• Title/Summary/Keyword: 홍수저감효과

Search Result 268, Processing Time 0.025 seconds

An Application of Infiltration Facilities for Reducing the Runoff in the Basin (유출저감을 위한 유역내 침투시설의 적용)

  • Lee, Jae-Joon;Seol, Ji-Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.133-141
    • /
    • 2011
  • Urban development of basin causes increasing runoff volume and peak flowrate and shortening in time of concentration, which may cause frequent flooding downstream. An infiltration facilities are operated as a method of reducing flood discharge of urban rivers and peak flowrate. There are various types of infiltration facilities like infiltration trench and porous pavement. In this study, runoff reduction effect due to installation of infiltration facilities are performed and focused on $0.18km^2$ residential area of Ok-kye dong and $0.67km^2$ industrial area of Gong-dan dong in Gumi City. The analysis is fulfilled with comparison of total runoff volume and runoff reduction volume by using the WinSLAMM and the relation equation between area ratio of infiltration facilities and ratio of runoff reduction are derived and peak flow reduction effect for installation of infiltration facilities is analyzed.

A study on the determination of location of the detention pond in trunk sewer for reducing runoff amounts (우수유출저감을 위한 간선저류지 위치선정에 관한 연구)

  • Lee, Sung Ho;Yoon, Sei Eui;Lee, Jae Joon
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.4
    • /
    • pp.223-232
    • /
    • 2017
  • The ability to defend against floods in urban areas was weakened, because the increase in the impervious rate of urban areas due to urbanization and industrialization and the increase in the localized torrential rainfall due to abnormal climate. In order to reduce flood damage in urban areas, various runoff reduction facilities such as detention ponds and infiltration facilities were installed. However, in the case of domestic metropolitan cities, it is difficult to secure land for the installation of storm water reduction facilities and secure the budget for improving the aged pipelines. Therefore, it is necessary to design a storage system (called the detention pond in trunk sewer) that linked the existing drainage system to improve the flood control capacity of the urban area and reduce the budget. In this study, to analyze the effect of reducing runoff amounts according to the volume of the detention pond in trunk sewer, three kinds of virtual watershed (longitudinal, middle, concentration shape) were assumed and the detention pond in trunk sewer was installed at an arbitrary location in the watershed. The volume of the detention pond in trunk sewer was set to 6 cases ($1,000m^3$, $3,000m^3$, $5,000m^3$, $10,000m^3$, $20,000m^3$, $30,000m^3$), and the installation location of the detention pond in trunk sewer was varied to 20%, 40%, 60%, and 80% of the detention pond upstream area to the total watershed area (DUAR). Also, using the results of this study, a graph of the relationship and relational equation between the volume of the detention pond in trunk sewer and the installation location is presented.

Reduction of Rainfall Runoff by Constructing Underground Storage Tank (지하저류조 신설에 따른 우수 유출량 저감)

  • Song, Chang Geun;Seo, Il Won;Jung, Young Jai
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.927-935
    • /
    • 2013
  • In this study, reservoir routings for 1 hour-50 year precipitation frequency were carried out at the Engineering Water Fall and the Amphitheater located at the downstream of Seoul National University Dam. Main analysis was focus on the following matters: (1) storage amount by the tank; (2) reduction of the outflow and the peak water surface elevation; (3) change of phase lag time; and (4) design of new boxes at the inlet and outlet of storage tank. As for the storage tank of $25,000m^3$ built in the Amphitheater area, the tank induced 49.43 % storage effect, 28 min. phase lag time, and reduced the peak outflow by 49.64 %. In addition, the peak water surface elevation was lowered by 35 cm compared with that of $15,000m^3$ storage tank. It is concluded that combined management of previous storage facility and new underground storage tank would control the excessive rainfall runoff efficiently.

