• Title/Summary/Keyword: 핵부피

Search Result 52, Processing Time 0.029 seconds

Genetic Stock Identification of Spotted Flounder, Verasper variegatus from Yeocheun, Korea (범가자미에 대한 유전학적 동정)

  • KIM Kyung Kil;KIM Yoon;NAM Yoon Kwan;KIM Dong Soo
    • Journal of Aquaculture
    • /
    • v.6 no.3
    • /
    • pp.221-233
    • /
    • 1993
  • Cell size, DNA content, chromosome and PCR-based mitochondrial 12S rRNA gene analyses were conducted to obtain basic informations for genetic stock identification of spotted flounder (Verasper variegatus) from Yeocheun, Korea. The mean erythrocytic and nuclear volumes of spotted flounder were $211.10{\mu}m^3$ and $23.03{\mu}m^3$, respectively. The haploid DNA content of this species was 0.79 pg/cell which correspond to $46.5\%$ of carp and to $22.6\%$ of mammals. Spotted flounder had the 2n = 46 acrocentric chromosomes but no heteromorphic sex chromosomes was found. Mitochondrial DNA gene for 12S ribosomal RNA was amplified by polymerase chain reaction (PCR) and the PCR products were subjected to digestion with 15 restriction endonucleases. Restriction enzyme analyses revealed that Ava I, Mae II, Sma I and Xba I had one restriction site in the mitochondrial 12S rRNA gene segment of spotted flounder, while Mae I had two. Segments of 12S rRNA gene from mitochondria in spotted flounder were sequenced and compared with channel catfish and human as controls. The 12S rRNA gene of this species was more similar to that of channel catfish than to human's.

  • PDF

Effect of Dissolved Oxygen on Occurrence of Tunic Softness Syndrome in Sea Squirt Halocynthia roretzi, Tongyeong, South Coast of Korea (멍게의 물렁증 발생에 미치는 용존산소의 영향)

  • Shin, Yun Kyung;Park, Jung Jun;Jun, Je Cheon;Myeong, Jeong-In;Yang, Sung Jin
    • Korean Journal of Environmental Biology
    • /
    • v.31 no.3
    • /
    • pp.204-212
    • /
    • 2013
  • This study analyzed the occurrence of tunic softness, survival rate, metabolic rate and histopathologic changes arising from the effect of hypoxic environment in order to find the causes of occurrences of tunic softness, which manifests as the key phenomenon of mass mortality of Halocynthia roretzi. Regarding the survival of H. roretzi with reduction in dissolved oxygen, all the entities died on the 4th day of exposure to the dissolved oxygen concentration of $2mg\;L^{-1}$ while 50% mortality was observed on the 5th day of exposure to the dissolved oxygen concentration of $3mg\;L^{-1}$. Therefore the 5 days-$LC_{50}$ was found to be $3.55mg\;L^{-1}$ (1.86~$4.96mg\;L^{-1}$). However, occurrence of tunic softness was not observed during the period of exposure to low oxygen concentration. The oxygen consumption rate significantly decreases at the dissolved oxygen concentration of less than $5mg\;L^{-1}$ in comparison to the control group. Therefore, it is presumed that H. roretzi controls the respiration rate for prescribed period of time when exposed to hypoxic environment. Regarding the histopathologic changes in the gill, digestive gland and cyst of H. roretzi due to hypoxic environment, necrosis of epithelial layer, in filtration of blood cells, and condensation of nucleus that compose each of the organs were observed. Regarding morphological changes, the decrease in volume with shrinking of the tunic, discoloration of the internal organs and necrosis of gill and hepatopancreas were observed.

Effect of Oral Administration of Houttuynia Cordata Extract on Benign Prostatic Hyperplasia (전립선비대증의 어성초추출물에 의한 경구투여 효과)

