• Title/Summary/Keyword: 호흡치료

Search Result 1,279, Processing Time 0.034 seconds

Efficacy of a Respiratory Training System on the Regularity of Breathing (호흡연습장치를 적용한 호흡교정법의 영향 평가)

  • Shin, Eun-Hyuk;Park, Hee-Chul;Han, Young-YIh;Ju, Sang-Gyu;Shin, Jung-Suk;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.181-188
    • /
    • 2008
  • Purpose: In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. Materials and Methods: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. Results: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. Conclusion: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal regularity and maintaining a more even tidal volume.

Safety and Efficacy of the Mandibular Advancement Device 'Bioguard' for the Treatment of Obstructive Sleep Apnea : A Prospective, Multi-Center, Single Group, and Non-Inferiority Trial (폐쇄성 수면무호흡증의 치료에 사용되는 하악전방이동장치-'바이오가드'의 안전성과 유효성 검증을 위한 전향적, 다기관, 단일군 및 비열등성 연구)

  • Kim, Hyoung Wook;Hwang, Chungpoong;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Objectives: The purpose of this study was to estimate the safety and efficacy of a mandibular advancement device (MAD), 'Bioguard,' for the treatment of obstructive sleep apnea (OSA). Methods: In this 5-week prospective, multi-center, single group, and non-inferiority trial, patients who chose 'Bioguard' as their treatment option were evaluated using both questionnaires (Pittsburgh Sleep Quality Index (PSQI), Epworth sleepiness scale (ESS)) and polysomonography (PSG) (apnea hypopnea index (AHI), oxygen saturation). All patient data, including clinical records, PSG studies (both pre- and post-treatment), and adverse events (AEs), were reviewed and analyzed. Results: Results were obtained for 59 of 62 patients (95.16%). No significant difference in success rate was found between the MAD treatment and surgical treatment (95% CI). AHI, PSQI, ESS and oxygen saturation demonstrated significant improvement (p < 0.001) after MAD treatment, and 39 of 62 patients (62.9%) reported 85 AEs. 79 of the 85 AEs (91.8%) were mild cases, and there were no severe AEs related to the MAD treatment. Conclusion: The MAD 'Bioguard' should be considered as an alternative treatment option for OSA patients.

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

Microimplant mandibular advancement (MiMA) therapy for the treatment of snoring and obstructive sleep apnea (OSA) (코골이 및 수면 무호흡 치료를 위한 마이크로 임프란트를 이용한 하악골 전진술)

  • Ngiam, Joachim;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.40 no.2
    • /
    • pp.115-126
    • /
    • 2010
  • This case report describes the treatment of a 66 year old adult patient with a diagnosis of severe obstructive sleep apnea who was intolerant of nasal continuous positive airway pressure (nCPAP) treatment and oral appliance therapy. An alternative treatment of snoring and obstructive sleep apnea (OSA) with 2 orthodontic microimplants anchored to the mandible providing skeletal anchorage for mandibular advancement was implemented. After a 2 week healing period, a custom designed facemask provided extraoral anchorage to which the microimplants were connected to for titratable mandibular advancement. Microimplant Mandibular Advancement (MiMA) therapy resulted in resolution of the symptoms of severe OSA with a reduction of the apnea-hypopnea index (AHI), snoring and OSA symptoms.

High Frequency Ventilation (고빈도 환기법)

  • Lee, Hyeon-U;Lee, Gwan-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.1-17
    • /
    • 1993
  • 고빈도 환기법은 최근에 개발되어 임상에 응용되면서 호흡생리학, 마취학, 집중치료의 학등의 분야에서 호흡부전의 새로운 치료법으로 관심이 집중되고 있는 환기법이다. 현재까지 고빈도 환기법중 고빈도 양압 환기와 제트 환기는 비교적 많은 연구가 되고 있고 임상적으로 사용되고 있으나 고빈도 진동 환기법은 제한적으로 사용되고 있다. 앞으로 고빈도 진동 환기법에 대해서도 더 많은 연구가 되어야 할 것이다. 또한 최근 개발되고 있는 고빈도 흉벽 진동 환기와 체표면 진동 환기에도 관심을 기울이면 호흡부전 환자의 치료에 바람직한 새로운 환기법이 될 수 있을 것으로 기대된다. 현재 고빈도 환기법의 몇몇 적용형태는 기관지-늑막루등의 폐압손상으로 인한 병변의 치료외에도 기관수술, 흉부수술, 뇌수술에서 수술부위의 움직임을 최소화시키면서 충분한 가스교환율 이룩할 수 있어서 효과적으로 이용되고 있다. 그러나 응급심폐소생술, 폐쇄성 폐질환, 성인 또는 영아 호흡곤란증후군등과 같은 질환에서의 적용은 더 규명되어져야겠다. 고빈도 환기법의 여러가지 문제점중 적절한 환기빈도의 결정, 충분한 습도를 공급하는 장치, 고빈도 환기의 정확한 감시장치의 개발등은 앞으로 우선적으로 해결해야 할 문제점이다. 또한 임상에 더욱 효과적으로 응용될 수 있는 새로운 환기법이 되기 위해서는 고빈도 환기법의 호흡생리와 안정성등에 관한 연구도 병행되어야겠다.

