• Title/Summary/Keyword: 한국의 방사선치료

Search Result 1,039, Processing Time 0.03 seconds

Fractionated Stereotactic Radiotherapy (FSRT) Using Gold Markers : A Comparison of the Isocenter between Multiple Arcs and Static Conformal Beams (금속표지자를 이용한 다중호형 정위방사선치료와 입체조형 정위방사선치료의 회전중심점 비교)

  • 장지영;김기환;김재성;김준상;송창준;김선환;조문준
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • The aim of the study was to assess the isocenter deviation between multiple arcs and conformal beams in frameless FSRT. Forty seven patients received single isocenter radiosurgery or therapy (SRS/T) using available framelss FSRT system from Aug. 1997 to Dec. 2m. In choosing multiple arc FSRT or conformal FSRT, we had considered one of two techniques with respect to tumor size and tumor shape. In multiple arc FSRT, the average and standard deviation (SD) of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.2 mm (SD 0.2) and 0.3 mm (SD 0.2 mm)in the lateral (x), anterior-posterior (y) and cranio-caudal directions (z). In conformal FSRT, the average deviation and SD of the isocenter deviation was 0.2 mm (SD 0.2 mm), 0.3 mm(0.2 mm) and 0.4 mm (SD 0.2 mm) in the x, y and z directions. The average spacial deviation ($\Delta$r) was 0.41 mm and 0.54 mm in multiple arcs and conformal beams, respectively. The isocenter deviation using frameless FSRT system was similar value between multiple arcs and conformal beams. In practice, we believed we can select the appropriate treatment technique according to tumor shape and size.

  • PDF

감마나이프 방사선치료에서 소프트웨어와 하드웨어 시간설정차이에 의한 처방선량에 주는 영향

  • 서원섭;임영진;신동오
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.60-60
    • /
    • 2003
  • 목적 : 감마나이프 치료계획용 소프트웨어인 감마플렌에서 처방선량을 계산하는 단위와 실제 시간을 설정하는 하드웨어인 조정판의 시간설정 단위의 차이에 의한 실제 처방선량에 끼치는 영향을 계산하였다. 대상 및 방법 : 감마나이프는 주어진 4 개의 헬멧을 가지고 최소 한번 또는 최대 20 번 이상의 방사선 조합으로 한번에 많은 방사선을 목표물에 조사한다. 감마나이프 방사선 수술을 위한 치료계획용 소프트웨어인 감마플렌 5.32에서는 처방선량에 대한 치료시간을 최대 지점 또는 지정하는 지점에 규격화하여 소숫점 두 자리 즉 0.6 초까지 계산한다. 그러나 실제 치료를 위한 조정판의 시간설정은 모델 B 에서는 소숫점 한자리까지 가능하게 되어있다. 그러므로 모델 B를 사용하는 기관의 치료계획 컴퓨터인 감마플렌에서는 소숫점 한자리로 만들기 위해 반올림과 내림을 하게 되며 이것을 프린트하여 사용하게 된다. 실제 임상에서 멀티삿에 대한 반올림과 내림에 대한 효과를 선량으로 환산하여 처방선량에 끼치는 영향을 연구하였다. 치료 계획에 서 처방선량을 입력한 후 계산된 각 조사에 대한 소숫점 두자리 시간을 화면에 표시한 후 스냅tit으로 스크린 캡쳐하여 프린트하였으며, 소숫점 한자리로 된 최종 치료계획을 프린트하여 서로 비교 계산하였다. 결과 : 20 여명의 환자에 대한 치료 결과에 대한 분석은 조사의 수나 처방선량에 관계하지 않고 우연히 올림이 많으냐 내림이 많으냐에 의존하였다. 최대지점에 대하여 분석한 결과는 -0.48부터 +0.47로 -2%부터 +1.9%의 정도로 영향을 끼쳤다. 결론 : 반올림과 내림의 결과는 처방선량을 줄일 수도 있고 늘일 수도 있었다. 그러나 이 연구는 최대선량 지점에 대해 비교를 하였으나 실제로는 각 조사의 위치가 서로 다르므로 영향은 이보다 훨씬 적을 것으로 생각되어 소숫점 한자리로 치료하여도 무방할 것으로 보인다.mm, AP 방향에서는 2.1$\pm$0.82 mm이었다. 그리고 복부의 later의 방향에서는 7.0$\pm$2.1 mm, AP 방향에서는 6.5$\pm$2.2 mm 이었다. 또한 표적 위치측정을 위해서 환자의 피부에 임의의 가상표적을 부착하고 CT 촬영한 영상결과, 프레임으로 가상표 적에 대한 위치를 정확히 파악할 수 있었다. 결론 : 제작된 프레임을 적용하여 방사선투과율 측정실험, 환자 외부자세에 대한 오차 측정실험, 가상표적 위치측정 실험 등을 수행하였다. 환자 외부자세에 대한 오차 측정실험 경우, 더 많은 Volunteer를 적용하여 보다 정확한 오차 측정실험이 수행되어야 할 것이며 정확한 표적 위치 측정실험을 위해서 내부 마커를 삽입한 환자를 적용한 임상실험이 수행되어야 할 것이다. 또한 위치결정에서 획득한 좌표값의 정확성을 알아보기 위해서 팬톰을 이용한 방사선조사 실험이 추후에 실행되어져야 할 것이다. 그리고 제작된 프레임에 Rotating X선 시스템과 내부 장기의 움직임을 계량화하고 PTV에서의 최적 여유폭을 설정함으로써 정위 방사선수술 및 3 차원 업체 방사선치료에 대한 병소 위치측정과 환자의 자세에 대한 setup 오차측정 결정에 도움이 될 수 있을 것이라고 사료된다. 상대적으로 우수한 것으로 나타났으며, 혼합충전재는 암모니아의 경우 코코넛과 펄라이트의 비율이 7:3인 혼합 재료 3번과 소나무수피와 펄라이트의 비율이 7:3인 혼합 재료 6번에서 다른 혼합 재료에 비하여 우수한 것으로 나타났다. 4. 코코넛과 소나무수피의 경우 암모니아 가스에 대한 흡착 능력은 거의 비슷한 것으로 사료되며, 코코넛의 경우 전량을 수입에 의존하고 있다는 점에서 국내 조달이 용이하며, 구입 비용도 적게 소요되는 소나무수피를 사용하는 것이 경제적이라고 사료된다. 5. 마지막으로

