• 제목/요약/키워드: 현열

검색결과 141건 처리시간 0.028초

옥상녹화시스템의 현열유동에 따른 동적온도모형 검증을 위한 모니터링 연구 (A Study on Monitoring to Investigate Dynamic Temperature Model by Sensible Heat Flux of Green Roof System)

  • 박은희;김태한;박상연;장성완
    • 한국환경복원기술학회지
    • /
    • 제18권6호
    • /
    • pp.15-25
    • /
    • 2015
  • The growth of impermeable layers in the city center due to today's urban development is emerging as a major cause of urban heat island effects as well as recurring inland flood damages. In order to cope with such disasters caused by climatic changes, an artificial ground afforestation system is suggested as a fundamental solution that addresses both water environment and heat environment. For the afforestation system to replace the current disaster prevention facilities, quantitative performance verification through related numerical analysis models and actual survey monitoring is necessary. Therefore, this study seeks to propose the performance predication method for the heat environment of the afforestation system by looking into correlations between measurements by physical vegetation indicators such as LAI and FVC and forecasts from FASST, a vegetation canopy model used by US Corps of Engineers.

한국 서해의 수온역전 현상 (Inversion Phenomena of Temperature in the Yellow Sea)

  • 김희준;윤홍주;양성기
    • 수산해양기술연구
    • /
    • 제18권2호
    • /
    • pp.91-96
    • /
    • 1982
  • 1965년부터 1979년까지의 해양관측자료를 사용하여 우리나라 서해에서 일어나는 수온역전 현상을 조사하였다. 그 결과는 다음과 같다. (1) 겨울의 수온역전 현상은 전 해역과 모든 수심에 걸쳐서 일어난다. (2) 여름은 제주도 서방 해역에서만 비교적 많이 일어난다. 이와 같은 수온역전 현상은 겨울의 경우는 현열손실, 잠열손실 및 남하 Ekman 수송 등에 의한 표면 냉각효과 때문으로 생각된다. 여름의 경우는 온도와 염분의 성질이 서로 다른 황해 저층수와 황해 난류가 제주도 서방 해역에서 경계를 이루고, 서로 혼합되는 과정에서 생기는 것으로 보여진다.

  • PDF

자갈식 축열조의 축열특성에 관한 연구 (A study on the Thermal Characteristics of a Thermal Storage Tank for using Gravels)

  • 박정원;박봉규;안상규
    • 태양에너지
    • /
    • 제12권1호
    • /
    • pp.81-87
    • /
    • 1992
  • 본 연구의 목적은 건물의 냉난방에 이용되는 현열이용형 축열조의 축열 특성을 규명하는데 있었다. 실험에 사용된 축열재는 자갈이었으며 일정한 온도조건하에서 축열재 사이를 통과하는 유체의 유동속도와 자갈의 크기별로 실험을 하였다. 자갈의 크기와 유속을 변화시켜 축열량과 축열효율을 실험적으로 구한 결과 축열재의 충진율이 72.5%이고 유속이 0.14m/s일 때가 최단시간 내에 최대축열량에 도달하였으며, 축열효율도 가장 높았다.

  • PDF

HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a)

  • 김영중;임장순
    • 태양에너지
    • /
    • 제17권2호
    • /
    • pp.3-11
    • /
    • 1997
  • 열펌프건조기는 증발기에 의한 냉각및 감습기능과 응축기에 의한 가열기능을 대류형건조기와 연계시킴으로써 필연적 손실로 분류되던 배기가 갖고 있는 현열과 잠열을 회수하여 재활용할 수 있는 이점이 있다. 본 연구에서는 HFC134a를 냉매로 사용한 배치형(batch type) 열펌프건조기를 설계제작하여 건조실의 유지온도, 공기의 바이패스비(bypass ratio), 냉매의 과열도를 일정하게 유지하고 정면풍속(face velocity)과 압축기속도를 변화시켜 건조기의 성능을 분석하였으며 정면풍속의 증가에 따라 열펌프의 성적계수는 증가하나 SMER(Specific Moisture Extraction Rate)은 감소하였다.

  • PDF

東海海面 熱交換에 影響을 미치는 大氣 및 海洋的 要因 (Atmospheric and Oceanic Factors Affecting the Air-Sea Thermal Interactions in the East Sea (Japan Sea))

  • 강용규
    • 한국해양학회지
    • /
    • 제19권2호
    • /
    • pp.163-171
    • /
    • 1984
  • 대기 및 해양적 요인들이 동해의 해면을 통한 열교환에 미치는 영향을 구명 하기 위하여, 해양의 열수지에 근거한 해석적인 모델을 만들고, 이 모델을 통하여 동해상 해면 열교환의 각 성분과 대기 온도의 연변화를 해석적으로 재현 (simulation) 하였다. 모델에 의한 이론적인 결과에 의하면, 동해에서 난류에 의한 열수송이 클수록 열복사, 잠열 및 현열의 방출이 증가한다. 그리고 표면수온이 증 가 함에 따라 잠열은 증가하지만, 역복사와 현열은 감소한다. 동해에서 연평균 수온이 1$^{\circ}C$ 증가하면 해상 기온의 연평균이 1.2$^{\circ}C$ 증가하는 효과를 가져오며, 해양의 저열량의 크기는 해면을 통한 열교환의 연변화에 지대한 영향을 미친다.

