• Title/Summary/Keyword: 현장성능

Search Result 2,263, Processing Time 0.031 seconds

Performance Evaluation of Search Robot Prototypes for Special Disaster Areas (특수재난지역 정찰로봇 시제품의 성능평가연구)

  • Kwark, Jihyun
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.109-118
    • /
    • 2015
  • Recently, three kinds of search robot prototypes were developed to assume the role of fire fighters for search and rescue missions in special disaster areas with high heat, smoke, toxic gases, or radioactivity. To accomplish search missions, these robots should be able to endure heat, overcome various obstacles, suppress fires, and see through dense smoke. This study investigated the heat resistance, practicality, and fire fighting capacity of these robots. The results show that the small and middle-sized robots were resistant to surrounding temperatures of $100{\sim}200^{\circ}C$, and the fire-fighter-riding robot could endure up to $500^{\circ}C$ for half an hour. The fire-fighter-riding robot showed excellent extinguishing performance on an A-10 class fire model, which was extinguished within 3 min. The robots also showed various capacities for overcoming obstacles and are expected to play an active role in various special disaster areas.

Comparison of the Characteristics of Mix Design and the Performance of Shotcrete Used in Expressway Tunnel Construction Sites (고속도로 터널 숏크리트 현장배합 특성 및 성능 비교 연구)

  • Lee, Sangdon
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.532-541
    • /
    • 2019
  • Even though shotcrete is a main support for securing the stability of tunnel, the performance of shotcrete is not properly checked due to various difficulties arisen from the characteristics of materials themselves which constitute shotcrete, such as steel fibers and accelerators, and the on-site quality control. In this study, the actual conditions of shotcrete applied to expressway tunnel construction sites were tried to find out, and then some improvement was tried to derive. For this purpose, the characteristics of steel fibers and accelerators supplied to the expressway construction sites were investigated. Also, shotcrete specimens were prepared at the tunnel sites and performance tests were carried out. For steel fiber, domestic production states were investigated, and carbon content and tensile strength were measured using the steel fibers collected in the construction sites. For three types of accelerators such as aluminate, cement mineral and alkali-free, basic properties and total amount of alkali contents were analyzed. Shotcrete specimens were prepared using on-site shotcrete machine with regard to mix designs and types of accelerators. Using these specimens, uniaxial compression tests and flexural tests were performed. As the results, compressive strength, flexural strength, flexural toughness, and etc. were compared with types of acclerators and mix designs.

An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump (소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.85-91
    • /
    • 2012
  • This paper analyzed firefighting officers' use situations such as the use time, maximum working pressure, hose diameter, etc. of fire pumps at fire sites and carried out various performance tests by pressures, hose diameters and quantities of fire pumps based on its results because the waterproof performance criterion for a fire pump installed in a fire engine is different from the operation situations at the site and is not clearly prescribed. As a result of site survey, the site uses a higher pressure than the standard water discharge pressure (0.85 MPa) or the high-pressure water discharge pressure (1.4 MPa) prescribed by the approval Standard of the fire pump performance on fire truck. In addition, as a result of pump performance test, the discharged water flow rate, water discharge pressure, etc. was measured to be very different from the currently prescribed the approval standard depending on the hose diameter and firefighting nozzle, so the result of this study proposes a new standard.

A Study on the On-site Flame Resistant Treatment in Domestic (국내 현장방염 시공의 실태분석 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.33-38
    • /
    • 2011
  • This study is a research for analysis the states of flame resistant treatment and its system which important in fire prevention by ignition delay of early stage of fire. Some problems arose in the flame resistant treatment site were analysed through the meeting with fire officer and businessman related with flame resistant treatment, and visiting the flame resistant treatment places. From the meeting, visiting and reviewing the code system we find the following problems. First one is a problem of excessive competition with many company in small market of flame resistant treatment and to reduce the cost, the businessman who have no professional technic do not work along the specification. Second one is the inspection system which do not inspect on site but inspect by sampling the flame resistant treated materials submitted by businessman. And there are some problems arose about the reliability and consistency of flame resistant performance of the sample and the treated site. To solve the above problems, we suggest some countermeasure.

