• Title/Summary/Keyword: 현장 관입 시험

Search Result 216, Processing Time 0.026 seconds

The Estimation of the Constrained Modulus and the Coefficient of Consolidation from the Piezocone Penetration Test Data (피에조 콘 관입시험결과에 따른 구속탄성계수, 압밀계수 산정에 관한 연구)

  • Lee, Kise;Ku, Namshil;Han, Woonwoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.4
    • /
    • pp.47-55
    • /
    • 2007
  • Using the results of the Piezocone Penetration Test (PCPT) which were executed at the Yangsan-Mulgum site, the applicability of the interpretation methods for estimating the coefficient of consolidation ($C_v$) of soft clay was evaluated. At the same time, laboratory soil tests using the total of 172 undisturbed soft clay samples from the 44 regions of the Yangsan-Mulgum site were performed to study the differency in the coefficient of consolidation ($C_v$) compared to the results of PCPT. The calculated constrained modulus ($M_{\varepsilon}$) and coefficient of consolidation ($C_v$) using the results of consolidation laboratory tests which are based upon the consolidation theory of Terzaghi were compared with the predicted constrained modulus ($M_p$) and coefficient of consolidation ($C_{v-{M_p}}$) from the PCPT. The relationship between the predicted constrained modulus ($M_p$) and the calculated constrained modulus($M_c$) were showed good correlation. The $M_p$ by the Jones & Rust method were showed mostly similar to the calculated constrained modulus ($M_c$). The relationship between the coefficient of consolidation ($C_v$) obtained from the consolidation tests and the calculated coefficient of consolidation ($C_{v-{M_p}}$) were showed a linear relationship. The results of the calculated coefficient of consolidation ($C_{v-{M_p}}$) were about 54% of the value of the coefficient of consolidation ($C_v$) obtained from the consolidation tests.

  • PDF

Hammer Energy Level of SPT in Korea (표준관입시험의 해머에너지 수준)

  • 이호준;박용원
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.117-126
    • /
    • 1996
  • In spite of many advantages such as the simplicity in test procedure, Standard Penetration Test(SPT) results contain some errors caused by the variability of test equipment, instruments and test procedures. Especially, it is inevitable that the measured SPT hammer energy is different from the theoretical value because of energy loss. In this paper, the hammer energy level is measured during the performance of the field SPT in Korea by using a ultra-sonic system and PC.program. As the results of this study, the average hammer energy ratio of the R-P hammer and the Trip hammer is calculated at 64.2%, and at 75.0% respectively. The average energy ratio of the SPT for the R-P hammer is calculated at 46% and at 54% for the Trip hammer, by applying the rod energy ratio 0.72.

  • PDF

Development of Static Rock Penetrometer for Locating Rock Stratum During Construction of Drilled Shafts (암반에 근입된 현장타설말뚝 시공시 선단부 강도확인을 위한 정적암반관입기 개발연구)

  • Nam, Moon-S.
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.9
    • /
    • pp.71-74
    • /
    • 2010
  • During construction of deep foundation in soft rock under varying soil properties, it is essential to locate the rock stratum, especially when drilling with slurry. When slurry is used for drilling, the bottom of the borehole cannot be seen, thereafter soil cuttings cannot be differentiated from soft rock cuttings. A new static rock penetrometer, known as Rock Penetrometer was developed during this study. It could be a simple mechanical device that is attached to the bottom of a Kelly bar which is used to attach drilling tools such as augers and core barrels while drilling. After its calibration in the laboratory, the performance of the static rock penetrometer was verified in the several field test sites.

