• Title/Summary/Keyword: 호흡수

Search Result 2,131, Processing Time 0.027 seconds

Changes of Moisture Uptake. Respiration and Chemical Contents in Germinating Tobacco(Nicotiana tabacum L.) Seeds (담배종자의 발아조건에서 수분흡수, 호흡 및 저장물질의 변화)

  • 민태기;윤경은;김웅주;강정용
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.31 no.3
    • /
    • pp.293-298
    • /
    • 1986
  • The physiological aspects of tobacco seeds from seeding to germination under light and dark condition, and different temperature were studied to obtain basic information on the production of good seedlings. There were distinct three phases in moisture uptake and respiration process during germination that classifiable into 'Imbibition', 'Lag', and 'Growth' phase under light condition but such growth phase were not observed in the dark germination. Great changes of sugar and fatty acid content of tobacco seeds were observed during germination in light condition but such changes were slight in dark germinated seeds and fatty acid content of seeds during germination were decreased as corresponding to increasing in respiration.

  • PDF

A Successful Decannulation Case Two Years Later A Tracheostomy (2년후에 발거가 가능했던 기관 cannula 발거곤란병)

  • 이종원;김종영;김성곤;권령춘;양한모
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.87.3-87
    • /
    • 1976
  • The authors experienced a case of a difficult decannulation in a 4 years old boy, in which. case decannulation was possible 2 years later a tracheostomy. Some immunoglogical phenomena could be considered in this case as though cancer can remiss spontaneously. Such complications of tracheostomy as subglottic edema and perichondritis could become relatively less troublesome to breathing during his aging process. And another reason for the easy decannulation is considered as the patient could be accustomed to breathing through natural air pathway by continual cannula corking training.

  • PDF

Respiratory Assist by Use of Electrical Diaphragmatic Pacing (전기자극에 의한 횡격막 조율을 이용한 호흡보조장치)

  • 오중환;김은기;서재정;박일환;김부연;이상헌;이종국;이영희
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.441-446
    • /
    • 2001
  • Background: Electrical breathing pacing has many advantages over mechanical ventilation. However, clinically permanent diaphragmatic pacing has been applied to limited patients and few temporary pacing has been reported. Our purpose is to investigate the feasibility of temporary electrical diaphragm pacing in explothoracotomy canine cases. Methods: Five dogs were studied under the general anesthesia. Left 5th intercostal space was opened. Self designed temporary pacing leads were placed around the left phrenic nerve and connected to the myostimulator. Chest wall was closed after tube insertion with underwater drainage. Millar catheter was introduced to the aorta and right atrium. Swan-Ganz catheter was introduced to the pulmonary artery. When the self respiration was shallow with deep anesthesia, hemodynamic and tidal volume were measured with the stimulator on. Results: Tidal volume increased from 143.3$\pm$51.3 ml to 272.3$\pm$87.4 ml(p=0.004). Right atrial diastolic pressure decreased from 0.7$\pm$4.0 mmHg to -10.5$\pm$4.7 mmHg(p=0.005). Pulmonary arterial diastolic pressure decreased from 6.1+2.5 mmHg to 1.2$\pm$4.8 mmHg(p<0.001). The height of water level in chest tube to show intrathoracic pressure change was from 10.3$\pm$6.7cmH$_{2}$O to 20.0$\pm$5.3 cmH$_{2}$O. Conclusion: Temporary electrical diaphragmatic pacing is a simple method to assist respiration in explothoracotomy canine cases. Self designed pacing lead is implantable and removable. Negative pressure ventilation has favorable effects on the circulatory system. Therefore, clinical application of temporary breathing pacing is feasible in thoracotomy patients to assist cardiorespiratory function.