  • PDF

4-Dimensional Imaging and Planning (4차원 영상 및 치료계획)

  • Jo, Byeong-Cheol;Park, Hui-Cheol;Kim, Su-San;O, Do-Hun;Bae, Hun-Sik
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.11-15
    • /
    • 2005
  • 입체조형 및 세기조절 방사선치료가 보편화되어 가고 있는 현 시점에서, 치료율을 높이기 위해 종양처방선량은 증가시키는 반면 부작용은 최소화하고자 하는 요구가 증가하고 있다. 셋업오차 및 체내운동(internal motion)은 이러한 요구를 충족시키는데 대한 한계로 작용하고 있다. 4차원방사선치료(4-dimensional radiation therapy)는 체내운동을 최소화시키거나 또는 움직임을 추적하여 방사선치료를 시행함으로써 “종양선량최대화/정상조직선량최소화”라는 고정밀방사선치료의 요구에 부응할 수 있는 치료기술로 기대를 모으고 있다. 체내운동은 호흡에 의한 움직임과 같이 단기적으로 발생되는 조사분할내(intra-fraction)와 종양의 수축, 체중 변화 등과 같이 장기적으로 발생하는 조사분할간(inter-fraction)움직임으로 구분되는데, 본 연제에서는 주로 조사분할내 움직임, 즉 호흡에 의한 움직임에 대처하는 4차원방사선치료를 위한 동적영상 획득 및 방사선치료계획과정에 초점을 맞추어 소개하고자 한다.

  • PDF

Current Status of Respiratory Care in Korean Intensive Care Units (국내 중환자실내 호흡치료의 현황)

  • Park, So-Yeon;Kim, Tae-Hyung;Kim, Eun-Kyung;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.343-352
    • /
    • 2000
  • Backgrounds : Respiratory care for patients in intensive care units (ICUs) has been performed mainly by nurses in Korea. However, the current status of respiratory care in the Korea ICUs is not well known. Respiratory care and the methods of delivery in ICUs were surveyed. Method : A confidential questionnaire was distributed to the head nurses working the ICUs at 117 hospitals in Korea. One hundred hospitals returned the questionnaires, for a response rate of 85%. The hospitals were divided into three groups : Main university hospitals (MUH), university associated hospitals (UAH), and general hospitals (GH) Result : Eighteen units of 66 units in MUH and 35 units of 58 units in GH were organized as a general ICUs. The percentage of ICUs with full-time doctors was 47.1%. The nurses usually delivered respiratory care spending from 1 to 4 h during their 8 h of working time. Although the respondents felt that respiratory care should be delivered by trained respiratory therapists, these therapists were not found at the hospitals. Most of the units performed percussion, tracheal suctioning, and positional changes. However, vibration and IPPB were less frequently performed in GH. Among oxygen supply apparatus, venturi mask and T-piece were not frequently used in GH. GH applied a noninvasive ventilator mode less frequently than MUH and UAH. The percentage of Swan-Ganz catheter monitoring was only 21.4% in GH. Conclusion : Respiratory care for patients in the Korean ICUs was provided by nurses on the whole. In addition, there were many differences in the level of respiratory care according to the type of hospital. To overcome the current problems revealed, an effective in-hospital training program for the development of full-time respiratory care therapists should be established urgently in Korea.

  • PDF

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization (자체 제작한 정위적체부방사선치료(Stereotactic Body Radiotherapy) 고정용구의 유용성 평가)

  • Lee, Dong-Hoon;Ahn, Jong-Ho;Seo, Jeong-Min;Shin, Eun-Hyeok;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Materials and Methods: Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. Results: The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. Conclusion: The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations. Particularly in case of the stereotactic body therapy which requires the maintenance of set-up state for a long time, the self-developed immobilizations is thought to more useful for stereotactic body radiotherapy rather than the rest two immobilizations with instable respiratory cycle as time passes.

  • PDF

COPD Patients with Hypercapnic Respiratory Failure : Response to Therapy and Determinant of Intubation (만성폐쇄성폐질환 환자의 고탄산혈증성 호흡부전 : 치료 반응 및 기도삽관의 결정인자)

  • Song, So-Hyang;Kim, Chi-Hong;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.462-472
    • /
    • 2001
  • Background : The determinants of intubation and the response to therapy in COPD patients with hypercapnic respiratory failure were retrospectively reviewed. Methods : This study involved a review of 132 episodes of hypercapnic respiratory failure($PaCO_2\;{\geq}\;50\;mmHg$ and $pH\;{\leq}\;7.35$). The time frame for resolution or the time to intubation of patients who were admitted between 1996 and 1999 was analyzed. Results : Out of 132 hypercapnic episodes, 49(37%) required intubation. A comparison was made with the 83 cases that responded to treatment. Patients requiring intubation had a greater severity of illness, which included a higher APACHE II (Acute Physiology and Chronic Health Evaluation II) score ($20{\pm}5$ vs $14{\pm}4$ ; p<0.01), a higher WBC, a higher serum BUN, and greater acidosis (pH, $7.23{\pm}0.11$ vs $7.32{\pm}0.04$ ; p<0.01). Those with the most severe acidosis(pH<7.20) had the highest intubation rate(87%) and shortest time to intubation($2{\pm}3\;h$). Conversely, those with an initial pH 7.31 to 7.35 were less likely to be intubated(20%), and had a longer time to intubation($97{\pm}121\;h$). The patients with a pH 7.21 to 7.25($4.1{\pm}2.9$ day) required longer period of time to respond to medical treatment than patients with a pH of 7.31 to 7.35($2.2{\pm}3.1$ day). Of those patients requiring intubation, half(55%) were intubated within 8 h of admission, and most (75%) within 24 h. Of those patients responding to treatment medical therapy, half(52%) recovered within 24 h and most (78%) recovered within 48 h. Conclusion: Respiratory acidosis at the initial presentation is associated with an increased likelihood of intubation. This should assist in deciding help with the decision whether to treat patients medically, institute noninvasive ventilation, or proceed to intubation.

  • PDF