• Title/Summary/Keyword: 현열 및 잠열

Search Result 39, Processing Time 0.029 seconds

Atmospheric and Oceanic Factors Affecting the Air-Sea Thermal Interactions in the East Sea (Japan Sea) (東海海面 熱交換에 影響을 미치는 大氣 및 海洋的 要因)

  • Kang, Yong Q
    • 한국해양학회지
    • /
    • v.19 no.2
    • /
    • pp.163-171
    • /
    • 1984
  • The atmospheric and oceanic influences on the air-sea thermal interaction in the East Sea (Japan Sea) are studied by means of an analytic model which is based on the heat budget of the ocean. By means of the model, the model, the annual variations of heat fluxes and air temperatures in the East Sea are analytically simulated. The model shows that the back radiation, the latent heat and the sensible heat increase with the warn water advection. The latent heat increases with the sea surface temperature (SST) but the back radiation and the sensible heat dcrease as the SST increases. In the East Sea, an increase of mean SST by 1.0$^{\circ}C$ yields an increase of mean air temperature by 1.2$^{\circ}C$. The heat storage in the ocean plays an important role in the annual variations of heat flux across the sea surface.

  • PDF

Heat Storage Material by Using Phase Change Materials to Control Buildings Thermal Environment Characteristics (건축물 열환경 특성제어를 위한 상변화 축열재)

  • Yun, Huy-Kwan;Han, Seong-Kuk;Shim, Myeong-Jin;Ahn, Dae-Hyun;Lee, Woong-Mok;Park, Jong-Soon;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.522-526
    • /
    • 2010
  • Heat storage application techniques can be categorized into the sensible heat storage and the latent heat storage according to the method of heat storage. Heat storage is the way of saving remaining heat when heating and cooling loads are light, and then using it when the heating and cooling loads are heavy. Latent heat storage is defined as the method of saving heat by using substances which have high potential heat when phase change is in the range of a certain temperature and when heat storage space is small, compared to those of sensible heat storage and it is possible that absorption and emission of heat at a certain temperature. This study is conducted to save energy when either air-conditioning or heating is operated in a building. We have tried to find out the essential properties of matter and the optimum mixing rate about cement and gypsum for building materials, which have been widely used for proper phase change materials (PCM), when thermal environment property is applied. So we obtained the result of the cooling delay effect about 19% with heat storage mortar containing 3 wt% of PCM.

A study on Rotor Development for Air-to-Air Heat Exchanger (전열교환기 성능향상 및 로터 국산화 개발에 관한 연구)

  • Seo, Seok-Jeong;Park, Ban-Uk
    • 한국기계연구소 소보
    • /
    • s.16
    • /
    • pp.17-28
    • /
    • 1986
  • 전열교환기는 최근 대형건물 및 생산공장 등의 에너지 다소비 장소의 공기조화설비의 에너지 절감기기로서 크게 각광 받고 있다. 그 중에서도 특히 알루미늄 박판에 실리카-겔 분말을 코팅한 Honey comb형 로터는 현열 및 잠열 즉 전열을 흡수할 수 있어 폐에너지 회수용 전열교환기의 전열소자로서 점차 이용되고 있다. 그러나 국내에서는 현재까지 전열교환기의 핵심부품인 상기 로터를 전량 수입에 의존하여 왔다. 본 연구에서는 백륜공업(주)와 공동출연으로 실리카-겔 분말 코팅된 알루미늄 소재 박판만 수입하여 성형공정 기술을 개선, 향상시켜 국산로터의 시제품을 제작하고 그 성능을 시험하여 수입로터와 비교, 평가하였다. 연구결과, 국산개발 알루미늄 로터 시제품의 전열효율이 수입로터 보다 급배기 조건에 따라 1~5%정도 향상되었다. 또한 알루미늄 로터의 최적운전조건(11-13 r.p.m) 및 급배기 공기량비에 대한 적정조건도 연구결과로 얻어졌다.

