• Title/Summary/Keyword: 할로겐

Search Result 440, Processing Time 0.027 seconds

Radio Thin Layer Chromatography of Organic Halogen Compounds (有機할로겐化合物의 放射化 Thin Layer Chromatography)

  • YOU SUN KIM;SOON KO KIM;KI SOO KIM
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.2
    • /
    • pp.45-50
    • /
    • 1967
  • Radio thin layer chromatography of organic halogen compounds by neutron irradiation technique was investigated for the purpose of identifying and separating the mixture of halogen compounds. It was found that various halides, organic acids, and aldehyde gave a distinct developing peak both in cases of individual compound and a mixture of two or three components when the samples were developed by solvent methanol. But poly chlorinated compounds and aromatic or alicyclic chlorides gave more than one component peak when the sample was developed after neutron irradiation. Rf value of each compound was distinct and reproducible. The procedures were described and validity of the present method is discussed.

  • PDF

Early Detection of Clear Egg in Incubation Using VIS/NIR Spectroscopy (VIS/NIR 분광분석법을 이용한 미부화란의 조기 검출)

  • Kim, Hak Sung;Kim, Ghi Seok;Kim, Yong Ro;Kang, Seok Won;Noh, Sang Ha
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.104-104
    • /
    • 2017
  • 정상적인 부화 여부를 판별하기 위한 1차 검란은 일반적으로 5일~7일 이후에 시행된다. 미부화란을 이보다 더 빠른 시간 안에 검출할 경우 부화에 소요되는 에너지의 감소 효과 및 미부화란을 다른 용도로 활용하는 것을 기대할 수 있다. 시중에서 쉽게 구입할 수 있는 산란계인 하이라인 브라운 품종의 유정란 29개와 인위적인 미부화란을 만들기 위한 동일 품종의 무정란 11개를 사용하였으며 $38^{\circ}C$, 70% 조건의 항온항습기에서 96시간 동안 부화하였다. 스펙트럼 획득 장치의 광원은 녹색영역을 발광하는 LED램프와 일반 할로겐 광원을 별도로 사용하였으며 스펙트로미터는 VIS/NIR 영역인 520~1,180nm영역과 NIR영역인 900~1,700nm영역의 것을 사용하였다. 부화 시작 전과 부화 시작 후 1일 간격으로 각각 1개의 샘플에 대한 1개의 스펙트럼을 측정하였다. 측정 영역은 LED광원을 이용한 경우는 520~1,1800nm, 할로겐광원을 이용한 경우에는 520~1,180nm와 900~1,700nm이었다. 정상 부화여부는 4일차에서 할란하여 확인하였고, 측정 일자별로 PLS-DA분석법을 이용한 판별 모델을 개발하였다. 4일차에서 유정란 29개 중 11개가 정상 부화하였고, 18개는 미부화하였다. 3일차에서 판별 모델의 정확도는 LED광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 100%, 할로겐 광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 70%, 할로겐 광원의 NIR영역 스펙트럼을 이용한 경우는 70%였다. 4일차에서 판별 모델의 정확도는 LED광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 100%, 할로겐 광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 90%, 할로겐 광원의 NIR영역 스펙트럼을 이용한 경우는 100%였다. 부화 3일차는 정상 부화할 경우 피가 생성되는 시기이다. 피가 형성된 이후의 부화 여부를 판단하는 광원으로는 할로겐램프보다 LED램프를 사용하는 것이 더 적합한 것으로 나타났다.

  • PDF

Halogen Exchange Reactions of Benzyl Halides Part Ⅲ-Kinetics of Reactions of Bromide and Iodide Ions with Benzyl Chloride and Bromide in Absolute Acetone (벤질 할라이드의 할로겐 교환반응 (제Ⅲ보) 아세톤 중에서의 염화 및 브롬화 벤질과 브롬화 및 요오드화 이온간의 교환반응)

  • Hangbo Myung-Hwan;Lee Bon-su;Lee Ik Choon
    • Journal of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.109-114
    • /
    • 1969
  • Halogen exchange reactions of benzyl halides have been studied in absolute acetone. Rate constants were calculated using an integrated rate expression derived for the reaction involving ion-pair association. The order of nucleophilicity of halide ions in acetone was found to be a reverse of the order in 90% aqueous enthanol solvent. This was interpreted by means of HSAB principle and solvation of halide ions. Net increase in rate of reaction in acetone compared with the rate in protic solvent resulted from large increase in ${\Delta}S^\neq$ rather than decrease in ${\Delta}H^\neq$. The solvation of the transition state also contribute to the net increase in rate.

