• Title/Summary/Keyword: 한류기

Search Result 379, Processing Time 0.026 seconds

EMTDC simulation for current limiting characteristics of the resistive and inductive SFCL (저항형과 유도형 한류기의 전류제한특성에 대한 EMTDC 해석)

  • 최효상;황시돌;현옥배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.255-258
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with 100 $\Omega$ of quench impedance for a single line-to-ground fault. which accounts for about 70% of the total power line faults, in the 154 kV transmission system. The fault simulation at the phase angles 0$^{\circ}$, 45$^{\circ}$, and 90$^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 12 KA, but with 3 kA of DC component which decreased to zero in 5 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

The conceptual design and analysts of three phase superconducting fault current limiter (일체형 삼상 고온 초전도 한류기의 단락 특성 해석)

  • Lee, Sueng-Je;Lee, Chan-Joo;Lee, Chang-Yul;Jang, My-Hye;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.94-97
    • /
    • 1998
  • The conceptual design of integrated three phase superconducting fault current limiter (SFCL) is presented. And through simulation of power system where this SFCL is installed, the characteristics of this SFCL is analyzed. It is like three-phase transformer. So it has the same characteristics with inductive single phase SFCL. But it has more merits than single phase SFCL. Differently to single phase SFCL, integrated three phase SFCL induces impedance at all phase by any single phase fault to protect the power system more safely.

  • PDF

Generated heat decrease of resistive superconducting fault current limiter using diodes (Diode를 이용한 저항형 초전도 한류기의 열발생 저감방안)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.925-927
    • /
    • 2000
  • We fabricated a resistive superconducting fault current limiter of meander type based on a YBCO film. In order to disperse the heat generated at hot spots in the YBCO film the film was coated with a gold shunt layer. When diodes were inserted in the parallel circuit to restrict the temperature increase in the SFCL element by reducing power supply cycles, the voltage could be increased to $\sqrt{2}$ times with the same quench resistance at a half and full cycles.

  • PDF

Stability Analysis of Power System Instal1ed Superconducting Fault Currnt Limiter (고온 초전도 한류기가 설치된 전력 시스템의 안정도 해석)

  • Lee, Sueng-Je;Lee, Chan-Joo;Lee, Chang-Youl;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.346-348
    • /
    • 1998
  • The stability of Power system installed Hi-Tc Superconducting Fault Current Limiter(SFCL) is analyzed as a process of developing SFCL. In interpretation, simple mimic system(only one motor) is assumed and then the circuit with SFCL in system is solved. In case the SFCL is installed in Power system, it protected synchronization more effectively both in symmetrical 3-phase fault and single phase line to ground fault.

  • PDF

Novel Design and Operational Characteristics of Inductive High-Tc Superconducting Fault Current Limiter to Protection the Power System (전력시스템 보호를 위한 공극을 이용한 유도형 고온초전도체 한류기의 디자인과 동작특성)

  • Jang, Mi-Hye;Lee, Chan-Joo;Joo, Min-Seok;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.281-283
    • /
    • 1999
  • A novel prototype of an inductive superconducting fault current limiter with an iron core and an air sap was fabricated and tested. If its impedance is not high enough to limit the fault current, then destructive damage occurs in the power system. We attained a magnetic saturation under the higher current by introducing an air gap in the three-legged magnetic core. The fault current was successfully limited to two times as much as the nominal current without high fault current within 1/4 cycles at a 60 Hz source having an effective voltage of 70V.

  • PDF

Equal Current Distribution in Parallel Resistive SFCL Using SIPT (SIPT를 이용한 병렬 저항형 한류기의 평형전류분배)

  • 심정욱;최용선;김혜림;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.109-112
    • /
    • 2003
  • Small impedances in the superconducting parallel circuits cause unequal distribution of the currents in the circuits. This results in quenches or losses in some superconducting parts and decrease of total transport current. This paper presents the fabrication and test results of a superconducting multi- interphase transformers (SIPT) for equal current distribution in superconducting parallel circuits. The secondary loop configuration with air core SIPT seems to be the most efficient one for the SFCL. Test results show that the SIPT can effectively make the current distribution uniform in Parallel circuits that have unequal resistances.