Development of the Urban Flood Forecasting System Considering Integrated Inland-River System (내외수 연계 도시홍수 예보시스템 개발)

  • Kim, Jong-Suk;Kwon, Hyun-Han;Yoon, Sun Kwon;Jun, Kyung Soo;Moon, Young-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.3-3
    • /
    • 2016
  • 기후변화로 태풍, 집중호우 등의 발생빈도가 높아져 도시지역에서 홍수범람으로 인한 인명피해와 재산상의 손실이 반복되고 있으며, 이로 인한 사회기반시설에 대한 피해가 급증하고 있다. 따라서 이를 효과적으로 방어할 수 있는 구조적, 비구조적 내배수 홍수방어 대책의 수립이 시급한 실정이다. 도시유역에서의 침수피해는 내부배제 불량에 따른 내수침수가 대부분을 차지하고 있으며 효과적인 내수침수예측 및 홍수피해 저감을 위한 방재시스템 구축을 위해서는 내외수를 연계한 침수 예측 선진화 기술개발이 필요하다. 따라서 본 섹션에서는 레이더 및 위성 정보를 활용한 초단기 또는 단기 강우예측 기술개발, 하수관망 단순화 자동화 기술 개발, 베이지안 모형과 연계한 SWMM모형의 매개변수최적화, 내수침수 대응을 위한 동적의사결정 모형 등의 핵심기술을 통합한 내외수를 연계한 도시홍수예보시스템 개발내용과 실강우사상에 대한 적용성 검토 결과를 소개하고자 한다. 본 연구의 성과는 실시간 또는 예측강우분석을 통하여 돌발홍수로 인한 내수침수피해에 대한 골들타임을 확보하고 대피지구 선정 및 주민의 대피이동 정보제공 등 도시홍수로부터 발생하는 피해에 대한 최적화된 선제적 대응체계 구축에 활용도가 높을 것으로 기대된다.

  • PDF

A Study on Urban Inundation Prediction Using Urban Runoff Model and Flood Inundation Model (도시유출모형과 홍수범람모형을 연계한 내수침수 적용성 평가)

  • Tak, Yong Hun;Kim, Jae Dong;Kim, Young Do;Kang, Boosik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.395-406
    • /
    • 2016
  • Population and development are concentrated by urbanization. Consequently, the usage of underground area and the riverside area have been increased. By increasing impermeable layer, the urban basin drainage is depending on level of sewer. Flood damage is occurred by shortage of sewer capacity and poor interior drainage at river stage. Many of researches about flood stress the unavailability of connection at the river stage with the internal inundation organically. In this study, flood calculated considering rainfall and combined inland-river. Also, using urban runoff model analyze the overflow of sewer. By using results of SWMM model, using flood inundation analysis model analyzed internal drainage efficiency of drainage system. Applying SWMM model, which results to flood inundation analysis model, analyzes internal drainage efficiency of drainage system under localized heavy rain in a basin of the city. The results of SWMM model show the smoothness of internal drainage can be impossible to achieve because of the influence of the river level and sewer overflow appearing. The main manholes were selected as the manhole of a lot of overflow volume. Overflow reduction scenarios were selected for expansion of sewer conduit and instruction retention pond. Overflow volume reduces to 45% and 33~64% by retention pond instruction and sewer conduit expansion. In addition, the results of simulating of flood inundation analysis model show the flood occurrence by road runoff moving along the road slope. Flooded area reduces to 19.6%, 60.5% in sewer conduit expansion scenarios.

