• Title/Summary/Keyword: 함수비 특성곡선

Search Result 176, Processing Time 0.034 seconds

The Estimated Drying Schedules of Larix leptolepis and Pinus koraiensis (낙엽송과 잣나무재의 추정건조(推定乾燥)스케쥴)

  • Park, Jong-Su;Kim, Su-Chang
    • Journal of Forest and Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.50-60
    • /
    • 1995
  • This study was carried out to estimate drying schedules of Larix Leptolepis and Pinus koraiensis by oven-drying at $100^{\circ}C$ which aimed to elucidate the characteristics such as current moisture content, drying process. initial check, collapse, internal check and drying rate during drying following each board thickness (2, 3. 4, 5, 6cm). the results were summerized as follows; Current moisture content of each board showed a rapid drying curve with the decrease of board thickness. At 20% moisture content, the drying rate of Larix leptolepis was higher than that of Pinus koraiensis and the drying rate of boards was lower with the increase of board thickness. From the estimated drying schedules. the initial conditions of drying of Larix leptolepis had to be milder than those of Pinus koraiensis and the boards thickness of 5cm, 6cm had to be most mild conditions.

  • PDF

Development of $ZrO_2/Nafion^R$M composite membranes for PEMFC operation at high temperature/low humidity (고온/저가습 PEMFC운전을 위한 $ZrO_2/NafionM$ 복합막 개발)

  • Park, Ki-Tae;Jung, Un-Ho;Choi, Dong-Woong;Chun, Kook;Lee, Hyang-Mee;Kim, Sung-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.399-402
    • /
    • 2006
  • 현재까지 연료전지 전해질 막으로는 Nafion으로 잘 알려져 있는 perfluorosulfonic acid(PFSA)막이 주를 이루고 있다. 이 막들은 $80^{\circ}C$ 이하의 낮은 온도의 연료전지에서 가장 좋은 성능을 보인다. PFSA 막들은 탄소-불소로 이루어진 사슬의 특성상 산화, 환원의 조건에서도 뛰어난 안정성을 보이며 이온 전도도가 0.1S/cm 이상으로 기존에 알려진 전해질 막들 중 가장 우수한 성능을 나타낸다. 하지만 연료전지의 작동온도가 $100^{\circ}C$ 이상의 높은 온도에서 는 막에 존재하던 수분이 제거되면서 수소이온 전도도가 떨어지며 기계적 물성도 떨어지는 문제점을나타낸다. $100^{\circ}C$ 이상의 온도에서 연료전지를 작동시키면 양쪽의 전극에서 일어나는 촉매반응의 속도가 향상되며, 물의 끓는점 이상에서 작동되므로, 전지 내에서 다양한 상을 고려하지 않고 기화된 물만을 고려하여 설계를 할 수가 있다. 따라서 최근 이러한 고온/저가습 운전을 위 한 전해질 막의 개발을 위해 기존의 Nafion 막에 전도성 무기 입자를 도입하는 연구들이 활발히 진행되고 있다. 본 연구에서는 전도성 무기 입자로서 $ZrO_2$나노입자를 합성하고, 이를 상용 10 wt.% Nafion 용액에 분산하여 solution casting 방법을 통해 $61{\mu}m$ 두께의 유기-무기 복합막을 제조하였다. 제조한 유기-무기 복합막의 성능 평가를 위하여 함수율, 이온 전도도, 당량무게 및 단위 전지를 이용한 전류-전압 곡선을 측정하여 상용 Nafion 112 막과 비교해 보았다. $ZrO_2$ 입자는 전도성이며 동시에 친수성을 나타내기 때문에 상용 막에 비하여 함수율 및 수소이온 전도도가 우수하게 나타났다. 복합막의 이러한 물성은 $100^{\circ}C$이상의 고온에서 전해질 막 내의 물 관리를 용이하게 한다. 단위 전지 운전 온도 $130^{\circ}C$, 상대습도 37%의 운전 조건에서도 상당히 우수한 전지 성능을 보임에 따라 고온/저가습 조건에서 상용 Nafion 112 막보다 우수한 막 특성을 나타냄을 확인하였다.

