• Title/Summary/Keyword: 허용기준

Search Result 1,697, Processing Time 0.028 seconds

Establishment of Analytical Method for Dichlorprop Residues, a Plant Growth Regulator in Agricultural Commodities Using GC/ECD (GC/ECD를 이용한 농산물 중 생장조정제 dichlorprop 잔류 분석법 확립)

  • Lee, Sang-Mok;Kim, Jae-Young;Kim, Tae-Hoon;Lee, Han-Jin;Chang, Moon-Ik;Kim, Hee-Jeong;Cho, Yoon-Jae;Choi, Si-Won;Kim, Myung-Ae;Kim, MeeKyung;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.3
    • /
    • pp.214-223
    • /
    • 2013
  • BACKGROUND: This study focused on the development of an analytical method about dichlorprop (DCPP; 2-(2,4-dichlorophenoxy)propionic acid) which is a plant growth regulator, a synthetic auxin for agricultural commodities. DCPP prevents falling of fruits during their growth periods. However, the overdose of DCPP caused the unwanted maturing time and reduce the safe storage period. If we take fruits with exceeding maximum residue limits, it could be harmful. Therefore, this study presented the analytical method of DCPP in agricultural commodities for the nation-wide pesticide residues monitoring program of the Ministry of Food and Drug Safety. METHODS AND RESULTS: We adopted the analytical method for DCPP in agricultural commodities by gas chromatograph in cooperated with Electron Capture Detector(ECD). Sample extraction and purification by ion-associated partition method were applied, then quantitation was done by GC/ECD with DB-17, a moderate polarity column under the temperature-rising condition with nitrogen as a carrier gas and split-less mode. Standard calibration curve presented linearity with the correlation coefficient ($r^2$) > 0.9998, analysed from 0.1 to 2.0 mg/L concentration. Limit of quantitation in agricultural commodities represents 0.05 mg/kg, and average recoveries ranged from 78.8 to 102.2%. The repeatability of measurements expressed as coefficient of variation (CV %) was less than 9.5% in 0.05, 0.10, and 0.50 mg/kg. CONCLUSION(S): Our newly improved analytical method for DCPP residues in agricultural commodities was applicable to the nation-wide pesticide residues monitoring program with the acceptable level of sensitivity, repeatability and reproducibility.

Open Skies Policy : A Study on the Alliance Performance and International Competition of FFP (항공자유화정책상 상용고객우대제도의 제휴성과와 국제경쟁에 관한 연구)

  • Suh, Myung-Sun;Cho, Ju-Eun
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.25 no.2
    • /
    • pp.139-162
    • /
    • 2010
  • In terms of the international air transport, the open skies policy implies freedom in the sky or opening the sky. In the normative respect, the open skies policy is a kind of open-door policy which gives various forms of traffic right to other countries, but on the other hand it is a policy of free competition in the international air transport. Since the Airline Deregulation Act of 1978, the United States has signed an open skies agreement with many countries, starting with the Netherlands, so that competitive large airlines can compete in the international air transport market where there exist a lot of business opportunities. South Korea now has an open skies agreement with more than 20 countries. The frequent flyer program (FFP) is part of a broad-based marketing alliance which has been used as an airfare strategy since the U.S. government's airline deregulation. The membership-based program is an incentive plan that provides mileage points to customers for using airline services and rewards customer loyalty in tangible forms based on their accumulated points. In its early stages, the frequent flyer program was focused on marketing efforts to attract customers, but now in the environment of intense competition among airlines, the program is used as an important strategic marketing tool for enhancing business performance. Therefore, airline companies agree that they need to identify customer needs in order to secure loyal customers more effectively. The outcomes from an airline's frequent flyer program can have a variety of effects on international competition. First, the airline can obtain a more dominant position in the air flight market by expanding its air route networks. Second, the availability of flight products for customers can be improved with an increase in flight frequency. Third, the airline can preferentially expand into new markets and thus gain advantages over its competitors. However, there are few empirical studies on the airline frequent flyer program. Accordingly, this study aims to explore the effects of the program on international competition, after reviewing the types of strategic alliance between airlines. Making strategic airline alliances is a worldwide trend resulting from the open skies policy. South Korea also needs to be making open skies agreements more realistic to promote the growth and competition of domestic airlines. The present study is about the performance of the airline frequent flyer program and international competition under the open skies policy. With a sample of five global alliance groups (Star, Oneworld, Wings, Qualiflyer and Skyteam), the study was attempted as an empirical study of the effects that the resource structures and levels of information technology held by airlines in each group have on the type of alliance, and one-way analysis of variance and regression analysis were used to test hypotheses. The findings of this study suggest that both large airline companies and small/medium-size airlines in an alliance group with global networks and organizations are able to achieve high performance and secure international competitiveness. Airline passengers earn mileage points by using non-flight services through an alliance network with hotels, car-rental services, duty-free shops, travel agents and more and show high interests in and preferences for related service benefits. Therefore, Korean airline companies should develop more aggressive marketing programs based on multilateral alliances with other services including hotels, as well as with other airlines.

