Prediction of Maintenance Period of Equipment Through Risk Assessment of Thermal Power Plants (화력발전설비 위험도 평가를 통한 기기별 정비주기 예측)

  • Song, Gee Wook;Kim, Bum Shin;Choi, Woo Song;Park, Myung Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.10
    • /
    • pp.1291-1296
    • /
    • 2013
  • Risk-based inspection (RBI) is a well-known method that is used to optimize inspection activities based on risk analysis in order to identify the high-risk components of major facilities such as power plants. RBI, when implemented and maintained properly, improves plant reliability and safety while reducing unplanned outages and repair costs. Risk is given by the product of the probability of failure (POF) and the consequence of failure (COF). A semi-quantitative method is generally used for risk assessment. Semi-quantitative risk assessment complements the low accuracy of qualitative risk assessment and the high expense and long calculation time of quantitative risk assessment. The first step of RBI is to identify important failure modes and causes in the equipment. Once these are defined, the POF and COF can be assessed for each failure. During POF and COF assessment, an effective inspection method and range can be easily found. In this paper, the calculation of the POF is improved for accurate risk assessment. A modified semi-quantitative risk assessment was carried out for boiler facilities of thermal power plants, and the next maintenance schedules for the equipment were decided.

A Study on Integrated Reliability Analysis for Fossil Power Plant (화력발전 플랜트의 신뢰도 산정기법에 관한 기초연구)

  • Lee, Seung-Chul;Park, Kyung-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.178-180
    • /
    • 1999
  • 본 연구는 발전소의 신뢰도 산정을 보다 정확히 하기 위한 기초를 마련하기 위해 수행되었다. 많은 설비들로 구성된 발전소의 전체 신뢰도 계산에 대한 정확한 이론체계가 아직까지 확립되지 않았고 고장의 발생빈도도 적어 신뢰도 분석의 정확도에 한계가 있다. 또한 발전소의 기기수리 및 정기적인 전체정비가 신뢰도에 미치는 영향도 신뢰도 산정시 고려해야한다. 본 연구에서는 전형적인 국내발전소의 실제 고장정지와 수리 데이터에 기초하여 발전소의 고장시간 분포와 수리시간 분포 분석의 예를 보였고 적은 표본수로도 분포 parameter들의 계산이 가능한 Weibull 분포의 적용 가능성을 제시하였다. 또한 고장수리 및 전체정비가 신뢰도에 미치는 영향을 반영하기 위해 stochastic renewal process에 기초한 availability의 적용을 제안하고 그 예를 보였다.

  • PDF

Electrical Characteristics and System Efficiency of the 5.9kW Phosphoric Acid Fuel Cell Power Generation System (소형 인산형 연료전지발전 시스템의 출현 및 효율 특성)

  • 정두환;이원용;이선근;임희천;신동열;최수현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.90-95
    • /
    • 1993
  • 수력, 화력, 원자력 다음으로 제 4의 전원으로서 관심의 대상이 되고 있는 연료전지는 연료가 가지고있는 화학에너지를 직접에너지로 변환시키는 점에서 종래의 발전 기술과는 원리적으로 다르며, 카르노(Carnot)사이클에 의한 에너지 변환 효율의 제한을 받지 않기 때문에 효율이 높으며 공해가 없는 특징을 가지고 있다. 연료전지의 발전 방식은 작동 온도, 전해질 등에 의해서 분류되나 현재 실용화단계의 기술은 인산형연료전지 발전이다. 인산형 연료전지의 발전용 연료는 천연가스, 메탄올, 납사 등과 같은 탄화수소 계열의 다양한 연료를 사용할 수 있으며, 이들 연료들을 수소가 많이 함유된 가스로 변환시켜 연료전지에 공급하여야 한다. 연료전지발전시스템 개발은 주로 전력이용 측면에서 천연가스를 개질연료로 사용하는 연구가 주류를 이루었으나, 최근에는 전 세계적으로 대기 공해에 시달리고 있는 도시의 환경개선을 위하여 도심용 버스 및 대형 트럭 등에 응용하기 위한 무공해 수송용 자동차엔진의 개발, 국방용 이동전원 개발 및 100㎾ 미만의 현지설치용 및 낙도용 전원으로서 메탄올을 연료로 한 연료전지의 개발이 활발히 진행되고 있다. 한국에너지기술연구소는 한국전력 기술연구원과 공동으로 1989년부터 1992년까지 본체를 제외한 5.9㎾급 인산형 연료전지 발전시스템 즉, 메탄올 연료 개질장치, 운전자동화 시스템, 배열이용 시스템, 종합 배관 등을 설계 구성하여 발전 플랜트의 운전 특성 연구를 수행하였으며, 본 고에서는 이들 설비들의 운전 특성과 발전 플랜트로서의 효율 특성에 대한 고찰을 수행하였다. 본 시스템은 연료개질기가 연결되고 배열을 이용하는 국내최초의 종합적인 연료전지 발전 시스템으로서 개질된 연료로 운전하였을 경우 본체의 효율은 31.9%, 배열을 회수한 종합발전 플랜트의 효율은 45.2%였다.로서, 흰쥐 유선이 LH의 생성처이면서 동시에 작용처이며 유선에서 합성된 GnRH의 조절하에 국부적인 인자로 작용할 가능성을 시사한다.f variation)가 10% 내외로 만족할 만한 범위에 들었다. 본 실험 방법을 타액과 혈청내 testosterone 농도 측정에 응용하여 RIA의 결과와 비교하여 본 바 상관관계가 타액에서 r=0.969, 혈청에서 r=0.990으로 두 결과가 잘 일치하였다. 본 실험에서 측정된 한국인 여성의 타액내 testosterone농도는 107.7$\pm$12.0 pmol/l이었고, 남성의 타액내 농도는 274.2$\pm$22.1 pmol/l이었다. 이상의 결과로 보아 본 연구에서 정립된 EIA 방법은 RIA를 대신하여 소규모의 실험실에서도 활용할 수 있을 것으로 사려된다.또한 상실기 이후 배아에서 합성되며, 발생시기에 따라 그 영향이 다르고 팽창과 부화에 관여하는 것으로 사료된다. 더욱이, 조선의 ${\ulcorner}$구성교육${\lrcorner}$이 조선총독부의 관리하에서 실행되었다는 것을, 당시의 사범학교를 중심으로 한 교육조직을 기술한 문헌에 의해 규명시켰다.nd of letter design which represents -natural objects and was popular at the time of Yukjo Dynasty, and there are some documents of that period left both in Japan and Korea. "Hyojedo" in Korea is supposed to have been influenced by the letter design. Asite- is also considered to have been "Jap

