• Title/Summary/Keyword: 한류기

Search Result 379, Processing Time 0.042 seconds

Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements. (초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석)

  • Oh, Kum-Gom;Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

A Study on the Recovery of HTS Coated Conductors Due to Different Stabilizers by the Electrical Method (전기적 측정 방법을 통한 고온 초전도 Coated Conductor의 안정화재 차이에 따른 회복시간에 대한 연구)

  • Kim, Won-Cheol;Kim, Young-Jae;Na, Jin-Bae;Jang, Jae-Young;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.834_835
    • /
    • 2009
  • 현재 전력 계통에서 발생하는 고장 전류에 대한 해결책으로 초전도전력기기인 고온초전도 한류기가 실용화를 눈앞에 두고 있다. 그러나, 실제 계통에 적용하기에는 몇 가지의 과제들이 아직 남아있다. 그 중에서도 한류소자의 회복속도는 고장전류 발생 후 계통의 재폐로와 연계되기 위한 중요한 성능 요소라고 할 수 있다. 본 논문에서는 초전도 한류 소자로 쓰일 수 있는 다양한 YBCO CC(Coated Conductor)들의 회복 시간에 대하여 실험을 통하여 연구하였다. 10 mA의 전류를 초전도선재에 지속적으로 인가하여, 고장전류 인가 후 발생하는 저항에 의한 전압의 추이를 관찰하여 회복 시간을 예측하였다. 그 후, 예측된 회복 시간 후 전류를 재투입하여 선재의 회복을 확인하였고, 실제 회복 시간과 비교하고 분석하였다

  • PDF

Domestic Efforts for SFCL Application and Hybrid SFCL (국내 초전도 한류기 요구와 하이브리드 초전도 한류기)

  • Hyun, O.B.;Kim, H.R.;Yim, Y.S.;Sim, J.;Park, K.B.;Oh, I.S.
    • Progress in Superconductivity
    • /
    • v.10 no.1
    • /
    • pp.60-67
    • /
    • 2008
  • We present domestic efforts for superconducting fault current limiter (SFCL) application in the Korea Electric Power Corporation (KEPCO) grid and pending points at issue. KEPCO's decision to upgrade the 154 kV/22.9 kV main transformer from 60 MVA to 100 MVA cast a problem of high fault current in the 22.9 kV distribution lines. The grid planners supported adopting an SFCL to control the fault current. This environment friendly to SFCL application must be highly dependent upon the successful development of SFCL having specifications that domestic utility required. The required conditions are (1) small size of not greater than twice of 22.9 kV gas insulated switch-gear (GIS), (2) sustainability of current limitation without the line breaking by circuit breakers (CB) for maximum 1.5 seconds. Also, optionally, recommended is (3) the reclosing capability. Conventional resistive SFCLs do not meet (1) $\sim$ (3) all together. A hybrid SFCL is an excellent solution to meet the conditions. The hybrid SFCL consists of HTS SFCL components for fault detection and line commutation, a fast switch (FS) to break the primary path, and a limiter. This characteristic structure not only enables excellent current limiting performances and the reclosing capability, but also allows drastic reduction of HTS volume and small size of the cryostat, resulting in economic feasibility and compactness of the equipment. External current limiter also enables long term limitation since it is far less sensitive to heat generation than HTS. Semi-active operation is another advantage of the hybrid structure. We will discuss more pending points at issues such as maintenance-free long term operation, small size to accommodate the in-house substation, passive and active control, back-up plans, diagnosis, and so on.

  • PDF

A Study on the Reliability Model of Superconducting Fault Current Limiter (초전도한류기의 신뢰도 모델에 관한 연구)

  • Bae, In-Su;Kim, Hyoung-Ju;Lee, Sang-Kyo;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.393_394
    • /
    • 2009
  • 초전도한류기(SFCL)는 고장전류에 대한 초고속 감지, 고장전류 제한이 가능하고, 정상계통에서는 무손실 운영이 가능한 신개념의 기기이다. 공급신뢰도 측면에서 SFCL은, 고장전류 저감으로 송전을 지속할 수 있는 장점이 있는 반면, 기존 계통에 직렬연결되므로 자체 고장으로 인해 공급신뢰도를 악화시킬 수도 있다. 특히, 고속스위치를 필요로 하는 하이브리드형 SFCL의 경우 계통연계 이전에 SFCL 자체의 신뢰성이나 주위 계통에 미치는 영향을 미리 검토해야 한다. 본 논문에서는 SFCL의 신뢰도 데이터를 계산하는 기법과 SFCL 인근 설비의 신뢰도 데이터를 갱신하는 방법에 대해 제시하였으며, 이는 SFCL가 연계된 배전계통의 수용가 공급신뢰도를 산출하기 위해 필요한 사전단계에 해당한다.