  • PDF

Transmitting Ability of Halogen Light in Different Composite Resin Colors (복합레진 색상에 따른 Halogen light의 투과도)

  • Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.447-453
    • /
    • 2010
  • The purpose of this study was to compare the light transmitting ability of halogen light in different colors and thicknesses. A1, A2, A3 colors of Z-250 composite resin(3M ESPE, St. Paul, U.S.A.) were used. Degree of conversion of separated resin specimens under the 2, 3, 4mm thickness resin were measured by FTIR spectroscopy. The result shows that decrease of degree of conversion by increase of resin thickness and decrease of degree of conversion by decrease of lightness of color. Within the limitation of results, it is recommended to use more light color of composite resin in small thickness to improve degree of conversion when use halogen light.

Halogenation of Cannabinoids (Cannabinoid의 할로겐화)

  • Baek Seung-Hwa;Park No-Yeun
    • Journal of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.59-63
    • /
    • 1991
  • Several types of cannabinoids have been halogenated in the aromatic ring in good yields with metal halide in the presence of 18-crown-6 on oxidation with m-chloroperbenzoic acid. This reagent system effects the regiospecific halogenation of activated aromatic ring over olefinic double bond.

  • PDF

A Study on the Risk of Halogen Lamp for Pigsty Heating and Fire Prevention (축사 난방용 할로겐램프의 위험성 및 화재 예방에 관한 연구)

  • Lee, Jae kyung;Seo, Seong Hyeon;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.553-564
    • /
    • 2021
  • This study analyzed the the risk of halogen lamp for pigsty heating and its fire prevention. Halogen lamps are used for keeping warm in pen because of their excellent economy and convenience. However, there is a high risk of fire due to poor safety management and exposure to animal movements. In fact, after exploring old pigsty and cattle shed, it was easy to confirm that they were exposed to fire risks. We noted this point and studied the possibility of fire by experiment due to combustible contact with halogen lamp and carelessness in use. The experiment was conducted under conditions similar to the actual use environment. After installing halogen lamps to the height used in actual pen, the temperature change was observed with infrared camera with straw, sawdust and rice husks on the floor. And assuming abnormal conditions, the experiment was also conducted under conditions the lamp dropped on the floor or combustible material came into contact with the glass tube inside the lamp. If halogen lamps were used in normal condition, there was no risk of fire. However, in abnormal use environments, smoke comes out or even ignited. Even if it is convenient for use or highly utilized, high risk of fire will require setting up fire prevention measures or regulation of use. Through in-depth fire investigation and research, we should promote the risk of fire and make efforts to prevent fire to minimize human life and property damage.

A Study on the Silver Iodide Membrane Electrode (AgI / PVC${\cdot}$THF) (Ⅱ). Potentiometric Titration Error of Halide Mixture (요오드화은막전극 (AgI / PVC${\cdot}$THF) 에 관한 연구 (제2보). 할로겐화 이온혼합물의 전위차법 적정오차에 관한 연구)

  • Kee Chae Park;Young Soon Kwon
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.253-262
    • /
    • 1981
  • The AgI/ PV${\cdot}$THF membrane electrode could be used as an indicator electrode in the potentiometric titration of single halide and mixture halide solutions with the standard solution of silver nitrate. The errors in the stepwise titrations of mixture halide solutions were considerably large, but by addition of flocculating agent, such as $NaNO_3$ or $Ba(NO_3)_2$, in the sample solution, the errors were greatly reduced. Also, the effects of gelatin, filter paper and temperature on the titration errors were examined.

  • PDF

A Study on Corrosion of the HFC-125 fire extinguishing agent for Metal and Non-Ferrous Metal (HFC-125 소화약제의 금속 및 비철금속 부식성 평가에 관한 연구)

  • Lee, Chang-Woo;Ham, Eun-Gu;Yoo, Ju-Yeol;Seo, Sang-Hun;Kim, Gin-Sung;Cho, Yong-Sun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2016.11a
    • /
    • pp.271-274
    • /
    • 2016
  • 본 논문에서는 오존층 파괴 및 지구 온난화에 악영향을 미치는 할로겐화합물 소화약제를 대체하여 개발된 청정소화약제인 할로겐화합물 청정소화약제(Halocarbon clean agent)의 열분해 생성물(thermal decomposition products)의 영향에 평가하고자 한다. 이를 위해 할로겐화합물 청정소화약제인 HFC-125가 화원 크기의 변화에 따른 열분해 생성물의 미치는 영향을 측정하기 위해 소화시험을 실시하였고 금속(철), 비철금속(구리), 유리 시편의 부식성과 전자부품(SD-Card) 작동여부를 평가 하였다. 금속 및 비철금속 시편의 부식성을 측정하기 위해 디지털 카메라를 통해 이미지를 촬영하고 그래픽 편집 소프트웨어를 이용하여 채도(saturation)를 측정하여 부식성의 정도를 분석하였다. 금속, 비철금소, 유리 시편의 부식성 분석 결과, 화원의 크기가 증가할수록 금속 및 비철금속의 부식성이 증가하였다. 즉, 화원의 크기(fire size)에 따라 열분해 생성물질도 증가하여 금속 및 비철금속의 부식을 증가시키는 것으로 사료된다.

  • PDF