• Title/Summary/Keyword: 현성 확산계수

Search Result 21, Processing Time 0.021 seconds

Diffus ion-Weighted MR Imaging of Spinal Cord Infarction (척수경색의 확산강조자기공명영상)

  • 김윤정;서정진;임남열;정태웅;김윤현;박진균;정광우;강형근
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.166-172
    • /
    • 2002
  • Purpose : To evaluate the usefulness of diffusion-weighted imaging(DWI) and quantitative apparent diffusion coefficient (ADC) maps in the patients with spinal cord infarction. Materials and methods : We studied 6 patients presented symptoms with spinal cord infarction, retrospectively (3 men and 3 women). We obtained multi-shot echo planar-based, DWI using 1.5T MR scanner at 5.4 mean days after the onset of ischemic symptoms. In six patients, signal intensity was acquired at conventional b value $1000s/\textrm{mm}^2$). The ADC value for the normal spinal cord and for infarcted lesions was measured from the trace ADC maps by using regions of interest positioned over the spinal cord. We analyzed signal intensity of lesion on MRI and DWI, and compared with ADC values in infarcted lesions and normal site. Results : T1-weighted MR image showed isosignal intensity in four of six patients and low signal intensity in two of six. T2-weighted MR image demonstrated high signal intensity in all of six. All DWI were considered to be diagnostic. All of six depicted a bright signal intensity on DWI. ADC values of infarcted lesion were measured lower than that of normal spinal cord on ADC map. The differences in ADC values between infarcted and normal spinal cord were significantly different (p<0.05). Conclusion : It is possible to obtain DWI and ADC map of the spinal cord and DWI may be useful in the early diagnosis and localization of lesion site in patients with spinal cord infarction.

  • PDF

Using a 7.0T animal MRI comparison of ADC values and Pathologic Findings (7.0T 동물용 MRI을 이용한 종양의 현성확산계수와 병리학적 소견의 평가)

  • Seong, jae gu;Lim, cheong hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.201-202
    • /
    • 2011
  • 본 연구에는 7.0T 동물용 자기공명영상장치를 이용하여 인간의 췌장암 세포인 CFPAC-1를 이종 이식한 쥐에서 자기공명영상을 획득하여 최적화된 검사 Protocol을 정립하며, 동물 실험에서 밝혀진 종양특성과 확산강조영상과의 비교 분석을 해보고 현성확산계수 영상이 췌장암 이종이식 모형의 종양 세포 내부 구조에 관하여 어떠한 정보를 제공 할 수 있는지 알아보고자 한다. 13마리의 쥐의 26개의 종양을 전형적으로 주입 후에 2~4주 뒤에 직경이 5~10mm가 되었을 때 imaged 하였으며, pathologic specimenm을 위해 sacrificed 하였다. isofluoran gas anesthesia를 이용하여 동물 마취 하였다. 사용된 장비로는 small-animal MR images (7.0-T)를 (Bruker BioSpin GmbH, Rheinstetten, Germany)이용하여 Fast T2-weighted 와 single-shot EPI DW image를 얻었다. 종양은 H&E 염색과 CD31와 VEGF에 대한 면역조직학 염색을 하여 종양의 cellularity와 microvessel density(MVD), 종양 내 괴사 정도를 평가하였다. CFPAC-1의 현성확산계수값은 $0.7327{\pm}0.1075{\pm}10^{-3}mm2/s$이였으며, 현성확산계수는 종양내 괴사 정도와 연관성을 보였다(R = 0.7417, p = 0.0001) 이처럼 현성확산계수는 종양 내 괴사 정도 등의 현미경적구조변화를 반영하는 대리인자로 사용될 수 있음을 확인하였다.

