• Title/Summary/Keyword: 핵자료

Search Result 302, Processing Time 0.025 seconds

A Study on the Reproductive Cells in Testes of Microphysogobio yaluensis (돌마자(Microphysogobio yaluensis)의 정소 내 생식세포에 관한 연구)

  • Kim, Jae-Goo;Kim, Dong-Heui;Reu, Dong-Suck
    • Applied Microscopy
    • /
    • v.39 no.3
    • /
    • pp.245-252
    • /
    • 2009
  • The reproductive cells in testes of Microphysogobio yaluensis were investigated using light and electron microscopes. The testis of Microphysogobio yaluensis consisted of numerous testicular cysts contained synchronized cells. Sperms were full in testicular sacs of mature testes. Leydig cells were located among testicular cysts. The nucleus of primary spermatocytes was round and mitochondria were congregated in cytoplasm. The size of secondary spermatocyte was smaller than that of primary spermatocyte and the nucleus of a secondary spermatocyte was round or oval. In spermatids, the nucleus was round and electron-dense. In spermiogenesis, the nucleus was condensed and a flagellum started to be formed. The mitochondria were rearranged along the flagellum. The sperm had a round head, the acrosome was not found and a motile flagellum consisted of an axoneme with a typical 9+2 pattern of microtubule.

The effect of pre-service science teachers' experiences in nuclear physics research on their understanding of scientific inquiry process and career planning (핵물리 연구 참여 경험이 예비 과학교사의 과학 탐구과정의 본성에 대한 인식과 진로탐색에 미치는 영향)

  • Lee, In-Sun;Choi, Kyung-Hee;Hahn, In-Sik;Kim, Seon-Hwa;Lee, Hyun-Ju
    • Journal of The Korean Association For Science Education
    • /
    • v.29 no.5
    • /
    • pp.541-551
    • /
    • 2009
  • This study aimed to investigate the effect of pre-service science teachers' experiences in nuclear physics research on their understanding of scientific inquiry process and career planning. The thirty-week URP (Undergraduate Research Participation) program was designed with the participation of six pre-service science teachers. Data sources included in-depth interviews with the individual teachers, group discussions, participant observations with field notes over the weeks, journals and lab logs, etc. Results indicated that the teachers perceived the complex and repetitive nature of the science research process, the importance of scientists' creativity and collaboration, etc. Their typical impressions of scientists has also more or less changed. In addition, the teachers had opportunities to confirm their aptitude in physics and to explore their career options in physics-related fields.

A Study of Quality Control of Nuclear Medicine Counting System and Gamma Camera (핵의학 계측기기 및 감마카메라의 정도관리 연구)

  • 손혜경;김희중;정해조;정하규;이종두;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2001
  • Purpose: The purpose of this study was to investigate the current status of performing nuclear medicine quality control in korea and to test selected protocols of quality control of nuclear medicine counting system and gamma camera. Materials and Methods: Fifty three hospitals were included to investigate the current status of nuclear medicine quality control in korea. The precision of dose calibrator and thyroid uptake system was measured with Tc-99m 35.52 MBq for 2 minuets and Tc-99m 5.14 MBq for 10 sec every one minute, respectively. The sensitivity of CeraSPECT$^{TM}$ with low energy high resolution parallel hole collimator was measured using two cylindrical phantoms with 15 cm in diameter and 12 cm and 30 cm in heights containing Tc-99m. The correction factor for sensitivity of CeraSPECT$^{TM}$ was calculated using phantom data. The system planar sensitivity, uniformity, count rate and spatial resolution were measured for Varicam gamma camera with low energy high resolution parallel hole collimator using 140 keV centered 20% energy window, 256$\times$256 or 512$\times$512 matrix sizes. Results: The quality control of dose calibrator and well counter were showed poor performance status. On the other hand, The quality control of gamma camera and other systems were showed relatively good performance status. The results of precision of dose calibrator and thyroid uptake system was $\pm$1.4%(<$\pm$5%) and chi^2=29.7(>16.92), respectively. It showed that the sensitivity of CeraSPECT$^{TM}$ was higher in center slices compared with the edge slices. After correction of nonuniform sensitivities for patient data, it showed better results compare with prior to correction. System planar sensitivity of Varicam gamma camera was 4.39 CPM/MBq. The observed count rate at 20% loss was 102,407 counts/sec (head 1), 113,427 counts/sec (head 2), when input count rate was 81,926 counts/sec (head 1), 90,741 counts/sec (head 2). The spatial resolution without scatter medium were 8.16 mm of FWHM and 14.85 mm of FWTM. The spatial resolution with scatter medium were 8.87 mm of FWHM and 18.87 mm of FWTM. Conclusion: It is necessary to understand the importance of quality control and to perform quality control of nuclear medicine devices.vices.