  • PDF

Analyis of stormwater and runoff characteristics in Anseongcun basin using HEC-HMS (HEC-HMS을 이용한 안성천 유역의 강우 유출 특성 분석)

  • Hwang, Byung-Gi;Yang, Seung-Bin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.17-24
    • /
    • 2018
  • The HEC-HMS model was applied to identify the rainfall-runoff processes for the Anseongchun basin, where the lower part of the stream has been damaged severely by tropical storms in the past. Modeling processes include incorporating with the SCS-CN model for loss, Clark's UH model for transformation, exponential recession model for baseflow, and Muskingum model for channel routing. The parameters were calibrated through an optimization technique using a trial and error method. Sensitivity analysis after calibration was performed to understand the effects of parameters, such as the time of concentration, storage coefficient, and base flow related constants. Two storm water events were simulated by the model and compared with the corresponding observations. Good accuracy in predicting the runoff volume, peak flow, and the time to peak flow was achieved using the selected methods. The results of this study can be used as a useful tool for decision makers to determine a master plan for regional flood control management.

Form-finding of Free-form Membrane Structure based on Geometrically Non-linear Analysis and Interface method (기하학적 비선형해석을 이용한 비정형 막 구조물의 형상탐색과 인터페이스 기법)

  • Kim, Jee-In;Na, Yoo-Mi;Kang, Joo-Won;Lee, Jae-Hong
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.1
    • /
    • pp.77-85
    • /
    • 2012
  • The membrane structure maintains stable form by giving initial tension to ductile membrane and increasing the stiffness of exterior that is much adopted in the large span spatial structure by making its thickness thin. This kind of membrane structure has characteristic that can express free-form curve, so the selection of structural form is very important. So, this paper proposes the expression of free-form surface based on NURBS basis function and the finite element method considering geometrical nonlinearity for the deduction of large deformation result. Also, for minimizing the approximation of the surface that is derived from the form-finding result, the interface method that change finite element mesh to NURBS is proposed. So, the optimum surface of free-form membrane is derived.

Temperature-Dependency Thermal Properties and Transient Thermal Analysis of Structural Frames Exposed to Fire (온도의존성 열특성 계수를 고려한 화재에 노출된 철근콘크리트 골조의 해석적 연구)

  • Han, Byung-Chan;Kwon, Young-Jin;Kim, Jae-Hwan;Shin, Yeong-Soo;Choi, Eun-Gyu
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.283-292
    • /
    • 2007
  • A research projects is currently being conducted to develop a nonlinear finite element analysis methods for predicting the structural behavior of reinforced concrete frame structures, exposed to fire. As part of this, reinforced concrete frames subjected to fire loads were analyzed using the nonlinear finite-element program DIANA. Two numerical steps are incorporated in this program. The first step carries out the nonlinear transient heat flow analysis associated with fire and the second step predicts the structural behavior of reinforced concrete frames subjected to the thermal histories predicted by first step. The complex features of structural behavior in fire conditions, such as thermal expansion, plasticity, cracking or crushing, and material properties changing with temperature are considered. A concrete material model based on nonlinear fracture mechanics to take cracking into account and plasticity models for concrete in compression and reinforcement steel were used. The material and analytical models developed in this paper are verified against the experimental data on simple reinforced concrete beams. The changes in thermal parameters are discussed from the point of view of changes of structure and chemical composition due to the high temperature exposure. Although, this study considers codes standard fire for reinforced concrete frame, any other time-temperature relationship can be easily incorporated.

