• Title/Summary/Keyword: 혈관 조영술

Search Result 336, Processing Time 0.021 seconds

Coronary Artery Dissection Secondary to Blunt Chest Trauma - A Case Report- (흉부 둔상에 의한 관상 동맥 박리 -1례 보고-)

  • 서강석;조용근;이종태
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.66-68
    • /
    • 1998
  • A 27-year-old male presented with an anterior myocardial infarction following blunt chest trauma sustained in motorcycle accident. On examination, there was no visible wound on the chest wall. Echocardiogram showed dyskinesia over anterior left ventricular wall. Subsequent coronary angiogram demonstrated dissection at the proximal portion of the left anterior descending coronary artery and left ventriculogram showed apical anerysm and thrombus. He was treated by coronary artery bypass graft.

  • PDF

Cord-like Atresia of the Abdominal Aorta Due to Takayasu Arteritis in Middle Aged Woman - A case Report - (중년 여자 환자에서 Takayasu 동맥염에 의한 복부 대동맥의 삭양 폐쇄 - 수술치험 1례-)

  • 이봉근;조성래;조봉균;이재화;조영덕
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.870-874
    • /
    • 2001
  • Takayasu arteritis is a chronic non-specific inflammatory arteriopathy that involves primarily the first branches of aortic arch but may also affect the aorta and any of its primary branches. A characteristic trait of the disease is that most of the patients are young females of mainly Asian and South American origin. Recently, we experienced a rare case of Takayasu arteritis which showed a cord-like atresia of abdominal aorta just below renal arteries in 52-year-old woman. We performed a side to side bypass graft from descending thoracic aorta to abdominal aorta just above the aortic bifurcation with a 18mm PTFE(polytetrafluoroethylene) vascular graft. The postoperative course was uneventful. .

  • PDF

Iatrogenic Large Esophageal Perforation Caused by Sengstaken-Blackmore Tube (식도 정맥류 출현 환자에서 Sengataken-Blackmore관에 의한 의인성 거대 흉부식도 파열)

  • 윤영철;조광현;권영민;전희재;최강주;이양행;황윤호
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.51-54
    • /
    • 2003
  • This patient was an 53-year-old man who had undergone Sengstaken-Blackmore tube insertion for esophageal varix bleeding. Two days after Sengstaken-Blackmore tube insertion, he developed severe left hemothorax and was transferred to our hospital. The esophagoscopic findings revealed a large perforation lengthening 8-cm in the intrathoracic esophagus. A left thoracotomy was performed 33 days after the injury due to repeated varix bleedings and poor conditions. An 8-cm longitudinal perforation of the intrathoracic esophagus with gross suppurative empyema was found. Primary repair and esophageal exclusion was performed 2cm proximal and distal to the perforation, using rows of nonabsorbable staplers(TA stapler 60 $\times$ 4.8) and large bore thoracostomy tubes were placed for local drainage. Six days after intrathoracic esophageal exclusion, an esophagogram revealed a leakage at just above the proximal stapling site. A cervical esophageal exclusion was performed using the same method. One hundred thirty seven days after exclusion operation for the intra-thoracic esophageal perforation, the patient was able to eat per orally without any secondary esophageal reconstructive surgery.

A Study of Changes of Pulmonary Artery Size after Bidirectional Cavopulmonary Shunt (양방향성 상대정맥-폐동맥 단락술 후의 폐동맥 크기 변화에 관한 연구)

  • 지현근;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.495-503
    • /
    • 1996
  • The bidirectional cavopulmonary shunt may be useful as an intermediate procedure before Fontal oper- ation in high-risk patients, because it provides adequate relief of cyanosis and relief of ventricular volume overload. But there are no established theory about the effects of bidirectional cavopulmonary shunt on pulmonary arterial development. The purpose of this article is a study of changes of pulmonary artery size after bidirectional cavopulmonary shunt. Ca diac catheterization and angiography procedures were done on 19 patients who underwent bidirectional cavopulmonary shunt from February 1992 to July 1994, their results were reviewed. Preoperative cardiac catheterization and angiography procedures were performed at a mean interval of ).8 $\pm$4.8($\pm$SEM) months before surgery and following catheterization at a mean postoperative interval of 19.6 $\pm$4.8 months. Pulmonary arterial sixte measurement were standardized for body surface area(Pulmon- arty artery index), and for diameter of descending thoracic aorta(McGoon ratio). Patient's age, body stir- face area, pulmonary angioplasty, preoperative McGoon ratio and follow-up intervals were considered as variables. Before bidirectional cavopulmonary shunt, patient's mean age, body surface area, arterial 02 saturation, diameter of right pulmonary artery, diameter of left pulmonary artery, pulmonary artery Index, McGoon ratio were 13.7$\pm$15.6 months, 0.40$\pm$0.12m2, 71.4$\pm$12.4m2, 7.1$\pm$1.7mm, 6.2$\pm$1 , 191.8$\pm$82.7mm21m2, 1.73 $\pm$0.49, respectively. After bidirectional cavopulmonary shunt, the values were changed to 39.9 $\pm$ 16.2 months, 0.58$\pm$0.07 m2, 83.0$\pm$3.8m2, 9.0$\pm$ 1.5 mm, 7.7$\pm$2.0, 197.3$\pm$57.1 mm2/m2, 1.76$\pm$0.32, respect- ively With patients'development (age, body surf'ace area), diameters of pulmonary arteries were increased, but pulmonary artery indices and McGoon ratios were not changed. And there were no effects of age, body surf'ace area, amount of increased 02 saturation, pulmonary angiography and follow-up duration on the increment of pulmonary ar- tery size. But when the McGoon ratio was as low as 1.2, there were significant increase in postoperative pulmonary artery sizes. There was a significant correlation between preoperative pulmonary artery index (PAI) and McGoon ratio (MGR) ; PAI : MGRxl18.0-12.4 In conclusion, bidirectional cavopulmonary shunt provides adequate increment of arterial 02 saturation and does not increase the pulmonary artery size. Further investi ation is mandatory to evaluate the effect of pulsatile bidirectional cavopulmonary shunt on pulmonary artery growth.