  • PDF

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Medical Information Dynamic Access System in Smart Mobile Environments (스마트 모바일 환경에서 의료정보 동적접근 시스템)

  • Jeong, Chang Won;Kim, Woo Hong;Yoon, Kwon Ha;Joo, Su Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Recently, the environment of a hospital information system is a trend to combine various SMART technologies. Accordingly, various smart devices, such as a smart phone, Tablet PC is utilized in the medical information system. Also, these environments consist of various applications executing on heterogeneous sensors, devices, systems and networks. In these hospital information system environment, applying a security service by traditional access control method cause a problems. Most of the existing security system uses the access control list structure. It is only permitted access defined by an access control matrix such as client name, service object method name. The major problem with the static approach cannot quickly adapt to changed situations. Hence, we needs to new security mechanisms which provides more flexible and can be easily adapted to various environments with very different security requirements. In addition, for addressing the changing of service medical treatment of the patient, the researching is needed. In this paper, we suggest a dynamic approach to medical information systems in smart mobile environments. We focus on how to access medical information systems according to dynamic access control methods based on the existence of the hospital's information system environments. The physical environments consist of a mobile x-ray imaging devices, dedicated mobile/general smart devices, PACS, EMR server and authorization server. The software environment was developed based on the .Net Framework for synchronization and monitoring services based on mobile X-ray imaging equipment Windows7 OS. And dedicated a smart device application, we implemented a dynamic access services through JSP and Java SDK is based on the Android OS. PACS and mobile X-ray image devices in hospital, medical information between the dedicated smart devices are based on the DICOM medical image standard information. In addition, EMR information is based on H7. In order to providing dynamic access control service, we classify the context of the patients according to conditions of bio-information such as oxygen saturation, heart rate, BP and body temperature etc. It shows event trace diagrams which divided into two parts like general situation, emergency situation. And, we designed the dynamic approach of the medical care information by authentication method. The authentication Information are contained ID/PWD, the roles, position and working hours, emergency certification codes for emergency patients. General situations of dynamic access control method may have access to medical information by the value of the authentication information. In the case of an emergency, was to have access to medical information by an emergency code, without the authentication information. And, we constructed the medical information integration database scheme that is consist medical information, patient, medical staff and medical image information according to medical information standards.y Finally, we show the usefulness of the dynamic access application service based on the smart devices for execution results of the proposed system according to patient contexts such as general and emergency situation. Especially, the proposed systems are providing effective medical information services with smart devices in emergency situation by dynamic access control methods. As results, we expect the proposed systems to be useful for u-hospital information systems and services.

Translocation of Tolclofos-methyl from Ginseng Cultivated Soil to Ginseng (Panax ginseng C. A. Meyer) and Residue Analysis of Various Pesticides in Ginseng and Soil (토양 중 잔류된 Tolclofos-methyl의 인삼(Panax ginseng C. A. Meyer)에 대한 이행 및 잔류 특성)

