• Title/Summary/Keyword: 호선

Search Result 426, Processing Time 0.03 seconds

An Analysis on Efficiency and Influencing Factors of the Quasi-Public Bus Operating System in Busan Metropolitan City Using DEA (DEA를 활용한 부산광역시 준공영제 시내버스 운용 효율성 평가 연구)

  • Seong, Woo-Yong;Kang, Jae-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.2
    • /
    • pp.349-367
    • /
    • 2019
  • This paper empirically analyzed the factors of operational efficiency after the quasi-public bus operating system in Busan Metropolitan City. DEA analysis result, for CRS the annual efficiency in 2010 of bus routes that can be transferred to subway lines 1 was the highest. The annual efficiency of bus routes that can be transferred to subway lines 2 shows the largest annual average of 0.923 in 2016 under the CRS average gradually improved over the year. Annual efficiency of subway lines No. 3 and transferable bus routes gradually improved from 2009 to 2015, but declined again in 2016. Among 536 routes for four years on 134 routes per year, 205 routes were found to be inefficient. In order to increase efficiency of the 205 routes, it is suggested that the number of routes should be reduced. In addition, the analysis results on DEA using the Tobit calibration, the most significant factors affecting the operational efficiency index were the time taken, followed by the number of passengers and the number of passengers transferred.

Evaluation of Environmental Contribution to the Effect of Reducing Carbon Dioxide Emission in Metropolitan Urban Railways (수도권 도시철도의 이산화탄소 배출량 절감 효과에 대한 환경 기여도 분석)

  • Joo, Jaemoom;Hong, Kiman;Hong, Youngsuk;Kim, Teagyun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.589-599
    • /
    • 2022
  • Purpose: The purpose of this study is to quantitatively identify the environmental contribution generated by urban rail users in the metropolitan area. Method: As for the analysis method, the mode choice and assignment of the traffic demand analysis were repeatedly performed on the assumption that each line was not opened for the metropolitan urban railway lines 1 to 9. After that, the environmental contribution according to changes in demand for the road was analyzed. Result: The total amount of carbon dioxide emissions and benefits were found to be the largest for subway line 1. However, when considering the number of stations and length, it was analyzed that the environmental contribution was the greatest in Metro Line 4. Conclusion: Measures to promote the use of public transportation are representative of environmental improvement policies, but there is a limit in that it is difficult for actual users/non-users to feel it. Therefore, it is judged that it is necessary to quantitatively present the effect in order to improve and spread awareness of the environment.

Roadkill of Amphibians in the Korea National Park (국립공원의 양서류 로드킬 현황)

  • Song, Jae-Young;Kim, Min-Sun;Kim, In-Su;Kim, Tae-Heon;Roh, Il;Seo, Sang-Won;Seo, Eun-Kyoung;Seo, Jung-Keun;Yang, Ju-Young;Woo, Kyung-Duk;Won, Hyeok-Jae;Lee, Young-Gu;Lim, Yun-Hee;Han, Sun-Han;Moon, Myeong-Geon
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.2
    • /
    • pp.187-193
    • /
    • 2009
  • To investigate the roadkill of amphibians in Korea National parks, we conducted a survey from 2006 to 2008. As a result, our count of road-killed amphibians included 1,748 individuals from 9 species over three years, and the ratio of road-killed amphibians decreased in 2007, 2008 as compared to 2006. Additionally, many amphibians, including Rana dybawskii, Bufo gargarizans, and Bufo stejnegeri were road-killed by vehicles in "Forest-Stream" or "Forest-Forest" environments, and between March and June. In the risk analysis by frequency, 4 lines including national line 37 (Deogyusan), provincial line 517 (Songnisan), national line 6 (Odaesan) and provincial line 597 (Woraksan) were classed as RISK V category. This designation involves species considered to be extremely important, such as Rana dybowskii and Bufo stejnegeri. Therefore, a conservation plan is needed to protect important species located near RISK V lines.