  • PDF

LNG 냉열을 이용하는 유기랭킨사이클(ORC)의 열역학적 성능 특성 (Thermodynamic Performance Characteristics of Organic Rankine Cycle (ORC) using LNG Cold Energy)

  • 김경훈;하종만;김경천
    • 한국가스학회지
    • /
    • 제18권2호
    • /
    • pp.41-47
    • /
    • 2014
  • 본 논문에서는 유기랭킨사이클과 LNG 사이클로 구성된 복합사이클의 열역학적 성능 해석을 수행한다. 이 복합사이클에서는 현열 형태의 저등급 폐열을 사용하며 LNG 냉열은 열싱크 뿐 아니라 동력 생산에도 사용된다. 시스템의 성능에 대한 터빈입구압력, 응축온도, 열원온도 등 주 파라미터들의 영향을 상세하게 분석한다. 시뮬레이션 결과는 이 복합시스템은 LNG 냉에너지를 사용하지 않은 일반의 ORC에 비해 현저하게 성능이 개선될 수 있음을 보여준다.

다양한 형태의 단속표면을 갖는 공조기용 핀-관 열교환기의 열전달 특성 (Heat transfer characteristics of fin and tube heat exchangers with various interrupted surface for air conditioning application)

  • 윤점열;이관수
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.3938-3948
    • /
    • 1996
  • This study is related with the experimental investigation on the heat transfer and pressure drop characteristics of the fin-and-tube heat exchangers with three different interrupted fins and a plane fin for air-conditioning application. Experiments were conducted accordingly following the appropriate development process. Geometry similitude experiment was introduced to predict the performance of fins, and prototype experiment was also performed to confirm the validity of geometry similitude experimental results. However, these experimental results were limited to the sensible heat transfer characteristics of the heat exchangers. Hence, additional experiment was performed using refrigerant to investigate the latent heat transfer characteristics. This paper presents an appropriate process for the development of a new type heat exchanger. Sensible and latent heat transfer characteristics for each fin configuration is also provided along with the optimal fin configuration.

습증기를 포함한 연소가스의 폐열회수를 위한 열교환기 성능 예측 (Performance Prediction of Heat Exchanger for Waste Heat Recovery from Humid Flue Gases)

  • 정동운;이상용;이한주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.276-281
    • /
    • 2000
  • A simulation program using the mass transfer correlation was constructed to analyze 1-D simplified condensing flow across the tube bank. Higher efficiency was anticipated by reducing the flue gas temperature down below the dew point where the water vapor in the flue gas is condensed at the surface of the heat exchanger; that is, the heat transfer by the latent heat is added to that by the sensible heat. Thus, there can be an optimum operating condition to maximize the heat recovery from the flue gas. The temperature rises of the flue gas and the cooling water between the inlet and the outlet of the tube bank were compared with the experimental data reported previously. The predicted results agree well with the experimental data. Using this simulation program, the parametric studies have been conducted fur various operating conditions, such as the velocities and temperatures of the vapor/gas mixture and the cooling water, the number of the rows, and the conductivity of the wall material.

  • PDF

건물 공조용 냉수 코일의 열 설계 (Thermal Design of a Cooling Coil for Building Air Conditioning)

  • 김내현;변호원
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6445-6452
    • /
    • 2015
  • 건물용 공기조화기의 냉수 코일은 작동조건에 따라 건표면, 습표면 또는 부분적인 습표면이 형성된다. 따라서 냉수코일을 적절히 설계하기 위해서는 건표면과 습표면, 그리고 부분적 습표면에 대한 열전달 해석이 필요하다. 본 연구에서는 미소체적에 대한 해석을 통하여 냉수코일의 성능을 계산하는 미소체적 모델을 제시하였다. 해석 모델의 예측치를 냉수코일 실험결과와 비교한 결과 미소 체적 모델은 공기측 전열량을 10.1% 이내에서 예측하고 공기측 압력손실을 11.1%, 현열비도 5.7%내로 예측하였다. 해석 모델을 활용하여 물측 회로의 변화가 냉수코일의 성능에 미치는 영향을 검토하였다.

다공형 전열판의 회전에 의한 열교환시스템의 성능에 관한 연구(Ⅰ) - 환기측과 외기측의 풍량 변화에 대하여 - (Study on the Performance of Total Heat Exchanger with Rotating Porous Plates)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.11-17
    • /
    • 2005
  • This paper reports an experimental study on the performance evaluation of air-to-air heat exchanger with rotary type newly developed in this study. Air flow rate is varied from 10 to 120 m3/h. The range of RPM of the porous rotating discs mounted inside the heat exchanger unit is 0 to 50. The temperature of the return air side is set by adjusting heat supply at heater. The material of the porous rotating discs is cooper and its thickness is 1.0 mm. The heat transfer rate increased with the increase in air flow rate. It was found that the heat transfer rate, as the temperature of the return air side was increased, was improved due to higher temperature difference. The heat exchange performance increased with the increase in the temperature of the return air side at the conditions of the same RPM. The sensible heat exchange efficiency was maximum 68 to 76 percent, and enthalpy exchange efficiency 64 to 74 percent.

  • PDF