  • Kim, Ji Yoon;Kim, Hea Na;Saravanan, Manoharan;Heo, Seong Jin;Jeong, Haet Nim;Kim, Jang Eok;Kim, Kwan Rae;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.3
    • /
    • pp.130-140
    • /
    • 2014
  • Recently, some of the previous studies reported that tolclofos-methyl is still exist in ginseng cultivated soil, even though it is has been banned for ginseng. Therefore, the current study was aimed to examine the levels of absorption and translocation of tolclofos-methyl from ginseng cultivated soil to ginseng root and leaf stem for the period of 1 year. For this study, ginseng plants were transplanted in pots and treated with $5.0mg\;kg^{-1}$ of tolclofos-methyl (50% WP). At the end of each interval periods (every three months) the samples (soil, roots and leaf stems) were collected and analyzed the absorption and translocation levels of tolclofos-methyl using gas chromatography and mass spectrometry (GC-MS). The limit of quantitation of tolclofos-methyl was found to be $0.02mg\;kg^{-1}$ and 70.0~120.0% recovery was obtained with coefficient of variation of less than 10% regardless of sample types. In this study, a considerable amount of translocation of tolclofos-methyl residues were found in soil (4.28 to $0.06mg\;kg^{-1}$), root (7.09 to $1.54mg\;kg^{-1}$) and leaf stem (0.79 to $0.69mg\;kg^{-1}$). The results show that the tolclofos-methyl was absorbted and translocated from ginseng cultivated soil to ginseng root and ginseng leaf stem and found to be decreased time-coursely. Secondly, we were also analyzed soil, root and leaf stems samples from Hongcheon, Cheorwon, Punggi and Geumsan by GC-MS/MS (172 pesticides), LC-MS/MS (74 pesticides). In this study, 43 different pesticides were detected ($0.01{\sim}7.56mg\;kg^{-1}$) in soil, root and leaf stem. Further, tolclofos-methyl was detected 4 times separately in root sample alone which is less ($0.01{\sim}0.05mg\;kg^{-1}$) than their maximum residual limit (MRL) in ginseng. Consequently, the results from both studies indicate the residues of tolclofos-methyl found in ginseng cultivated soil and ginseng ensuring their safety level. Moreover, long-term evaluations are needed in order to protect the soil as well as ginseng free from tolclofos-methyl residues.

The Content and Risk Assessment of Heavy Metals in Herbal Pills (유통 환제의 유해 중금속 함량 및 위해도 평가)

  • Lee, Sung-Deuk;Lee, Young-Ki;Kim, Moo-Sang;Park, Seok-Ki;Kim, Yeon-Sun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.375-387
    • /
    • 2012
  • The objective of this study is investigation of contamination levels and assessment of health risk effects of heavy metals in herbal pills. 31 Items and 93 samples were obtained for this investigation from major herbal medicine producing areas, herbal markets and on-line supermarkets from Jan to Jun in 2010. Inductively coupled plasma mass spectrometer method was conducted for the quantitative analysis of Pb, Cd and As. In addition, the mercury analyzer system was conducted for that of Hg without sample digestion. The average contents of heavy metals in samples were as follows : 0.87 mg/kg for Pb, 0.08 mg/kg for Cd, 2.87 mg/kg for As and 0.16 mg/kg for Hg, respectively. In addition, the average contents of heavy metals in different parts of plants, including cortex, fructus, herba, radix, seed, algae and others were 0.63 mg/kg, 3.94 mg/kg, 1.42 mg/kg, 1.05 mg/kg, 0.16 mg/kg, 22.31 mg/kg and 10.17 mg/kg, respectively. After the estimations of dietary exposure, the acceptable daily intake (ADI), the average daily dose (ADD), the provisional tolerable weekly intake (PTWI) and the relative hazard of heavy metals were evaluated. As the results, the relative hazards compared to PTWI in samples were below the recommended standard of JECFA as Pb 3.1%, Cd 0.9%, Hg 0.5%. Cancer risks through slope factor (SF) by Ministry of Environment Republic Korea and Environmental Protection Agency was $4.24{\times}10^{-7}$ for Pb and $3.38{\times}10^{-4}$ for As (assuming that the total arsenic content was equal to the inorganic arsenic). Based on our results, possible Pb-induced cancer risks in herbal pills according to parts used including cortex, fructus, herba, radix, seed, algae and others were $1.95{\times}10^{-7}$, $1.45{\times}10^{-6}$, $2.14{\times}10^{-7}$, $6.27{\times}10^{-7}$, $1.99{\times}10^{-8}$, $3.61{\times}10^{-7}$ and $9.64{\times}10^{-8}$, respectively. Possible As-induced cancer risks in herbal pills by parts used including cortex, fructus, herba, radix, seed, algae and others were $1.54{\times}10^{-5}$, $7.24{\times}10^{-5}$, $1.23{\times}10^{-4}$, $2.02{\times}10^{-5}$, $3.25{\times}10^{-6}$, $2.18{\times}10^{-3}$ and $5.67{\times}10^{-6}$ respectively. Taken together, these results indicate that the majority of samples except for some samples with relative high contents of heavy metals were safe.

Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid (용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험)

  • Back, Hyangmi;Kim, Youngsan;Yun, Sunhee;Heo, Uisung;Kim, Hosin;Ryu, Hyeonggi;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and $TSH^{125}I$ tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette $400{\mu}l$ of each liquid is dispensed to 8 tubes and $100{\mu}l$ of $TSH^{125}I$ tracer are dispensed to all of the tubes. From the prepared samples, $100{\mu}l$ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.

  • PDF