  • Song, Won-Yeong;Choi, Jeong-Hwa
    • Journal of Life Science
    • /
    • v.29 no.6
    • /
    • pp.705-711
    • /
    • 2019
  • Benign prostatic hyperplasia (BPH) is the most common urogenital disorder in men, benign tumor and is a typical disease deteriorating the quality of old men's lives, and its prevalence increases with age. Though the molecular pathogenesis of BPH has not yet been clearly revealed, it is known that the variation and aging of the endocrine including sex hormone may cause BPH. Especially the hypertrophy of the prostate cell by the formation of the excessive dihydrotestosterone (DHT) is estimated to cause BPH. If testosterone exists excessively in blood, a lot of DHT is produced in prostate by $5{\alpha}-reductase$. Thus, in this study we tried to analyze haematological change and histopathological change by using the model rat with BPH caused by hypodermic injection of testosterone to prove the effect of Houttuynia cordata extracts on BPH. Rats were divided into four experimental groups: no treatment group (N), the testosterone injection and D.W treatment group (DO), the testosterone injection and Houttuynia cordata treatment group (HO) and testosterone injection and finasteride treatment group (FO). Prostate weight, volume and weight ratio in the HO and FO groups were significantly lower than the DO group. Testosterone and DHT levels in the HO group were significantly lower than the DO group. The HO and FO groups showed trophic symptoms and were lined by flattened epithelial cells, thus, the stromal proliferation is relatively low as compared to the DO group. These results suggest that Houttuynia cordata may control benign prostatic hyperplasia.

Improvement in Regional Contractility of Myocardium after CABG (관상동맥 우회로 수술 환자에서 심근의 탄성도 변화)

  • Lee, Byeong-Il;Paeng, Jin-Chul;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.224-230
    • /
    • 2005
  • Purpose: The maximal elastance ($E_{max}$) of myocardium has been established as a reliable load-independent contractility index. Recently, we developed a noninvasive method to measure the regional contractility using gated myocardial SPECT and arterial tonometry data. In this study, we measured regional $E_{max}(rE_{max}$ in the patients who underwent coronary artery bypass graft surgery (CABG), and assessed its relationship with other variables. Materials and Methods: 21 patients (M:F=17:4, $58{\pm}12$ y) who underwent CABG were enrolled. $^{201}TI$ rest/dipyridamole stress $^{99m}Tc$-sestamibi gated SPECT were performed before and 3 months after CABG. For 15 myocardial regions, regional time-elastance curve was obtained using the pressure data of tonometry and the volume data of gated SPECT. To investigate the coupling with myocardial function, preoperative regional $E_{max}$ was compared with regional perfusion and systolic thickening. In addition, the correlation between $E_{max}$ and viability was assessed in dysfunctional segments (thickening <20% before CABG). The viability was defined as improvement of postoperative systolic thickening more than 10%. Results: Regional $E_{max}$ was slightly increased after CABG from $2.41{\pm}1.64 (pre)\;to\;2.78{\pm}1.83 (post)$ mmHg/ml. $E_{max}$ had weak correlation with perfusion and thickening (r=0.35, p<0.001). In the regions of preserved perfusion (${\geq}60%$), $E_{max}$ was $2.65{\pm}1.67$, while it was $1.30{\pm}1.24$ in the segments of decreased perfusion. With regard to thickening, $E_{max}$ was $3.01{\pm}1.92$ mmHg/ml for normal regions (thickening ${geq}40%$), $2.40{\pm}1.19$ mmHg/ml for mildly dysfunctional regions (<40% and ${\geq}20%$), and $1.13{\pm}0.89$ mmHg/ml for severely dysfunctional regions (<20%). $E_{max}$ was improved after CABG in both the viable (from $1.27{\pm}1.07\;to\;1.79{\pm}1.48$ mmHg/ml) and non-viable segments (from $0.97 {\pm}0.59\;to\;1.22{\pm}0.71$ mmHg/ml), but there was no correlation between $E_{max}$ and thickening improvements (r=0.007). Conclusions: Preoperative regional $E_{max}$ was relatively concordant with regional perfusion and systolic thickening on gated myocardial SPECT. In dysfunctional but viable segments, $E_{max}$ was improved after CABG, but showed no correlation with thickening improvement. As a load-independent contractility index of dysfunctional myocardial segments, we suggest that the regional $E_{max}$ could be an independent parameter in the assessment of myocardial function.

