• Title/Summary/Keyword: 형광 X-선

Search Result 212, Processing Time 0.026 seconds

Comparative Analysis of the Characteristics of Natural Zeolites from Mongolia, Korea, and the United State (몽골, 한국, 미국 천연 제올라이트의 특성 비교 분석)

  • Battsetseg, Bayarsaikhan;Kim, Hu Sik;Kim, Young Hun;Kim, Jeong Jin;Lim, Woo Taik
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.35 no.2
    • /
    • pp.141-151
    • /
    • 2022
  • The 16 natural zeolites collected from Mongolia (6 types), the United States (1 type), and Korea (9 types) were characterized by XRD, XRF, TGA, DTA, and CEC analysis. All 16 samples are composite minerals. Two or more mineral phases co-exist and consist primarily of minerals such as clinoptilolite, heulandite, mordenite, and chabazite. In certain samples, minerals like illite and quartz were present as impurities. The XRF analysis showed that the 16 natural zeolites contain SiO2, Al2O3, K2O, CaO, Na2O, MgO, and Fe2O3 oxides. The cation exchange capacity of the U-1 sample was 223.3 meg/100 g, which is higher than the rest of the samples. M-6 sample in Mongolian natural zeolite and K-1 sample in Korean natural zeolite showed the highest cation exchange capacity at 166.6 meg/100 g. As a result of thermal differential and thermos gravimetric analysis, all 16 samples showed excellent thermal stability up to 600℃.

Dose Calculation of Heterogeneous Lung Tissue on 6MV X-ray Therapy (6MV X-선에 의한 폐조직의 심부선량변화와 임상응용)

  • 이경자;장승희;추성실
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.247-257
    • /
    • 1998
  • For effective radiotherapy, it should always be considered that calculation of different dose distribution in heterogenous tissue is important particularly on lung which has low density and large volume. To take precise dose distribution of 6MV X-ray in the thoracic cage, the authors had made a tissue equivalent phantom for thorax, measured dose distribution by thermoluminescent dosimeter and mm dosimeter, and derived methmetical equation coincided with provided theoretical formula. In comparision with isodose curve on case of homogeneous soft tissue, dose of heterogeneous lung tissue had been shown increase about 4% per cm depth on one and multiportal field, less than 15% difference on rotation field for esophagus, and around 20% difference on rotation field for lung according to the degree of rotation angle that must be corrected by dose compensation.

  • PDF

Buildup Characteristics of Radiophotoluminescent Glass Dosimeters with Exposure Time of X-ray (엑스선의 조사시간에 따른 형광유리선량계의 빌드업 특성)

  • Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.256-263
    • /
    • 2017
  • By using the buildup characteristics of the radiophotoluminescence glass dosimeter(RPLGD), it is aimed to help the measurement of the accurate dose by measuring the radiation dose according to the time of the glass element. Five glass elements were arranged on the table and the source to image receptor distance(SID) was set to 100 cm for the build-up radiation dose measurement of the fluorescent glass dosimeter glass element(GD-352M). Radiation doses and saturation rates were measured over time according to irradiation time, with the tube voltage (30, 60, 90 kVp) and tube current (50, 100 mAs) Repeatability test was repeated ten times to measure the coefficient of variation. The radiation dose increased from 0.182 mGy to 12.902 mGy and the saturation rate increased from 58.3% with increasing exposure condition and time. The coefficient of variation of the glass elements of the fluorescent glass dosimeter was ranged from 0.2 to 0.77 according to the X - ray exposure conditions. X - ray exposure showed that the radiation dose and saturation rate were increased with buildup characteristics, and degeneration of glass elements was not observed. The reproducibility of the variation coefficient of the radiation generator was included within the error range and the reproducibility of the radiation dose was excellent.