  • PDF

Severe Tricuspid Insufficiency after Correction of Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery(ALCAPA) (ALCAPA 교정후 발생한 심한 삼첨판 폐쇄부전)

  • 백만종;김웅한;오삼세;류재욱;공준혁
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.724-728
    • /
    • 2001
  • We report a case of an 8 years and 11 month-old male patient who had developed severe tricuspid insufficiency(TI) after correction of anomalous origin of the left coronary artery from the pulmonary artery(ALCAPA). Transthoracic echocardiogram and coronary angiography confirmed ALCAPA, ischemic mitral regurgitation and trivial TI. He underwent direct reimplantation of the left coronary artery to the aortic root by using additional cannulation at the main pulmonary artery for arterial inflow and cardioplegia delivery to the left coronary artery. After the correction of ALCAPA, transesophageal echocardiogram(TEE) revealed good antegrade flow at the aortic implantation site of the left coronary artery and severe TI(Gr III-IV/IV). Cardiopulmonary bypass was reestablished and tricuspid valve was repaired with Kay-type annuloplasty, artificial chordae formation and chordal shortening plasty. The postrepair TEE revealed trivial to mild TI.

  • PDF

Segmentation of Liver on MDCT Image (MDCT 영상에서 간의 추출)

  • Seo Jeongjoo;Ryu Gangmin;Fei Yang;Park Jongwon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.07b
    • /
    • pp.802-804
    • /
    • 2005
  • 제안된 연구에서는 기존의 일반 CT(Computerized tomography) 영상이 아닌 MDCT(Multi Detector CT) 영상을 이용하여 장기 추출에 관한 연구를 진행하였다. 조영제를 이용한 복부 MDCT 영상으로부터 모폴로지(morphology) 기법을 통해 간에 근접한 노이즈를 제거하고, 기존의 Otsu threshold를 개선하여 간의 명암값 분포를 구분할 수 있는 임계치를 구하였다. 찾아진 임계치를 이용하여 영상을 이진화하고, 최종적으로 위치정보를 이용하여 간에 해당하는 부분들을 추출하였다. 이러한 방식은 명암값과 위치정보를 이용하여 간을 추출한 후 다시 노이즈 문제를 해결하는 기존의 알고리즘과 비교했을 때, 처리 방식이 단순해지고 속도가 향상되었다. 추출된 간은 간 이식술이나 절제술에 필요한 간 내부의 혈관 인식과 간의 부분체적 계산 연구에 중요한 정보로 사용될 수 있을 것이다.

  • PDF

Fibrocalcific Embolism of Right Coronary Artery Combined with Aortic Valvular Stenosis (대동맥판협착증에 동반된 우관상동맥의 석회성 색전증)

  • 장성욱;박정옥;김영권;이명용;류재욱;박성식;서필원;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.858-861
    • /
    • 2003
  • The main cause of ischemic heart disease combined with aortic valve disease is the systemic atherosclerotic process. Coronary artery embolism by a particle from the calcified aortic valvular tissue is very rare. A 73-year-old female patient was admitted due to chest tightness of recent onset. Two dimensional echocardiogram showed severe calcific aortic valve stenosis. Preoperative coronary angiogram exhibited a stenotic lesion at the distal right coronary artery, which seemed to be embolic in origin. The coronary embolus was removed through the coronary arteriotomy and then the arteriotomy site was repaired by onlay patch angioplasty technique. Aortic valve was replaced by a bioprosthetic valve. The embolus was reported as a fibrocalcified particle of diseased valve.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Visualization of Borderline Coronary Artery Lesions by CT Angiography and Coronary Artery Disease Reporting and Data System (관상동맥 질환 판독과 자료 체계와 CT 혈관조영술에서의 경계성 관상동맥 병변)

  • Hyewon Park;Yu-Whan Oh;Ki Yeol Lee;Hwan Seok Yong;Cherry Kim;Sung Ho Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.297-307
    • /
    • 2024
  • Coronary artery disease (CAD) narrows vessel lumens at the sites of atherosclerosis, increasing the risk of myocardial ischemia or infarction. Early and accurate diagnosis of CAD is crucial to significantly improve prognosis and management. CT angiography (CTA) is a noninvasive imaging technique that enables assessment of vascular structure and stenosis with high resolution and contrast. Coronary CTA is useful in the diagnosis of CAD. Recently, the CAD-reporting and data system (CAD-RADS), a diagnostic classification system based on coronary CTA, has been developed to improve intervention efficacy in patients suspected of CAD. While the CADRAD is based on CTA, it includes borderline categories where interpreting the coronary artery status solely based on CTA findings may be challenging. This review introduces CTA findings that fall within the CAD-RADS categories that necessitate additional tests to decide to perform invasive coronary angiography and discusses appropriate management strategies.

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.