• Title/Summary/Keyword: 혈관 조영술

Search Result 336, Processing Time 0.029 seconds

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation (관상동맥 약물 방출 스텐트 삽입 후 스텐트 골절에 대한 임상결과 및 예후)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • Many studies have suggested that in the era of Drug-Eluting Stents(DES) are one of the causes of In-Stent Restenosis(ISR) of Stent Fracture(SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age $62.44{\pm}9.8$year, 0.68%). Fractures of Sirolimus-Eluting Stents(SES), Paclitaxel-Eluting Stents(PES), Biolimus A9-Eluting Stents(BES), Everolimus-Eluting Etents(EES), Endothelial Progenitor Cell Capture Stent(EPC) and Zotarolimus-Eluting Stents(ZES) are accounted for 19(59.4%), 9(28.1%), 2(6.3%), 1(3.1%), 1(3.1%) and 0(0%) respectively. SF developed in the left Anterior Dscending(LAD) artery in 16 patients(50%) and in complex(type B2, C) lesions in 25 patients(69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES(3 patients), plain old balloon angioplasty(3 patients), or conservative medical treatment(17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of $32.9{\pm}12.4$ months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

Findings of Digital Subtraction Angiography after Vascularized Fibular Grafting for Osteonecrosis of Femoral Head (대퇴골두 무혈성 괴사에 대한 혈관부착 비골 이식술 후 디지털 감산 혈관조영술 소견)

  • Lee, Kee-Haeng;Kim, Youn-Soo;Lee, Hae-Giu;Ok, Ji-Hoon;Kim, Bae-Kyun;Kim, Hyoung-Min
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.2
    • /
    • pp.130-135
    • /
    • 2004
  • Purpose : To observe the patency of anastomosis site and the findings of circulation of grafted fibula in osteonecrosis of femoral head treated with vascularized fibular graft by use of digital subtraction angiography. Materials and Methods : 17 cases of 11 patients who underwent vascularized fibula graft for osteonecrosis of femoral head. We performed digital subtraction angiography(DSA) for them at second week postoperatively in 12 cases, at sixth week in 1 case, at sixth month in 2 cases, at twelfth month in 1 case, and eighteenth month in 1 case which had been got DSA at second week before. We observe the patency of pedicle, and the circulation of grafted fibula such as periosteal and intraosseous vessels with time. Results : All cases except one which were thought failure of selective angiogram showed good passage of blood flow through anstomosed pedicle on DSA. We found the differences in appearance of circulation of grafted fibula with time. DSA at 2nd and 6th week postoperatively revealed both of periosteal and intraosseous vessels along the fibula and blood pooling at the tip of fibula. DSA at 6th month showed maintenance of periosteal and intraosseous vessels along the fibula but did not clearly reveal blood pooling at the tip of fibula. The findings of DSA at 12th and 18th month were similar each other. The periosteal vessels were not seen as the grafted fibular bone were incorporated into surrounding femoral bone but intraosseous vessels were still seen. Conclusion : It was thought that DSA could be used for evaluation of the status of pedicle including anastomsed site and vessels of grafted fibula with time. The periosteal vessels of fibula were decreased with time but intraosseous vessels were still seen until 18th month after vascularized fibula graft.

  • PDF

Successful Renal Autotransplantation for the Treatment of Severe Renovascular Hypertension in a 14-year-old Boy (신 자가이식을 통한 14세 소년에서 발생한 심한 신성 고혈압의 성공적인 치료)

  • Ji, Min-Chul;Park, Se-Jin;Choi, Jae-Young;Ko, Young-Guk;Kim, Myoung-Soo;Kim, Ji-Hong;Shin, Jae-Il
    • Childhood Kidney Diseases
    • /
    • v.14 no.2
    • /
    • pp.223-229
    • /
    • 2010
  • Percutaneous transluminal renal angioplasty (PTRA) is the current treatment of choice for renal artery revascularization, but renal autotransplantation has been an alternative treatment for complex cases. Here we report a 14-year-old boy with severe hypertension successfully treated with PTRA and renal autotransplantation. Doppler ultrasonography and computed tomography (CT) angiography revealed slight narrowing in the right renal artery ostium and complete obstruction in the left renal artery ostium with multiple collaterals. PTRA with stent insertion was performed for the treatment of the right renal artery, but it was impossible for the left renal artery due to the total obstruction. Therefore, left nephrectomy for autotransplantation was done with the peritoneal approach and the left kidney was autotransplanted to the ipsilateral iliac fossa. Postoperatively, Doppler ultrasonography and mercapto-acetyl-triglycine (MAG-3) renogram were performed, which showed normal renal artery blood flow and kidney function. Blood pressure was normalized and anti-hypertensive drugs were gradually tapered. Fibromuscular dysplasia was suspected to be responsible for the renal artery stenosis based on clinical aspects. In conclusion, renal autotransplantation is also a good treatment option for children with severe renovascular hypertension when endovascular treatment has failed or is not possible.

