• Title/Summary/Keyword: 할출

Search Result 4, Processing Time 0.019 seconds

A Study on the Indexing Table by the Penumatic Poeration (공기압 구동 원주 할출 기구의 개발에 관한 연구)

  • 오진안;강인각;한창수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.734-738
    • /
    • 1997
  • In this study, we developed the indexing table opering by pneumatic actuation. We doubled the torque of index table by using specialy desingned air pipe and two pistons. And by locating two pistons We perform several tests and this results is written below.

  • PDF

Extraction of the control data for the shoe laster by using tension spline method and verification of the geometric grading system (Tension spline 방법을 이용한 제화용 라스팅기의 제어데이터 추출 및 기하할출제도의 검증)

  • Jang, Kwang-Keol;Kim, Seung-Ho;Huh, Hoon
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.140-145
    • /
    • 2001
  • Lasting machines for shoe manufacturing are continuously developed with the aid of automation and Computer Aided Manufacturing (CAM). Adaptive lasting machine and CAD data of a shoe last are inevitably introduced for the labor-free manufacturing process. Recently, method for the CAD datarization of a shoe last is suggested using finite element mesh system. Initial set up data and control data of machine parts are required for the adaptive lasting machine. For the efficient process, grading of those data is essential to minimize data storage and production costs. In this paper, bonding lines are extracted from the CAD data of a shoe last and graded by the geometric grading system. Tension spline method is adopted for the interpolation of last CAD data. The results are compared with the results from the arithmetic grading system that is widely adopted in the shoemaking companies.

  • PDF

Design of Platform Independent 3D Shoe CAD System (플랫폼에 독립적인 3D 신발 캐드 시스템의 설계)

  • Lee, Yun-Jung;Lee, Young-Sook;Kim, Young-Bong
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.8
    • /
    • pp.1010-1019
    • /
    • 2006
  • CAD system is a very important technology in designing the products which we are using today. This CAD technology has been enlarging its area into 3D CAD systems with the development of computer graphics technologies. In particular, such advances have been realized in special area such as the CAD system for designing shoes. However, because it is difficult to design a 3D CAD system, most CAD developments except for major CAD software companies usually have employed the AutoCAD which realizes 3D concepts. Also, many shoes' designers have been skilled with 2D shoe CAD systems and then they can make high achievements. Therefore, we design a new shoe CAD system with advantages of 2D CAD system and 3D CAD system. We also implement the scheme to transfer the data between 2D CAD system and 3D CAD system and also grading technologies to get patterns of various shoes size from a basic shoe's design.

  • PDF

A Study on Verification of Shoe Last Grading System Based on Foot Measuring Data (발계측 자료에 기초한 신골 할출 시스템의 검증에 관한 연구)

  • Park, Hae-Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.71-77
    • /
    • 2007
  • Shoe's size and shape are determined by the last that takes shape of foot because last is the mold of shoe in development and manufacturing process. Then adaptation between foot and shoe is dependent on the last. In mass shoe production, model size is developed in the first place, other sized lasts are made through the grading process based on model size. The most important factor in grading system is grading deviation that must be same amount induced from foot measuring database. At present, most of the last manufacturing companies in korea using 260mm as a standard foot model size. When length grading deviation is 5mm, the ball girth grading deviation is 3.7mm and the ball width grading deviation is 1.2mm. I verified existing grading system by comparing grading results with foot measuring data. Also, I proposed reasonable grading deviation and application method of grading system. From the analysis of foot measuring database, reasonable grading deviations are 1.22mm in ball width and 0.84mm in ankle height in case of length grading deviation is 5mm. I confirmed that the current grading system is very accurate. When we grade last from 230mm to 290mm by current grading system based on model size 260mm, there is grading error over 1mm in the front outside area of foot. This error level of 1mm is no problem in normal walking shoe's last, but it induces adaptation problems in sports and special purposed shoe's last. Therefore using of three standard model size is recommended in grading men's last for reducing grading deviation error under the level of 1mm. It is specifically described as 235mm in 225-245mm, 260mm in 250-270mm, 285mm in 275-295mm. According to the above recommended grading system, it is enough to measure only three foot sizes in case of foot measuring project for men's last development.