A Study on Institutional Improvement to Activate Field Application of Smart Construction Safety Technology (스마트 건설안전 기술의 현장 적용 활성화를 위한 제도 개선 연구)

  • Jeong, Deokhwa;Kim, Sehoon;Im, Seokbeen
    • Journal of the Korea Institute of Construction Safety
    • /
    • v.4 no.1
    • /
    • pp.16-21
    • /
    • 2021
  • Recently, as part of an effort to reduce the high accident rate in the construction industry, the smart construction safety technology is being introduced, and some institutional improvements are being made simultaneously. This study has been carried out to identify the effectiveness of such an improved institution and to draw additional opinions for improvement to spread the field application of smart safety technology. A survey was conducted for participants in the construction industry, and awareness of the improved institution and additional requirements for spreading smart safety technology in the construction site were investigated. As a result of the investigation, high interest in the field application of smart construction safety technology has been confirmed, and some issues such as safety management costs and duplication of on-site safety paperwork have been raised. The opinions derived through this study will be used as baseline data for future institutional improvements for the introduction and diffusion of smart construction safety technology in the construction site.

Constructional Verification Evaluation for Securing the Field Quality of Composite Membrane Waterproofing Material (멤브레인 복합 방수재의 현장품질 안정성 확보를 위한 시공성 실증 평가 연구)

  • Kim, Meong-Ji;Lee, Sang-Wook;Kim, Soo-Yeon;Oh, Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.1
    • /
    • pp.87-95
    • /
    • 2021
  • In this study, seven companies(A~G) designated as new construction technology selected and evaluated KS F 2622: Method of test for performance evaluation of membrane roofing systems that are similar to field application conditions. As a result of the test, it was confirmed that although all test specimens exceeded KS standards in the basic physical, it was difficult to obtain field quality performance in weak areas such as joints and vertical parts of the adhesive coating method in water-tightness, sagging resistance, swelling resistance tests except for fatigue(crack behavior) tests.

An Experimental Study on the Performance Evaluation of Repair Method of RC Structure Using Fire Resistance Engineered Cementitious Composites(FR-ECC) (고인성 내화·보수 모르타르를 활용한 RC구조물 보수공법의 성능평가에 관한 실험적 연구)

  • Kim, Jeong-Hee;Kim, Jae-Whan;Park, Sun-Gyu;Kwon, Young-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.6 s.58
    • /
    • pp.88-96
    • /
    • 2009
  • In this Study, FR-ECC(Fire Resistance Engineered Cementitious Composites) in which at same time it can improve the endurance and fire-resistance efficiency of a Structure was developed, and the experimental study such as thermal characteristic, Fire-resistance efficiency, and etc was performed for using FR-ECC as the repair materials for building and civil Structure. Moreover, it was evaluated about the field applicability of FR-ECC. As a result, FR-ECC is superior to the existence fire resistance repair mortar in strength and durability property. Also, FR-ECC was exposed to have the characteristic of being excellent than existence fire resistance mortar in the field applicability.

Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile (병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가)

  • Park, Sangwoo;Kim, Byeongyeon;Sung, Chihun;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.361-375
    • /
    • 2015
  • An energy pile is one of the novel ground heat exchangers (GHEX's) that is a economical alternative to the conventional closed-loop vertical GHEX. The combined system of both a structural foundation and a GHEX contains a heat exchange pipe inside the pile foundation and allows a working fluid circulating through the pipe, inducing heat exchange with the ground formation. In this paper, a group of energy piles equipped with parallel U-type (5, 8 and 10 pairs) heat exchange pipes was constructed in a test-bed by fabricating in large-diameter cast-in-place concrete piles. In addition, a closed-loop vertical GHEX with 30m depth was constructed nearby to conduct in-situ thermal response tests (TRTs) and to compare with the thermal performance of the cast-in-place energy piles. A series of thermal performance tests was carried out with application of an artificial cooling and heating load to evaluate the heat exchange rate of energy piles. The applicability of cast-in-place energy piles was evaluated by comparing the relative heat exchange efficiency and heat exchange rate with preceding studies. Finally, it is concluded that the cast-in-place energy piles constructed in the test-bed demonstrate effective and stable thermal performance compared with the other types of GHEX.