  • PDF

The Study on Insulation Coordination on 22.9kV SFCL for Applying to Real Grid (22.9kV 초전도 한류기 실계통 적용을 위한 절연협조 검토)

  • Kim, T.H.;Kang, J.W.;Kang, Y.W.;Park, J.W.;Lee, H.S;Yang, B.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.1
    • /
    • pp.20-24
    • /
    • 2012
  • This paper proposes an insulation coordination and surge arrester design for superconducting power system with SFCL(Superconducting Fault Current Limiter) in Icheon substation. In the aspect of the economic analysis, since the superconducting devices are very expensive, the insulation coordination to prevent the dielectric breakdown caused by the lightning surge should be considered carefully. In this paper, the insulation coordination for real grid including SFCL and the design of the protection devices against lightning surge is verified using PSCAD/EM TDC.

Investigation of the Feasibility of a Bus-bar coupled SFCL in the 154 kV KEPCO Grid (154 kV 초전도 한류기 모선연계 적용 연구)

  • 윤용범;현옥배;황시돌;김혜림
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.291-293
    • /
    • 2003
  • Applicability and economical feasibility of a Superconducting Fault Current Limiter (SFCL) have been investigated using the PSS/E simulation for a bus bar coupling at the real 154 ㎸ KEPCO power grid near Seoul. For the investigated substation, the maximum fault current exceeds the interruption rating of 4 circuit breakers (CB) out of 9 installed in the substation. The simulation showed that a SFCL installed in the bus tie position effectively limits the fault currents to save 4 CBs, which are to be replaced by ones of gloater interruption rating, otherwise. We suggest that the optimum resistance of the SFCL be 10 Ohm for the given grid.

  • PDF

Experimental Investigation of the Subcooled Liquid Nitrogen for Resistive Superconducting Fault Current Limiter (저항형 한류기 운전조건에서의 과냉각 액체질소 특성 실험)

  • 조승연;김동락;양형석;정원묵;김도형;김혜림;현옥배
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.332-334
    • /
    • 2003
  • A subcooled liquid nitrogen cryostat is required for the cooling of a 6.6 ㎸, 200 A resistive type superconductive fault current limiter (SFCL). To help understand and design an appropriate cryostat for SFCL a prototype cryostat was fabricated and tested. Several states of subcooled liquid nitrogen were obtained by using cryocooler and helium gas. The temperature was uniformly distributed inside the liquid nitrogen vessel within the range of 0.4 K proving the effectiveness of the conduction cylinder.

  • PDF

Development of cooling system with sub-cooled nitrogen for DC Reactor of 6.6 ㎸-200A class HTS fault current limiter (6.6 ㎸-200A급 HTS 한류기 DC Reactor용 과냉질소 냉각시스템의 개발)

  • 김형진;권기범;강형구;배덕권;안민철;정은수;장호명;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.171-175
    • /
    • 2003
  • The sub-cooled nitrogen cooling system at 65 K with GM cryo-cooler is developed for cooling down the DC reactor of 6.6 ㎸-200 A class HTS Fault Current Limiter(SFCL). The sub-cooled nitrogen cooling is more economic than saturated nitrogen cooling, because the length of HTS wire is reduced in the same capacity, as well as, more stable. The cooling system with the GM cryo-cooler installed on the cryostat is not only compact but also efficient for energy saving. In the nitrogen vessel, after evacuating with vacuum pump to saturated nitrogen at 65 K, sub-cooled nitrogen at 65 K is made by putting in gas helium to 1 atm. During the short circuit test occurring the fault current of 1000 A, the sub-cooled nitrogen cooled DC reactor for SFCL is kept the state of sub-cooled nitrogen at 65 K.

  • PDF