  • PDF

The Effect of Multi-Coal Combustion on the Generation of Slagging in a Bituminous Coal-fired Power Plant Boiler (연탄 화력발전소 보일러에서 다탄종 연소가 슬래깅 발생에 미치는 영향)

  • Park, Jihoon;Yoo, Hoseon
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.55-61
    • /
    • 2022
  • In this study, I analyzed the effect of slagging caused by blending bituminous coal and subbituminous coal while maintaining the generator output, combustion conditions, and ventilation conditions for 870MW thermal power plant designed with bituminous coal. Accordingly I proposed an acceptable method of blending coal method. the blending ratio of sub-bituminous coal was adjusted to 10%, 20%, 40%, 60%, 80%, etc. to confirm ultimate analysis, proximate analysis, ash fusion temperature change, slagging indices, etc. Proper blending coal conditions are blending with sub-bituminous coal at 40% or less, ratio of base component to acid component(B/A) is 0.4 or less or 1 or more, total alkali(TA) is 3.5 or less, fusion slagging index(Rfs) is 1,345℃ or more, and ash content is 13% or less in ultimate analysis, the ash content in proximate analysis is 15% or less, and the initial deformation temperature(IDT) should be at least 1,200℃ or more

  • PDF

Estimation of Washing Duration of Desulfurized Absorber in a Heavy Oil Power Plant (중유화력발전소 탈황 흡수탑 세정시기예측)

  • Jang, Yeong Gi;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.1
    • /
    • pp.24-28
    • /
    • 2016
  • In desulfurization facilities of oil-fired power plant, gypsum scale is attached in the absorber inner surface as the operating time increases. For this reason, the maximum possible load of the power generation is set down, resulting in further generation stop. Cleaning of absorber for scale removal can be determined at the time of setting down of the maximum possible load. In this study, 6 weeks before the maximum possible load of the power generation was down set, at the same time and desulfurization facilities outlet $SO_2$ concentration value was more than 130ppm, absorber differential pressure exceeded $380mmH_2O$, it was confirmed to be the time that has elapsed 44 weeks after the previous absorber cleaning. Cleaning time of the absorber was predicted to be a time which has elapsed 50 weeks from the previous cleaning time.

  • PDF

Effect of Carbon Capture Using Pre-combustion Technology on the Performance of Gas Turbine Combined Cycle (연소전 처리를 이용한 탄소포집이 가스터빈 복합화력 플랜트의 성능에 미치는 영향)

  • YOON, SUKYOUNG;AHN, JIHO;CHOI, BYEONGSEON;KIM, TONGSEOP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.571-580
    • /
    • 2016
  • In this paper, performance of the gas turbine combined cycle(GTCC) using pre-combustion carbon capture technology was comparatively analysed. Steam reforming and autothermal reforming were used. In the latter, two different methods were adopted to supply oxygen for the reforming process. One is to extract air form gas turbine compressor (air blowing) and the other is to supply oxygen directly from air separation unit ($O_2$ blowing). To separate $CO_2$ from the reformed gas, the chemical absorption system using MEA solution was used. The net cycle efficiency of the system adopting $O_2$ blown autothermal reforming was higher than the other two systems. The system using air blown autothermal reforming exhibited the largest net cycle power output. In addition to the performance analysis, the influence of fuel reforming and carbon capture on the operating condition of the gas turbine and the necessity of turbine re-design were investigated.