  • PDF

A Smart Bed for Managing Sleep (수면관리를 위한 스마트 침대)

  • Park, San-Hee;Kim, Dong-Jin;Jang, Jun-Beom;Jo, Da-Hoon;Choi, Seong-Hun
    • Annual Conference of KIPS
    • /
    • 2020.11a
    • /
    • pp.232-235
    • /
    • 2020
  • 본 논문은 코골이 및 폐쇄성 무호흡 환자들의 수면의 질 향상을 위한 자세 교정 및 건강관리를 제공하는 스마트 침대를 제안한다. 기존 코골이 및 폐쇄성 무호흡 환자들을 위한 베개 및 자세변환 시스템은 코골이를 방지해 주거나, 혹은 폐쇄성 무호흡 환자들을 위한 용도로만 존재해왔다. 이에 본 논문에서는 사용자의 코골이, 폐쇄성 무호흡뿐만 아니라 개별적으로 존재하는 질병을 침대에서 사용자의 수면 상태 정보, 산소포화도, 뒤척임 정보를 수집하여 개인별 차별화된 자세를 추천 및 교정해준다. 또한 전용 애플리케이션의 건강 신호등 시스템으로 사용자에게 자신의 건강을 직관적으로 확인 시켜 줄 수 있다. 이를 통해 본 논문은 코골이로 인한 소음, 무호흡증을 완화하고 숙면을 돕는 서비스 개발을 목적으로 한다.

An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration (예측 불가능한 호흡 변화에 따른 사이버나이프 종양 추적 방사선 치료의 정확도 분석)

  • Seo, jung min;Lee, chang yeol;Huh, hyun do;Kim, wan sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • Purpose : Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. Results : If the target error is a sine curve breathing form, the size of the target of the movement is in response to the 5 mm, 10 mm, 20 mm, respectively, of the average $1.14{\pm}0.13mm$, $1.05{\pm}0.20mm$, with $2.37{\pm}0.17mm$, suddenly for it is variations in breathing, respective average $1.87{\pm}0.19mm$, $2.15{\pm}0.21mm$, and analyzed with $2.44{\pm}0.26mm$. If the correlation error can be defined by the length of the displacement vector in the target track is a sinusoidal breathing mode, the size of the target of the movement in response to 5 mm, 10 mm, 20 mm, respective average $0.84{\pm}0.01mm$, $0.70{\pm}0.13mm$, with $1.63{\pm}0.10mm$, if it is a variant of sudden breathing respective average $0.97{\pm}0.06mm$, $1.44{\pm}0.11mm$, and analyzed with $1.98{\pm}0.10mm$. The larger the correlation error values in both the both the respiratory form, the target error value is large. If the motion size of the target of the sine curve breathing form is greater than or equal to 20 mm, was measured at 1.5 mm or more is a recommendation value of both cyber knife manufacturer of both error value. Conclusion : There is a tendency that the correlation error value between about target error value magnitude of the target motion is large is increased, the error value becomes large in variation of rapid respiration than breathing the form of a sine curve. The more the shape of the breathing large movements regular shape of sine curves target accuracy of the tumor tracking system can be judged to be reduced. Using the algorithm of Cyber-Knife tumor tracking system, when there is a change in the sudden unpredictable respiratory due patient coughing during treatment enforcement is to stop the treatment, it is assumed to carry out the internal target validation process again, it is necessary to readjust the form of respiration. Patients under treatment is determined to be able to improve the treatment of accuracy to induce the observed form of regular breathing and put like to see the goggles monitor capable of the respiratory form of the person.

  • PDF

Implement the system of the Position Change for Obstructive sleep apnea patient (폐쇄성수면 무호흡 환자의 자세변환 시스템 구현)

  • Ye, Soo-young;Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1231-1236
    • /
    • 2017
  • In this study, we developed a system that can change position to improve obstructive sleep apnea. Blocking of the breathing airway caused by obstruction of the apnea, lateral position is provided by the airway to improve the apnea. We used a pressure sensor (FSR402) in the form of an array to determine the position of patient. The air cylinder was controlled to raise and lower the bed. As a result of calculating the pressure difference between the supine position and the lateral position, it was $0.41{\pm}0.30$ and $1.09{\pm}0.73$. In other words, when the patient is lateral position, the difference between the sensor values on the right and left side is large. Therefore, it is confirmed that the system can maintain airway to breath for improvement of obstructive sleep.