Experimental Studies of Shearing Properties on Compacted Nakdong River Silty Sands under Unconsolidated Undrained Condition (비압밀비배수조건에서 다져진 낙동강 실트질 모래의 전단거동에 대한 실험적 연구)

  • Khin, Swe Tint;Kim, Young-Su
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.57-62
    • /
    • 2010
  • In this study, the effect of different silt contents on the shear characteristics of silty sands was evaluated. Two series of triaxial compression tests were performed on the cylindrical specimens of compacted Nakdong river sand with 10% and 30% silt contents under unconsolidated undrained condition. All identical specimens were prepared to compact with same initial water content for five layers and saturated using control panel and then sheared under initial effective confining pressure, 100 to 400kPa. All specimens exhibited a strain softening tendency after failure in stress-strain curves and deviator stresses of specimens with 10% silt content were greater than those of specimens with 30% silt content. Pore water pressures of specimens with 10% silt content were observed negative(i.e. swelling) due to increasing void ratio after failure but those of specimens with 30% silt content were shown only positive. The behavior of compacted cylindrical specimens with low silt content was more dilative than that of high silt content. Peak deviator stresses decreased as increasing silt content and peak pore water pressures increased as increasing silt content.

Determination of Suitable Antecedent Rainfall Days for Curve Number Estimation (CN값 산정을 위한 적정 선행강우일수의 결정)

  • Lee Myoung Woo;Choi Seoung An;Kim Hung Soo;Shim Myung Pil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.553-557
    • /
    • 2005
  • 유역의 강우-유출 분석에서 유효우량의 산정은 매우 중요하다고 할 수 있다. 이러한 유효우량의 산정에서 대상호우에 대한 유출량 자료가 있는 경우는 침투지수법(infiltration index method)중 하나인 $\Phi$-지표법이나 W-지표법을 사용하여 그 양을 산정할 수 있다. 그러나 대상호우에 대한 유출량 자료가 없는 경우는 침투지수법을 이용하여 유효우량을 산정 할 수 없으며, 이러한 경우 유역의 토양 특성과 식생피복 상태에 대한 자료만으로 총우량으로부터 유효우량을 산정할 수 있는 NRCS(Natural Resources Conservation Service)의 유효우량 산정방법이 널리 사용되고 있다. NRCS유효우량 산정 방법은 선행토양함수조건(antecedent moisture condition, AMC)을 이 용하여 유출곡선지수(runoff curve number, CN)를 결정하는데, 이때 AMC의 산정을 위해 선행5일강우량(total 5-day antecedent rainfall)을 그 기준으로 하고 있으나, 이는 미국의 유역을 대상으로 하여 얻어진 결과이므로 이를 국내 유역에 검증 없이 적용하는 데에는 문제가 있을 것으로 예상되었다. 따라서 본 연구에서는 HEC-HMS모형을 이용하여 선행강우일수을 변화시켜 가면서 실제 유역의 강우-유출에 적용하여 본 뒤 강우-유출을 가장 잘 모의하는 선행강우일수을 결정하였다. 이를 위해, IHP 대상유역인 보청천의 탄부소유역에 대하여 AMC의 산정을 위한 선행강우량을 1일부터 7일까지 변화시키며 적용한 결과 탄부소유역에서는 선행2일강우량이 가장 적합한 결과를 주는 것으로 나타났다. 국내 유역에서 NRCS유효유량 산정방법을 통한 강우-유출모의시 보다 정확한 값을 산정하기 위해서는 대상유역에 적합한 선행 강우일수의 결정이 중요하리라 판단된다.인 분석을 수행하고, 배수갑문 개방에 의한 수질개선효과를 최대화하기 위한 환경관리 방안 제시에 중점을 두어 수행하였다.ncy), 환경성(environmental feasibility) 등을 정성적으로(qualitatively) 파악하여 실현가능한 대안을 선정하였다. 이렇게 선정된 대안들은 중유역별로 검토하여 효과가 있을 것으로 판단되는 대안들을 제시하는 예비타당성(Prefeasibility) 계획을 수립하였다. 이렇게 제시된 계획은 향후 과학적인 분석(세부평가방법)을 통해 대안을 평가하고 구체적인 타당성(feasibility) 계획을 수립하는데 토대가 될 것이다.{0.11R(mm)}(r^2=0.69)$로 나타났다. 이는 토양의 투수특성에 따라 강우량 증가에 비례하여 점증하는 침투수와 구분되는 현상이었다. 경사와 토양이 같은 조건에서 나지의 경우 역시 $Ro_{B10}(mm)=20.3e^{0.08R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고

