A Study on Flash Points of Flammable Substances- 1. Pure Substances and A Mixture of Binary System -

가연성물질의 인화점에 관한 연구- 1. 순수성분 및 2성분계 혼합물-

  • 하동명 (세명대학교 산업안전공학과) ;
  • 목연수 (부경대학교 안전공학과) ;
  • 최재욱 (부경대학교 안전공학과)
  • Published : 1999.03.01

Abstract

The flash point is generally used as a hazardous index of fire and explosion of a flammable liquid. A classification of the flash points is important for the safe handling of flammable liquids such as solvent mixtures. The flash points of pure substances and solvent mixtures can be c calculated with the appropriate use of the fundamental laws of Raoult, Dalton, Le Chatelier and a activity coefficient models. In this study, experimentally determined lower and upper flash points w were compared with the calculated values by using Raoult's law and van Laar equation. The flash points of pure substances were in agreement with the calculated values by vapor pressure and e explosive limits. Also, the lower flash points of M.E.K(methylethylketone)-toluene system were i in agreement with the predicted values by Raoult’s law, and the upper flash points were in a agreement with the predicted values by van Laar equation. By means of this methodology, it is possible to evaluate reliability of expermental data of the flash points of the flammable mixtures.

인화점은 일반적으로 가연성액체의 화재 및 폭발의 위험지수로써 사용된다. 인화점의 구분은 혼합용제와 같은 가연성액체를 안전하게 취급하기 위해서 매우 중요하다. 순수성분 및 혼합용제의 인화점은 라울의 법칙, 달톤의 법칙, 르 샤틀리에 법칙 그리고 활동도계수 모델을 사용함으로써 계산할 수 있다. 본 연구에서는 가연성 2성분계인 메칠에칠케톤과 톨루엔계의 하부인화점과 상부인화점의 실험자룔르 라울의 법칙과 van Laar식에 의해 계산된 값과 비교하였다. 순수물질의 실험자료는 증기압과 폭발한계에 의해 계산된 예측값과 일치하였다. 메칠에칠케톤과 톨루엔계의 하부인화점의 실험자료는 라울의 법칙에 의해 예측된 값과 일치하였고, 상부인화점의 실험자료는 van Laar식에 의해 예측된 값과 일치하였다. 따라서 제시한 방법론에 의해 가연성혼합용제의 인화점 실험자료의 신뢰도 평가가 가능하다.

Keywords