  • PDF

Assessment of Osteoporosis Based on Changes in SNR and ADC Values on MR Diffusion Weighted Images (확산강조영상에서 신호대 잡음비, 현성 확산 계수 변화에 따른 골다공증 평가)

  • Cho, Jae-Hwan;Kim, Yeong-Soo
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.70-77
    • /
    • 2010
  • This study tested how S/N (Signal to Noise Ratio) ratios and ADC (apparent diffusion coefficient) values vary with different T-scores in a group of patients with osteoporosis. Based on DEXA (Dual Energy X-ray Absorptiometry) T-scores for L1.L4 for two groups of subjects consisting of 30 healthy people without osteoporosis and 30 patients who came for treatment of waist (lumbar or low back) pain and were suspected to have osteoporosis as judged from the simple X-ray findings, this study classified every spine into two groups of osteoporosis and osteopenia. Signal intensity measurements were made in the four regions of L1 to L4 on diffusion-weighted MR images obtained using 1.5T MR scanner, while ADC measurements were obtained from ADC map images. As an approach for quantitative analysis, the comparison of the variances in S/N ratios and ADC values for varying T-scores in the selected regions of interest was carried out based on averaged T-scores, S/N ratios, and ADC values. Also, the variances in S/N ratios and ADC values for each of the groups of osteoporosis and osteopenia, which were classified into by T-scores, were compared. For qualitative analysis, a careful naked eye examination of signal intensity differences in the area of L4 was made on T1-weighted sagittal images for each of the healthy (normal), osteopenia, and osteoporosis groups. In the qualitative analysis, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the S/N ratios on diffusion-weighted MR images also decreased, with the greatest decrease in the S/N ratio found in the osteoporosis group. Additionally, among the three groups, the lowest S/N ratio was found in the osteoporosis group. With respect to ADC map, it was found that for both the osteopenia group and the osteoporosis group, as T-scores deceased, the ADC values on diffusion-weighted MR images also decreased, with the greatest decrease in the ADC values found in the osteoporosis group. Additionally, among the three groups, the lowest ADC value was found in the osteoporosis group. On the other hand, in the qualitative analysis, the osteoporosis group showed the highest signal intensity. Additionally, among the three groups, the lowest signal intensity was found in the healthy (normal) group. It was found that as osteoporosis progressed, S/N ratio and ADC decreased, whereas signal intensity increased on T1-weighted images. Also, in diagnosing osteoporosis, MRI tests turned out to be (more) effective.

The quantitative analysis of Diffusion Weighted Imaging in Breast MRI (유방 MRI 검사에서 확산강조영상의 정량적 분석)

  • Cho, Jae-Hwan;Kim, Hyeon-Ju;Hong, Yin-Sik;Lee, Hae-Kag
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.149-154
    • /
    • 2011
  • The purpose of this study was to examine the usefulness of diffusion weighted images in breast MRI by performing a quantitative comparative analysis in patients diagnosed with DCIS. On a 3.0T MR scanner, diffusion weighted images and ADC map images were obtained from 20 patients histologically diagnosed with ductal carcinoma in situ (DCIS). The findings from the quantitative image analysis are the following: The diffusion weighted images showed higher SNR and CNR at the lesion area. In addition, the ADC values were lower at the lesion area.

SNR and ADC Value Change before and after the injection of contrast medium during DWI test on metastatic spinal cancer patients (전이성 척추암 환자의 확산강조영상 검사 시 조영제 주입 전.후 ADC값의 변화에 대한 고찰)

  • Kim, Eng-Chan;Kim, Ki-Hong;Park, Cheol-Soo;Lee, Sun-Yeob;Yoo, Heung-Joon;Cho, Jae-Hwan;Jang, Hyun-Cheol;Kim, Bo-Hui;Han, Man-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • To examine the possible changes in the SNRs, CNRs, and ADC values for lumbar spines with metastasis based on the DW images before and after contrast agent injection taken from metastatic spinal cancer patients using a 1.5 T MR machine. The quantitative analysis revealed that in case of spinal cancer subjects, both SNRs and CNRs at all of those assessed locations significantly increased on the DWI after contrast agent injection compared to before, while on the ADC map images, SNRs significantly decreased. On the other hand, significantly decreased ADC values at all the assessed locations were found on the ADC map images. With reference to the normal group, significantly increased SNRs were found at all of the assessed locations on the DWI image after injection compared to before, while significantly decreased SNRs were found on the ADC map images. Also, significantly decreased ADC values at all the assessed locations were found on the ADC map images. For the qualitative analysis, after contrast agent injection, significantly increased signal intensities were found at the locations with spinal cancer on the DWI. In contrast, significantly decreased signal intensities were found on the ADC map images. The implication from the results showing that SNR and CNR significantly increased while ADC value significantly decreased at, above, and below the location of metastatic spinal cancer on DWI after contrast agent injection is that DWI obtained after contrast agent injection can be made available for wider application to vertebral disorders.

