• 제목/요약/키워드: 현열

검색결과 141건 처리시간 0.03초

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅱ) - 전열판의 회전수 변환에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.18-23
    • /
    • 2005
  • The experimental investigation was carried out to evaluate the performance of air-to-air heat exchanger with rotating porous plates newly developed in this study. The rotating porous plates are mounted with an equal interval of 18 mm inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. The material of the porous plate is cooper and its thickness is 1.0 mm. Air flow rate is varied from 10 to 120 m3/h. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat exchange performance increased with the increase in RPM of the porous rotating discs at the conditions of the same air flow rate. The sensible heat exchange efficiency was maximum 60 to 70 percent, and enthalpy exchange efficiency 50 to 60 percent.

  • PDF

폐기물 합성가스의 활용을 위한 고온 정제 공정 적용 연구 (A study on the hot gas cleanup of waste-derived fuel gas)

  • 김나랑;유영돈;정기진;김정헌;김병환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.172.2-172.2
    • /
    • 2011
  • 다양한 저급연료나 폐기물로부터 가스엔진이나 연료전지의 연료로 사용하기위한 연료가스를 얻기 위한 방법으로 가스화 기술을 적용할 수 있다. 폐기물의 가스화를 통해 발생된 합성가스에는 CO, $H_2$, $CO_2$와 같은 주요성분 이외에 황화합물($H_2S$, COS), 염소화합물(HCl), 고형 물질(분진)등의 오염물질이 포함되어 있으므로, 이용목적에 따라 적절한 정제 기술이 필요하게 된다. 현재 가장 널리 알려진 저온 습식 정제공정은 장치운전이 쉽고 오염물질 제거효율이 높은 장점이 있으나, 합성가스 온도를 상온까지 낮추기 때문에 현열 손실이 발생하는 단점을 가지고 있다. 고온 건식 정제공정에 의해 $300^{\circ}C$ 이상의 고온에서 오염물질의 제거가 가능하다면 에너지 이용효율을 높일 수 있고, 습식공정에 의해 발생되는 폐수처리에 따른 비용 절감효과도 얻을 수 있다. 폐기물 합성가스를 최종 적용처에 이용하기위한 고온 정제 공정의 적용을 위해 흡착제를 이용하여 탈황, 탈염 실험을 실시하였고, 실험결과로부터 장치 설계의 기초인자를 도출하였다.

  • PDF

빙축열 시스템의 효율적인 제어를 위한 냉방부하 예측에 관한 연구 (A Study on Estimation of Cooling Load for Effective Control of Ice Thermal Storage System)

  • 유성연;한규현;이제묘;한승호
    • 설비공학논문집
    • /
    • 제20권2호
    • /
    • pp.128-136
    • /
    • 2008
  • It is necessary to estimate the cooling load of the next day for effective control of ice thermal storage system. In this paper, new methodology is proposed to estimate the cooling load using design parameters of building and predicted weather data. Only six input parameters such as sensible heat coefficient and constant, latent heat coefficient and constant, maximum and minimum temperature are necessary to obtain hourly distribution of cooling load for the next day. Two benchmarking buildings(hospital and research institute) are selected to validate the performance of the proposed method, and the estimated cooling loads in hourly and daily bases are calculated and compared with the measured data for E hospital. The estimated results show fairly good agreement with the measured data for both buildings.

하이브리드 제습냉방시스템의 성능평가 연구 (A Study on the Performance Evaluation of a Hybrid Desiccant Cooling System)

  • 황원백;김용찬;이대영
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Improvement in the energy efficiency has been studied of the desiccant cooling system by applying a vapor compression type heat pump to modify the system into a hybrid system. The cycle simulation was performed and the results were compared between a reference desiccant cooling system composed of a desiccant rotor, a sensible rotor and a regenerative evaporative cooler, and a hybrid desiccant cooling system with the sensible rotor being replaced by a heat pump. Though the electric consumption increases as much as the compressor power consumption, the total cooling capacity increases and the thermal energy input decreases by the addition of the heat pump. Therefore, the total energy efficiency can be improved if the increase in the electric consumption can be compensated with the increase in the cooling capacity and the decrease in the thermal energy input. The results showed that the total energy efficiency is optimized at a certain heat pump capacity. When the heat from the CHP plant is used for the thermal energy input, the energy consumption of the hybrid system is reduced by 20~30% compared with the reference system when the heat pump shares 30~40% of the total cooling capacity.