  • PDF

Evaluation of Treatment Planning for Head Tilting in WBRT 3D-CRT by TomoDirect mode: a Phantom Study (토모다이렉트를 이용한 3차원 전뇌 방사선치료에서 두상 각도에 따른 치료계획평가: 팬톰 실험)

  • Dae-Gun, Kim;Sang-Hyun, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.857-862
    • /
    • 2022
  • The purpose of this study was to evaluate a three-dimensional conformal radiotherapy (3D-CRT) treatment plan with regard to head tilting in whole-brain radiotherapy (WBRT) using TomoDirect (TD) mode in Tomotherapy. WBRT 3D-CRT by TD was compared for a total of five head tilt angles (-20°, -10°, 0°. +10° and +20°). The dose homogeneity index (HI) and prescription dose index (CI) were calculated to confirm the target coverage. The maximum and average doses for critical organs such as the lens, eyeball and parotid glands were calculated for different angles of head tilting. The HI and CI were closet to the result value of 1 at the head tilted angle +10° and +20°. At a head tilted angle of +10°, the dose to the lens and eyeballs decreased by about 74% and about 30%, when compared with the reference angle (0°), respectively. The results of this study suggest that a head angle of +10 with chin-up would save adequate target coverage and reduce exposure dose to the lens.

Evaluation of Applicability of Perovskite Dosimeter based on CsPbBr3 Material to Quality Assurance in Radiation Therapy (CsPbBr3을 기반으로 한 Perovskite 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2022
  • In radiation therapy, accurate Quality Assurance (QA) is required to irradiate tumor tissue while minimizing damage to normal tissue. Therefore, a dosimeter that can accurately measure radiation is needed. The purpose of this study is to develop a highly efficient radiation dosimeter with high sensitivity by applying a particle in binder method that can reduce manufacturing costs and simplify processes to perovskite materials that are cheaper and simpler to manufacture. By evaluating the response characteristics to high-energy photon, the applicability of QA dosimeter to radiation therapy was evaluated. As a result of reproducibility evaluation, RSD at 6 MV energy was presented as 1.178% and 15 MV energy was presented as 1.141%. As a result of linearity evaluation according to linear regression analysis, R2 values of 0.9999 were presented under each condition of 6 MV and 15 MV energy. It was found that the CsPbBr3 dosimeter manufactured based on the results of reproducibility and linearity evaluation is highly applicable as a QA dosimeter in the field of therapeutic radiation. The CsPbBr3 dosimeter manufactured in this study presented more than the standard performance in the evaluation of reproducibility and linearity, and it can be used as a radiotherapy QA dosimeter through improvement.

