• Title/Summary/Keyword: 혼합물 법칙

Search Result 36, Processing Time 0.021 seconds

Measurement of Flash Point for Binary Mixtures of 2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane, and Toluene at 101.3 kPa (2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane 그리고 Toluene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • For the design of the prevention and mitigation measures in process industries involving flammable substances, reliable safety data are required. An important property used to estimate the risk of fire and explosion for a flammable liquid is the flash point. Flammability is an important factor to consider when developing safe methods for storing and handling solids and liquids. In this study, the flash point data were measured for the binary systems {2-butanol + 2,2,4-trimethylpentane}, {2-butanol + methylcyclohexane} and {2-butanol + toluene} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a Stanhope-Seta closed cup flash point tester. A minimum flash point behavior was observed in the binary systems as in the many cases for the hydrocarbon and alcohol mixture that were observed. The measured flash points were compared with the predicted values calculated via the following activity coefficient (GE) models: Wilson, Non-Random Two-Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC) models. The predicted data were only adequate for the data determined by the closed-cup test method and may not be appropriate for the data obtained from the open-cup test method because of its deviation from the vapor liquid equilibrium. The predicted results of this work can be used to design safe petrochemical processes, such as the identification of safe storage conditions for non-ideal solutions containing flammable components.

The Estimation of Lower Flash Point for n-Pentanol+n-Propionic Acid and n-Pentanol+n-Butyric Acid Systems Using Optimization Method (최적화 기법을 활용한 n-pentanol+n-propionic acid 및 n-pentanol+n-butyric acid계의 하부 인화점 추산)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.73-78
    • /
    • 2007
  • The lower flash points for the n-pentanol+n-propionic acid and n-pentanol+n-butyric acid systems, in air at atmospheric pressure, were measured by using Pensky-Martens closed cup apparatus. The experimental data were compared with the values calculated by the Raoult's law and optimization method. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

  • PDF

The Measurement of Minimum Flash Point Behaviour (MFPB) for Binary Mixtures (이성분계 혼합물의 최소인화점 현상의 측정)

  • Hong, Soon-Kang;Yoon, Myung-O;Lee, Sung-Jin;Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • The flash point is an important indicator of the flammability of a chemical. The minimum flash point behaviour (MFPB) is exhibited when the flash point of a mixture is below the flash points of the individual components. The identification of this behaviour is critical, because a hazardous situation results from taking the lowest component flash point value as the mixture flash point. In this study, the flash points for the n-butanol + n-decane and n-octane + n-propanol systems which exhibit MFPB, were measured by Tag open-cup apparatus. The experimental data were compared with the alues calculated by the Raoult's law, the van Laar equation and the Wilson equation. The calculated values based on the van Laar and Wilson equations were found to be better than those based on the Raoult's law. It was concluded that the van Laar and Wilson equations were more effective than the Raoult' law at describing the activity coefficients for non-ideal solution such as the n-butanol + n-decane and n-octane + n-propanol systems. The predictive curve of the flash point prediction model based on the Wilson equation described the experimentally-derived data more effectively than was the case when the prediction model was based upon the van Laar equation.

Density Measurement of Liquid Mixture and Estimation of Excess Molar Volume by A Cubic Equation of State (액체혼합물의 밀도 측정과 3차 상태방정식에 의한 과잉 몰부피의 예측)

  • Kim, Jung-Min;Bae, Hyo-Kwang
    • Korean Chemical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.637-640
    • /
    • 2005
  • The density of polar-nonpolar liquid mixtures composed of methyl tert-butyl ether(MTBE) and 2,2,4-trimethylpentane, and methyl ethyl ketone (MEK) and 2,2,4-trimethylpentane, and the density of polar-polar liquid mixture of MTBE and MEK were measured by densitometer at 278.15 K, 288.15 K and 298.15 K, respectively. The excess molar volume of the binary systems calculated from the measured density was shown good agreement with the calculated one by the cubic Peng-Robinson- Stryjek-Vera (PRSV) equation of state together with Huron-Vidal mixing rule and it confirmed that the cubic PRSV equation of state could be used in the molar volume calculation of polar mixture.