  • PDF

Research and development of superconductor in the energy application area (에너지 응용분야에서의 초전도체 연구동향)

  • 장건익;유재근;이호진;홍계원
    • Electrical & Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.310-319
    • /
    • 1996
  • 본 연구에서는 초전도의 전반적인 시장규모, 에너지 분야에서의 고온 초전도 연구 진척 내용, 마지막으로 저온 초전도체의 기술현황을 토대로 저온을 고온 초전도체로 대체 시 이에 따른 대체 효과를 비교 분석하고자 하였다. 하지만 고온 초전도체에 관한 기술적 문제가 아직 많은 문제로 제기되고 있어 정확한 기술적 판단에는 아직 상당히 미흡하다고 여겨진다. 또한 초전도를 이용한 에너지 응용범위가 너무 광범위하여 본고에서는 대표적 응용분야 몇 가지만 소개하고자 한다. 참고로 4K와 77K의 차이점을 평가할 때의 기준은 자기장과는 무관하게 임계전류밀도를 77K에서 $10-^5$$cm^2$으로 가정 실시한 것이다.

  • PDF

Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current (전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구)

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

Feasibility Study on the Application of 154kV HTS-FCL in Korean Power System (국내 실계통에서의 154kV 초전도한류기 계통적용 가능성 검토)

  • Lee Seung Ryul;Kim Jong-Yul;Choi Heung-Kwan;Yoon Jae Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.12
    • /
    • pp.661-669
    • /
    • 2004
  • As the load density of KEPCO system is higher, the fault current can be much higher than SCC(Short Circuit Capacity) of circuit breaker. Fault current exceeding the rating of circuit breaker is a very serious problem in high density load area, which can threaten the stability of whole power system. Even though there are several alternatives to reduce fault current, as the superconductivity technology has been developed, the HTS-FCL (High Temperature Superconductivity Fault Current Limiter) can be one of the attractive alternatives to solve the fault current problem. This study presents the application plication of 154kV HTS-FCL in Korean power system.

One Chip design of Electric Power Conversion Controller that use FPGA for SFCL(Superconducting Fault Current Limiter) (유도형 한류기를 위한 FPGA를 이용한 전력변환 제어기의 One Chip 설계)

  • 박근태;이양주;이창열;김동준
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.189-192
    • /
    • 2003
  • Inductivity Superconducting Fault Current Limiter is the Magnet that uses high temperature Superconductivity Coil. It is an important work that it controls Electric Power Converter of Inductivity SFCL. So, we wish to design the point part FPGA by One-Chip. Design of that can divide as following. One part that generate clock that offer to thyristor. One part that set 60Hz voltage to input Clock and do count. One part that change the value that require in CPU to the integer. And finally. there is part that send output (the fixed Clock) to the thyristor.

  • PDF

Analysis on Voltage Sag in Power Distribution System according to SFCL's Impedance for Protective Coordination with Large Transformer (배전계통에 대용량변압기 교체 적용시 초전도 한류기의 임피던스에 따른 순간전압 분석)

  • Kim, Jin-Seok;Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.312-316
    • /
    • 2014
  • In this paper, a voltage sag is analyzed in case of superconducting fault current limiter (SFCL) installed in power distribution system where replaces the main power transformer to large one to meet the power demand. First, the power system is configurated to analyze the operation characteristics of the protective relay with replacement of the main transformer and application of the SFCL. Next, the method to meet the protection coordination is analyzed with large transformer using PSCAD/EMTDC. Finally, the bus voltage is investigated according to the impedance of both main transformer and SFCL in case that the SFCL is applied into feeder.

Characteristics of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry using 2-D FEM (수치해석을 이용한 적층 배열에 따른 BSCCO 적층선재의 자화손실 특성)

  • Park, Myung-Jin;Lee, Kwang-Youn;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.945-947
    • /
    • 2005
  • 변압기, 케이블, 한류기와 같은 고온초전도 선재의 전력기기의 개발과 응용에 있어서 교류손실은 기기의 운용과 효율에 밀접한 관계가 있기 때문에 중요한 연구 분야가 되고 있다. 또한 현재 전력기기에 응용 하고 있는 고온초전도 선재는 전력기기에 필요한 통전용량을 수용 할 수 없기 때문에 이를 해결하기 위한 방법으로 선재를 적층하여 통전용량을 증대시키는 다양한 방법이 연구되고 있다. 본 논문에서는 고온초전도 선재의 적층배열을 달리 하였을 때, 외부자계에 의한 고온초전도 선재의 자화손실 특성에 대해서 연구하였다. 선재의 적층 배열의 형상은 Edge-to-Edge, Face-to-Face형과 Matrix형이며, 적층배열에 사용한 선재의 개수는 2, 4, 8개이다. 연구결과, 동일한 적층 수의 조건하에서 Face-to-Face형의 적층배열이 다른 종류의 배열보다 자화손실이 낮음을 확인하였고, 이는 Face-to-Face 형태로 적층 될 때 인접선재로 인한 자기차폐효과가 다른 배열의 경우보다 우수하기 때문으로 보인다.

  • PDF