Reduction Rate of the Total Runoff Volume though Installing a Rainfall Storage Tank in the Sub-Surface (지하 빗물저류시설의 설치에 따른 유출 저감 효과 분석)

  • Choi, Gye-Woon;Choi, Jong-Young;Li, Jin-Won
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.3 s.134
    • /
    • pp.455-464
    • /
    • 2003
  • In this paper, the experiments with installing a rainfall storage tank in the sub-surface were conducted and the reduction rates of the total runoff volume were investigated. The analysis were conducted based upon the variations of the rainfall intensity, surface coverage and surface slope. The reduction rate of the runoff volume was varied from 42.3% to 52.9% with the soil in the bank of the Seung Gi stream. In the experiments, the rainfall intensities were varied from 40mm/hr to 100mm/hr and the results indicate that the direct runoff reduction can be obtained with the installation of the rainfall storage tank in the sub-surface. The variation of the stored volume in the tank is very large in the mild slope but very small in the steep slope with over 3% slope. With this results, the reduction of the direct runoff volume for the longtime flood is expected with the installation of the rainfall storage tank in the region haying the steep slope such as the mountain area.

Flux Profile Method for Evaluating the thermal Efficiency of Green roof (Flux Profile Method를 적용한 옥상녹화의 열효율 성능 평가)

  • Kwon, You Jeong;Seo, YongWon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.320-320
    • /
    • 2022
  • 기후변화와 도시화로 인한 영향으로 도시의 폭우, 폭염을 비롯한 현상이 빈번하게 발생하고 있다. 특히 시가화 지역의 높은 불투수율은 도시홍수를 야기한다. 이러한 현상을 완화하기 위해 도시지역에서는 그린인프라와 저영향개발이 도입되고 있다. 그 중 지속가능한 발전을 위한 필수요소로 자리매김한 옥상녹화는 도시에 위치한 건물의 상층부와 내부의 온도를 낮춤으로써 에너지절감효과와 강우 시 빗물을 저류함으로써 우수유출 저감효과, 그리고 도시 공간 내 녹지도입으로 인한 이산화탄소 배출 저감 효과 등을 기대할 수 있다. 본 연구에서는 열섬현상완화와 유출 저감의 방안 중 하나인 옥상녹화(Green roof)의 효과를 정량적으로 평가하기 위해 콘크리트로 이루어진 동일한 제원의 실험동을 구축하고, 실험동 내외부의 온도, 습도, 강우, 풍속, 일사량 등의 기상자료를 측정할 수 있는 센서를 설치하였다. 각 실험동에서 측정된 기상요소를 Flux Profile Method를 적용하여 공간 내에 있는 열에너지의 총량인 순복사열을 구성하는 현열속, 잠열속, 토양열속(H, LE, G)을 산정하였다. 또한 에너지 평형에 따라 산정된 각 실험동의 열속과 지표면 복사량 관측자료을 정량적으로 비교하여 옥상녹화의 적용성을 평가하였다. 2021년 7월 21일부터 2021년 7월 28일 까지 모니터링한 결과 옥상녹화의 열 효율은 일반 콘크리트 지붕에 비해 실내온도가 최대 6.83℃ 낮게 나타나며 이는 여름철 건물 내부의 온도조절에 필요한 에너지 저감효과를 볼 수 있다. Flux Profile Method를 적용한 결과 옥상녹화의 전체 열속 중 현열속 28.5% 잠열속 70.7%, 토양열속 0.5% 의 복사량 분포를 보였고, 일반 콘크리트 지붕은 현열속 45.3%, 잠열속 38.6%, 토양열속 16.2% 으로 나타났다. 이와 같은 방법은 옥상녹화의 정량적 평가를 가능하게 함으로서 향후 기후변화 대응방안 및 전략 수립 시 옥상녹화의 온도저감효과 분석에 적극 활용할 수 있을 것으로 판단된다.

  • PDF

Wrinkle Reduction Design Method of Triangular Solar Sail (삼각형 태양돛의 주름저감 설계방안)

  • Bae, Hongsu;Woo, Kyeongsik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.12
    • /
    • pp.940-949
    • /
    • 2013
  • In this paper, wrinkle reduction design was studied for triangular sail. Wrinkles in the solar sail membrane can change the load path and surface topology which may have an adverse effect on propulsion performance and controllability. In this study, wrinkle reduction strategies of adjusting cable angle, catenary and catenary-wire schemes were considered and the design parameters for wrinkle reduction were systematically investigated.

