• Title/Summary/Keyword: 혈관영상

Search Result 749, Processing Time 0.032 seconds

Radiologic Approach for Pulmonary Vasculitis (폐혈관염의 영상의학적 접근)

  • Chohee Kim;Yoon Kyung Kim;Joungho Han
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.791-807
    • /
    • 2021
  • Vasculitis is a systemic disease, characterized by inflammation of the vascular wall. Although rare, it is sometimes life-threatening due to diffuse pulmonary hemorrhage or acute glomerulonephritis. Besides primary vasculitis, whose cause is unknown, numerous conditions such as autoimmune diseases, drugs, infections, and tumors can cause secondary vasculitis. Vasculitis displays various non-specific symptoms, signs, and laboratory findings; hence, diagnosis of the disease requires integration of various results including clinical features, imaging findings, autoantibody tests, and pathological findings. In this review, we have discussed the clinical, radiologic, and pathological features of vasculitis. Further, we elaborated the imaging findings and differential diagnosis of typical vasculitis that frequently involves the lung and introduced a new international classification of vasculitis, the Diagnostic and Classification Criteria in Vasculitis.

Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program (영상 분석 프로그램을 이용한 관상동맥 혈관 조영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.111-120
    • /
    • 2020
  • Research should be actively conducted for the ability of X-ray equipment and Retrospective image analysis of X-ray equipment used in hospitals. Retrospective image analysis of X-ray machines, CT and MRI of radiology and medical equipment has been actively conducted. However, image quality measurement using angiography equipment of angiography room is mostly measured with phantom, and image quality measurement on image after being taken by actual patient is insufficient and researches on accurate image quality measurement method are remarkable. It is in short supply. Therefore, through this study, the researcher devised a method to measure the image quality of the acquired image after coronary angiography, and to provide a high quality image to the operator. The equipment and programs used were angiographic examination equipment (Axiom Artis Zee Ceiling) and Image J program. Subjects were images automatically saved in PACS program after coronary angiography.For image quality measurement, selected the AP Caudal 30° image that show the LCA vessel well and the LAO 30° image that show the RCA vessel well during the coronary angiography. In order to measure the background and ROI of the selected image by selecting an image, a criterion on how to find and measure a section where the overlap of the shadow, such as blood vessel, liver and lung is minimized, is presented. In conclusion, there is no exact standard for analyzing an image quality measurement method of angiography image. Therefore, in order to provide quality images to the practistioners, not only the technicians of the equipment but also the users who actually use them should become researchers and conduct research on image quality measurement in various ways. Thus, it is expected to provide excellent images to patients.

Endovascular Treatment for Vascular Injuries of the Extremities (사지 혈관 손상의 인터벤션 치료)

  • Tae Won Choi;Yohan Kwon;Jinoo Kim;Je Hwan Won
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.846-854
    • /
    • 2023
  • Vascular injuries of the extremities are associated with a high mortality rate. Conventionally, open surgery is the treatment of choice for peripheral vascular injuries. However, rapid development of devices and techniques in recent years has significantly increased the utilization and clinical application of endovascular treatment. Endovascular options for peripheral vascular injuries include stent-graft placement and embolization. The surgical approach is difficult in cases of axillo-subclavian or iliac artery injuries, and stent-graft placement is a widely accepted alternative to open surgery. Embolization can be considered for arterial injuries associated with active bleeding, pseudoaneurysms, and arteriovenous fistula and in patients in whom embolization can be safely performed without a risk of ischemic complications in the extremities. Endovascular treatment is a minimally invasive procedure and is useful as a simultaneous diagnostic and therapeutic approach, which serve as advantages of this technique that is widely utilized for vascular injuries of the extremities.

Extraction of Coronary Arteries Wall based on Wavelet in IVUS Image (IVUS영상에서 웨이블릿 기반의 관상동맥 벽의 추출)

  • Lee, Na-Young;Kim, Gye-Young
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11b
    • /
    • pp.940-942
    • /
    • 2005
  • 혈관내부의 초음파는 혈관 벽(vessel wail) 전체를 관찰할 수 있는 단면적 영상(cross-sectional image)으로부터 혈관 벽의 서로 다른 층을 평가할 수 있다. IVUS(Intravascular Ultrasound)영상은 잡음에 매우 민감하고 해상도가 낮기 때문에 혈관 벽의 서로 다른 층을 구분된다. IVUS영상이 내강, 혈관 벽, 외막을 둘러싸는 영역으로 구성되어있다고 가정하면 내부와 외부의 두 경계선으로 구분할 수 있다. 따라서 본 논문에서는 IVUS영상을 웨이블릿 변환하여 주파수 공간에서 관상동맥 벽의 두 경계선을 추출한다. 실험결과를 통하여 관상동맥 벽의 두 경계선이 잘 추출되는 것을 확인할 수 있다.