Study on Adsorption of Pb and Cd in Water Using Carbonized Water Treatment Sludge (탄화 정수 슬러지를 이용한 수중의 납과 카드뮴 흡착에 관한 연구)

  • Kim, Younjung;Kim, Daeik;Choi, Jong-Ha;Hong, Yong Pyo;Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.5
    • /
    • pp.238-243
    • /
    • 2017
  • In this study, water treatment sludge carbonized with $400^{\circ}C$ was tested as an adsorbent for the removal of Pb and Cd in water. The carbonized sludge was characterized by thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM), X-ray fluorescence spectrometry (XRF), and surface area analysis. Carbonized sludge exhibited much higher specific surface area and total pore volume than water treatment sludge itself. In batch-type adsorption process, carbonized sludge represented better adsorption performance for Pb than Cd, achieving 90~98% at the concentrations conducted in the experiments. Equilibrium data of adsorption were analyzed using the Freundlich and Langmuir isotherm models. It was seen that both Freundlich and Langmuir isotherms have correlation coefficient $R^2$ value larger than 0.95. The results of studies indicated that carbonized water treatment sludge by heat treatment could be used as an efficient adsorbent for the removal of Pb and Cd from water.

A study on the development of SRM for XRF analysis of PZT[$Pb(ZrTi)O_3$] (PZT[$Pb(ZrTi)O_3$]의 XRF 분석용 SRM 개발에 관한 연구)

  • Kim, Young Man;Jeong, Chan Yee;Lim, Chang Ho;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.439-444
    • /
    • 1997
  • Twelve kinds (1set) standard materials of chemical ingredients of lead zirconate titanate[$Pb(ZrTi)O_3$] have been developed in order to determine fast and accurate measurement of X-ray fluorescence spectrometry. Especially, we used diluted(ahout sixteen times) filling compound($Li_2B_4O_7/LiBO_2=4/1$) to consider removal effect of matrix, storage convenience, and homogenous characteristics. As a result from the four different laboratories, we obtained extremly good agreement about the standard curve on twelve standard materials which containing eleven elements, PbO, $ZrO_2$, $TiO_2$, SrO, $WO_3$, $La_2O_3$, $Cr_2O_3$, MgO, $Nb_2O_5$, and $MnO_2$. The correlation factor of standard curve was over 0.998. However, ZnO has relatively low correlation factor, 0.977, because the concentration was 10ppm lower than other original materials. This analysis reveals that ZnO has shown the poor linearity as well as low fluorescence intensity. In present work, XRF standard materials are useful for determining a rapid and accurate results for major and minor elements concentration among PZT.

  • PDF

Analysis of Surface Contaminants and Physical Properties of the Daejanggakgibi Stele of Silleuksa Temple using Non-destructive Technology (비파괴 기술을 활용한 여주 신륵사 대장각기비의 표면오염물 분석과 물성진단)

  • KIM, Jiyoung;LEE, Myeongseong
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.2
    • /
    • pp.186-197
    • /
    • 2022
  • The Daejanggakgibi Stele of Silleuksa Temple in Yeoju is a stone stele from the Goryeo Dynasty that is inscribed with various stories about the construction of Daejanggak, a place where Buddhist scriptures were kept. This stele has been maintained for a long time in a state in which discoloration of the body has occurred, and the inscription has been partially damaged due to dozens of cracks. Using non-destructive analysis methods for stone artifacts, material investigation, portable X-ray fluorescence analysis, and ultrasonic velocity analysis for the stele were performed. It was confirmed that the stele body was composed of light gray crystalline limestone, and the base stone, support stone, and cover stone were medium-grained biotite granite. Portable X-ray fluorescence analysis confirmed that iron(Fe) was an original coloring element of the stele surface. From the distribution pattern of the coloration, it can be inferred that iron-containing materials flew down from between the stele body and the cover stone. Thereafter, living organisms or organic contaminants attached to it so that yellow and black contaminants were formed. Ultrasonic diagnosis revealed that the physical property of both the front and back surfaces ranged from fresh rocks(FR) to completely weathered rocks(CW), and the average weathering index was grade 3(intermediate). However, the point where cracks developed intensively was judged to be the completely weathered stage(CW), and some cracks located in the upper and lower parts of the stele bear potentially very high risk. It is necessary to monitor the movement of these cracks and establish reinforcement measures for conservation in the future.

