• Title/Summary/Keyword: 현미경 검사법

Search Result 98, Processing Time 0.022 seconds

Reliability Evaluation of Semiconductor using Ultrasound (초음파를 이용한 반도체의 신뢰성 평가)

  • Jang, Hyo-Seong;Ha, Job;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.598-606
    • /
    • 2001
  • Recently, semiconductor packages trend to be thinner, which makes difficult to detect defects therein. A preconditioning test is generally performed to evaluate the reliability of semiconductor packages. The test procedure includes two scanning acoustic microscope (SAM) tests at the beginning and end of the entire test, in order to help detect physical defects such as delaminations and package cracks. In particular, of primary concern are package cracks and delaminations caused by moisture absorbed under ambient conditions. This paper discusses the failure mechanism associated with the moisture absorbed and encapsulated in semiconductors, and the use SAM to detect failures such as tracks and delaminations grown during the preconditioning test.

  • PDF

Study on methodology for the assessment of internal and marginal adaptation on fixed dental prosthesis (고정성 보철물의 내면 및 변연적합도를 평가하는 방법에 대한 고찰)

  • Pyo, Se-Wook;Lee, Jun-Jae;Han, Jung-Suk;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.3
    • /
    • pp.158-168
    • /
    • 2016
  • This article is to review various methods used to investigate internal and marginal adaptation of fixed dental prostheses, and to summarize a merit, worth, and limitation of each method, using some results of previous studies. The methods of measuring internal and marginal gap are divided into two categories in this study; in vivo and in vitro. In vivo methods are clinical evaluations, including exploration, radiography, and impression technique. In vitro methods are laboratory evaluations such as direct view, cross-sectioning, and silicone replica technique using microscope. Measuring by micro computed tomography (CT) or profilometer is also in vitro methods. In recent years, the development of scanning systems is able to analyze 3-dimensional internal and marginal space in detail. As measuring and analyzing technology become more advanced, the ability to thoroughly examine crown adaptation is becoming both simpler and more efficient.

Trial for Drug Susceptibility Testing of Mycobacterium tuberculosis with Live and Dead Cell Differentiation (세포 염색 방법을 이용한 결핵균 감수성 검사법)

  • Ryu, Sung-Weon;Kim, Hyun-Ho;Bang, Mun-Nam;Park, Young-Kil;Park, Sue-Nie;Shim, Young-Soo;Kang, Seongman;Bai, Gill-Han
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.3
    • /
    • pp.261-268
    • /
    • 2004
  • Background : The resurgence of tuberculosis and outbreaks of multidrug resistant (MDR) tuberculosis have increased the emphasis for the development of new susceptibility testing of the Mycobacterium tuberculosis for the effective treatment and control of the disease. Conventional drug susceptibility testings, such as those using egg-based or agar-based media have some limits, such as the time required and difficulties in determining critical inhibitory concentrations, but these are still being used in many diagnostic laboratories because of no better lternatives, considering cost and accuracy. To overcome these limits, a rapid and simple method for new susceptibility testing, using live and dead assays, was applied for a bacterial cell viability assay to distinguish dead from live bacterial cells based on two-color fluorescence. Materials and Methods Strains : Forty strains were used in this study, 20 susceptible to all antituberculosis drugs and the other 20 resistant to the four first line antituberculosis drugs isoniazid, rifampicin, streptomycin and ethambutol. Antibiotics : The four antibiotics were dissolved in 7H9 broth to make the following solutions: $0.1{\mu}g\;isoniazid(INH)/m{\ell}$, $0.4{\mu}g\;rifampicin(RMP)/m{\ell}$, $4.0{\mu}g\;streptomycin(SM)/m{\ell}$ and $4.0{\mu}g\;ethambutol(EMB)/m{\ell}$. Results : Live and dead Mycobacterium tuberculosis cells fluoresced green and red with the acridin (Syto 9) and propidium treatments, respectively. These results are very well accorded with conventional drug susceptibility testing by proportional method on Lowensen-Jensen media (L-J) containing 4 drugs (INH, RMP, EMB and SM), showing a 93.7 % accordance rate in susceptible strains and 95% in resistant strains. Conclusion : The results of the drug susceptibility testing using the live and dead bacterial cell assay showed high accordance rates compared with the conventional proportion method on L-J. This finding suggests that the live and dead bacterial cell assay can be used as an alternative to conventional drug susceptibility testing for M. tuberculosis strains.

