• 제목/요약/키워드: 하중제어

Search Result 689, Processing Time 0.024 seconds

Influence of Strain-Hardening Cement Composite's Tensile Properties on the Seismic Performance of Infill Walls (변형경화형 시멘트 복합체의 인장성능에 따른 끼움벽의 내진성능)

  • Cha, Jun-Ho;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.1
    • /
    • pp.3-14
    • /
    • 2012
  • This paper describes experimental results on the seismic performance of SHCC (strain-hardening cement composite) infill wall for improving damage tolerance capacity of non-ductile frame. To investigate the effect of tensile strain capacity and cracking behavior of SHCC materials on the shear behavior of SHCC infill wall, three infill walls were fabricated and tested under cyclic loading. The test parameter in this study is a type of cement composites; concrete and SHCCs. The two types of SHCC materials were prepared for infill walls. In order to induce crack damages into the mid-span of the infill wall, each infill wall had two 100-mm-deep-notches on both sides. Test results indicated that SHCC infill walls showed superior crack control capacities and much larger drift ratios at the peak loads than RC (reinforced concrete) infill wall, as expected. In particular, due to the bridging actions of the reinforcing fibers, SHCC matrix used in this study would delay the stiffness degradation of infill wall after the first inclined cracking. Moreover, from the damage classes based on the cracks' maximum width in the infill walls, it was observed that PIW-SHD specimen possessed nearly threefold seismic capacities compared to PIW-SLD specimen. Also, from the results on the strain of diagonal reinforcements, it can be concluded that the SHCC matrix would resist a part of tensile stresses transferred along steel rebar in the infill wall.

Indentation of YSZ/Al2O3 Layered Systems Prepared by Nano-Coating (알루미나에 YSZ가 나노코팅된 층상형 시스템의 인덴테이션 특성평가)

  • Kim, Sang-Kyum;Kim, Tae-Woo;Kim, Chul;Shin, Tae-Ho;Han, In-Sub;Woo, Sang-Kuk;Lee, Kee-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • YSZ layer containing nano-sized particles has been deposited on the commercial A1203 substrate by Electron Beam Physical Vapor Deposition (EB-PVD). The role of coating rnjcrostructures of YSZ to indentation damage is studied. The different coating microsouctures are prepared by varying the substrate temperatures from $600^{circ}C$ to $800^{circ}C$ during the deposition. Microhardness test and Hertzian indentation are conducted on the $YSZ/Al_{2}O_{3}$ layered systems. The damage and flilure behaviors have been investigated according to the effect of microstructures and indentation loads. With increasing the substrate temperature during EB-PVD, the overall grain sizes are coarser and more faceted, which microsoucture ultimately influences on the indentation behavior, thus, YSZ/Al_{2}O_{3}$ layered system prepared at the substrate temperature of $800^{circ}C$ shows relatively higher damage tolerance.

Development of Structural Reliability Analysis Platform of FERUM-MIDAS for Reliability-Based Safety Evaluation of Bridges (신뢰도 기반 교량 안전성 평가를 위한 구조신뢰성 해석 플랫폼 FERUM-MIDAS의 개발)

  • Lee, Seungjun;Lee, Young-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.884-891
    • /
    • 2020
  • The collapse of bridges can cause massive casualties and economic losses. Therefore, it is thus essential to evaluate the structural safety of bridges. For this task, structural reliability analysis, considering various bridge-related uncertainty factors, is often used. This paper proposes a new computational platform to perform structural reliability analysis for bridges and evaluate their structural safety under various loading conditions. For this purpose, a software package of reliability analysis, Finite Element Reliability Using MATLAB (FERUM), was integrated with MIDAS/CIVIL, which is a widely-used commercial software package specialized for bridges. Furthermore, a graphical user interface (GUI) control module has been added to FERUM to overcome the limitations of software operation. In this study, the proposed platform was applied to a simple frame structure, and the analysis results of the FORM (First-Order Reliability Method) and MCS (Monte Carlo simulation), which are representative reliability analysis methods, were compared. The proposed platform was verified by confirming that the calculated failure probability difference was less than 5%. In addition, the structural safety of a pre-stressed concrete (PSC) bridge was evaluated considering the KL-510 vehicle model. The proposed new structural reliability analysis platform is expected to enable an effective reliability-based safety evaluation of bridges.