A study on efficient management of the drainages of underground tunnels for environmentally friendly urban railway systems (도시철도 친환경 지하터널 배수형식의 효율적인 유지관리 방안 검토)

  • Baek, Jong-Myeong;Hong, Jong-Hun;Kim, Han-Bae
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1982-1990
    • /
    • 2010
  • Excepting tunnel of dorimstream - ccachimountain station section, the subway line No.2th section was build using ASSM and NATM methods because of soil pressure and land condition. The way of dealing underground water was selected without sufficient preconsideration of geographical features, ground condition, influence of lowing underground water, and long-term cost of running maintenance so that the form of undrained tunnel was build having decreased construction characteristics and technically improper elements. The form of partial drainage is very difficult to manage structures of tunnel, because water leakage, water pressure causing cracks of lining concretes and scaling are constantly happened. so partial drainage suggest that setting reinforced Anchor Bolt to prevent buoyancy and should increase center drainage way up to height of railroad. Partial drainage suggest that holey pipe(${\phi}$350mm) manhole, drainage checking pipe manhole are should be regularly dredged, when changing roadbed(gravel${\rightarrow}$concrete) drainage checking pipe manhole should be build and setting a limitation of entering underground water's quantities. Beside drainage degree in changed section of structures causing instability of structures is continuous degree. so if efficient drainage way and the patterns of flaws, problems are considered in survey, it will be expected to have a advantage condition in maintenance part.

  • PDF

The relationship between the residual of Taean Mado shipwreck No.3 and physical properties of sediments (태안 마도3호선 잔존과 퇴적물 물성의 연계성)

  • Lee, Sang-Hee;Jung, Yong-Hwa;Lee, Young-Hyun;Kim, Jin-Hoo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.269-275
    • /
    • 2017
  • Shipwreck remains below the seabed not only effect the ocean currents and tides, but influence the physical properties of sediments and sedimentary environments that comprise the seabed. In particular, the influence of local shipwrecks discovered buried in the seabed on the sediment is visible. In this study, sediments were collected from the surrounding area of Taean Mado No.3 shipwreck using grab samplers and vibro-corers. The physical properties of these sediments were analyzed to evaluate the impact of the Taean Mado shipwreck No.3 remains. Sediment core analysis by means of density and ultrasonic velocity showed that shear strength tended to increase with depth, whereas moisture content and porosity tended to decrease with depth. Grain size analysis results are shown in terms of Folk's classification, where the grain size of the core samples in the study area indicate mud or sandy mud, and that of the grab sample indicates a muddy sand. Results of the sedimentation rate analysis indicate a rate of 2.84 cm/year and carbon dating of the 150 cm deep seashell indicates the Neolithic age. These sediments were analyzed for the study of the relationship between the Taean Mado shipwreck No.3 remains and the physical properties of the sediment.

Cause and Countermeasure of Inundation Damage in Underground Space (우리나라 지하공간 내수침수피해 원인 및 대책)