Mössbauer Spectroscopic Study of Non-figure Plain Coarse Pottery from Jeju Island (Mössbauer spectroscopy를 이용한 제주도 무문(無紋)토기의 연구)

  • Yoon, Tae-Gun;Ko, Jeong-Dae;Sung, Rak-Hong
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.1
    • /
    • pp.7-13
    • /
    • 2002
  • The studies of non-figure plain coarse pottery from Jeju island is very important because it can explain the characters of plain coarse potteries of the bronze age and the early iron age. In this study, We analyzed the non-figure plain coarse popery from Jeju island in two ways. One is analysis of the chemical composition using X-ray fluorescence spectrometer and X-ray diffraction, the other is analysts of clay mineral contained iron, oxidized iron's genus, valence state and magnetic properties using Mossbauer spectroscopy. We confidence that non-figure plain coarse pottery is chiefly made of silicate minerals, like SiO$_2$. The content of noncrystalline ferrihydrite is supposed to be below 5-10 wt%, non-figure plain coarse pottery is considered to partly consist of Jeju island clay, which is made of neutral volcanic rock and the valence state of iron is Fe$\^$2+/ and Fe$\^$3+/. We presume the reason that the magnetic hyperfine field is lower than that of pure goethite is the change of crystal structure which transforms the combination states of Fe ions while the clay is being fired.

Clinical Evaluation for System Performance of Image Intensifiers (상강화기의 임상평가)

  • Kim, Chang-Seon;Charles R. Wilson
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.143-154
    • /
    • 1998
  • The image intensifier is the key component which determines the imaging characteristics in a fluoroscopic imaging system. A system performance program for clinical evaluation of two image intensifiers, that is simple, non-invasive and time effective, was described. Tests were grouped into three headings: x-ray generator, image quality, and collimation. For the x-ray generator, the kVp accuracy and the automatic exposure control operation were compared. Low- and high-contrast resolution measurements, and mesh pattern study belong to the image quality tests and those tests were performed for the video monitor and photospot images. For the collimation, usable field diameter and image distortion of image intensifiers were measured and quantified. The procedures and the results are hoped to be used for the clinical evaluation of system performance and/or acceptance tests for image intensifiers.

  • PDF

Study for X-ray detector using liquid crystal modulator (Liquid crystal modulator를 이용한 엑스선 검출기에 관한 연구)

  • Heo, Seung-Uk;Cho, Sung-Ho;Kim, Yoon-Seok;Kim, Young-Bin;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.5-9
    • /
    • 2009
  • The trend of Digital x-ray Detector research is to improve resolution of image and to embody large area imaging as well as dynamic moving imaging, etc. This research is divided with indirect conversion method and direct conversion method by radiation conversion process. Each conversion method has problems such as decrease of resolution from light scattering in indirect method case and not only low system stability but also difficult in dynamic moving imaging in direct method case. X-ray detector using liquid crystal has been researching to solve these problems, but it is difficulty in uniform injection of liquid crystal because of its structural properties. Therefore, this study suggests the structure which solves present problem. Also the possibility of suggested structure was investigated using simulation.

  • PDF

A Study on Iron Compounds of Scoria in The Western Seaside Area of Jeju (제주 서부 해안지역 스코리아의 철 화합물에 관한 연구)

  • Choi, Won-Jun;Ko, Jeong-Dae
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.6
    • /
    • pp.227-232
    • /
    • 2009
  • Fe compounds of scoria samples distributed in the western seaside area of Jeju island were investigated by means of X-ray fluorescence spectroscopy (XRD), X-ray diffractometry (XRF) and $^{57}Fe$ Mossbauer spectroscopy. The samples were prepared from five parasite volcanos. We found that the samples were a typical basalt from the contents ratio of $SiO_2,\;Al_2O_3$ and Fe, and that they were silicate minerals. Underwater volcanoes scoria samples are shown only doublets in Mossbauer spectra and others scoria samples are shown sextets due to hematite and magnetite. And the balence state of Fe in the underwater volcanoes scoria samples are chiefly 2+ charge state with a little of the 2+ charge state. But the balence state of Fe in the others scoria samples are chiefly 3+ charge state.