Study on non-nickel-based sealing of anodic porous aluminum oxide by using NaAlO2 (알루민산 염을 포함한 다공성 알루미나의 무니켈 봉공처리제에 관한 연구)

  • Kim, Mun-Su;Yu, Hyeon-Seok;Choe, Jin-Seop
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.190.1-190.1
    • /
    • 2016
  • 봉공처리법은 다공성 알루미나를 제조 후에 내마모성의 증가, 침지된 염료의 봉인 등을 필요로 하여 이용하는 후처리 공정 중 하나이다. 상업적으로는 물 봉공처리나 니켈-아세트산 용액을 이용한 봉공처리를 주로 이용하지만 고온을 필요로 하거나 인체에 유독한 용액을 사용, 혹은 추가적인 봉공처리를 해주어야 한다는 단점들을 가지고 있다. 이에 본 연구에서는 독성이 적고 상온에서도 다공성 알루미나와 쉽게 반응할 수 있는 알루미늄 음이온 용액을 봉공처리에 이용하였다. 알루미늄 음이온 용액을 이용한 봉공처리는 알루미늄의 양극 산화를 진행한 이후에 알루미늄 음이온을 포함한 봉공처리제를 제조 후, 침지 처리하는 방식으로 봉공처리하였다. 봉공처리제의 pH 변화, 온도 변화, 침지 시간 등의 변수 요소에 따라서 최적화를 진행하였으며, 이 용액으로 봉공처리가 가능한지 주사 전자 현미경 분석을 통해 평가하였다. 이후 최적화된 조건과 기존에 상업적으로 사용하던 봉공처리법을 거친 후에 경도, 부식전위 검사, 내화학성 검사를 통해 성능의 변화를 확인하였으며 광전자 분광기를 통해 성분과 메카니즘을 예측하였다.

  • PDF

고대 금동 도금기법에 관한 연구-황남대총 고분 출토유물을 중심으로

  • Im, Seon-Gi;Jeong, Yeong-Dong;Park, Dong-Gyu;Gang, Seong-Gun
    • 보존과학연구
    • /
    • s.12
    • /
    • pp.42-62
    • /
    • 1991
  • A.D. 5세기 전반기경으로 추정되는 황남대총 고분에서 발굴출토된 유물 중 도금 기법이 적용된 대표적인 형태 및 용도의 유물 시료 13점을 선정 SEM-EDS 및 금속현미경에 의해 분석한 결과,시료의 도금피복 기술은 수은(Hg)에 의한 아말감(amalgam) 도금법에 의한 것으로 판명되었으며, 도금피막의 두께는 $5.99∼12.97\mum$ (단, 소지가 은인 시료 No.C는 $19.96\mum$)로 균일하고 치밀하게 도포되었다. 소지금속은 금속현미경 조직검사 결과 대부분 단조로 제조된 4.7∼11.5%의 연(Pb)을 함유하고 약 1.7% 내외의 아연(Zn)을 함유한 동합금이었다. 또한 내재된 불순물이나 기공이 매우 적은 것으로 보아 당시의 소지금속인 동합금 주조기술이 상당한 수준임을 알 수 있었다.

  • PDF

Evaluation of Fatigue Damage of Metal Matrix Composite by LFB Acoustic Microscopy (Line-Focus-Beam 초음파 현미경을 이용한 금속복합재료의 피로손상에 관한 연구)

  • Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.13 no.2
    • /
    • pp.40-47
    • /
    • 1993
  • Composites composed of a precipitation harden 2124 alloy matrix reinforced by SiC whiskers, which are fabricated by powder metallugy, are suscepttible to fatigue damage due to the pile-up of moving dislocation and the microcrack initiation along SiC-Al interfaces, especially at the external surfaces of a body. The initial process, such as pile-up of dislocation or microcrack, that corresponds to the stage I during fatigue failure process are too small to be detected and characterized by conventional ultrasonic technique. This paper describes the applicability of an acoustic microscope with Line-Focus-Beam(LFB) lens of 225MHz to evaluate fatigue damage of SiC whiskers reinforced Al alloy. The specimens which were 6.6mm thick, 13mm wide, and 105mm long in the gage section were fatigued in tension-tension under load control. The velocity of leaky surface and leaky pseudosurface acoustic waves are obtained by FFT analysis technique from V(z) curve which is a record of output of piezoelectric transducer. These results are discussed with the change of number of fatigue cycles. The result obtained by acoustic microscope is compared with that by ultrasonic technique generated at 5MHz with conventional surface wave transducers.

