• Title/Summary/Keyword: 현장열화

Search Result 212, Processing Time 0.028 seconds

Development of Longtime Reliability Assessment Method of Polymer Housed Distribution Surge Arresters using Accelerated Aging Test (가속열화시험을 이용한 배전용 폴리머피뢰기의 장기신뢰성 평가기법 개발)

  • Kim, Ju-Yong;Song, Il-Keun;Moon, Jae-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.141-150
    • /
    • 2006
  • In this study we developed accelerated aging test cycle and equipment which can simulate domestic weather condition. And we proposed long term reliability assessment method for polymer housed distribution surge arresters. We carried out electrical and chemical analysis of the arresters which are used for accelerated aging test and outdoor exposure test. Through the analysis we verified the capability of the proposed method and we presented characteristic data for maintenance of domestic arresters.

Degradation Evaluation of High Pressure Reactor Vessel in field Using Electrical Resistivity Method (전기비저항법을 이용한 고압반응기 열화도 현장평가)

  • Park, Jong-Seo;Baek, Un-Bong;Nahm, Seung-Hoon;Han, Sang-In
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.377-383
    • /
    • 2005
  • Because explosive fluid is used at high temperature or under high pressure in petrochemistry and refined oil equipment, the interest about safety of equipments is intensive. Specially, the safety of high pressure reactor vessel is required among them. The material selected in this study is 2.25Cr-1Mo steel that is widely used for high pressure reactor vessel material of petrochemical plant. Eight kinds of artificially aged specimens were prepared by differing from aging periods under three different temperatures. The material was iso-thermally heat treated at higher temperatures than $391^{\circ}C$ that is the operating temperature of high pressure reactor vessel. Vickers hardness properties and electrical resistivity properties about artificially aged material as well as un-aged material were measured, and master curves were made out from the correlation with larson-Miller parameter. And electrical resistivity properties as well as Victors hardness properties measured at high pressure reactor vessel of the field were compared with master curves made out in a laboratory. Degradation evaluation possibility in the field of high pressure reactor vessel by using electrical resistivity method was examined. Electrical resistivity property measured in the field is similar with that of artificially aged material in similar aging level.

Personalized Cooling Management System with Thermal Imaging Camera (열화상 카메라를 적용한 개인 맞춤형 냉각관리 시스템)

  • Lee, Young-Ji;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.782-785
    • /
    • 2021
  • In this paper, we propose a personalized cooling management system with thermal imaging camera. The proposed equipment uses a thermal imaging camera to control the amount of cold air and the system according to the difference between the user's skin temperature before and after the procedure. When the skin temperature is abnormally low, the cold air supply is cut off to prevent the possibility of a safety accident. It is economical by replacing the skin temperature sensor with a thermal imaging camera temperature measurement, and it can be visualized because the temperature can be checked with the thermal image. In addition, the proposed equipment improves the sensitivity of the sensor that measures the distance to the skin by calculating the focal length by using a dual laser pointer for the safety of a personalized cooling management system to which a thermal imaging camera is applied. In order to evaluate the performance of the proposed equipment, it was tested in an externally accredited testing institute. The first measured temperature range was -100℃~-160℃, indicating a wider temperature range than -150~-160℃(cryo generation/USA), which is the highest level currently used in the field. In addition, the error was measured to be ±3.2%~±3.5%, which showed better results than ±5%(CRYOTOP/China), which is the highest level currently used in the field. The second measured distance accuracy was measured as below ±4.0%, which was superior to ±5%(CRYOTOP/China), which is the highest level currently used in the field. Third, the nitrogen consumption was confirmed to be less than 0.15 L/min at the maximum, which was superior to the highest level of 6 L/min(POLAR BEAR/USA) currently used in the field. Therefore, it was determined that the performance of the personalized cooling management system applied with the thermal imaging camera proposed in this paper was excellent.

On Diagnosis Measurement under Dynamic Loading of Ball Bearing using Numerical Thermal Analysis and Infrared Thermography (전산 열해석 및 적외선 열화상을 이용한 볼베어링의 동적 하중에 따른 진단 계측에 관한 연구)

  • Hong, Dong-Pyo;Kim, Ho-Jong;Kim, Won-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • With the modern machinery towards the direction of high-speed development, the thermal issues of mechanical transmission system and its components is increasingly important. Ball bearing is one of the main parts in rotating machinery system, and is a more easily damaged part. In this paper, bearing thermal fault detection is investigated in details Using infrared thermal imaging technology to the operation state of the ball bearing, a preliminary thermal analysis, and the use of numerical simulation technology by finite element method(FEM) under thermal conditions of the bearing temperature field analysis, initially identified through these two technical analysis, bearing a temperature distribution in the normal state and failure state. It also shows the reliability of the infrared thermal imaging technology. with valuable suggestions for the future bearing fault detection.