Numerical Analysis of Piezocone Test using Modified Cam-Clay Model (Modified Cam-Clay Model을 이용한 피에조콘 시험의 수치해석)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.3
    • /
    • pp.89-99
    • /
    • 2001
  • In this study, the numerical analysis of piezocone penetration and dissipation tests has been conducted using the Modified Cam-Clay model, which is generally used in soil mechanics. The Modified Cam-Clay model and related mathematical equations in finite element derivation have been formulated in the Updated Lagrangian reference frame to take the large displacement and finite strain nature of piezocone penetration into consideration. The cone tip resistance, the pore water pressure, and the dissipation curve obtained from the finite element analysis have been compared and investigated with the experimental results from piezocone penetration test performed in Yangsan site. The numerical results showed good agreement with the experimental results; however, the better numerical simulation of the continuous and deep penetration needs further research.

  • PDF

A Study on Evaluation of Modulus of Horizontal Subgrade Reaction through Field Test and Numerical Analysis (현장시험과 수치해석을 통한 수평지반반력계수 산정에 관한 연구)

  • Kang, Byungyun;Park, Minchul;Lee, Sihyung;Jang, Kisoo;Koo, Jagap;Park, Kyunghan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.4
    • /
    • pp.5-15
    • /
    • 2016
  • For achieving stability and economic construction at a retaining wall construction site, quantitative parameters of soil properties with excavation steps coincides with the actual field site. The main parameters of retaining wall design such as deformation modulus and modulus of horizontal subgrade reaction are common with N value of standard penetration test. Therefore, this study is compared and analyzed about the mutual relationship which is SPT, PBT and PMT for overcoming inconsistency of the existing retaining wall design generalized. In addition, modulus of horizontal subgrade reaction and reduction factor with excavation steps are proposed through back analysis of elasto-plasticity and finite element method with actual field monitoring data. Finally, it is purpose that parameter errors are reduced for applying effective retaining wall design at a construction small and medium-sized.

A Comparative Study on Results of Static Pile Load Test of Rock Socketed Drilled Shaft and Bearing Capacity Equations (암반에 근입된 현장타설말뚝의 정재하시험결과와 지지력이론식의 비교)

  • Kim, Won-Cheul;Hwang, Young-Cheol;Hwang, Sung-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.4
    • /
    • pp.51-58
    • /
    • 2002
  • In Korea, drilled shaft are generally socketed into rock. Driven pile has environmental problems such as vibration and noise, therefore, the applications of the drilled shaft are increasing in Korea. In this paper, static load test data of the rock socketed drilled shaft at Gwangandaero and Suyeong3hogyo are analyzed. The bearing capacities from field test data and theoretical formula are compared and analyzed. From this study, design approaches for drilled shafts in Korea are examined and several suggestions are proposed.

  • PDF

An Experimental Study on the Evaluation of Smear Effect Considering In-situ Conditions (현장여건을 고려한 스미어 영향 평가에 관한 실험적 연구)

  • Park, Yeong-Mog
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.8
    • /
    • pp.85-94
    • /
    • 2012
  • Evaluation of the smear effect caused by mandrel penetration into soft ground for a vertical drain installation is very important to predict the consolidation time of soft ground improvement. 30 kinds of laboratory model tests considering in situ conditions were conducted to investigate the formation of a smear zone and the decrease of coefficient of permeability in the disturbed zone. Three types(C(clay):M(silt)=1:1, 0.5:0.5, and 0:1) of reconstituted samples were used for 3 dimensional smear zone test. An experimental study was performed focusing on length of mandrel penetration, mandrel shape and size, earth pressure, and ground condition(unit weight and grain size distributions). Laboratory test results show that the length of mandrel penetration is the most critical factor for the formation of smear zone. As a result, the ratio between diameter of the smear zone($d_s$) and that of mandrel($d_m$) at field using long mandrel becomes larger than conventional $d_s/d_m$. The ratio between $d_s$ and $d_m$ ranges from 1.89 and 2.48 with the sample at C:M=1:0. It was also found that the $d_s/d_m$ value with the round shape of the mandrel is smaller than that of diamond one. The value of $d_s/d_m$ decreased with larger mandrel size, lower unit weight, and higher earth pressure. However, higher silt content led to increase of $d_s/d_m$. The ratio between coefficient of horizontal permeability in the smear zone($k_{hs}$) and that of undisturbed zone($k_{ho}$) ranged from 0.70 to 0.85. The test results imply that factors and values affecting $k_{hs}/k_{ho}$ show similar tendency with $d_s/d_m$.