  • PDF

fiber Orientation Effects on the Acoustic Emission Characteristics of Class fiber-Reinforced Composite Materials (유리섬유강화 복합재의 AR특성에 대한 섬유배향 효과)

  • Kim, Jung-Hyun;Woo, Sung-Choong;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.429-438
    • /
    • 2003
  • The effects of fiber orientation on acoustic emission(AE) characteristics have been studied for the unidirectional and satin-weave, continuous glass-fiber reinforced plastic(UD-GFRP and SW-GFRP) tensile specimens. Reflection and transmission optical microscopy was used for investigation of the damage zone of specimens. AE signals were classified as different types by using short time fourier transform(STFT) : AE signals with high intensity and high frequency band were due to fiber fracture, while weak AE signals with low frequency band were due to matrix and interfacial cracking. The feature in the rate of hit-events having high amplitudes showed a process of fiber breakages, which expressed the characteristic fracture processes of individual fiber-reinforced plastics with different fiber orientations and with different notching directions. As a consequence, the fracture behavior of the continuous GFRP could be monitored as nondestructive evaluation(NDE) through the AE technique.

Characterization of Residual Stress in Shot Peened Al 7075 Alloy Using Surface Acoustic Wave (표면파를 이용한 쇼트피닝된 Al 7075 합금의 잔류응력 평가)

  • Kim, Chung-Seok;Kim, Yong-Kwon;Park, Ik-Keun;Kwun, Sook-In
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.291-296
    • /
    • 2006
  • The residual stress in shot-peened Al 7075 alloy was evaluated using surface acoustic wave (SAW). Shot peening was conducted to produce a variation in the residual stress with the depth below the surface under a shot velocity of 30 m/s. The SAW velocity was measured from the V(z) curve using a scanning acoustic microscopy (SAM). The Vickers hardness profile from the surface showed a significant work hardening near the surface layer with a thickness of about 0.25 mm. As the residual stress became more compressive, the SAW velocity increased, whereas as the residual stress became more tensile, the SAW velocity decreased. The variation in the SAW velocity through the shot peened surface layer was in good agreement with the distribution of the residual stress measured by X-ray diffraction technique.

Tolerance analysis of Multi-Configurative Microscopic System for Inspecting the Wire-Bonding Status of Semiconductor Chips (반도체 와이어 본딩 검사용 다중배치 현미경 광학계에 대한 공차분석)

  • Ryu, Jae-Myung;Kim, Jae-Bum;Kang, Geon-Mo;Jung, Jin-Ho;Baek, Seung-Sun;Jo, Jae-Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.149-158
    • /
    • 2006
  • We have analyzed various tolerances of the multi-configurative microscopic system for inspecting the wire-bonding of a reed frame by using the Gaussian bracket method and the equivalent lens method. The tolerances for the curvature and the thickness, which are axial symmetric tolerances, are given by varying the back focal length within a fecal depth under diffraction-limited conditions. Moreover, by using the trial and error method, the axial non-symmetric tolerances for decenter and tilt are established by assigning the 5% variation of MTF(modulation transfer function) at the spatial frequency of 50 lp/mm and at the field angle of 0.7 field. As the tolerances with the most probable distribution are distributed within the range of the decay rate of less than 5% independent of the probability distribution of tolerances, we can achieve completely the desired design performances of the multi-configurative microscopic system by using the various ranges of these tolerances.

Analysis of the Fracture Behavior of Plate-type Piezoelectric Composite Actuators by Acoustic Emission Monitoring (음향방출법을 이용한 평판형 압전 복합재료 작동기의 파괴거동 해석)

  • Woo, Sung-Choong;Goo, Nam-Seo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.220-230
    • /
    • 2006
  • Fracture behavior of a monolithic PZT and a plate-type piezoelectric composite actuator (PCA) has been investigated under a bending load at three points by an acoustic emission (AE) monitoring. AE signal from a monolithic PZT at the maximum bending load shows the characteristics of high amplitude and long duration with a low frequency band of $100{\sim}230kHz$ which is confirmed by fast Fourier transform (FFT). For a PCA, it is concluded that AE signals with high amplitude over 80dB and low dominant frequency band of $170{\sim}223kHz$ emitted in the stage I are due to the brittle fracture in the PZT layer and the delamination between the PZT layer and the adjacent fiber composite layer. Based on the above analysis of AE behavior and damage observations with an optical microscopy and a scanning electron microscopy, AE characteristics related to fracture behavior of asymmetrically laminated PCA have been elucidated.