  • PDF

Development of a Computer Code for Analyzing Time-dependent Nuclides Concentrations in the Multi-stage Continuous HLW Processing System (I) - Equilibrium Steady State - (다단계 연속후처리를 포함하는 핵주기공정의 핵종농도 동적분포 해석코드 계발(I) -정상 평형상태 해석모델-)

  • Oh, Se-Kee
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.262-264
    • /
    • 2000
  • 원자로 내에서 연소 중인 핵연료나 저장 또는 재처리 중인 사용후핵연료의 성분으로서 시설의 공정설계, 안전성분석 및 차폐설계에 중요한 입력자료가 되는 핵분열생성물질, 방사화생성물 및 악티나이드의 핵종 농도와 이에 대응하는 방사능 강도의 기기 별 시간변 화율을 해석할 수 있는 코드 개발할 목적으로 MULTISAMS 정상 평형상태 모델을 구현하였다. MULTISAMS 코드의 반응공정 모델은 서로 연결되어 있으며 내부에 방사성물질의 혼합유체가 순환하는 세 종류의 반응기(원자로, 열교환기 및 화학반응기) 계통에서 자연적 또는 설계에 의해 일어나는 현상으로서; 반응기 간의 물질 흐름; 각 반응기 내에서 방사성 붕괴, 변환, 이동과 중성자 흡수 및 핵분열; 외부로부터 특정 핵종의 유입혹은 유출을 고려한 시간종속 핵종농도보존방정식 이론에 근거한다. 코드의 유용성 및 신뢰성을 검증하기 위해 현재 개념설계가 진행 중인 AMBIDEXTER원자력 에너지시스템을 대상으로 ORIGEN2 계산과 비교하였다. 두 코드 간의 입력조건과 배경이론차이점 때문에 절대적 비교가 불가능하므로 단순이론의 중간매개코드로서 SAMS를 이용한 2단계 비교방법을 따랐다. 결론은 MULTISAMS는 ORIGEN2 계산의 수렴치와 근사하게 일치하면서 ORIGEN2 가 다룰 수 없는 핵주기 연속후처리공정의 정상가동 시 핵종 평형농도를 기기 별로 계산할 수 있다는 장점을 확인하였다.

  • PDF

BLR Density Variations of the Seyfert 1 Galaxies NGC 4151 and NGC 5548 (Seyfert 1 은하 NGC 4151, NGC 5548의 BLR 밀도 변화)

  • Son, Dong-Hoon;Hyung, Siek
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.495-501
    • /
    • 2004
  • Using numerous ground-based or space-based telescopes by many astronomers, AGN spectroscopic monitoring campaigns have been carried out over many years to study the variability of continua and emission lines. We investigate the SWP IUE spectra of a large aperture configuration for the Seyfert 1 galaxies NGC 4151 and NGC 5548. We estimate the BLR electron number densities and their variation from the line ratios of C III] 1909 to Si III] 1892. With the ratios of C IV 1550 to C III] 1909 which give us the information on the ionization parameter of BLR, we try to find the physical conditions of the BLR and activities of he super massive black hole surroundings. The BLR density variations scale as 4 and 8 for NGC 4151 and NGC 5548, respectively. Based on the BLR size and C III] line profiles, we found both black hole masses as about $10^7$ $M_{\odot}$.

