLC 프로그램과 네트워크를 통해 데이터를 주고, 받을 수 있도록 OPC 서버를 사용하여 데이터를 관리하였다. 실제 검사장비에 탑재하기 전에 성능테스트를 위해PLC에 테스트 프로그램을 입력하여 실험을 하였다.

  • PDF

Effect of Polysaccharide from Schizophyllum commune on Burn and Wound Healing (치마버섯 유래 다당체의 화상 및 상처 치유효과)

  • Kim, Min Kyoung;Hong, Eock Kee
    • Korean Chemical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.87-91
    • /
    • 2006
  • Polysaccharides extracted from mushroom have been most commonly used to enhance the immune system. Also polysaccharides maintaining the moisture extent on epidermal tissue have an effect on the removal of necrotic tissue and the restoration of epidermal tissue through enhancing the immune system at skin layers. In this work, polysaccharides were from Schizophyllum commune studied about the burn and wound healing activity in the epidermal tissue on rats through in vivo experiment and hematological values. And antibacterial activities were examined using pathogenic microorganisms causing the secondary inflammation.

Design of Remote Early Dementia Diagnosis Systems (원격 치매 조기 진단 시스템 설계)

  • Choi, Jongmyung;Jeon, Gyeong-Suk;Kim, Sunkyung;Choi, Jungmin;Rhyu, Dong Young;Yoon, Sook
    • Journal of Internet of Things and Convergence
    • /
    • v.6 no.4
    • /
    • pp.27-32
    • /
    • 2020
  • Along with the aging of the population, the number of dementia patients is increasing, and the social and economic burden is also increasing. Currently, the effective way to manage dementia patients is to identify patients with dementia early. However, in rural and island areas where medical staff are scarce, there is a problem that it is difficult to visit a hospital and get an early examination. Therefore, we propose a remote early detection system for dementia to solve the problems. The remote dementia early diagnosis system is a system that allows a patient to receive examination and treatment from a remote dementia expert using remote medical technology based on real-time image communication. The remote early diagnosis system for dementia consists of a local client system used by medical staff at health centers in the island, an image server that transmits, stores and manages images, and an expert client used by remote dementia experts. The local client subsystem satisfies the current medical law's remote collaboration by allowing the patient to use it with the health center's medical staff. In addition, expert clients are used by dementia experts, and can store/manage patient information, analyze patient history information, and predict the degree of dementia progression in the future.