A Case of Childhood Obstructive Sleep Apnea Syndrome (소아 폐쇄성 수면무호흡증후군 1례)

  • Shin, Hong-Beom;Lee, Yu-Jin;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.2
    • /
    • pp.106-109
    • /
    • 2004
  • Adenotonsillar hypertrophy is the leading cause of childhood obstructive sleep apnea. Obstructive sleep apnea syndrome in childhood, however, can occur from various causes such as obesity or craniofacial abnormalities. Childhood obstructive sleep apnea syndrome can be accompanied by enuresis, parasomnias and behavior problems. For patients with the symptoms of snoring and apnea, obstructive sleep apnea should be suspected and diagnosed properly. In addition, the evaluation of complications and proper treatment are indispensable. When the cause of childhood obstructive sleep apnea is adenotonsillar hypertrophy, symptoms can be improved by surgical methods. If the cause is other than adenotonsillar hypertrophy, such as obesity, it should be treated with other therapeutic modalities, like nasal continuous positive airway pressure (nCPAP), weight reduction and modification of life style. This paper reports a case of nCPAP used to manage severe sleep apnea when it was not resolved after adenoidectomy and tonsillectomy. Differential diagnosis of narcolepsy in a case with excessive daytime sleepiness and reflections on accompanying enuresis and parasomnia were also described.

  • PDF

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

Blood Electrolytes and Metabolites in Rat Model of Acute Metabolic and Respiratory Alkalosis (흰쥐 급성 대사성 알칼리증과 호흡성 알칼리증 모델에서 혈액 전해질 및 대사산물)

  • Kim, Shang-Jin;Lee, Mun-Young;Kim, Jin-Shang;Kang, Hyung-Sub
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.257-261
    • /
    • 2010
  • The development of blood ionic changes could be precipitated in acid-base disorder and subsequent treatment. As technology for detecting circulating ionized $Mg^{2+}$ (the most interesting form with respect to physiological and biological properties) is now available in veterinary clinical medicine. This present study investigated the changes of whole blood ionized $Mg^{2+}$ correlated with acute metabolic and respiratory alkalosis in rodent model. Metabolic alkalosis was induced by intravenous infusion with $NaHCO_3$ and mechanical hyperventilation was applied for respiratory alkalosis. We founded that the blood ionized $Mg^{2+}$ could be reversibly decreased by the $NaHCO_3$-induced acute metabolic alkalosis but irreversibly increased by the mechanical hyperventilation-induced respiratory acidosis and respiratory acidosis. We suggested that the potential change in blood suggested that the potential change in blood ionized $Mg^{2+}$ should be counted in treatment of acid-base disorders.

Case of Treatment Using Adaptive Servo-Ventilation in a Patient with Central Sleep Apnea after a Lateral Medullary Infarction (외측 연수 경색에 의해 발생한 중추성 수면 무호흡 환자의 자동-적응형 양압기를 사용하여 치료한 경험)

  • Kim, Dae Jin;Cho, Jae Wook;Kim, Hyun Woo;Choi, Jeong Su;Mun, Sue Jean
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.278-283
    • /
    • 2020
  • Central sleep apnea (CSA) is characterized by respiratory failure of at least 10 seconds without any effort of the chest and abdomen in the absence of upper airway resistance during sleep. In this case, the patient experiences respiratory failure that does not meet the CSA diagnostic criteria and CSA symptoms. Magnetic resonance imaging diffusion-weighted imaging (MRI DWI) scans revealed a lateral medullary infarction. Continuous positive airway pressure (CPAP) was applied as a primary treatment for CSA and respiratory failure. During the titration of CPAP, the apnea-hypopnea index (AHI) and arousal index (AI) were worse than the results before its use (AHI: 42.5/hr→82.8/hr, AI: 21.7/hr→40.8h). As a result, adaptive servo-ventilation (ASV) was chosen as the secondary treatment. Compared to the night-polysomnography results before the ASV treatment, the AHI improved (42.5/hr→8.6/hr). Therefore, ASV is a potential treatment for CSA and respiratory failure in these patients.