  • PDF

A Study on Rotor Development for Air-to-Air Heat Exchanger (전열교환기 성능향상 및 로타 국산화 개발에 관한 연구)

  • Seo S. C.;Park B. O.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.3
    • /
    • pp.226-233
    • /
    • 1986
  • 전열교환기는 최근 대형건물 및 생산공장 등의 에너지 다소비 장소의 공기조화 설비의 에너지 절감 기기로서 크게 각광 받고 있다. 그 중에서도 특히 알루미늄 박판에 실리카-겔 분말을 코팅한 허니컴형 로타는 현열 및 잠열 즉 전열을 흡수할 수 있어 폐 에너지 회수용 전열교환기의 전열소자로서 점차 이용되고 있다. 그러나 국내에서는 현재까지 전열교환기의 핵심부품인 상기 로타를 전량 수입에 의존하여 왔다. 본 연구에서는 백륜공업(주)와 공동출연으로 실리카-겔 분말 코팅된 알루미늄 소재 박판만 수입하여 성형공정 기술을 개선, 향상시켜 국산로타의 시제품을 제작하고 그 성능을 시험하여 수입로타와 비교, 평가하였다. 연구결과 국산개발 알루미늄 로타 시제품의 전열효율이 수입로타보다 급배기 조건에 따라 $1\~5\%$정도 향상되었다. 또한 알루미늄 로타의 최적운전조건$(11\~13\;r.p.m)$ 및 급배기 공기량비에 대한 적정조건도 연구결과로 얻어졌다.

  • PDF

Study on the Latent Heat Characteristics of the Organic Compound, $C_{28}H_{58}$ and the Inorganic Compound, $CH_3COONa{\cdot}3H_2O$ (유기잠열재, $C_{28}H_{58}$과 무기잠열재, $CH_3COONa{\cdot}3H_2O$의 잠열특성연구)

  • Song, Hyun-Kap;Ryou, Young-Sun
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.53-61
    • /
    • 1991
  • In this research, Octacosane($C_{28}H_{58}$) and Sodium Acetate Trihydrate($CH_3COONa{\cdot}3H_2O$) were selected as latent heat storage materials to store off-peak electricity or waste heat of an industrial plant. Experimental analyses were performed in terms of the variation of phase change temperature and latent heat, phase change stability for the long term utilization. The results were as follows. 1. The phase change temperatures of industrial grade Octacosane and Sodium Acetate Trihydrate were $60.7^{\circ}C$ and $57.4^{\circ}C$, the latent heat were 60.6kcal/kg and 51.1kcal/kg respectively. 2. The latent heat quantity of Octacosane was decreased with the increasing number of phase change cycles. It decreased from 60.6kcal/kg to 47.2kcal/kg upto 200 cycles and then no variation was observed after 200 cycles. 3. To prevent the supercooling of Sodium Acetate Trihydrate, the nucleating agent, Sodium Pyrophosphate Decahydrate of 3 wt% was added, and then the supercooling temperature (Tm-Tsc) was decreased from $25.7^{\circ}C$ to $1^{\circ}C$. The phase separation was disappeared by the addition of CMC-Na of 3 wt% as a thickener. It was found that the optimal quantity of nucleating agent and thickener was 4wt% considering the stability of SAT as a latent heat storage material. 4. The phase change temperature of Sodium Acetate Trihydrate($CH_3COONa{\cdot}3H_2O$) was adjusted from 57.4 to $46.2^{\circ}C$ by the addition of UREA. And then the latent heat quantity was decreased from 51.1 to 38.3kcal/kg. 5. When the heat storage capacities between the sensible and latent heat storage materials were analyzed and compared in heating process from 30 to $90^{\circ}C$, the heat storage capacity of Octacosane was 2.45 times larger than water and 12.5 times than granite at $60.7^{\circ}C$, and the heat storage capacity of Sodium Acetate Trihydrate was 2.53 times larger than water and 12.91 times than granite at $57.4^{\circ}C$.

  • PDF

Prediction of future hydrologic variables of Asia using RCP scenario and global hydrology model (RCP 시나리오 및 전지구 수문 모형을 활용한 아시아 미래 수문인자 예측)

  • Kim, Dawun;Kim, Daeun;Kang, Seok-koo;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.6
    • /
    • pp.551-563
    • /
    • 2016
  • According to the 4th and 5th assessment of the Intergovernmental Panel on Climate Change (IPCC), global climate has been rapidly changing because of the human activities since Industrial Revolution. The perceived changes were appeared strongly in temperature and concentration of carbon dioxide ($CO_2$). Global average temperature has increased about $0.74^{\circ}C$ over last 100 years (IPCC, 2007) and concentration of $CO_2$ is unprecedented in at least the last 800,000 years (IPCC, 2014). These phenomena influence precipitation, evapotranspiration and soil moisture which have an important role in hydrology, and that is the reason why there is a necessity to study climate change. In this study, Asia region was selected to simulate primary energy index from 1951 to 2100. To predict future climate change effect, Common Land Model (CLM) which is used for various fields across the world was employed. The forcing data was Representative Concentration Pathway (RCP) data which is the newest greenhouse gas emission scenario published in IPCC 5th assessment. Validation of net radiation ($R_n$), sensible heat flux (H), latent heat flux (LE) for historical period was performed with 5 flux tower site-data in the region of AsiaFlux and the monthly trends of simulation results were almost equaled to observation data. The simulation results for 2006-2100 showed almost stable net radiation, slightly decreasing sensible heat flux and quite increasing latent heat flux. Especially the uptrend for RCP 8.5 has been about doubled compared to RCP 4.5 and since late 2060s, variations of net radiation and sensible heat flux would be significantly risen becoming an extreme climate condition. In a follow-up study, a simulation for energy index and hydrological index under the detailed condition will be conducted with various scenario established from this study.