A Cosideration on Physical Aspects in Teleradiotherapy Chart QA (원격방사선치료 기록부의 QA 에서 물리적 측면의 고찰)

  • 강위생;허순녕
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • The aims of this report are to classify the incorrect data of patients and the errors of dose and dose distribution observed in QA activities on teleradiotherapy chart, and to analyze their frequency. In our department, radiation physicists check several sheets of patient chart to reduce numeric errors before starting radiation therapy and at least once a week, which include history, port diagram, MU calculation or treatment planning summary and daily treatment sheet. The observed errors are classified as followings. 1) Identity of patient, 2) Omitted or unrecorded history sheet even though not including the item related to dose, 3) Omission of port diagram, or omitted or erroneous data, 4) Erroneous calculation of MU and point dose, and important causes, 5) Loss of summary sheet of treatment planning, and erroneous data of patient in the sheet, 6) Erroneous record of radiation therapy, and errors of daily dose, port setup, MU and accumulated dose in the daily treatment sheet, 7) Errors leading inexact dose or dose distribution, errors not administerd even though its possibility, and simply recorded errors, 8) Omission of sign. Number of errors was counted rather than the number of patients. In radiotherapy chart QA from Jun 17, 1996 to Jul 31, 1999, no error of patient identity had been observed. 431 Errors in 399 patient charts had been observed and there were 405 physical errors, 9 cases of omitted or unrecorded history sheet, and 17 unsigned. There were 23 cases (5.7%) of omitted port diagram, 21 cases (5.2%) of omitted data and 73 cases (18.0 %) of erroneous data in port diagram, 13 cases (3.2 %) treated without MU calculation, 68 cases (16.3 %) of erroneous MU, 8 cases (2.0%) of erroneous point dose, 1 case (0.2 %) of omitted treatment planning summary, 11 cases (2.7%) of erroneous input of patient data, 13 cases (3.2%) of uncorrected record of treatment, 20 cases (4.9%) of discordant daily doses in MU calculation sheet and daily treatment sheet, 33 cases (8.1%) of erroneous setup, 52 cases (12.8%) of MU setting error, 61 cases (15.1%) of erroneous accumulated dose. Cases of error leading inexact dose or dose distribution were 239 (59.0 %), cases of error not administered even though its possibility were 142 (35.1 %), and cases of simply recorded error were 24 (5.9 %). The numeric errors observed in radiotherapy chart ranged over various items. Because errors observed can actually contribute to erroneous dose or dose distribution, or have the possibility to lead such errors, thorough QA activity in physical aspects of radiotherapy charts is required.

  • PDF

Integration of a Radiotherapy Robot System (방사선 로봇 시스템 통합)

  • Choi, You-Rak;Jeong, Gyoeng-Min;Choi, Young-Su
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.04a
    • /
    • pp.1060-1061
    • /
    • 2017
  • 방사선 로봇 시스템은 X-Ray를 이용하는 로봇 기반 자동 치료 시스템으로 방사선 치료계획 시스템, 방사선가속기, 방사선 치료 로봇, 호홉 추적 시스템, 스마트베드로 구성된다. X-Ray를 이용하는 치료 시스템인 관계로 안정적인 제어가 요구되며, 환자의 호흡에 의한 병소 위치 변위 발생에도 X-Ray를 병소에 정확하게 정량 조사해야한다. 본 논문에서는 방사선 로봇 시스템을 구성하는 서브시스템 간의 데이터 송수신 동기화와 시스템 안정성 확보, 그리고 시스템 통합을 위한 문서 작업을 획기적으로 줄이면서 시스템 통합을 단시간에 수행한 과정에 대하여 기술한다.

Analysis on the Decrease of Planning Target Volume in the Case of Lung Radiation Surgery with the Application of Respiratory Gated Radiotherpy Method (폐암 환자의 방사선수술 시 호흡연동 방사선치료 방법의 적용을 통한 계획용표적체적 감소 효과 분석)

