• Title/Summary/Keyword: 합성바닥슬래브

Search Result 42, Processing Time 0.022 seconds

Analytical Study on Effect of Floor Slab for Progressive Collapse Resistant Capacity of Steel Moment Frames (철골모멘트골조의 연쇄붕괴저항성능에 대한 바닥슬래브의 효과에 관한 해석적 연구)

  • Kim, Seonwoong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.1
    • /
    • pp.27-35
    • /
    • 2014
  • In this study, an improved energy-based nonlinear static analysis method are proposed to be used for more accurate evaluation of progressive collapse potential of steel moment frames by reflecting the contribution of a double-span floor slab. To this end, the behavior of the double-span floor slab was first investigated by performing material and geometric nonlinear finite element analysis. A simplified energy-absorbed analytical model by idealizing the deformed shape of the double-span floor slab was developed. It is shown that the proposed model can easily be utilized for modeling the axial tensile force and strain energy response of the double-span floor slab under the column-removal scenario.

Bending Behaviour of Composite Slab Using a New-Shaped Steel Deck Plate and Expanded Metal (신형 데크플레이트와 철판망을 적용한 합성슬래브의 휨 거동)

  • Kim, Myoung Mo;Eom, Chul Hwan
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.4 s.65
    • /
    • pp.403-412
    • /
    • 2003
  • The composite metal deck plate system has been widely used for office structures. Recently, however, the flat deck plate has been developed to apply the composite slab system to residential structures. Reduction in construction cost and time can be expected by using expanded metal instead of wire mesh as crack control reinforcements. This study proposed a composite slab system composed of a new-shaped steel deck plate and expanded metal. Twelve specimens were tested to evaluate the structural performance of the new composite slab system. The test results were summarized mainly in terms of maximum load carrying capacity and failure behaviors of each specimen.

The Composite Action of Composite Truss Using H-Shaped Section Steel (H형강을 사용한 합성트러스의 합성효과)

  • Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.637-646
    • /
    • 2009
  • The composite actions of truss beams and floor slabs are not reflected on the design of the truss beam in domestic practice. In this research, basic experiments were conducted on a composite truss with the top and bottom chord members consisting of the H-shaped members. The tests were performed to evaluate the mechanical behaviors of the composite truss on the effects with the shear studs and without them. The specimens consisted of the steel truss and non-composite and composite trusses, and one-point-concentrated loading at the center and equivalent loading were monotonically applied. The composite effects were experimentally identified in the composite trusses using the shear stud connectors.

Effects of Composite Floor Slab on Seismic Performance of Welded Steel Moment Connections (철골모멘트 용접접합부의 내진성능에 미치는 합성슬래브의 영향)

  • Lee, Cheol Ho;Jung, Jong Hyun;Kim, Jeong Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.385-396
    • /
    • 2014
  • Traditionally, domestic steel design and construction practice has provided extra shear studs to moment frame beams even when they are designed as non-composite beams. In the 1994 Northridge earthquake, connection damage initiated from the beam bottom flange side was prevalent. The upward moving of the neutral axis due to the composite action between steel beam and floor deck was speculated to be one of the critical causes. In this study, full-scale seismic testing was conducted to investigate the side effects of the composite action in steel seismic moment frames. The specimen PN700-C, designed following the domestic connection and floor deck details, exhibited significant upward shift of the neutral axis under sagging (or positive) moment, thus producing high strain demand on the bottom flange, and showed a poor seismic performance because of brittle fracture of the beam bottom flange at 3% story drift. The specimen DB700-C, designed by using RBS connection and with the details of minimized floor composite action, exhibited superior seismic performance, without experiencing any fracture or concrete crushing, almost identical to the bare steel counterpart (specimen DB700-NC). The results of this study clearly indicate that the beams and connections in seismic steel moment frames should be constructed to minimize the composite action of a floor deck if possible.

An Experimental Study on the Flexural Behavior of Composite Steel Deck Slab with Bored Openings (천공 개구부가 있는 합성슬래브의 휨거동에 관한 실험적 연구)

  • Eom, Chul Hwan;Kim, Hee Cheul;Park, Jin Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.5
    • /
    • pp.607-614
    • /
    • 2006
  • The composite metal deck plate system has been widely used of late for office structures. However, composite floor decks are bored imprudently for installation in building equipment. In this study, experimental investigations of bored composite steel deck slabs were performed to evaluate the flexural capacity of each specimen. The variables set were the shapes and positions of the openings in the composite slabs. The results were analyzed in the form of load-displacement graphs and with respect to the ductility and energy dissipation capacity ofeach specimen to evaluate its structural capacity.