Implementation of Flood Warning Service with Mobile GIS (모바일 GIS를 이용한 홍수 위험 경보 서비스 구현)

  • Park, Jong-Duk;Ku, Cha-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.46 no.6
    • /
    • pp.738-750
    • /
    • 2011
  • Partly due to the climate changes, flooding occurs more often than before. Particularly high urbanization causes more damages by flooding with unexpected downpours. Recent mobile telecommunication technology can help to reduce the damage by a natural disaster with quick alarming process. This research aimed to implement a flood warning GIS service system based on open source software and mobile hybrid application program with LBS. The developed system utilized location information of mobile clients for smart phone users to get alerted to flooding immediately. This service system would be very useful in urban areas to reduce the flood damages.

Evaluation and Analysis on the Effects of Flood Damage Mitigation according to Installation on Deep Underground Rainwater Tunnel (대규모 터널형 빗물저류배수시설 설치에 따른 침수피해저감 효과 평가 및 분석)

  • Myung Hoon Lee;Jun Han Bae;Jun Bae Hong;Soo Jin Moon;Ji Hyeok Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.365-365
    • /
    • 2023
  • 우리나라는 지리, 지형 및 기상특성으로 인해 집중호우와 태풍 등으로 자연재해 피해를 입고 있으며, 재해예방사업의 일환으로 1998년부터 자연재해위험개선지구 정비사업을 통해 자연재해로부터 침수, 유실, 붕괴위험 등 피해예방을 위해 노력하고 있다. 서울특별시는 도시화로 인한 우수침투 가능지역 감소와 유역경사 부족에 따른 충분한 관거 경사확보의 어려움으로 저지대에 노면수가 집중되면서 대규모 침수피해(2010. 09, 2011. 07)가 발생되었으며, 신월·신정지구 및 화곡2지구가 자연재해위험개선지구로 선정(2011. 04), 침수방지를 위한 대책으로 국내 최초의 대규모 터널형 빗물저류배수시설(신월빗물저류배수시설)을 준공(2020. 05)하였다. 본 연구에서는 신월빗물저류배수시설 설치에 따른 상습침수구역의 사업 전·후 침수피해 저감효과 검증을 위해 도시유출모형을 구축하여 서울시 방재성능목표 확보여부를 판단하고자 하였다. 기존 설계 당시 서울시 방재성능목표(30년 빈도, 95mm/hr)는 확보되었으나 이를 초과하는 강우(2010. 09, 98.5mm/hr)가 발생함에 따라 수행된 추가 분석(100mm/hr) 결과, 유역의 침수 완전해소를 위해서는 빗물저류배수시설과 더불어 국부적인 간선관거 개량의 필요성이 제시되었다. 이에 따라 본 연구에서는 도시유출모형 구축 시 최근 개선된 하수관로, 지형특성, 홍수량산정표준침(2019, 환경부)등에 따른 수리·수문특성을 반영하고, 신일펌프장(간이)을 추가적으로 고려하여 현재 기준에서의 침수피해 저감 효과를 면밀이 분석하였으며, 그 결과 서울시 방재성능목표 뿐만 아니라 100mm/hr에도 침수가 완전 해소되는 것으로 나타났다. 신월빗물저류배수터널 설치에 따른 침수피해 저감효과 평가 및 분석결과를 통해 자연재해위험개선지구의 해제가 가능할 것으로 판단되며, 지역안전·환경효과, 주민만족도 등 다양한 항목에 대하여 상습침수구역 내 주민설문조사를 수행한 결과 신월빗물저류배수터널에 대한 만족도가 충분히 제고된 만큼 향후 시설의 기능적, 운영적 측면에서의 유지관리가 잘 이루어진다면 침수로부터 안전한 도시를 구현하는데 큰 역할을 할 것으로 기대된다.

  • PDF