Effect of Gd-DTPA on Diffusion in Canine Brain with Hyperacute Stroke (초급성 뇌경색을 일으킨 개에서 Gd-조영제의 주입이 뇌의 확산에 미치는 영향)

  • 김범수;정소령;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.2
    • /
    • pp.158-165
    • /
    • 2002
  • Purpose : To evaluate the effect of Gd-DTPA on signal intensity of diffusion-weighted magnetic resonance(MR) image and apparent diffuse coefficient (ADC) in dog brain with hype racute stroke. Materials and methods : Experimental canine model of hyperacute cerebral infarction was made by selective intraarterial embolization with particulate embolic material. Diffusion-weighted MR imaging was performed in five dogs at 1 hour after the embolization of internal carotid artery. After intravenous bolus injection of Gd- DTPA, additional 11 diffusion-weighted MR images were serially obtained from 2 minutes to 90 minutes after injection in each dog. The author evaluated findings of hyperacute cerebral infarction on diffusion-weighted MR imaging, and calculated mean signal intensity and mean ADC in infarcted region and contralateral normal region. Statistical analysis of mean signal intensity, mean ADC and contrast-noise ratio before and after Gd-DTPA injection was performed. Results : Hyperacute cerebral infarction developed in all five dogs on diffusion-weighted MR images obtained 1 hour after embolization. The area of hyperacute infarction had steady increase in signal intensity on diffusion-weighted MR image and decrease in ADC. In normal perfusion area, decrease in signal intensity was observed at 2 minutes the Gd-DTPA injection, whereas ADC did not changed. Conclusion : Intravenous injection of Gd-DTPA had no influence on ADC in both hyperacute infarction and normally perfused are a, but caused initial transient signal reduction in normally perfused area on diffusion-weighted MR image due to susceptibility effect of Gd-DTPA. It is important to calculate ADC in evaluating the effect of diffusion after injection of Gd-DTPA.

  • PDF

Does the ADC Map have Additional Clinical Significance Compared to the DWI in the Brain Infarction? (뇌경색에서 확산강조영상과 비교하여 현성확산계수 지도의 부가적인 임상적 중요성이 있는가?)

  • Choi, Sunseob;Ha, Dong-Ho;Kang, Myong-Jin;Lee, Jin Hwa;Yoon, Seong Kuk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.267-274
    • /
    • 2013
  • Purpose : To re-evaluate additional clinical significance of the apparent diffusion coefficient (ADC) map in the inference of infarction stage, authors studied the evolution patterns of the DWI and the ADC map of the brain infarction. Materials and Methods: In 127 patients with cerebral infarctions, including follow-up checks, 199 studies were performed. They were classified as hourly (117 studies)-, daily (108 studies)-, weekly (62 studies)-based groups. The signal intensity (SI) was measured at the core of the infarction and contralateral area with ROI of 0.3 $cm^2$ or more on the images of the DWI and the ADC map, and calculated the ratios of SI and ADC value of the infarction area / contralateral normal area, and compared the patterns of the change according to the evolution. Results: Infarction was detected as early as 1 hour after the attack, and the ratio of SI in the DWI became over than 2 after 12 hours, which showed a plateau until the 6th day. Thereafter, it decreased slowly to 1 on the 30th day, and changed to lower SI than the surrounding brain. The ratio in the ADC map became 0.46 in 24 hours after the attack, and increased slowly to 1 in the 15th day. Thereafter, it became a higher value than the surrounding brain. Overall, the ratio in the ADC map changed earlier than in the DWI, and the ratio curves showed inverse pattern each other according to the evolution of the infarction. Conclusion: The evolution patterns of infarction on the ADC map showed an inverse curve of DWI curve, which means that the ADC value is accurately predictable from DWI, and the ADC map joined with the DWI seems helpful in the determination of subacute infarction between 15 to 30 days.

