• Title/Summary/Keyword: 호흡수

Search Result 2,131, Processing Time 0.022 seconds

A Study on the Usefulness of Subjective Lumbar Instability Factor for Respiratory Pattern Change and Abdominal Mobility in Peoples with CLBP (만성허리통증자의 호흡 패턴과 배부 운동성 변화에 대한 주관적 허리부위 불안정성 요소의 유용성에 관한 연구)

  • Ki, Chul;Lee, Kwan-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.206-214
    • /
    • 2020
  • This study examined the correlation between the respiratory pattern change (RPC) and abdominal mobility (AM) according to the positive result of the subjective lumbar instability factor (SLIF) in people with chronic low back pain (CLBP). Thirty-six adults with CLBP participated in this study. Twenty-eight items of the SLIFs were examined, and the subjects were divided into three groups according to the positive response numbers (PRN). After the change lists were scored, three RPC scores [costo-diaphragmatic RPC (CDRPC), breath hold change (BHC), and total RPC (TRPC)] were obtained. The abdominal mobility (AM) was measured between the maximal inspiration and exhalation at the xiphoid (AM1) and the 10th rib (AM2) level of the trunk. The results showed that the RPC score and AM were compared according to the positive response number of SLIF, and the relationship between them was analyzed. A positive correlation was observed between the SLIF positive response number and CDRPC score, BHC score, and total RPC score, and a negative correlation was observed between the SLIFs positive response number and AM1 and AM2. Based on the results of this study, the combination of SLIF positive responses can be a predictor of non-physiological respiratory pattern changes in people with CLBP. Clinically, this prediction is expected to help save time for screening and improve the efficiency of therapy.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

Sleep Architecture and Physiological Characteristics of Obstructive Sleep Apnea in Split-Night Analysis (수면분할 분석으로 본 수면무호흡증의 수면구조와 생리적 특징)

  • Kim, Eui-Joong
    • Sleep Medicine and Psychophysiology
    • /
    • v.13 no.2
    • /
    • pp.45-51
    • /
    • 2006
  • Obstructive sleep apnea (OSA) syndrome disrupts normal sleep. However, there were few studies to evaluate the asymmetric distribution, the one of the important factors of normal sleep in OSA subjects. We hypothesized that asymmetry would be broken in OSA patients. 49 male subjects with the complaint of heavy snoring were studied with polysomnography. We divided them into two groups based on the apnea-hypopnea index (AHI) fifteen: 13 simple snoring group (SSN, average AHI $5.9{\pm}4.4$) and 32 OSA group (average AHI $47.3{\pm}23.9$). We compared split sleep variables between the first half and the second half of sleep within each group with paired t-test for the evaluation of asymmetry. Changes of sleep architecture of OSA were higher stage 1 sleep% (S1), total arousal index (TAI), AHI, and mean heart rate (HR) and lower stage 2 sleep% (S2), REM sleep%, and mean arterial O2 saturation (SaO2) than SSN subjects. SWS and wake time after sleep onset (WASO) were not different between two groups. In split-night analysis, OSA subjects showed higher S2, slow wave sleep% (SWS), spontaneous arousal index (SAI), and mean HR in the first half, and higher REM sleep% and mean SaO2 in the second half. Those were same pattern as in SSN subjects. Mean apnea duration and longest apnea duration were higher in the second half only in the OSA. No differences of AHI, ODI, WASO, and S1 were found between the first and the second half of sleep in both groups. TAI was higher in the first half only in the SSN. SWS and WASO seemed to be influenced sensitively by simple snoring as well as OSA. Unlike our hypothesis, asymmetric distributions of major sleep architecture variables were preserved in OSA group. Losing asymmetry of TAI might be related to pathophysiology of OSA. We need more studies that include large number of subjects in the future.

  • PDF

The Concept and Clinical Application of the Respiratory Sinus Arrhythmia Biofeedback (호흡 동성 부정맥 (Respiratory Sinus Arrhythmia) 바이오피드백의 개념과 임상적 활용)

  • Lee, Chang-Soo;Woo, Jong-Min
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.14 no.1
    • /
    • pp.33-38
    • /
    • 2006
  • Biofeedback training to increase the amplitude of respiratory sinus arrhythmia(RSA) maximally increases the amplitude of heart rate variability(HRV) only in respiratory rate at approximately 0.1Hz. To perform this task, people slow their breathing to this rate to point where resonance occur between respiratory sinus arrhythmia(RSA) and oscillation that naturally occur at this rate, probably triggered in part by baroreflex activity. The biofeedback technique allows each individual to breathe at a rate that is specifically adapted to the rhythms of his or her own body. A manual is presented for carrying out this method.