Effect of Fuel Mixing Ratio on Fuel Consumption in a Oil Fired Power Plant (중유화력발전소에서 바이오연료 혼합연소가 연료소비량에 미치는 영향)

  • Hong, Sangpil;Yoo, Hoseon
    • Plant Journal
    • /
    • v.12 no.3
    • /
    • pp.39-45
    • /
    • 2016
  • Each of fuel consumption per hour was measured at the 320 MW and 380 MW generator output while changing mixing ratio of bio fuel oil to 50%, 80% and 100%. Fuel consumption per hour was increased from 11.0% to 20.4% as mixing ratio of bio fuel oil was changed from 50% to 100% at the 320 MW generator output comparing with fuel consumption per hour in case of bunker-C oil single firing. Fuel consumption per hour was also increased from 12.0% to 21.1% as mixing ratio of bio fuel oil was changed from 50% to 100% at the generator output 380 MW. Furthermore, it was confirmed that plant efficiency was decreased as mixing ratio of bio fuel oil was increased from 50% to 100% as a result that plant efficiency was calculated using the measured fuel consumption per hour, the generator output and the gross heating value.

  • PDF

Variation of Liquid to Gas Ratio and Sulfur Oxide Emission Concentrations in Desulfurization Absorber with Coal-fired Thermal Power Plant Outputs (석탄화력 발전설비의 출력에 따른 탈황 흡수탑 액기비와 황산화물 배출농도 변화에 대한 연구)

  • Kim, Kee-Yeong;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.39-47
    • /
    • 2018
  • In this research, when the output of the standard coal-fired thermal power plant operating continuously at the rated output of 500 MW is changed to operate at 300 to 500 MW, the amount of sulfur oxide produced and the amount of sulfur oxide in the absorption tower of desulfurization equipment and proposed an extra liquid to gas ratio improvement inversely proportional to the output. In order to calibrate the combustion efficiency at low power, the ratio of sulfur oxides relative to the amount of combustion gas is increased as the excess air ratio is increased. When the concentration of sulfur oxide at the inlet of the desulfurization absorber was changed from 300 to 500 ppm along with the output fluctuation. The liquid to gas ratio of limestone slurry and combustion gas was changed from 10.99 to 16.27. Therefore, if the concentration of sulfur oxides with output of 300 MW is x, The following correlation equation is recommended for the minimum required flow rate of slurry for the reduction of surplus energy due to the increase of the liquid weight at low load. $y1[m^3/sec]=0.11x+3.74$

  • PDF

Engineering design procedure for gas turbine combined cycle power plant with post-combustion CO2 capture (CO2 포집을 고려한 가스터빈 복합화력 발전 플랜트의 시스템 대안 평가를 위한 공학 설계)

  • Lee, Soohyeon;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.333-335
    • /
    • 2014
  • As the user demand for power plants becomes various, design objective becomes complicated. To review the system feasibility, system objective and evaluation criteria need to be newly defined. In this study, engineering design procedure of the multi-purpose power plant, such as barge-mounted combined cycle power plant with $CO_2$ capture, was shown as a previous work for the feasibility review of the system alternatives. For the system design, heat and mass balance for each system configuration was firstly performed. Using the thermal analysis results, conceptual design of system alternatives was carried out. And then, preliminary design of the major equipment was done. The engineering calculation results of this study would be used as the evaluation data for system feasibility review.

  • PDF

New Directions of Particulate Control Technology (새로운 집진기술 동향)

  • 김용진;정상현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.221-231
    • /
    • 1995
  • 산업발달에 따라 불가피하게 생성되며, 대기오염의 주종을 이루면서 인체에 가장 유해한 분진입자는 산업체의 오일(oil) 및 석탄연소 보일러, 자동차, 제철/제강 및 시멘트 플랜트 등으로 부터 배출되는 미세입자(fine particle)들이며, 앞으로 이들의 제어에 관한 연구가 지속적인 관심의 대상이 될 것이다. 한 예로, 석탄연소 화력발전소로부터 1$\mum$ 이하의 입자들의 배출량은 무게비로는 1% 이하이지만 입자수의 비율에서는99%를 차지하고 있다. 이들은 매우 높은 중금속 함유량을 지니고 있기 때문에 인체의 호흡시 심각한 문제를 유발시킬 뿐만 아니라, 이러한 미세입자들은 대기중에 부유하고 있다가 비(rain)에 의하여 세정되어 수질오염까지도 유발시킨다. 1992년 2월 공포된 대기환경보전법 시행규칙에 따라 분진배출 허용기준이 장기 입법예고 되므로서 1995년 1월과 1999년 1월의 2단계에 걸쳐 현재 적용 받고 있는 분진배출 규제치보다 훨씬 낮은 선진국 수준의 분진배출 규제가 요구되고 있으며, 분진이 배출되는 인근지역주민의 민원에 대처하기 위해서는 연돌로부터 분진배출이 눈에 감지되지 않을 정도까지 분진배출농도를 관리해야할 필요성이 높아지고 있다. 이에 따라 집진장치의 효율도 중유전소 Boiler 의 경우는 90% 이상, 석탄전소 Boiler의 경우는 99.5% 이상의 고효율이 요구되고 있다.

  • PDF