• Title/Summary/Keyword: 형광 탐지

Search Result 27, Processing Time 0.027 seconds

Oil Fluorescence Spectrum Analysis for the Design of Fluorimeter (형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석)

  • Oh, Sangwoo;Seo, Dongmin;Ann, Kiyoung;Kim, Jaewoo;Lee, Moonjin;Chun, Taebyung;Seo, Sungkyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.304-309
    • /
    • 2015
  • To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluorescence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorimeter for the oil spill detection which has compact size and cost effectiveness. Before the detail design process, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spectrum results and drawn the each common spectrum regions of excitation and emission. In the experiments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters.

Design of a customizable fluorescence detection system for fluorescently labeled tumor cells (형광 발현 암세포 탐지를 위한 맞춤형 검출시스템 개발)

  • Cho, Kyoungrae;Seo, Jeong-hyeok;Choe, Se-woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.261-266
    • /
    • 2019
  • Flow cytometry is an electrical detection system that provides precise and diverse optical properties to cells and micro particles. Flow cytometry, which provides multidimensional information including cell size and granularity through light scattering and fluorescence emission generated by the induction of light of a specific wavelength to the fluorescently treated cells or micro particles, plays an important role in biomedical and biophysical fields. However, it has some drawbacks such as high cost, size of the instrument and limitation in selecting fluorescent dyes. Therefore, in this paper, a low cost compact fluorescent detection system is developed using light-emitting diode and microcontroller. The proposed fluorescence detection system has a replaceable the light source/fluorescence filter/photodetector and constructed by 3D printer, so that the user can design a customized system according to the selected fluorescent dyes. The fluorescence intensity was measured by varying the number of fluorescently labeled cells, and the measured intensities showed a high linearity within the tested concentration ranges.

DETECTION OF OCCLUSAL CARIES USING LASER FLUORESCENCE (레이저 형광법의 교합면 우식증 탐지 효과)

  • Kim, Chang-Gi;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.600-606
    • /
    • 2002
  • The purpose of this study was to evaluate the diagnostic validity of an incipient occlusal caries using argon laser fluorescence. Extracted human premolars and molars with enamel carious lesion of occlusal surface were assessed using visual examination, visual examination with probing, argon laser fluorescence and histologic depth of carious lesion. The results in each of all the three detection methods were compared to the assessment of histologic depth of carious lesion using polarized microscope. The results from the present study can be summarized as follows; 1. There was highly correlation between the histologic depth of occlusal caries and all three detection methods(P<0.01). 2. The reproducibility(kappa value) of the visual examination, visual examination with probing and argon laser fluorescence between the histologic depth of occlusal caries was 0.189, 0.128, 0.472. The highest correlation was seen between detection of occlusal caries by argon laser fluorescence and histologic scores by polarized microscope. The results from this study indicated that argon laser fluorescence considered to be accurate and reliable method in detecting occlusal caries.

  • PDF

DETECTION OF PROXIMAL CARIES USING LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증 탐지효과)

  • Mo, Kyung-Hee;Yoon, Jung-Hoon;Kim, Su-Gwan;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.323-330
    • /
    • 2004
  • The purpose of this study was to evaluate the diagnostic validity of early proximal caries lesions using laser fluorescence and whether the detection could be enhanced using a fluorescent dye. Direct visual examination and bitewing radiograph were used for comparison. The subjects of this study were 30 children of $3{\sim}9$ years old. Laser fluorescence and dye-enhanced laser fluorescence(mixed wavelength of 488 and 514 nm) were used and viewed through glasses(excluding wavelength<520 nm). For dye-enhanced laser fluorescence a 0.075% sodium fluorescein dye was applied before examination. Proximal caries lesion of each subject was assessed using visual examination, bitewing radiograph, laser fluorescence, and dye-enhanced laser fluorescence. The results in the three detection methods were compared to the assessment of bitewing radiograph. The results from the present study can be summarized as follows: 1. There was highly correlation(r=0.725-0.911) between the bitewing radiograph and all three detection methods(p<0.05) 2. The reproducibility(kappa value) of the visual examination, laser fluorescence and dye-enhanced laser fluorescence comparing with bitewing radiograph of proximal caries was 0.451, 0.683, 0.772, respectively. There was highest correlation between dye-enhanced laser fluorescence and bitewing radiograph for detection of proximal caries. The results from this study indicated that the dye-enhanced laser fluorescence considered to be accurate and reliable method in detecting proximal caries.