Development and Performance Test of Preamplifier and Amplifier for Gamma Probe (감마프로브용 전단증폭기와 주증폭기의 개발과 성능 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Lee, Jong-Doo;Kwon, Soo-Il
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.1
    • /
    • pp.100-109
    • /
    • 1999
  • Purpose: Preamplifier and amplifier are very important parts for developing a portable counting or imaging gamma probe. They can be used for analyzing pulses containing energy and position information for the emitted radiations. The commercial Nuclear Instrument Modules (NIMs) can be used for processing these pulses. However, it may be improper to use NIMs in developing a portable gamma probe, because of its size and high price. The purpose of this study was to develop both preamplifier and amplifier and measure their performance characteristics. Materials and Methods: The preamplifier and amplifier were designed as a charge sensitive device and a capacitor resistor-resistor capacitor (CR-RC) electronic circuit, respectively, and they were mounted on a print circuit board (PCB). We acquired and analyzed energy spectra for Tc-99m and Cs-137 using both PCB and NIMs. Multichannel analyzer (Accuspec/A, Canberra Industries Inc., Meriden Connecticut, U.S.A) and scintillation detectors (EP-047(Bicron Saint-Gobain/Norton Industrial EP-047 (Ceramics Co., Ohio, U.S.A) with $2"{\times}2"$ NaI(T1) crystal and R1535 (Hamamatsu Photonics K.K., Electron Tube Center, Shizuoka-ken, Japan) with $1"{\times}1"$ NaI(T1) crystal were used for acquiring the energy spectra. Results: Using PCB, energy resolutions of EP-047 detectors for Tc-99m and Cs-137 were 12.92% and 5.01%, respectively, whereas R1535 showed 13.75% and 5.19% of energy resolution. Using the NIM devices, energy resolutions of EP-047 detector for Tc-99m and Cs-137 were measured as 14.6% and 7.58%, respectively. However, reliable energy spectrum of R1535 detector could not be acquired, since its photomultiplier tube (PMT) requires a specific type of preamplifier. Conclusion: We developed a special preamplifier and amplifier suitable for a small sized gamma probe that showed good energy resolutions independent of PMT types. The results indicate that the PCB can be used in developing both counting and imaging gamma probe.

  • PDF

Effects of Deer Antler on the Regeneration of Peripheral Nerves; About Sprout Formation of Experimentally Transected Sciatic Nerves in Rat (말초신경의 재생에 대한 녹용의 효과; 랫드에서 실험적 절단 좌골신경의 Sprout 형성에 관해)

  • Chang, Byung-Joon;Cho, Ik-Hyun;Choi, Hye-Young;Won, Hui-Young;Park, Chang-Hyun;Bae, Chun-Sik;Choe, Nong-Hoon
    • Applied Microscopy
    • /
    • v.32 no.1
    • /
    • pp.67-80
    • /
    • 2002
  • This study was carried out to investigate the effects of deer antler extract on the regeneration of peripheral nerves. Sprague-Dawley male rats weighing about 300 gm were fed deer antler extract for 1, 2, and 3 weeks per oral (1.5 ml/100 gm B.W.), respectively, once a day and transected both sides of sciatic nerve of each leg. After keeping for 6 hours, sciatic nerves taken from proximal part of transected region were treated with conventional transmission electron microscopical method and then observed with electron microscope. The results obtained were summarized as follows; 1. Sciatic nerves of normal control group were not showing any sprouts and electron dense axolemmal projections were frequently observed. 2. Sciatic nerves of saline treated groups were showing axonal sprouts at the nodes of Ranvier. The length of them was usually short, and numerous vesicles, vacuoles and organelles including neurofilament were contained. The number of nodes of Ranvier containing sprouts from 100 longitudinal sectioned nerve fibers was 29 (29%) in 1 week treated group, 32 (32%) in 2 weeks treated group, and 30 (30%) in 3 weeks treated group, respectively. 3. Sciatic nerves of deer antler treated groups were showing axonal sprouts at the node of Ranvier as well. Although most of the sprouts were short, some sprouts of 2 weeks and 3 weeks treated groups were quite long. Sprouts usually contained numerous vesicles, vacuoles and cell organelles such as neurofilaments and mitochondria. The number of nodes of Ranvier containing sprouts from 100 longitudinal sectioned nerve fibers was 38 (38%) in 1 week treated group, 46 (46%) in 2 weeks treated group, and 48 (48%) in 3 weeks treated group respectively. The results described above explain pretreatment of deer antler extract improves the sprout formation of transected sciatic nerves, and then it suggests deer antler may be effective for the regeneration of peripheral nerves.