  • Cho, Jae-Woong;Choi, Woo-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.420-420
    • /
    • 2011
  • 도시지역의 내수침수피해는 거의 매년 발생하고 있으며, 반지하와 같은 거주공간이 매우 취약한 상태이다. 특히 최근에는 지하철, 지하상가 등이 대규모 개발되고 복합네트워크화 되어 지하공간의 침수대책과 대피방안 마련이 시급한 상황이다. 일본의 경우 2000년 토카이 호우피해 후 통합유출해석 모형을 개발하였으며, 1999년 및 2003년 후쿠오카 침수피해 발생 후 특정도시하천침수피해대책법을 제정, 1999 후쿠오카, 2004년 하마마츠, 2008년 카누마 피해 후 일본 방재연구소에서는 실시간 1차원 지표범람모형과 모니터링을 통한 실시간 내수침수지도를 개발하였다. 특히 지하공간에 대해서는 "지하공간에 유입하는 범람수가 계단상 보행자게에 주는 위험성에 관한 연구" 등 실험을 바탕으로 각종 지하공간 침수대책 매뉴얼 및 지하시설의 침수시 피난확보계획 지침, 지하공간 침수대책 가이드라인 등 인명피해를 줄이고자하는 노력이 계속되어 오고 있다. 우리나라는 2006년 경기도 고양시 3호선 정발산역이 침수되었으며, 2010년 서울시 지하철 2호선 사당역 및 4호선이 침수되는 등의 지하철 침수피해와 2010년 서울시 광화문 지하상가, 인천시 부평구 우림라이온스 벨리, 우남플라자, 계양구 농협하나로마트, 서원아파트 등의 지하상가와 지하다층의 침수피해가 발생하였다. 특히 2006년 3호선 정발산역 침수는 17시간이나 지하철이 불통되었고 이로 인하여 심각한 교통 체증이 유발 되었다. 본 연구에서는 2010년 집중호우로 인한 서울, 인천지역의 지하공간 침수피해를 중심으로 최근 10년간 지하공간 침수피해사례로부터 대표적인 침수피해 원인 및 특성을 정리하였으며, 그 결과 지하공간 침수의 주요원인은 지상공간의 침수류가 지하공간으로 유입하고, 지하공간의 배수설비 용량부족, 지하공간으로의 유입을 방지하기위한 방지턱, 차수판, 침수시 비상전원 공급, 침수시 지하공간 대피 매뉴얼의 부재 등 다양한 원인이 있는 것으로 나타났다. 특히, 소방방재청에서 고시한 '지하공간 침수방지를 위한 수방기준'에 지하공간 침수 방지를 위한 각종 시설의 설치 및 대피 경로지정 등에 대한 기준이 마련되어 있으나, 지하공간 중 유동인구가 가장 많은 지하철역에서 조차 침수에 대한 행동매뉴얼이나 대피에 대한 가이드라인이 마련되지 않은 것으로 나타났다. 따라서, 지하공간 침수를 방지하기 위하여 센서를 이용한 자동 차수판과 경보기 설치, 지하공간의 사람들이 안전한 대피로를 찾을 수 있도록 지상공간 및 지하공간 출입구를 모니터링 할 수 있는 CCTV의 설치, Dry Area를 두어 비상대피 할 수 있는 공간의 마련 등 시설적인 부분에 대하여 '지하공간 침수방지를 위한 수방기준'을 더욱 강화할 필요가 있으며, 지상공간의 침수 상황을 고려한 지하공간의 대피매뉴얼 또는 가이드라인 등의 수립이 필요하다. 또한 이와 더불어 재산 및 인명피해를 더욱 효율적으로 줄일 수 있도록 실시간 예 경보를 위한 침수해석 모형의 개발이 시급하다.

  • PDF

Calculation of the Normal Operation Rate of Monitoring Hardware in the Long Tunnels of High-Speed and Urban Railways (고속 철도와 도시철도 장대터널 계측기기의 정상 작동율 산정 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.80-90
    • /
    • 2022
  • Purpose: The objective of this study was to improve smart monitoring and monitoring management technology in long tunnels by investigating and analyzing the normal operation rates of monitoring hardware in the long tunnels of high-speed and urban railways. Method: This study evaluated, analyzed, and compared the normal operation rate of 6-8 types of monitoring hardware for each long tunnel, targeting three high-speed railway lines with a long tunnel (i.e., Suseo-Pyeongtaek Line, Gyeongbu Line, and Honam Line) and two urban railway groups with a long tunnel (i.e., Seoul Metro Lines 5, 6, and 7, and 9). Result: The rank of the normal operation rate of monitoring hardware was in the order of Suseo-Pyeongtaek High-Speed Railway (92.1%), Seoul Metro Lines 5, 6, and 7 (85.8%), Seoul Metro Line 9 (85.2%), Gyeongbu High-speed Railway (80.5%), and Honam High-speed Railway (46.7%). Conclusion: The mean normal operation rate of the monitoring hardware in the three high-speed railway long tunnels was 83.4%, and that of the two urban railway long tunnels was 85.5%, indicating that the deviation between them was small. The mean normal operation rate of the monitoring hardware in the long tunnels of the five high-speed and urban railway lines was 84.2%.