Measuring and Evaluating of Aging of Thyristor for High Capacity Motor Driving (대용량 전동기 구동용 Thyristor 소자의 열화 측정 및 평가)

  • Oh, Dong-Hwan;Lee, J.H.;Lee, S.H.;Kim, K.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1957-1960
    • /
    • 1997
  • 일반적으로, Thyristor와 같은 반도체 소자는 수명이 반영구적이라고 알려져 왔으나, 실제로는 사용 시간이 지남에 따라 열화 과정을 가지는 것으로 보고되고 있다. 이는 소자 제조 공정상의 결함이나 가공 불량, 소자 접합면에 존재하는 물리적 불균질성 등이 원인이 되는데 이들 원인으로 인해 반도체 소자내에 취약부위가 존재하게 된다. Thyristor 소자 응용 시스템에 있어서, 운용 중 발생되는 전기적 물리적 스트레스는 Thyristor 소자내의 취약부위에 집중되는데, 시간이 지남에 따라 취약부위가 확산되고 열화가 가속되어 갑작스런 소자 파손으로 이어지게 된다. 본 논문에서는 Thyristor 소자의 열화 과정을 이론적인 측면에서 해석하고, 실제 산업현장에서의 Thyristor 열화 발생 사례를 중심으로 대용량 Thyristor의 열화 평가방법에 대하여 고찰한다.

  • PDF

Object and Heat Detection by Isothermal Images (열화상 등온선 기반 객체 구분과 온도 인식에 관한 연구)

  • Lee, Jinseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.389-392
    • /
    • 2010
  • 기존에 없던 열화상 카메라의 기능에서 온도가 일정 수준 이상인 지점을 여러 지점 표시하는 알고리즘을 추가하였다. 또한 산업 현장뿐만 아니라 이번에 발생한 신종 플루도 감지하기 위해서 열을 통해 사람을 구분하는 방법을 추가하였다.

A Study on Electrochemical Anodic Polarization Behavior for Material Degradation Evaluation of High Temperature Structural Components (고온설비부재의 재질열화도 평가를 위한 전기화학적 양극분극거동에 관한 연구)

  • Yu, Hyo-Seon;Kim, Yeon-Jik;Jeong, Se-Hui
    • Korean Journal of Materials Research
    • /
    • v.7 no.9
    • /
    • pp.717-722
    • /
    • 1997
  • 노후화된 고온설비의 안정성 및 효율적인 운전조건을 확보하고, 고온부재의 취성파괴 방지를 위해서는 재질열화의 정량적 평가는 매우 중요하다. 그러나 현장실기에서 기계적 성질의 평가를 위한 대량의 시험편 채취는 거의 불가능하다. 따라서, 실기부재의 강도에 영향을 미치지 않는 범위에서 플랜트 구조물의 재질열화 평가를 비파괴적으로 검출 평가할 수 있는 새로운 시험방법들의 개발이 요구된다. 본 연구에서는 화력설비 부재의 다양한 탄소강을 대상으로 재질열화도 평가를 위한 전기화학적 양극분극시험법의 적용 가능성을 조사하였다. 또한 양극분극시험에 의한 재질열화평가 유효성을 조사하기 위해 전기화학적 시험결과를 입계부식시험결과와 비교.검토해 보았다.

  • PDF

Design of System Diagnosis Insulation Degradation of Motor by using Electromagnetic Wave(1) (전자파를 이용한 전동기 절연열화 진단시스템의 설계(1))

  • Kim, Yi-Gon;Yoo, Kweon-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2531-2534
    • /
    • 2000
  • 본 연구는 전동기의 부분방전에 의해 발생되는 전자파를 측정하여 전동기의 열화상태를 진단할 수 있는 전동기 절연열화진단시스템을 설계하는 방법을 제안하고자 한다. 따라서 부분방전에 의한 전자파를 측정하는 시스템을 구성하고, 측정된 데이터를 분석하여 정량화된 특징 데이터를 추출하고 생성된 데이터를 이용한 뉴로-퍼지 진단모델설계 방법을 제시한다. 그리고 제안된 방법에 의해 설계된 진단모델을 실측데이터를 통해 진단하여 그 타당성을 입증하고자 한다. 1단계 연구로, 본 연구에서는 현장 전동기의 전자파를 On-Line으로 계측하는 시스템을 구성하여 전동기의 절연체내에서 발생하는 부분방전에 의한 전자파를 계측하여 데이터로부터 전동기의 절연열화상태를 해석하여 절연 열화와의 관계를 분석하였다.

  • PDF

Correlation Filter Based Thermal Object Tracking Using Objectness Feature (객체성 특징을 활용한 Correlation Filter 기반 열화상 객체 추적 기법)

  • Jung, Hyeonseok;Kim, Wonjun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.06a
    • /
    • pp.89-91
    • /
    • 2019
  • 객체 추적 기술은 컴퓨터 비전 분야에서 활발하게 연구되고 있는 분야로, 인간-컴퓨터 상호작용(HCI)이나 로보틱스, 그리고 자율주행 자동차와 같은 곳에 유용하게 사용될 수 있다. 그중에서도 열화상 객체 추적 기술은 빛이 전혀 없는 어두운 밤에도 적용 가능하기 때문에, 감시 시스템이나 사고 현장의 구조 상황, 또는 군사적 응용에 더욱 유용하다. 그러나 일반적으로 열화상 영상은 컬러 영상보다 해상도가 낮고, 객체의 경계가 흐릿하며, 텍스쳐가 거의 없다는 점 때문에 기존 추적 방법들의 성능 저하의 원인이 된다. 이에 본 논문은 기존 Correlation Filter 기반 추적기에 객체성 특징을 함께 이용하여, 열화상 영상에서의 객체 추적 성능을 향상 시키는 방법을 제안하였다. 또한 실험을 통해 기존 방법보다 열화상 영상에서의 객체 추적 성능이 향상된 것을 보였다.

  • PDF