배기열 회수용 종이 열교환기의 성능예측에 관한 연구 (A Study on the Performance Prediction of Paper Heat Exchanger for Exhaust Heat Recovery)

  • 유성연;김진혁;정민호;지명석
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.372-380
    • /
    • 2008
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. Paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air. The purpose of this research is to obtain the experimental correlations for the friction factor, heat transfer coefficient, mass transfer coefficient and permeance of paper heat exchanger, which can be used to predict the performance of the paper heat exchanger. Pressure drops at various velocities, and sensible and latent heat transfer rates at various dry-bulb temperatures, relative humidities and specific humidities are measured to derive experimental correlations. The results of prediction using correlations show fairly good agreement with the experimental data obtained in the actual operating conditions.

다양한 기후조건에 따른 유역에서의 물과 에너지 분배 (Water and energy partitioning of catchments under various climatic conditions)

  • 유상현;백경록
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.103-103
    • /
    • 2023
  • 질량 및 에너지 보존 법칙은 수문현상을 포함한 자연 현상의 기본 법칙이다. 유역에서 물의 질량 보존은 강수량 P가 유출량 Q, 증발산량 E, 그리고 육역저수량변화 ΔS로 분할되는 것(P=Q+E+ΔS)을 의미하며 열 에너지 보존은 순복사에너지 Rn이 잠열 λE, 현열 H, 그리고 지열 G로 분할되는 것(Rn=λE+H+G)을 의미한다. 유역에서 물과 에너지의 분배 과정은 E로 연결되어 있으며 이 두 과정을 포괄적으로 이해하는 것은 기후 및 지표환경의 변화를 예측하고 대비하는데 중요하다. 이 연구에서는 미국 전역의 400여개 유역에 대한 정보를 제공하는 Model Parameter Estimation Project(MOPEX) 데이터를 이용하여 유역의 기후 조건에 따라 물과 에너지의 분배가 어떻게 달라지는지 Budyko 평면에서 분석했다. 장기간에 대해 ΔS와 G는 무시할 수 있다는 가정하에 건조한 유역일수록 P, Q, 그리고 E 모두 작게 나타나는데 P와 Q의 감소폭이 훨씬 크기 때문에 E의 P에 대한 비는 크게 나타났다. 또한 건조한 유역일수록 E는 작고 Rn이 크기 때문에 H가 크게 나타났으며 H가 큰 유역일 수록 유역의 최대 기온과 최저 기온의 차이가 크게 나타났다. 이러한 변화는 동일한 유역내에서 물과 에너지 분배의 시간적 변화로도 나타나고 있다.

  • PDF

저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석 (Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy)

  • 김경훈;김경천
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.483-491
    • /
    • 2014
  • 본 연구에서는 현열 형태의 저온 열원과 LNG의 냉열을 이용하는 복합 동력 생산시스템에 대한 열역학적 성능 해석을 수행하였다. 시스템의 작동유체로서 암모니아-물의 비공비 혼합물을 고려하였으며 재생기가 없는 기본 사이클과 있는 재생 사이클의 경우를 비교 해석하였다. 작동유체의 암모니아 농도나 응축 온도에 따라 시스템의 순생산일, 엑서지 파괴, 열효율이나 엑서지 효율 등에 미치는 다양한 영향에 대해 분석하고 논의하였다. 해석 결과는 시스템의 성능 특성이 작동유체의 암모니아 농도나 응축 온도에 따라 민감하게 변화하며, 열원유체 단위질량당 순생산일은 기본 사이클이 유리하나 열효율이나 엑서지 효율은 재생 사이클이 유리하다는 사실을 보여준다.

300MW급 IGCC 가스화 플랜트의 엔지니어링 현황 및 가스화 블록 성능예측 (Engineering Status of Gasification Plant in 300MW IGCC and Performance Prediction of Gasification Block)