  • PDF

Primary Angiosarcoma of the Mesentery: A Case Report (장간막에서 발생한 원발성 혈관육종: 증례 보고)

  • Hyeon Wook Kang;Ji Yeol Shin;Ju Wan Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.423-427
    • /
    • 2020
  • Angiosarcoma is a malignant endothelial cell tumor of lymphatic or vascular origin and is most commonly found in the skin and soft tissue. Primary mesenteric angiosarcoma has rarely been reported. Here, we present a case of primary mesenteric angiosarcoma manifesting as a gradually enhancing mass along with necrosis and hemorrhage.

Pulmonary vascular Segmentation and Refinement On the CT Scans (컴퓨터 단층 촬영 영상에서의 폐혈관 분할 및 정제)

  • Shin, Min-Jun;Kim, Do-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.3
    • /
    • pp.591-597
    • /
    • 2012
  • Medical device performance has been advanced while images are expected to be acquired with further higher quality and pertinent applicability as images have been increasing in importance in analyzing major organs. Recent high frequency of image processing by MATLAB in image analysis area accounts for the intent of this study to segment pulmonary vessels by means of MATLAB. This study is to consist of 3 phases including pulmonary region segmentation, pulmonary vessel segmentation and three dimensional connectivity assessment, in which vessel was segmented, using threshold level, from the pulmonary region segmented, vessel thickness was measured as two dimensional refining process and three dimensional connectivity was assessed as three dimensional refining process. It is expected that MATLAB-based image processing should contribute to diversity and reliability of medical image processing and that the study results may lay a foundation for chest CT images-related researches.

Angiosarcoma of the Breast and Spleen: A Case Report with Imaging and Pathologic Findings (유방 및 비장의 혈관육종: 영상 소견 및 병리 소견을 포함한 증례 보고)

  • Jieun Kim;Hyun Kyung Jung;Woogyeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1310-1314
    • /
    • 2021
  • Angiosarcoma of the breast is a rare malignant sarcoma of endovascular origin that presents with various radiological findings. We encountered a case of angiosarcoma of the breast presenting as an irregular indistinct hyperechoic mass on ultrasonography, with a large single angiosarcoma of the spleen in a previously healthy 36-year-old female. Herein, we report the imaging and pathologic findings and review the literature.

Epithelioid Hemangioendothelioma Presenting as a Right Paratracheal Mass: A Case Report (우측기관주위의 종격동 종괴로 나타난 상피양 혈관내피종: 증례 보고)

  • Pa Hong;Jae Seok Lee;Kyung Soo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1373-1379
    • /
    • 2022
  • Epithelioid hemangioendothelioma (EHE) is a low-grade malignant vascular neoplasm that can occur anywhere in the body. EHE has a low annual incidence (0.38/106) and prevalence (< 1/106), and primary mediastinal EHE is exceedingly rare. We report a case of EHE in a 53-year-old female which manifested as an incidentally discovered mass in the right paratracheal region. In this report, authors describe the pathological and radiological findings of primary mediastinal EHE invading the superior vena cava in the right paratracheal area.

Automated Tracking of Blood Vessel in ICG Retinal Image By Presumption of Feature Points (ICG 망막영상에서 특징점 추정에 의한 혈관의 자동추적)

  • Lim, Moon-Cheol;Cho, Goon-Jung;Kim, Woo-Saeng
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.902-906
    • /
    • 2000
  • 망막 혈관 구조의 분석은 망막에 관련된 환자의 진단 및 치료에 중요한 정보를 제공하기 때문에 다양한 연구가 진행되어 왔다. 본 연구에서는 ICG(IndoCyanine Green) 기술을 이용한 망막 영상의 혈관 구조를 분석하기 위해 원의 방정식으로 묘사된 혈관 영역 에너지 함수와 분기점 추정 템플릿을 사용하여 혈관의 특징점들을 추정한 후 혈관의 형체(body)를 자동으로 추적하는 동시에 분기점을 추출하는 방법을 제안한다. 전체 혈관의 자동추적과 분기점 추출을 가능하게 하는 특징점 추정 방법과 혈관 형체의 자동추적 알고리즘 및 분기점 추출 방법을 ICG 망막 영상에 적용하여 실험한 결과 만족할 만한 성능을 보였다.

  • PDF

Detection of Retinal Vessels of Fundus Photograph Using Hessian Algorithm (안저 영상에서 헤이지안 알고리즘을 이용한 혈관 검출)

  • Kang, Ho-Chul;Kim, Kwang-Gi;Oh, Whi-Vin;Hwang, Jeong-Min
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.8
    • /
    • pp.1082-1088
    • /
    • 2009
  • Fundus images are highly useful in evaluating patients' retinal conditions in diagnosing eye diseases. In particular, vessel regions are essential in diagnosing diabetes and hypertension. In this paper, we used top-hat filter to compensate for non-uniform background. Image contrast was enhanced by using contrast limited adaptive histogram equalization (CLAHE) method. Hessian matrix was next applied to detect vessel regions. Results indicate that our method is 1.3% more accurate than matched filter method. Our proposed method is expected to contribute to diagnosing eye diseases.

  • PDF