  • PDF

Respiratory signal analysis of liver cancer patients with respiratory-gated radiation therapy (간암 호흡동조 방사선치료 환자의 호흡신호분석)

  • Kang, dong im;Jung, sang hoon;Kim, chul jong;Park, hee chul;Choi, byung ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Purpose : External markers respiratory movement measuring device (RPM; Real-time Position Management, Varian Medical System, USA) Liver Cancer Radiation Therapy Respiratory gated with respiratory signal with irradiation time and the actual research by analyzing the respiratory phase with the breathing motion measurement device respiratory tuning evaluate the accuracy of radiation therapy Materials and Methods : May-September 2014 Novalis Tx. (Varian Medical System, USA) and liver cancer radiotherapy using respiratory gated RPM (Duty Cycle 20%, Gating window 40% ~ 60%) of 16 patients who underwent total when recording the analyzed respiratory movement. After the breathing motion of the external markers recorded on the RPM was reconstructed by breathing through the acts phase analysis, for Beam-on Time and Duty Cycle recorded by using the reconstructed phase breathing breathing with RPM gated the prediction accuracy of the radiation treatment analysis and analyzed the correlation between prediction accuracy and Duty Cycle in accordance with the reproducibility of the respiratory movement. Results : Treatment of 16 patients with respiratory cycle during the actual treatment plan was analyzed with an average difference -0.03 seconds (range -0.50 seconds to 0.09 seconds) could not be confirmed statistically significant difference between the two breathing (p = 0.472). The average respiratory period when treatment is 4.02 sec (${\pm}0.71sec$), the average value of the respiratory cycle of the treatment was characterized by a standard deviation 7.43% (range 2.57 to 19.20%). Duty Cycle is that the actual average 16.05% (range 13.78 to 17.41%), average 56.05 got through the acts of the show and then analyzed% (range 39.23 to 75.10%) is planned in respiratory research phase (40% to 60%) in was confirmed. The investigation on the correlation between the ratio Duty Cycle and planned respiratory phase and the standard deviation of the respiratory cycle was analyzed in each -0.156 (p = 0.282) and -0.385 (p = 0.070). Conclusion : This study is to analyze the acts after the breathing motion of the external markers recorded during the actual treatment was confirmed in a reproducible ratios of actual treatment of breathing motion during treatment, and Duty Cycle, planned respiratory gated window. Minimizing an error of the treatment plan using 4DCT and enhance the respiratory training and respiratory signal monitoring for effective treatment it is determined to be necessary.

  • PDF

Statistical Study on Respiratory Signal Analysis according to Patient Position and Device in Radiation Therapy (방사선치료 시 자세와 device에 따른 호흡신호의 분석)

  • Seo, Jeong-Min;Park, Myung-Hwan;Shim, Jae-Koo;Kim, Chan-Hyeong;Park, Cheol-Soo;Kim, Kyung-Keun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.179-187
    • /
    • 2011
  • This study statistically analyzed the difference of the stability of maintaining a respiratory period shown according to position and use of a device to search the tendency and usefulness of a device. The supine position showed better maintaining respiratory cycles than the prone position. The 85% of subjects who showed bad maintenance pattern of a respiratory cycle were significantly different pattern with using belly board. It could be said that there was a significant correlation between the maintenance of a respiratory cycle and relative index of respirational stability(p=0.044, kappa=0.607). The movement due to respiration was one of important considerations in the radiation therapy on chest, abdomen, and even pelvis. This study could contribute to the high quality radiation therapy by statistic analysis of respiratory signals and its application.