  • PDF

The Early Detection of the Gram Positive Bacteria using Sonification and Fluorescent Dye in the Field (현장에서 초음파 파쇄와 형광시약을 이용한 그람 양성균의 조기 탐지)

  • Ha, Yeon-Chul;Choi, Ki-Bong;Choi, Jung-Do
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.347-352
    • /
    • 2006
  • This study was carried out to establish the optimum condition for cell disruption with a sonificator in the detection of the gram positive bacteria, Bacillus globigii and Streptococcus epidermidis for the purpose of developing automatic fluorometer. The efficiency of sonificator on the Bacillus globigii and Streptococcus epidermidis disruption differed greatly according to the diameter of sonificator probe tip. The larger sonificator probe diameter showed greater disruption. Bacillus globigii was more disruptive than Streptococcus epidermidis. Sonificator probe of the 13 mm diameter was the most efficient one when sample was sonificated for 20 seconds. The detection limits of Bacillus globigii and Streptococcus epidermidis were $10^5CFU/m{\ell}\;and\;5{\times}10^5CFU/m{\ell}$ respectively when samples were sonificated for 20 seconds with a sonificator probe of 13 mm diameter.

Preparation and Radionuclide Detection Analysis of Inorganic Fluor Impregnated Double-layered Membranes (이중구조 무기형광 함침막 제조 및 방사성핵종 탐지능력의 분석)

  • 이근우;서범경;박진호;남석태;한명진
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.240-246
    • /
    • 2002
  • New polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The membranes were applied to detect the radionuclide contamination directly without the aid of a scintillation cocktail. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent or by exchanging solvent in the solution with nonsolvent in a coagulation bath. The prepared membranes had two distinguished, but tight1y attached, double layers: one is the supporting layer of dense polymer film and the other the detecting layer consisting of CAYS and polymer. The radionuclide counting results revealed that the prepared membranes were efficient to monitor radioactivity contamination with reliable counting ability.

DIAGNOSIS OF EARLY CARIES WITH DYE-ENHANCED LASER FLUORESCENCE (레이저 형광과 광활성제를 이용한 초기 우식증의 진단)

  • Lee, Sang-Ho;Han, Kuk-Jae;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • To evaluate the quantitative nature of laser fluorescence(LF) and dye-enhanced laser fluorescence(DELF) on early enamel caries, artificial caries were induced on the bovine enamels and argon laser was irradiated on the surfaces of lesions. Fluorescence radiance from enamel specimen was recorded with CCD camera which was connected to PC image analyzing system. The difference of fluorescence of radiance(DFR) between the carious and the sound enamel in each sample of the LF and the DELF groups were measured by image analyzing program. The DFR of lesion surfaces measured with laser fluorescence and lesion depths were evaluated and the results are as follows: The caries lesions were discriminated from sound enamels by the darkness with LF and by the brightness with DELF. The DELF was more sensitive than the LF at the earlier stage of demineralization.

  • PDF

The Early Detection of the Gram Negative Bacteria using Signification and Fluorescent Dye in the Field (현장에서 초음파 파쇄와 형광시약을 이용한 그람 음성균의 조기 탐지)

  • Ha, Yeon-Chul;Choi, Ki-Bong;Choi, Jung-Do
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.341-346
    • /
    • 2006
  • This study was carried out to establish the optimum condition for cell disruption with a sonificator in the detection of the gram negative bacteria, E. coli for the purpose of developing automatic fluorometer. The efficiency of sonification on the E. coli disruption was greatly dependent on the diameter of sonificator probe tip. The larger sonificator probe diameter showed greater disruption effect. Sonificator probe of 13 mm diameter was the most efficient one for E. coli when sonificated for 20 seconds. The efficiency of the E. coli disruption differed greatly according to the depth of sonificator probe tip sank in the sample solution. The shorter the distance between probe tip end and the bottom of the container, the higher the disruption efficiency. The detection limit of E. coli was $5{\times}10^5CFU/m{\ell}$ when sample was sonificated for 20 seconds with a sonificator probe of 13 mm diameter.