Taxonomic position of Pedicularis hallaisanensis Hurusawa, an endemic plant of Mt. Halla (한라산 고유 한라송이풀의 분류학적 위치)

  • Cho, Won-Bum;Choi, Byoung-Hee
    • Korean Journal of Plant Taxonomy
    • /
    • v.41 no.2
    • /
    • pp.130-137
    • /
    • 2011
  • Pedicularis growing at Mt. Halla of Jeju Island is known as an endemic species of P. hallaisanensis Hurusawa. On the other hand, the plant is morphologically similar to P. amoena, P. spicata, and P. verticillata in gross morphology, so the taxonomic treatment of the taxon remains controversial. To clarify the taxonomic position of the plants, we examined external morphological characters and nuclear ribosomal DNA ITS sequences for P. hallaisanensis and its related species. The plants of Mt. Halla are clearly different from P. amoena and P. verticillata in the morphology of calyx lobes, the length of galea and lower lip, density of glandular hairs on plants, presences of the radical leaves after anthesis and molecular data. However, P. hallaisanensis is not clearly separated from P. spicata distributed in N. E. Asia on external morphological characters and DNA sequences of internal transcribed spacers. In this study, the morphological and molecular data suggested that P. hallaisanensis should be merged into the former species.

Development of groundwater level monitoring and forecasting technique for drought early warning (가뭄 예·경보를 위한 지하수위 모니터링 및 예측기법 개발)

  • Lee, Jeongju;Kim, Taeho;Chun, Genil;Kim, Hyeonsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.13-13
    • /
    • 2020
  • '20년 3월 현재 전국 3,502개 읍면동 중 73개 읍면동이 지하수를 상수원으로 급수 중이며, 48개 산업단지에서 지하수를 주 수원으로 사용 중이다. 또한 급수 소외지역의 물 공급을 위해 주로 사용되는 소규모수도시설 14,811개 중 12,073개(81.5%)는 지하수를 이용하고 있으며, 그 위치는 전국에 산재해 있다. 이처럼 지하수는 댐, 저수지 및 하천과 더불어 생·공용수의 중요한 수원이라 할 수 있다. 본 연구에서는 급수 소외지역의 주요 수원인 지하수위 현황을 이용한 가뭄 모니터링 및 전망 기법을 개발하고자 하였다. 국가 지하수관측망 중 10년 이상 장기 관측 자료를 보유한 253개 관측소의 일단위 관측자료를 기반으로, 과거 관측수위 분포를 핵밀도함수로 추정하고 Quantile Function을 이용해 현재 수위의 높고 낮은 정도를 Percentile 값으로 산정하였다. 관측소별 지하수위 Percentile은 티센망을 이용해 167개 시군별로 공간평균하고 Percentile의 범위에 따른 가뭄등급을 설정하여 지하수 가뭄 정도를 모니터링 할 수 있는 기법을 제시하였다. 또한 지하수 가뭄을 전망하기 위해 강수와 지하수위의 거시적인 응답특성을 이용하였다. 관측소별로 추정된 핵밀도함수의 누적확률을 표준정규분포의 Quantile로 변환하여 표준지하수지수I(Standardized Groundwater level Index, SGI)를 산정하고, 시군별로 공간을 일치시킨 1~12개월 지속기간별 표준강수지수(Standardized Precipitation Index, SPI)와의 상관관계를 이용해 NARX(nonlinear autoregressive exogenous) 인공신경망 예측모형을 구축하였다. 이를 통해 기상청 정량전망 강수량을 이용해 전국의 1~3개월 후 지하수 가뭄을 빠르게 전망할 수 있는 체계를 구축하고, 생·공용수 분야 국가 가뭄 예·경보의 미급수지역 가뭄현황 및 전망에 활용중이다.