The Effects of Self-Efficacy Promoting Pulmonary Rehabilitation Program in Out-Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 외래환자에서 자기효능감증진 호흡재활프로그램의 효과)

  • Jung, Jang Hee;Kim, Jung Youp
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.533-546
    • /
    • 2006
  • Background: The aim of this study was to determine the effectiveness of self-efficacy promoting pulmonary rehabilitation in patients with chronic obstructive pulmonary disease (COPD). Methods: thirty six patients, with clinically stable COPD were randomly assigned: 18 to a rehabilitation group and another 18 as a control group, The subjects participated in a the self-efficacy promoting pulmonary rehabilitation program for 8 weeks. This program consisted of education, breathing retraining, exercise training, relaxation and counseling. The control group received education only. The outcome variables were self-efficacy, dyspnea, exercise endurance, pulmonary function, and quality of life. Dyspnea was measured using the modified Borg scale. Exercise endurance was measured by the six minute walking distance. The quality of life was measured by the quality of life index for pulmonary disease patients. Results: In the rehabilitation group after performing the self-efficacy promoting pulmonary rehabilitation program, the self-efficacy score, exercise endurance, and quality of life score were higher than the control group (p=0.007, p=0.038, and p=0.039, respectively). and the exertional dyspnea score was significantly lower than controls(p=0.045). However, the dyspnea score and FEV1 were similar after performing the self-efficacy promoting pulmonary rehabilitation program. Conclusion: The self-efficacy promoting pulmonary rehabilitation program is effective to in improve self-efficacy, exertional dyspnea, exercise endurance and quality of life in patients with COPD.

Changes in Thoracoabdominal Usage Rate after Respiratory Pattern Correction in Patients with Lumbar Instability (호흡패턴교정이 요추불안정성자의 흉·복부 사용률에 미치는 효과)

  • Ki, Chul;Heo, Myoung
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.581-587
    • /
    • 2020
  • The Many patients who have lumbar instability(LI) could make a different trunk movement pattern by reduction of their respiratory function and altered breathing pattern. This study was conducted to investigate the change in the thoracoabdominal usage rate(TAUR) on three circumference lines(axillary, xiphoid junction, 10th rib) during the resting and forced breathing (RB and FB) after respiratory pattern correction(RPC) exercises in patients with LI. 15 patients in the experimental group performed RPC exercises, and 15 patients in the control group conducted lumbar stabilization exercises. Before the intervention, both groups had a significant difference in the usage rate among the three thoracoabdominal lines during the RB and FB(p<.05). After the intervention, the experimental group was seen no significant difference in the usage rate among the three lines during the RB(p>.05) and exhibited significant differences in the usage rate between the two thoracoabdominal lines during the FB(p<.05). The RPC exercises might improve the trunk movement patterns by restoring the respiratory patterns. We suggest that the RPC can apply in the re-education and reinforcement process at the reha-program for LI patients.

Analysis of Soil CO2 efflux across three age classes of plantation Pinus koraiensis (임령이 다른 잣나무림에서의 토양 호흡 분석)

  • Nam, Ki-Jung
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.116-123
    • /
    • 2018
  • The objective of this study was to examine effects of stand age on soil $CO_2$ efflux in plantation Pinus koraiensis, and to elucidate what extent plant (fine) root and soil microbial biomass contribute to the whole soil $CO_2$ efflux. In three age classes (20-yr-old. 40-yr-old, 70-yr-old) of plantation Pinus koraiensis, in-situ soil respiration, plant fine root biomass and soil microbial biomass were measured from April to November in 2004. Regardless of stand age, soil temperature and soil $CO_2$ efflux increased until July then slowly decreased. Soil respiration was higher in 70-yr-old stand than in 20- and 40-yr stands. Fine root biomass and soil microbial biomass was also higher in 70-yr-old stand. Root exclusion decreased soil respiration in 40-yr stand, but not in 70-yr stand. Soil microbial biomass was higher in 70-yr stand, but there was no monthly variation between July and November. The results suggest that soil respiration may increase as plant stand ages and microbial contribution could play more roles in older stands.

A Design Sensibility and Music Matching System by HRV and APG (HRV와 APG에 따른 감성과 음악 매칭 시스템 설계)

  • Kim, Tae-Yeun;Seo, Dae-Woong;Song, Byoung-Ho;Bae, Sang-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.894-897
    • /
    • 2008
  • The stress is an unavoidable result and a complex phenomenon in modem society. too, Human activity changes under control of the stress. The stress is a reaction to adrenalin or other stress hormones. It provides the power for fighting and the energy for going away from dangers. Because of the stress, our bodies increase the pulse, the blood pressure and the breath for more blood and more oxygen. So, in this research, we are measuring those which was increased by the stress. Also we will examine the change of HRV and APG on music. After that, in order to reduce the stress, we will design matching system that is based on the sense for music by using Zigbee.

  • PDF