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

SNR and ADC Changes at Increasing b Values among Patients with Lumbar Vertebral Compression Fracture on 1.5T MR Diffusion Weighted Images (1.5T MR 기기를 이용한 확산강조영상에서 b Value의 증가에 따른 요추압박골절 환자의 신호대 잡음비와 현성 확산 계수의 변화)

  • Cho, Jae-Hwan;Park, Cheol-Soo;Lee, Sun-Yeob;Kim, Bo-Hui
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.52-59
    • /
    • 2010
  • To examine among patients with vertebral compression fracture the extent to which signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values at the lumbar vertebral compression fracture site vary on diffusion-weighted MR images according to varying b values on the 1.5T MR device. Diffusion-weighted MR images of 30 patients with compression fracture due to chronic osteoporosis who underwent vertebral MRI from Jan. 2008 to Nov. 2009 were respectively obtained using a 1.5-T MR scanner with the b values increased from 400, 600, 800, 1,000 to $1,200\;s/mm^2$. For diffusion-weighted MR images with different b values, the signal-to-noise ratio (SNR) was assessed at three sites: the site of compression fracture of the lumbar vertebral body at L1 to L5, and both the upper and lower discs of the said fracture site, while for ADC map images with different b values, the SNR and ADC were respectively assessed at those three sites. As a quantitative analysis, diffusion-weighted MR images and ADC map images with b value of $400\;s/mm^2$ (the base b values) were respectively compared with the corresponding images with each different b value. As far as qualitative analysis is concerned, for both diffusion-weighted MR and ADC map images with b value of $400\;s/mm^2$, the extent to which signal intensity values obtained at the site of compression fracture of the lumbar vertebral body at L1 to L5 vary according to the increasing b values were examined. The quantitative analysis found that for both diffusion-weighted MR and ADC map images, as the b values increased, the SNR were relatively lowered at all the three sites, compared to the base b value. Also, it was found that as the b values increased, ADC valueswere relatively lowered at all the three sites on ADC map images. On the other hand, the qualitative analysis found that as the b values increased to more than $400\;s/mm^2$, the signal intensity gradually decreased at all the sites, while at the levels of more than $1,000\;s/mm^2$, severe image noises appeared at all of the three sites. In addition, higher signal intensity was found at the site of compression fracture of the lumbar vertebral body than at the discs. Findings showed that with the b value being increased, both the signal-to-noise ratio (SNR) and Apparent Diffusion Coefficient (ADC) values gradually decreased at all the sites of the lumbar vertebral compression fracture and both the upper and lower discs of the fracture site, suggesting that there is a possibility of a wider range of applications to assessment of various vertebral pathologies by utilizing multi b values in the diffusion-weighted MRI examination.

Pre-operative Evaluation of Consistency in Intra-axial Brain Tumor with Diffusion-weighted Images (DWI) and Conventional MR Images (확산강조영상과 고식적 자기공명영상을 이용한 수술 전 축내 뇌종양의 경도 평가)

  • Oh, Moon-Sik;Ahn, Kook-Jin;Choi, Hyun-Seok;Jung, So-Lyung;Lee, Yoon-Joo;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.2
    • /
    • pp.102-109
    • /
    • 2011
  • Purpose : To retrospectively evaluate the usefulness of diffusion-weighted images, ADC maps and conventional MR images for determination of brain tumor consistency. Materials and Methods : Twenty-three patients with brain tumor underwent MR examinations with T1, T2 and diffusion-weighted images. Regions of interest (ROIs) were drawn in the tumors, and the measured signal intensities (SI) were normalized with the contralateral side. We evaluated the correlation between SI ratios from various images and tumor consistency assessed at surgery. In three patients with both cystic and solid components, each component was evaluated independently. Qualitatively observed SIs were also correlated with tumor consistency. Results : Statistical analysis revealed significant correlation between tumor consistency and ADC ratio (r = -0.586, p = 0.002), SI ratios on T2-weighted images (r = -0.497, p = 0.010), and observed SIs on T2-weighted images (r = -0.461, p = 0.018). The relative ratio of ADC value correlated with tumor consistency most strongly. Conclusion : The measured ratio of ADC, SI ratio and observed SI grade on T2-weighted images can provide valuable information about the consistency of brain tumor.