A Case of Primary Pulmonary Hypertension in Pregnancy Presented as Massive Hemoptysis (임신 중 대량객혈로 발현된 원발성 폐고혈압 1예)

  • Kim, Myung Sook;Kim, Hyoung Doo;Kim, Seok Chan;Kwan, Soon Suk;Kim, Young Kyoon;Kim, Kwan Hyoung;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.1
    • /
    • pp.66-71
    • /
    • 2004
  • Primary pulmonary hypertension (PPH) is a rare, progressive and incurable disease, which is characterized by an increase in the pulmonary artery pressure without a demonstrable cause. The most common presenting symptom is dyspnea on exertion, with other symptoms comprising of chest pain, syncope and hemoptysis. The diagnosis is one of exclusion of any of the known causes of pulmonary hypertension. When associated with pregnancy, the maternal mortality ranges from 30 to 50%. Because pregnancy and labor are very serious problems for patients with PPH, the available evidence suggests that pregnancy when afflicted with PPH should be avoided. In account the case of a 33-year old patient, reporting with massive hemoptysis, and diagnosed with PPH during her twenty seventh week of gestation, is presented. She was treated with conservative management, including oxygen and a vasodilator, and underwent a pregnancy termination. However, due to aggravation of right heart failure, she presented with severe systemic hypotension and hypoxemia, and eventually died. This case is reported, with brief review of the literature.

GORHAM-STOUT DISEASE OF THE MANDIBLE: A CASE REPORT (하악골에 발생한 Gorham-Stout 증후군: 증례 보고)

  • Ji, Young-Min;Song, Gin-Ah;Shin, Jung-Hyun;Pang, Kang-Mi;Kim, Soung-Min;Myoung, Hoon;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin;Hwang, Soon-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.572-576
    • /
    • 2008
  • Gorham-Stout disease is a rare skeletal disease which is progressive and spontaneous and idiopathic resorption of whole body bone. In the initial stage, the osteolytic site is replaced by histologically benign vascular proliferation without new bone formation and finally by dense fibrous tissues. We encountered with a patient involving the mandible with attention by the clinical, radiographic, scintigraphic, angiographic, and computed tomography. We resected the mandibular lesion which was reconstructed with a fibular free flap. We report literature review with a mandibular lesion involved with Gorham-Stout disease.

Assessment of Patency of Coronary Artery Bypass Grafts Using Segmented K-space Breath-hold Cine Cardiovascular Magnetic Resonance Imaging: A Clinical Feasibility Study (호흡멈춤상태에서 K-space분할 CINE 자기공명 영상기법을 이용한 관상동맥우회로의 혈류개방성의 검사)

  • Oh-Choon Kwon;Sub Lee;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.1
    • /
    • pp.22-30
    • /
    • 2003
  • Purpose : The efficacy of magnetic resonance imaging for evaluating coronary artery disease has been reported. In this study, we evaluated the usefulness of breath-hold segmented K-space cine MR imaging for evaluating the patency of coronary artery bypass grafts (CABG). Materials and Method s : Thirty eight patients with a total of 92 CABGs (36 internal thoracic arteries and 56 saphenous vein grafts) were evaluated using segmented K-space cardiac-gated fast gradient echo sequence (2D-FASTCARD) MR imaging. MR magnitude images were evaluated from the hard copies by two independent observers. A graft was defined as patent if it was seen as a bright small round area on at least two consecutive images throughout the cardiac cycle at a position consistent with the expected location for that graft. Results : MR images were obtained successfully for 23 patients (61%). The sagittal planes were most helpful in visualizing the cross-section of sapheneous vein bypass graft to left circumflex artery branch, whereas the transverse planes were used for identification of internal mammary artery grafts to left anterior descending coronary artery or its branch and identification of saphenous vein grafts to right coronary artery. Forty five grafts were visible using this MR technique, while the grafts were not visible on seven saphenous vein grafts and two internal mammary artery grafts. In two patients showing symptoms of myocardial ischemia, one or two bypass grafts were not visible. Imaging, perpendicular plane to a CABG was important to visualize the flow inside the CABG with maximum sensitivity. Conclusion : Evaluation of patency of the bypass graft was clinically feasible by 2D-FASTCARD MR imaging, whereas any invisible bypass grafts should be further studied by contrast-enhanced MR angiography or by conventional angiography for confirmation of abnormalities.