A Study on Modifacation of a Prediction Equation for the Natural Frequency of a Composite Deck Floor System through the Simplification of a section Transformation (합성데크 플레이트 바닥구조의 단면환산 단순화를 통한 고유진동수 예측식의 보정에 관한 연구)

  • Im, Ji Hoon;Park, Jin Young;Hong, Won Kee;Kim, Hee Cheul
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.549-556
    • /
    • 2002
  • The natural frequency of a system is commonly used in evaluating the serviceability condition of a floor. However. the current equations recommended in many building codes do not consider the various material types of a slab system; thus. different results are observed. Likewise. the transformation of a slab section required to predict the natural frequency of a composite deck plate is complicated. due to the varying shapes of the deck plates. Therefore. a new and simplified method of transforming a composite slab into an equivalent concrete slab is proposed. he modified vibration prediction equation was proposed based on the current vibration prediction equation recommended by LRFD. Compared to other equations. it is the closest to those obtained from experiments. The modified equation provides about 14.3% more accurate results than that recommended by LRFD. Likewise. the applicability of the proposed equation to other types of composite deck plate floor system was validated.

Analytical and Experimental Studies on Partially Composite of Steel-Plate Girder Bridges Using Slab Anchors (바닥판 앵커를 사용한 플레이트거더교의 부분합성에 관한 해석 및 실험 연구)

  • Han, Sang Yun;Park, Nam Hoi;Yoon, Ki Young;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.3 s.70
    • /
    • pp.325-332
    • /
    • 2004
  • Cross sections of steel-plate girder bridges are divided into three cross sections of non-composite, partially composite, and fully composite sections, according to their composite characteristics. The Korean provision for the partially and fully composite sections specifies general usage of the stud of shear connectors, whereas the one for the non-composite section specifies empirical usage of slab anchors. However, the actual behavior of the cross sections of steel-plate girder bridges using slab anchors is close not to the non-composite action, but to the partially composite action. Therefore analytical and experimental studies on partial composites of steel-plate girder bridges using slab anchors are performed in this study. Intial stiffness of the slab anchor is obtained by the experimental study for the first time, and the composite characteristic of simple-span and two-span continuous steel-plate girder bridges is investigated by the finite element analyses for the second time. Based on the obtained initial stiffness, the reduction effect of tensile stresses in the concrete-slab on the intermediate support of the continuous bridge is also considered herein.

Experimental Study on the Cracking Loads of LB-DECKs with Varied Cross-Section Details (단면 상세가 변화된 LB-DECK의 균열하중에 대한 실험적 연구)

  • Youn, Seok-Goo;Cho, Gyu-Dae
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.657-665
    • /
    • 2011
  • LB-DECK, a precast concrete panel type, is a permanent concrete deck form used as a formwork for cast-in-place concrete pouring at bridge construction site. LB-DECK consists of 60 mm thick concrete slab and 125 mm height Lattice-girders partly embedded in the concrete slab. These decks have been applied to the bridges, which girder spacings are short enough to resist longitudinal cracking caused by construction loads. This paper presents experimental research work conducted to evaluate the cracking load of LB-DECKs designed for long span bridge decks. Twenty four non-composite beams and four composite beams are fabricated considering three design variables of thickness of concrete slab, height of lattice-girder, and diameter of top-bar. Static loads controlled by displacements are applied to test beams to obtain cracking and ultimate loads. Vertical displacements at the center of beams, strains of top-bar, crack propagation in concrete slab, and final failure modes are carefully monitored. The obtained cracking loads are compared to the analytical results obtained by elastic analyses. Long-term analyses using age-adjusted effective modulus method (AEMM) are also conducted to investigate the effects of concrete shrinkage on the cracking loads. Based on the test results, the tensile strength and the design details of LB-DECKs are discussed to prevent longitudinal cracking of long span bridge decks.

Effect of Constructional Deflection of Composite Beam on Concrete Ponding in Metal Deck Slab (합성보의 시공중 처짐이 합성데크슬래브의 콘크리트 고임에 미치는 영향)

  • Kim, Young-Chan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.4
    • /
    • pp.99-106
    • /
    • 2002
  • In the composite deck system, beams and deck plates deflect during construction. This lens-shaped deflection may cause problems in the serviceability of a building. Therefore, it should be compensated to be level. Several methods for leveling of floor slab are available, such as (1) increasing stiffness of structural members, (2) propping floor system, (3) cambering beams, (4) pouring additional concrete. In this study, additional weight and volume of concrete for level compensation are examined for various size of floors.

The Experimental Study of Full-scale Centrifugal Formed High Strength Concrete Prismatic Beam(CFPB) Composited with Deck Slab (상부 슬래브와 합성된 원심성형으로 제작된 초고강도 각형보의 실험연구 )

  • Doo-Sung Lee;Sung-Jin Kim;Jeong-Hoi Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.19-29
    • /
    • 2023
  • An ultra-high strength prestressed prismatic beam of 100 MPa in compressive strength was developed by increasing the watertightness of concrete by utilizing centrifugal molding processes without adding expensive admixtures such as silica fume. The ultra-high strength centrifugal shaped square beam installed on the wall is composited with the upper slab concrete and then subjected to a service load. Horizontal shear stress is generated by bending between the centrifugal molding beam and the floor plate, which causes the beam and floor plate to perform composite behavior through shear connections such as studs and rebars. In this study, a flexural load test was performed on a mock-up specimen that was synthesized by fabricating an RC slab on top of a 100 MPa-class centrifugal shaped beam produced at the factory. proven reliability.