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

CComparative evaluation of the methods of producing planar image results by using Q-Metrix method of SPECT/CT in Lung Perfusion Scan (Lung Perfusion scan에서 SPECT-CT의 Q-Metrix방법과 평면영상 결과 산출방법에 대한 비교평가)

  • Ha, Tae Hwan;Lim, Jung Jin;Do, Yong Ho;Cho, Sung Wook;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • Purpose The lung segment ratio which is obtained through quantitative analyses of lung perfusion scan images is calculated to evaluate the lung function pre and post surgery. In this Study, the planar image production methods by using Q-Metrix (GE Healthcare, USA) program capable of not only quantitative analysis but also computation of the segment ratio after having performed SPECT/CT are comparatively evaluated. Materials and Methods Lung perfusion scan and SPECT/CT were performed on 50 lung cancer patients prior to surgery who visited our hospital from May 1, 2015 to September 13, 2016 by using Discovery 670(GE Healthcare, USA) equipment. AP(Anterior Posterior)method that uses planar image divided the frontal and rear images into three rectangular portions by means of ROI tool while PO(Posterior Oblique)method computed the segment ratio by dividing the right lobe into three parts and the left lobe into two parts on the oblique image. Segment ratio was computed by setting the ROI and VOI in the CT image by using Q-Metrix program and statistically analysis was performed with SPSS Ver. 23. Results Regarding the correlation concordance rate of Q-Metrix and AP methods, RUL(Right upper lobe), RML(Right middle lobe) and RLL(Right lower lobe) were 0.224, 0.035 and 0.447. LUL(Left upper lobe) and LLL(Left lower lobe) were found to be 0.643 and 0.456, respectively. In the PO method, the right lobe were 0.663, 0.623 and 0.702, respectively, while the left lobe were 0.754 and 0.823. When comparison was made by using the Paired sample T-test, Right lobe were $11.6{\pm}4.5$, $26.9{\pm}6.2$ and $17.8{\pm}4.2$, respectively in the AP method. Left lobe were $28.4{\pm}4.8$ and $15.4{\pm}5.6$. The right lobe of PO had values of $17.4{\pm}5.0$, $10.5{\pm}3.6$ and $27.3{\pm}6.0$, while the left lobe had values of $21.6{\pm}4.8$ and $23.1{\pm}6.6$, thereby having statistically significant difference in comparison to the Q-Metrix method for each of the lobes (P<0.05). However, there was no statistically significant difference in Right middle lobe (P>0.05). Conclusion The AP method showed low concordance rate in correlation with the Q-Metrix method. However, PO method displayed high concordance rate overall. although AP method had significant differences in all lobes, there was no significant difference in Right middle lobe of PO method. Therefore, at the time of production of lung perfusion scan results, utilization of Q-Metrix method of SPECT/CT would be useful in computation of accurate resultant values. Moreover, it is deemed possible to expect obtain more practical sectional computation result values by using PO method at the time of planar image acquisition.

Effects of Anti-thyroglobulin Antibody on the Measurement of Thyroglobulin : Differences Between Immunoradiometric Assay Kits Available (면역방사계수법을 이용한 Thyroglobulin 측정시 항 Thyroglobulin 항체의 존재가 미치는 영향: Thyroglobulin 측정 키트에 따른 차이)

  • Ahn, Byeong-Cheol;Seo, Ji-Hyeong;Bae, Jin-Ho;Jeong, Shin-Young;Yoo, Jeong-Soo;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ha, Sung-Woo;Sohn, Jin-Ho;Lee, In-Kyu;Lee, Jae-Tae;Kim, Bo-Wan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.252-256
    • /
    • 2005
  • Purpose: Thyroglobulin (Tg) is a valuable and sensitive tool as a marker for diagnosis and follow-up for several thyroid disorders, especially, in the follow-up of patients with differentiated thyroid cancer (DTC). Often, clinical decisions rely entirely on the serum Tg concentration. But the Tg assay is one of the most challenging laboratory measurements to perform accurately owing to antithyroglobulin antibody (Anti-Tg). In this study, we have compared the degree of Anti-Tg effects on the measurement of Tg between availale Tg measuring kits. Materials and Methods: Measurement of Tg levels for standard Tg solution was performed with two different kits commercially available (A/B kits) using immunoradiometric assay technique either with absence or presence of three different concentrations of Anti-Tg. Measurement of Tg for patient's serum was also performed with the same kits. Patient's serum samples were prepared with mixtures of a serum containing high Tg levels and a serum containg high Anti-Tg concentrations. Results: In the measurements of standard Tg solution, presence of Anti-Tg resulted in falsely lower Tg level by both A and B kits. Degree of Tg underestimation by h kit was more prominent than B kit. The degree of underestimation by B kit was trivial therefore clinically insignificant, but statistically significant. Addition of Anti-Tg to patient serum resulted in falsely lower Tg levels with only A kit. Conclusion: Tg level could be underestimated in the presence of anti-Tg. Anti-Tg effect on Tg measurement was variable according to assay kit used. Therefore, accuracy test must be performed for individual Tg-assay kit.