  • Song, Ju-Young;Nah, Byung-Sik;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Yoon, Mee-Sun;Jung, Jae-Uk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.263-268
    • /
    • 2008
  • The application of a respiratory gated radiotherpy method to the lung radiation surgery was evaluated compared with the conventional method in which the whole tumor motion range is considered in the delineation of PTV (Planning target volume). The four dimensional CT simulation images were acquired for the five NSCLC (Non-small cell lung cancer) patients for radiation surgery. The respiratory gated plan was prepared with the 50% phase CT images and the conventional method was planned based on the ITV (Internal target volume) which include all the target volumes created in each phase CT images within a whole respiratory period. The DVH (Dose volume histogram) of OAR (Organ at risk) which calculated in each method was compared for the evaluation of the plan properness. The relative decrease of OARs' DVH were verified in the application of respiratory gated method. The average decrease rate were $16.88{\pm}9.97%$ in the bronchus, $34.13{\pm}19.15%$ in the spinal cord, $28.42{\pm}18.49%$ in the chest wall and $32.48{\pm}16.66%$ in the lung. Based on these results, we can verified the applicability and the effectiveness of the respiratory gated method in the lung radiation surgery.

  • PDF

Assessment of Radiation Dose for Surrounding Organs and Persons Approaching Patients upon Brachytherapy of Cervical Cancer with $^{192}Ir$ ($^{192}Ir$를 사용한 자궁경부암 치료시 주변 장기 및 근접한 사람의 선량 평가)

  • Kang, Se-Sik
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.283-288
    • /
    • 2010
  • In order to evaluate radiation dose on the uterus and surrounding organs during brachytherapy for cervical cancer, of which the frequency of occurrence is high in Korean women, as well as radiation dose on medical staffs in proximity of patients receiving the therapy, a mathematical phantom based on reference Korean was established and the radiation dose was calculated accordingly. For simulation, $^{192}Ir$, which is useful in brachytherapy, was selected as radionuclide. Also, it was presumed that the intensity of initial radiation was 1 Ci. The result indicated the radiation of 4.92E-14 Gy/Ci in the uterus, the source organ. In addition, radiation on people around patient receiving the therapy was found to be 1.24E-07 Sv at a distance of 30 cm.

Comparison of Practical Usefulness of Respirational Radiation Treatment Using Geant 4 Simulation Code (Geant 4 시뮬레이션 코드를 이용한 호흡 동조 방사선치료의 유용성 비교)

  • Jang, Eun-Sung;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.637-643
    • /
    • 2019
  • To verify internal movements of the body, a DICOM file obtained from CT and a Geant4 code were used to simulate lung cancer patients. In addition, the method is applied to measure the movement of tumor when the movement of t he tumor is located inhale and exhale by creating a virtual tumor in the self-produced moving phantom, and to check the distribution of dose in the treatment plan and the accuracy of tumor in PTV for respiratory and lung cancer patients. It was confirmed that 97% or more respiratory control radiation therapy was effective even if the moving area was more than 3cm, in the 40% to 70% range. Dose distribution with respiratory radiation therapy applied to moving targets, measured by film in the actuation phantom, was shown to be within a 3mm margin of error for dose distribution containing 90%. It was confirmed that for actual patient breathing curves, the treatment time may be shorter than that due to the longer expiratory time.

Usefulness Evaluation on the Treatment Plan of Tomotherapy and VMAT in Radiotherapy for Prostate Cancer (전립선암의 방사선치료에서 토모테라피와 VMAT의 치료계획에 따른 유용성 평가)

  • Heo, Kwangmyoung;Han, Jaebok;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.449-457
    • /
    • 2015
  • In this study, to evaluate the usefulness of the treatment plan of tomotherapy and volumetric modulated arc therapy (VMAT) in the radiotherapy for prostate cancer, the absorbed dose, dose volume histogram (DVH), treatment efficiency, and the results of dose verification accuracy using MapCHECK2 were compared and analyzed. Of the prostate cancer patients who underwent tomotherapy treatment in the Radiologic Oncology of H University Hospital between July 2014 and December 2014, 12 patients were randomly selected. As a result of analyzing the absorbed dose and DVH, both radiologic treatment plans showed slight differences in the treatment of the cancer tissues and the bladder, but the difference was in the error range of -5% to +3%, and did not exceed the side effect guideline or the tolerance dose limit. VMAT showed higher treatment efficiency than tomotherapy with a 2.5 times shorter treatment time and a 10.3 times less monitor unit (MU). Both showed 95% or higher dose accuracy satisfying the standard. VMAT showed 2.3% higher efficiency than tomotherapy. In both tomotherapy and VMAT, appropriate doses were absorbed for cancer tissues, and did not exceed the tolerance dose for normal tissues showing no significant difference in dose distribution. However, considering the shorter treatment time, lower total MU, and better treatment efficiency and dose verification accuracy, VMAT may be more useful than tomotherapy in cancer treatments.