  • PDF

MCNP 선원항 평가법에 의한 SMART 압력용기 중성자 조사량 예비평가

  • 김교윤;김하용;송재승
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.606-611
    • /
    • 1998
  • 330MWt 출력의 신형 원자로인 SMART(System integrated Mod씰w Advanced ReacTor)가 전기 생산뿐만 아니라 해수의 담수화를 위한 에너지 공급을 위해 한국원자력연구소에 의해 개발되고 있다. SMART의 원자로 압력용기에서의 중성자 조사량을 기존의 각분할법 코드 대신에 몬데칼로 수송 코드인 MCNP-4A를 이용하여 평가하였다. MCNP-4A에 의한 몬데 칼로 모사는 각분할법에 비해 핵 단면적 자료, 선원항, 그리고 기하학적 모델링의 문제로부터 야기되는 불확실성을 감소시킬 수 있을 뿐만 아니라 초기 개념 설계 단계에서 상세 노심 출력 분포 자료에 의존하지 않고 선원항을 평가할 수 있는 장점이 있다. 본 연구에서는 원자로 압력 용기 내부의 원자로 노심 및 다른 구조물을 포함하는 전체 원자로 구조에 대하여 몬테 칼로 모사를 적용하였다. 1단계에서는 임계도 계산에 의해 선원항으로 이용되는 원자로 노심내의 열 출력 분포를 평가하고, 2단계에서는 노심내의 열 출력 분포를 고정 선원으로 이용하여 압력 용기에서의 중성자 조사량을평가하였다. 그 결과 SMART 압력용기의 중성자 조사량은 규제 요건을 만족하는 것으로 나타났다.

  • PDF

An Analysis of Fast Critical Experiments Using JEF-1-Based 50-Group Constant Set (JEF-1의 50군 단면적에 의한 고속 임계실험 해석)

  • Kim, Jung-Do;Gil, Choong-Sup;Kim, Young-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.457-469
    • /
    • 1993
  • JEF-1-based 50-group cross section set for fast reactor calculations was generated using NJOY system. The set was then examined by analyzing measured integral quantities such as criticality and central reaction rate ratios for 27 fast critical assemblies. The calculated results using the new set were also compared with those of ENDF/B-IV or-V-based fast set. In general, the JEF-1-based set shows an improvement in predicting measured integral quantities in comparison with the previous set. With a few exceptions, JEF-1 results are comparable to those of ENDF/B-V.

  • PDF

Frequency of Micronuclei in Lymphocytes Following Gamma and Fast-neutron Irradiations (방사선 조사량에 따른 인체 정상 림파구의 미세핵 발생빈도)

  • Kim Sung-Ho;Cho Chul-Koo;Kim Tae-Hwan;Chung In-Yong;Yoo Seong-Yul;Koh Kyoung-Hwan;Yun Hyong-Geun
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.35-42
    • /
    • 1993
  • The dose response of the number of micronuclei in cytokinesis-blocked (CB) lymphocytes after in vitro irradiation with $\gamma$-rays and neutrons in the 5 dose ranges was studied for a heterogeneous population of 4 donors. One thousand binucleated cells were systematically scored for micronuclei. Measurements performed after irradiation showed a dose-dependent increase in micronuclei (MN) frequency in each of the donors studied. The dose-response curves were analyzed by a linear-quadratic model, frequencies per 1000 CB cells were ($0.31{\pm}0.049$)D+($0.0022{\pm}0.0002)D^2+(13.19{\pm}1.854) (r^2=1.000,\;X^2=0.7074,\;p=0.95$) following $\gamma$ irradiation, and ($0.99{\pm}0.528$)\;D+(0.0093{\pm}0.0047)\;D^2+(13.31{\pm}7.309)\;(r^2=0.996,\;X^2=7.6834,\;p=0.11) following neutrons irradiation (D is irradiation dose in cGy). The relative biological effectiveness (RBE) of neutrons compared with $\gamma$-rays was estimated by best fitting linear-quadratic model. In the micronuclei frequency between 0.05 and 0.8 per cell, the RBE of neutrons was $2.37{\pm}0.17$. Since the MN assay is simple and rapid, it may be a good tool for evaluating the $\gamma$-ray and neutron response.

  • PDF