A Study on Flash Points of Flammable Substances- 1. Pure Substances and A Mixture of Binary System - (가연성물질의 인화점에 관한 연구- 1. 순수성분 및 2성분계 혼합물-)

  • 하동명;목연수;최재욱
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 1999
  • The flash point is generally used as a hazardous index of fire and explosion of a flammable liquid. A classification of the flash points is important for the safe handling of flammable liquids such as solvent mixtures. The flash points of pure substances and solvent mixtures can be c calculated with the appropriate use of the fundamental laws of Raoult, Dalton, Le Chatelier and a activity coefficient models. In this study, experimentally determined lower and upper flash points w were compared with the calculated values by using Raoult's law and van Laar equation. The flash points of pure substances were in agreement with the calculated values by vapor pressure and e explosive limits. Also, the lower flash points of M.E.K(methylethylketone)-toluene system were i in agreement with the predicted values by Raoult’s law, and the upper flash points were in a agreement with the predicted values by van Laar equation. By means of this methodology, it is possible to evaluate reliability of expermental data of the flash points of the flammable mixtures.

  • PDF

Measurement and Prediction of Flash Points of Acetic Acid-Formic Acid System using Cleveland Open Cup Apparatus (Cleveland 개방식 장치를 이용한 Acetic acid+Formic acid 계의 인화점 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.67-72
    • /
    • 2013
  • The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. The flash point is a major physical property used to analyse the fire and explosion hazards of a flammable liquid solution. The flash point data for pure components are easily available in several literature. But the flash points of the flammable binary solutions appear to be scarce in the literature. The objective of this study is to measure and estimate the flash point of acetic acid-formic acid system. Cleveland open cup tester was used to measure the flash point. The experimental data were compared with the values estimated by the Raoult's law and the optimization methods based on van Laar and Wilson equations. As a result, the estmated values by optimization methods were found to be better than those based on the Raoult's law.

Measurement and Prediction of the Flash Point for the Flammable Binary Mixtures using Tag Open-Cup Apparatus (Tag식 개방계 장치를 이용한 가연성 이성분계 혼합물의 인화점 측정 및 예측)

  • Ha, Dong-Myeong;Lee, Sungjin;Song, Young-Ho
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.181-185
    • /
    • 2005
  • The flash point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of industrial material. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The flash points for the n-butanol+n-propionic acid and n-propanol+n-propionic acid systems were measured by using Tag open-cup apparatus(ASTM D 1310-86). The experimental data were compared with the values calculated by the laws of Raoult and van Laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

Estimation of the Flash Points for n-Propanol+Formic acid System Using the Binary Parameters Optimization Method (이성분계 파라미터 최적화 기법을 활용한 n-Propanol+Formic acid 계의 인화점 추산)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.65-69
    • /
    • 2008
  • An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the n-propanol+formic acid system were measured by Pensky-Martens closed cup apparatus. This binary mixture exhibited MFPB (minimum flash point behavior), which leads to the minimum on the flash point vs composition curve. The Raoult's law and optimization method using Wilson equation were used to predict the lower flash points and were compared with experimental data. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

The Measurement and Prediction of Maximum Flash Point Behavior for Binary Solution (이성분계 용액의 최대인화점 현상의 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.70-74
    • /
    • 2013
  • The flash point is one of the most important physical properties to charaterize fire and explosion hazard of liquid solutions. The maximum flash point of liquid mixture is larger than those of the individual components. In this study, the flash points of 2-pentanol+acetic acid system were measured by Seta flash closed cup tester. This system exhibited the maximum flash point behavior. The flash points were estimated by the Raoult's law and the optimization methods using the van Laar and Wilson equations. The calculated values by optimization methods were found to be better than those based on the Raoult's law.

Measurement of Lower Flash Point for Ternary Mixture, n-Nonane+n-Decane+n-Dodecane System (삼성분계 혼합물인 n-Nonane+n-Decane+n-Dodecane 계의 하부인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.31-36
    • /
    • 2016
  • The flash point is one of the most important indicators of the flammability of liquid solutions. The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. In this study the flash points of ternary liquid solutions, n-nonane+n-decane+n-dodecane system, were measured using Seta flash closed cup tester. The measured values were compared with the calculated values using Raoult's law and empirical equation. The calculated data by empirical equation described the measured values more effectively than those calculated by Raoult's law.