Soil Surface Energy Balance and Soil Temperature in Potato Field Mulched with Recycled-Paper and Black Plastic Film (감자밭의 재생종이 및 흑색 플라스틱 필름 멀칭에 따른 지표면 에너지 수지와 토양온도의 변화)

  • 최일선;이변우
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.3
    • /
    • pp.229-235
    • /
    • 2001
  • The thermal and photometric properties of mulching materials modify the radiation and energy balance on the mulched soil surface and thereby change the soil temperature. The soil surface energy balances and soil temperatures under the mulching treatments of non-mulched control, recycled paper (RPM), and black polyethylene film (BPFM) were compared before and after the establishment of potato canopy. On August 30 in 1998 when potato was not emerged yet and solar radiation was 17.9 MJ $m^{-2}$${day}^{-1}$ , the net radiation of the soil surface was estimated as 10.(1, 2. 4, and 1.3 MJ $m^{-2}$${day}^{-1}$ under the control, BPFM, and RPM, respectively. The sensible and latent heat loss from the soil surface was 9.65 MJ $m^{-2}$${day}^{-1}$ in the control, most of the net radiation being lost through evaporation and convection, whereas it amounted only to 1.39 MJ $m^{-2}$${day}^{-1}$ in BPFM and 1.36 MJ $m^{-2}$${day}^{-1}$ in RPM. Therefore, the soil heat fluxes were 0.36 1.02, and 0.06 MJ m$^{-2}$ day$^{-1}$ under the control, BPFM and RPM, respectively. On September 27 when potato canopy was fully developed, the soil surface net radiation in the control was sharply decreased as compared to that of Aug. 30, whereas the net radiation of the mulched soil surfaces showed little changes. The soil heat flux was -0.01, 0.95, and 0.12 MJ $m^{-2}$${day}^{-1}$ at the soil surface under the control, BPFM and RPM, respectively. As the mulching treatments brought about such alteration of energy partitioning into the soil, the highest soil temperature was recorded in BPFM and the lowest in RMP without regard to potato canopy development. However, the soil temperature differences among the treatments become smaller when potato canopy were fully developed.

  • PDF

Heat Transfer Analysis of a Coil-Typed LPG Vaporizer with an Electrically Heating Water Bath (전열온수식 LPG 기화기의 열전달 해석)

  • Choi, Sung-Joon;Kwon, Jeong-Rock;Kim, Kwang-Seok;Kim, Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.19-25
    • /
    • 2007
  • The heat transfer phenomena in a coil-typed LPG vaporizer with a hot water bath employed an electrical heating system were experimentally analyzed. The heat energy is initially used to sensible heat region to heat LPG and then is done to latent heat region to vaporize LPG and to heat up the vaporized gas. A two-phase flow region could be found from periodic temperature fluctuations, and only sensible heat effect was found after passing through the region. The overall heat capacity was defined as multiplying the overall heat transfer coefficient by the heat transfer area and we found a correlation employing the heating water temperature and LPG flow rate. The results of this work can effectively be applied for the design of field scale LPG vaporizers in the near future because they can predict the features of heat transfer on a kind of coil type LPG vaporizer.