  • PDF

Korean Clinical Imaging Guidelines for the Appropriate Use of Chest MRI (한국형 흉부 MRI 영상 진단 정당성 권고안)

  • Jiyoung Song;Bo Da Nam;Soon Ho Yoon;Jin Young Yoo;Yeon Joo Jeong;Chang Dong Yeo;Seong Yong Lim;Sung Yong Lee;Hyun Koo Kim;Byoung Hyuck Kim;Kwang Nam Jin;Hwan Seok Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.562-574
    • /
    • 2021
  • MRI has the advantages of having excellent soft-tissue contrast and providing functional information without any harmful ionizing radiation. Although previous technical limitations restricted the use of chest MRI, recent technological advances and expansion of insurance coverage are increasing the demand for chest MRI. Recognizing the need for guidelines on appropriate use of chest MRI in Korean clinical settings, the Korean Society of Radiology has composed a development committee, working committee, and advisory committee to develop Korean chest MRI justification guidelines. Five key questions were selected and recommendations have been made with the evidence-based clinical imaging guideline adaptation methodology. Recommendations are as follows. Chest MRI can be considered in the following circumstances: for patients with incidentally found anterior mediastinal masses to exclude non-neoplastic conditions, for pneumoconiosis patients with lung masses to differentiate progressive massive fibrosis from lung cancer, and when invasion of the chest wall, vertebrae, diaphragm, or major vessels by malignant pleural mesothelioma or non-small cell lung cancer is suspected. Chest MRI without contrast enhancement or with minimal dose low-risk contrast media can be considered for pregnant women with suspected pulmonary embolism. Lastly, chest MRI is recommended for patients with pancoast tumors planned for radical surgery.

Evaluation of Embolization Effect of Hepatocellular Carcinoma by Hepatic Arterial Flow Study with $^{99m}Tc$-MAA SPECT (간암에서 색전술의 효과를 평가하는데 있어서 $^{99m}Tc$-MAA SPECT를 이용한 간동맥 혈류 검사의 의의)

  • Lee, Byung-Hee;Yoo, Hyung-Sik;Lee, Jong-Doo;Chung, Jin-Ill;Park, Chang-Yun;Lee, Jong-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.62-68
    • /
    • 1994
  • This study was aimed to compare the density of the functional microcirculation of hepatocellular carcinoma (HCC) with normal liver and to investigate the effect of hepatic-arterial oily chemoembolization (HAE) by radionuclide examination. Methods : Eight patients with HCC proven by biopsy in five, and clinically and radiologically in three were included. The mixture of 2 cc normal saline with three to four mCi of $^{99m}Tc$-MAA was infused through a hepatic-arterial catheter for a minute. Dynamic images were obtained at a rate of 4 sec per frame for a minute, and static images and SPECT were followed. Results : In three patients who underwent hepatic arterial angiography (HAA) alone, radioactivity was markedly increased in tumors compared to the adjacent liver immediately after infusion of $^{99m}Tc$-MAA. The ratios of tumoral and extratumoral up-take (T/E ratio) were above 6.5 (range; $6.5{\sim}l9$, mean; 12.5). In four of the five patients who under-went superselective HAE, T/E ratio were remark-ably decreased ($0.5{\sim}1.3$). The areas of embolization were better delineated in radionuclide study than in postembolization HAA. In the other one who was considered to be embolized completely on HAA, strong radiouptake in the tumor was disclosed (T/E ratio; 7.0). Conclusions : Therefore hepatic-arterial flow study with radionuclide imaging using $^{99m}Tc$-MAA can be a valuable method to assess the accurate embolization effect in HCC.

  • PDF

Prognostic Analysis of Drug-Eluting Balloon Catheter and Drug-Eluting Stent for In-Stent Restenosis of Drug-Eluting Stent (스텐트 재협착 병변에서 약물코팅 풍선카테터과 약물용출 스텐트의 예후 분석)

  • Lee, Doo Hwan;Song, Jong Nam;Park, Sin eui;Choi, Nam Gil;Han, Jae Bok;Kim, In Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.381-389
    • /
    • 2019
  • Although the development of Drug-eluting stent (DES) improved the ISR significantly more than the Bare metal stent (BMS), the coronary stent restenosis (ISR) treatment still has a high recurrence rate. This study is compared the efficacy of DEB with that of DES implantation in patients with ISR. Among 4,316 patients who underwent coronary stent implantation at the Chonnam National University Hospital between November 2012 and December 2016, 187 patients developed ISR on follow-up coronary angiography ($66.3{\pm}11.0years$, 123 males) were enrolled and divided into two groups according to revascularization method as group I (DEB group; n=127) and group II (DES group; n=60). Primary end point was defined as major adverse cardiac events (MACEs), composite of cardiac death (CD), myocardial infaction (MI), target lesion revascularization (TLR) and stent thrombosis (ST) during two-year follow-up between the two groups. There were no differences in the baseline characteristics and angiographic findings except that prevalence of device length was shorter ($21.1{\pm}5.3$ vs. $25.3{\pm}9.6 mm$, p<0.002) in group I.Two-year MACE were not different in the two groups (8.7%vs.10.0%, p=0.789). The incidences of cardiac death (0%vs.0%, p=1.000), MI (1.6%vs.6.7%, p=0.085), TLR(8.7% vs. 10.0%, p=0.789) and ST (0% vs. 0%, p=1000). DEB demonstrated comparable risk reduction for MACEs compared with DES in patients with ISR during two-year follow-up. DEB might be good alternative for the treatment of ISR in patients with ISR.

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.