  • PDF

An Experimental Study of the King Sejong Station and Siberian Frozen Soils (세종기지 및 시베리아 흙의 동결특성 시험)

  • Kim, Youngchin;Shin, Jaewon;Son, Seungmo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.2
    • /
    • pp.5-12
    • /
    • 2009
  • Soil samples from the King Sejong Station in Antarctic and Vladivostok were tested in the laboratory and specific gravity, compaction curve, grain size distribution were determined. The effect of temperature change on the thermal conductivity, unfrozen water content, compressive strength were investigated. In addition, the change of tensile strength with temperature of the soil from Vladivostok was measured. Samples for the compressive strength test and tensional strength test were prepared in a mould with a fixed volume to prevent swelling. Also the effects of temperature and water content change on those strength were compared. Results from the thermal conductivity test showed that thermal conductivity values for both soils was larger at temperatures below freezing than those above freezing. The unfrozen water content dropped rapidly within a temperature range of $0{\sim}-5^{\circ}C$ and then gradually decreased further $-20^{\circ}C$. Compressive strength test results showed various stress/deformation curves with a change in water content. Sandy soil of the King Sejong Station had a much larger strength than ice at an identical temperature, while clayey soil of Vladivostok had a smaller strength than ice in the initial stage, but showed a larger strength at temperatures belows $-15^{\circ}C$. Tensile strength tests revealed an increase in the strength with a decreasing temperature.

  • PDF

Shear Load Transfer Characteristics of Friction Piles in Deep Soft Clay (대심도 연약지반상 마찰말뚝의 주면하중전이 거동 분석)

  • Moon, Joon-Shik;Paek, Jin-Yeol;Jeong, Sang-Seom;Ko, Jun-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.10
    • /
    • pp.55-67
    • /
    • 2011
  • The shear load distribution and deformation of offshore friction piles are investigated using experimental tests and a numerical analysis. Special attention is given to the soil-pile interaction of axially loaded pile. A framework for determining the f-w curve is proposed based on both theoretical analysis and experimental load test data base. A numerical analysis that takes into account the proposed f-w curves was performed for major parameters on pile-soil interaction such as the pile diameter, the pile length, and the soil condition. Based on the analysis, it is shown that the proposed f-w method is capable of predicting the behavior of a friction pile in deep soft clay. Through comparisons with case histories and finite element results, it is found that the proposed f-w curves are more appropriate and realistic m representing the pile-soil interaction of axially loaded piles in deep soft clay than that of existing f-w method.

The Effect of Cement Milk Grouting on the Deformation Behavior of Jointed Rock Mass (시멘트현탁액 주입에 의한 절리암반의 역학적 특성 변화)

  • 김태혁;이정인
    • Tunnel and Underground Space
    • /
    • v.13 no.5
    • /
    • pp.331-343
    • /
    • 2003
  • Though the Grouting has been in use for a long time, it is still regarded as an technique rather than engineering. The study of ground improvement by grouting is rare especially in jointed rock mass. In this study, biaxial compression tests were performed in the jointed rock mass models with .ough surfBce joints assembled with blocks before and after grouting. The load-deformation curves of the jointed rock masses showed a non-linear relationship before grouting but showed a relatively linear deformaion behavior after grouting. Improvement ratio (deformation modulus after grouting/deformation modulus before grouting) decreased with increasing joint spacing and lateral stress. Improvement ratio decreased exponentially with increasing deformation modulus of the rock mass model before grouting. Three-dimensional FDM analysis was performed to a highway tunnel case using experimental data of grouted rock. The convergence of the tunnel predicted after grouting by the numerical modelling coincided with those attained from the field measurement.