  • PDF

Development and validation of daily evapotranspiration based on COMS satellite and surface energy budget equation (천리안 위성 자료와 지표 에너지 수지식을 이용한 위성 일 증발산량 알고리즘 개발 및 검증)

  • Park, Na-Yeon;Kim, Youngmi;Shin, Jinho;Lyu, Sang Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.10-14
    • /
    • 2016
  • 육상의 증발산량(evapotranspiration, ET)은 대기 중 수증기의 상변화를 통해 대기와 지표 사이의 물과 에너지 순환에 영향을 미치며, 강수량, 유출량과 함께 수자원에 영향을 미치는 주요 인자이다. 강수량과 유출량은 직접 관측이 가능한 반면, 증발산량은 숨어있는 잠열로서 관측하기 어렵다. 플럭스 타워나 라이지메타(Lysimeter) 등을 이용하여 증발산량을 직접 관측하고 있으나 이들 지상관측은 일부 지점(point)에서 제한적으로 이루어지고 있으며, 관측 지점의 수를 확대하게되면 관측 기기의 유지 보수 등의 많은 시간과 비용이 든다는 한계가 있다. 이러한 지상관측의 한계를 극복하고 넓은 영역의 증발산량 변화를 관측하기 위해 위성을 이용한 증발산량을 추정하는 연구가 활발히 진행되고 있다. 기상청 국가기상위성센터(National Meteorological Satellite Center, NMSC)에서는 우리나라 최초의 정지 기상 위성인 천리안 위성(Communication, Ocean and Meteorological Satellite, COMS) 자료를 지표 에너지 수지식(Surface Energy Budget Equation)에 적용하여 동아시아 지역의 지면과 식생 특성을 반영한 '일(daily) 증발산량 산출 알고리즘'을 개발하였다. 현열을 계산하기 위해 다양한 입력 변수가 사용되어지고 계산 과정이 복잡하기 때문에, 본 연구에서는 '반 경험적인 계수인 B 계수 모델'을 사용하여 현열 산출 기법을 단순화하였다. 본 알고리즘을 이용하여 2011년 4월부터 현재까지 동아시아(위도 $20{\sim}50^{\circ}N$, 경도 $100{\sim}145^{\circ}E$)의 해상도 1km의 일 증발산량을 산출하였고, 위성 증발산량의 검증을 위해 지면 특성이 다른 청미천(농경지), 설마천(혼효림) 지역의 플럭스 타워 증발산량 자료(유량조사사업단 제공)와 비교 분석하였다. 2011년 4월부터 2014년 12월까지 청미천 지역에서의 플럭스 타워 관측과 비교한 결과, 총 665개 자료에 대하여 RMSE는 2.82 mm/day, Bias는 2.56 mm/day의 결과를 보였다. 동일한 기간에 대하여 설마천 지역에서의 플럭스 타워 관측과 비교한 결과, 총 582개 자료에 대하여 RMSE는 1.92 mm/day, Bias는 1.45 mm/day의 결과를 보였다. 기상청 국가기상위성센터의 위성증발산량이 봄과 가을철에 다소 높게 산출되는 경향이 있었으나, 증발산량의 변화경향은 유사하게 나타났다. 이러한 결과를 바탕으로 동아시아 지역 위성 증발산량 변화를 감시하고 있으며 향후, 수문 및 기후 분야에서 가뭄 모니터링 등의 연구에도 활용할 수 있을 것이다.

  • PDF

Comparison of Surface Fluxes Based on Landuse Characteristics Near Gangjeong-Goryeong Weir of the Nakdong River (낙동강 강정고령보에서 관측된 플럭스의 지표면에 따른 특성 비교)

  • Kahng, Keumah;Koo, Hae-Jung;Byon, Jae-Young;Park, Young-San;Jung, Hyun-Sook
    • Journal of the Korean earth science society
    • /
    • v.34 no.6
    • /
    • pp.561-574
    • /
    • 2013
  • This study investigates energy fluxes measured near Gangjeong-Goryeong Weir of the Nakdong River of South Korea for more than a year, from July 2011 to September 2012, in order to analyze the applicability of the data for future impact analyses. Each of the two study sites is located in a rural area, surrounded by agricultural fields, and an urban industrial area. Sensible and latent heat fluxes are analyzed according to the wind direction. In the summertime, when the wind blows from the river, sensible heat tends to decrease and latent heat tends to increase at both sites. This result is considered to be caused by moisture transfer from the river. Bowen ratio, energy balance closure, momentum flux, and stability are analyzed as well. The Bowen ratio of the rural agricultural site turns out higher than that of the urban site regardless of the season. The energy balance closure is higher at the agricultural site compared to the urban area, which is mainly due to exclusion of the storage term calculation at the urban site. The momentum flux is greater at the urban site both in winter and summer. The instability lasts longer during daytime and in the summertime, when there is a strong turbulence. The data from these sites are appropriate to be used in analyzing the impact of river in surrounding areas for future studies.