DETECTION OF EARLY PROXIMAL CARIES WITH LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증의 진단)

  • Seol, Jae-Heon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.236-246
    • /
    • 2004
  • Artificial carious lesions in various depths were observed with visual examination using light transillumination, bite-wing radiography, laser fluorescence, and dye-enhanced laser fluorescence to determine the reproducibility, correlation of each diagnostic method, diagnostic sensitivity and diagnostic specificity. And optical densities according to demineralized times were measured whether laser fluorescence could be used as a quantitative diagnostic method. The following results were obtained whether laser fluorescence could be used for diagnosis of initial proximal caries. 1. Tau-c values of visual examination was 0.08 which showed lowest reproducibility and those of bite-wing radiography, laser fluorescence, dye-enhanced laser fluorescence were 0.60, 0.48, and 0.64, respectively which showed relatively high reproducibility. 2. The correlation between demineralization time and each examination was the highest in dye-enhanced laser fluorescence$({\gamma}=0.51)$ followed by laser fluorescence$({\gamma}=0.43)$, bite-wing radiograph$({\gamma}=0.35)$, and visual examination$({\gamma}=0.33)$. Dye-enhanced laser fluorescence and laser fluorescence showed significant correlation with demineralization time. 3. The sensitivity of laser fluorescence and dye-enhanced laser fluorescence for diagnosing approximal caries based on bite-wing radiography were 67%, 100% and those of specificity were 57%, 11% which showed diagnostic specificity was relatively lower than sensitivity. 4. The difference in optical density(DFR) between sound teeth and carious lesions according to lesion depth was high with dye-enhanced laser fluorescence compared with laser fluorescence. DFR measured with laser fluorescence according to changes in lesion depth was statistically significant but was not statistically significant with dye-enhanced laser fluorescence. Based on these results, laser fluorescence and dye-enhanced laser fluorescence have comparable diagnostic power as bite-wing radiography in early diagnosis of proximal caries.

  • PDF

Application of Chlorophyll Fluorescence Parameters for the Detection of Water Stress Ranges in Grafted Watermelon Seedlings (수박접목묘의 건조스트레스 범위 탐지를 위한 엽록소형광 지수의 적용)

  • Shin, Yu Kyeong;Kim, Yong Hyeon;Lee, Jun Gu
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.461-470
    • /
    • 2019
  • This study was carried out to quantify the drought stress in grafted watermelon seedlings non-destructively by using chlorophyll fluorescence (CF) imaging technique rather than the visual judgment. Six-day old watermelon seedlings were grown under uniform irrigation for 3 days, and then given drought stress. Afterward, the sensor for the measurement of water content in plug tray cell unit was used to classify the drought-stress level into nine groups from D1 (53.0%, sufficient moisture state) to D9 (15.7%, extremely dry stress), and the 16 CF parameters were measured. In addition, re-irrigation was performed on the drought stressed seedlings(D5 - D9) to determine the growth and photosynthesis recovery level, which was not confirmed by visual judgment. The kinetic curve patterns of CF in three different drought stressed seedling groups were found to be different for the early detection of drought stress. All the 16 CF parameters decreased continuously with exposure to drought stress and drastically decreased from D5 (32.1%) where the visual judgment was possible. The fluorescence decline ratio (Rfd_Lss) started to decrease from the initial drought stress level (D5 - D6), and the Maximum PSII quantum yield (Fv/Fm) was significantly decreased in the later extreme drought stress range (D7 - D9) by re-irrigation recovery test. Thus, Rfd_Lss and Fv/Fm parameters were finally selected as potent indicators of growth and photosynthesis recovery in the initial and later stages of drought stress. Also, to the differences in the numerical values of the individual chlorophyll fluorescence parameters, the drought stress level was intuitively confirmed through the image. These results indicate that Rfd and Fv/Fm can be considered as potential CF parameters for the detection of low and extremely high drought stress, respectively. Furthermore, Fv/Fm can be considered as the best CF parameters for recovery at re-irrigation.