A Reliability Study on Estimating Shear Strength of Marine Soil using CPT (Cone 관입시험을 이용한 해양토질의 전단강도 산정에 대한 신뢰도 연구)

  • 이인모;이명재
    • Geotechnical Engineering
    • /
    • v.3 no.2
    • /
    • pp.17-28
    • /
    • 1987
  • Reliability of the cone penetration test (CPT) for estimating shear strength of marine soils is investigated in this paper. For sands, the uncertainty about the angle of internal friction is analyzed. It includes the spatial variation of the soil and the model error in the equation used for interpretation. The most serious uncertainty encountered was the error in the interpretative models. Different methods of interpretation gave quite different values. Subjective opinion was introduced to combine all the interpretative models in a systematic manner. For clays, the undrained Shear Strength from the CPT results is usually =derived by empirical correlations between cone resistance and untrained shear strength from laboratory tests or field vane tests, expressed in terms of cone factor and function of overburden pressure. The uncertainty of the undrained shear strength is caused by data scatter of the cone factor in the correlation, model error of the cone factor, effect of anisotropy, and spatial variability of cone resistance. Among these uncertainties, the most serious one was the data scatter of the cone factor in the .correlation. Between the laboratory test and the field vane test used for correlation, the field vane test was more reliable.

  • PDF

A Study on the Field Application of a Small Dynamic Cone Penetration Tester Using Hammer Automatic Strike and Penetration Measurement (해머 타격과 관입량 측정이 자동화된 소형 동적콘관입시험기의 현장 적용성 연구)

  • Hwiyoung Chae ;Soondal Kwon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.12
    • /
    • pp.5-11
    • /
    • 2023
  • Economic damage is occurring due to landslides and debris flows that occur when the ground artificially created for roads or photovoltaic power generation facilities is weakened by rainfall such as torrential rain. In order to understand the stability of the artificially created ground, it is very important to check the ground information such as the compositional state and mechanical characteristics of the stratum. However, since most of the investigation sites are steep slopes or there are no access roads, it is not easy to enter the drilling equipment commonly used to check ground information and perform standard penetration tests. In this study, a dynamic cone penetration test (DCP) device using a miniaturized auger drilling equipment and an automatic drop device was developed to check the cone resistance value and the dynamic cone penetration test value and analyze the correlation with the standard penetration test value to confirm its applicability at the mountain solar power generation site. As a result, the cone resistance value is qd = 0.46 N and the dynamic cone penetration test value is Nd = 1.58 N, confirming a value similar to the results of existing researchers to secure its reliability.

TDR 함수량계의 성토 다짐관리에의 활용

  • Kim, Gyu-Seon;Gwon, Hyeong-Seok
    • Geotechnical Engineering
    • /
    • v.28 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • TDR 함수량계는 전자기파를 이용하여 흙의 밀도와 함수비를 비파괴적으로 신속하게 평가하는 유망한 기술이다. TDR 시험법은 10~20cm 길이의 2~3개의 탐침을 지중에 관입시킨 후 전자기파의 이동시간을 측정하여 유전상수($K_a$)를 산정한다. 제안식을 이용하여 유전상수로부터 체적함수비(${\theta}$)의 산정이 가능하므로, 이 시험법은 흙의 함수비를 측정할 수 있는 비파괴시험 장치로 개발되어 활용되고 있다. 또한, 흙의 종류에 따른 보정상수가 파악되어 있는 경우에는 현장 밀도와 현장 함수비를 동시에 평가할 수 있으므로, TDR 함수량계를 이용하여 성토지만비나 노상토에 대한 신속하고 간편한 다짐관리가 기능하다.

  • PDF