  • 김유석;김봉근;백민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.130.1-130.1
    • /
    • 2010
  • 미국과 유럽에서는 이미 10여 년 전부터 250MW급 이상의 대용량 석탄IGCC 플랜트를 상업운전 하고 있으며, 일본과 중국을 비롯한 아시아에서도 대용량 플랜트를 시운전하고 있거나 건설 중에 있다. 한국에서는 제4차 전력수급계획에 의거 태안화력 부지 내에 300MW급 IGCC 플랜트 건설을 추진 중이며, 두산중공업은 '10년 상반기에 IGCC 가스화 플랜트에 대한 FEED 설계 (Front-Eng Engineering Design)를 완료하였다. 그 과정 중 설계조건에 의한 기본 엔지니어링 사항과 석탄 가스화 플랜트에 대한 성능예측 결과를 본 연구에서 소개한다. 가스화 플랜트의 엔지니어링은 가스화 블록과 가스정제 블록으로 구분하여 수행하였다. Process Data를 이용하여 PFD Development, P&ID Generation, Equipment Specification 개발, HAZOP 수행, Architecture Engineering 등의 순으로 FEED 설계를 진행하였다. BOD (Basis of Design)를 기준으로 운전조건별 Heat & Mass Balance와 Process Flow를 재검토하고 각 기기별 운전개념을 반영하여 P&ID를 개발하였다. 그리고 배관, 전기 및 제어에 대한 각종 Diagram 개발과 HSE (Health, Safety and Environment) 관련 설계를 수행하였다. IGCC 1호기의 엔지니어링 수행과 함께 Next 호기 자체설계 역량 확보를 위해 두산중공업은 'DIGITs'로 명명된 개념기본설계 Tool을 개발하고 있다. DIGITs는 공정모델링, 단위기기 개념설계, 공정구성 (Process Configuration) 및 종합 Database Package 형태로 구성된다. DIGITs에 의한 계산 결과 공정사 Process Data 기준시 가스화 블록 출구에서 Syngas HHV와 Syngas 현열은 각각 약 $636MW_{th}$와 약 $18MW_{th}$로, Plant 설계조건 $630MW_{th}$를 만족하는 것으로 예측되었다. 향후 DIGITs는 가스정제 블록 및 주변 BOP 설비 등과 연계한 종합 개념기본설계 Tool로써 개발 진행 중이다.

  • PDF

산악지역 도로건설에 따른 국지 대기순환의 변화에 관한 연구 (Study on Variation of Local Atmospheric Circulation Due to Road Development in Mountain Area)

  • 황수진;서광수;이순환
    • 한국지구과학회지
    • /
    • 제25권2호
    • /
    • pp.94-108
    • /
    • 2004
  • 얼음골 주변의 지표면 변화에 따른 중규모 대기순환장에 미치는 효과를 보기위하여 수치실험을 실시하였다. 얼음골 남북 경사면에서 발생하는 순환장은 지형과 단파복사에 의한 영향으로 다르게 나타나며, 비대칭을 이룬다. 그리고 이러한 비대칭은 18시까지 계속된다. 야간의 경우, 도로건설에 따른 대기순환장의 차이는 크지 않다. 이것은 주간 단파 복사에 의한 현열플럭스가 감소하며, 현열플럭스외의 다른 요소는 크게 영향을 미치지 않는다는 것을 의미한다. 도로의 건설은 현열플러스의 증가와 관련되고, 주간의 경우, 지형에 의한 곡풍과 결합하여 도로가 없는 경우에 비하여 상승류가 강하여진다. 최대풍속은 4.67 m/s이다. 그리고 이때 도로의 위치역시 주요한 요인으로 작용한다.

지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석 (Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment)

  • 안준;김재율;강병하
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.571-579
    • /
    • 2014
  • 하절기 에너지 이용의 합리화를 위해서는 소형 열병합 발전의 설비이용률을 높일 수 있는 지역냉방의 보급이 확대되어야 한다. 지역냉방에는 흡수식 냉동기와 제습냉방기 있는데 상대적으로 낮은 열원을 사용할 수 있어 지역난방에 연계할 수 있는 제습냉방이 공동주택용으로 각광을 받고 있다. 본 논문에서는 고체제습제를 이용며 현열로터 대신에 히트펌프를 사용한 하이브리드 제습냉방 시스템의 주거환경에서의 성능 특성을 분석하였다. 실내공급공기, 실내리턴공기, 실외흡입공기, 재생열량, 소비전력을 측정하여 인터넷을 이용한 모니터링을 통하여 데이터를 분석하였다. 전체에너지는 외기온도가 증가할수록 감소하였고 냉방능력은 외기온도가 증가할수록 증가하고, 외기습도가 감소할수록 증가하는 경향을 보였다. 성능계수는 냉방능력과 유사한 경향을 보이는 것으로 분석되었다.