An Experimental Study on Flexural Behavior of Steel Fiber Reinforced Ultra High Performance Concrete Prestressed Girders (강섬유 보강 초고성능 콘크리트 프리스트레스트 거더의 휨거동 실험 연구)

  • Yang, In-Hwan;Joh, Chang-Bin;Kim, Byung-Suk
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.777-786
    • /
    • 2010
  • This paper examines the flexural behavior of full-scale prestressed concrete girders that were constructed of steel fiber reinforced ultra high performance concrete (UHPC). This study is designed to provide more information about the bending characteristics of UHPC girders in order to establish a reasonable prediction model for flexural resistance and deflection for future structural design codes. Short steel fibers have been introduced into prestressed concrete T-girders in order to study their effects under flexural loads. Round straight high strength steel fibers were used at volume fraction of 2%. The girders were cast using 150~190 MPa steel fiber reinforced UHPC and were designed to assess the ability of steel fiber reinforced UHPC to carry flexural loads in prestressed girders. The experimental results show that steel fiber reinforced UHPC enhances the cracking behavior and ductility of beams. Moreover, when ultimate failure did occur, the failure of girders composed of steel fiber reinforced UHPC was observed to be precipitated by the pullout of steel fibers that were bridging tension cracks in the concrete. Flexural failure of girders occurred when the UHPC at a particular cross section began to lose tensile capacity due to steel fiber pullout. In addition, it was determined that the level of prestressing force influenced the ultimate load capacity.

A numerical study of pillar reinforcing effect in underground cavern underneath existing structures (지하공간하부 지하저류공동에서의 필라 보강효과에 관한 수치해석적 연구)

  • Seo, Hyung-Joon;Lee, Kang-Hyun;Han, Shin-In;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.5
    • /
    • pp.453-467
    • /
    • 2012
  • Usage of underground space is increasing at metropolitan city. More than 90% of flood damages have occurred at downtown of metropolitan cities. In order to prevent and/or minimize the flood-induced damage, an underground rainwater detention cavern was proposed to be built underneath existing structures. As for underground caverns to be built for flood control, multi-caverns will be mostly adopted rather than one giant cavern because of stability problem. Because of the stress concentration occurring in the pillars between two adjacent caverns, the pillar-stability is the Achilles' heel in multi-caverns. So, a new pillar-reinforcing technology was proposed in this paper for securing the pillar-stability. In the new pillar-reinforcing technology, reinforced materials which are composed of a steel bar and PC strands are used by applying pressurized grouting, and then, by applying the pre-stress to the PC strands and anchor body. Therefore, this new technology has an advantage of utilizing most of the strength that the in-situ ground can exert, and not much relying on the pre-cast concrete structure. The main effect of the pressurized grouting is the increase of the ground strength and more importantly the decrease of stress concentration in the pillar; that of the pre-stress is the increase of the ground strength due to the increase of the internal pressure. In this paper, ground reinforcing effects were verified the stress change in pillar is obtained by numerical analysis at each construction stage. From these results, the effects of pressurized grouting and pre-stress are verified.

Stiffness evaluation of elastomeric bearings for leg mating unit (LMU용 일래스토머릭 베어링의 강성평가)

  • Han, Dong-Seop;Jang, Si-Hwan;Lee, Kwon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.106-111
    • /
    • 2017
  • In this study, the stiffness of an LMU (Leg Mating Unit), which is a device required for installing the top side part of an offshore structure, was examined through structural analysis. This unit is mounted on the supporting point of the structure and is used to absorb the shock at installation. It is a cylindrical structure with an empty center. To support the vertical load, elastomeric bearings (EBs) and iron plates are laminated in layers. The stiffness of the EBs is basically influenced by the size of the bearings, but it varies with the number of laminated sheets inside the same sized structure. The relationship between the stiffener and the compressive stiffness is investigated, and its design is suggested. The stiffness of the EBs is analyzed by calculating the reaction force, while controlling the displacement. First, the relationship between the size of the reinforcing plate and the compressive stiffness is considered. Next, the relationship between the number of stacked reinforcing plates and the compression stiffness is considered. Different loads are required for each installed point. The goal is to design the compression stiffness in such a way that the same deformation occurs at each point in the analysis. In this study, ANSYS is used to perform the FE analysis.

Experimental Curvature Analysis of Reinforced Concrete Piers with Lap-Spliced Longitudinal Steels subjected to Seismic Loading (지진하중을 받는 주철근 겹침이음된 철근콘크리트 교각의 곡률분석)

  • Chung, Young-Soo;Park, Chang-Kyu;Song, Hee-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.41-49
    • /
    • 2006
  • Through the 1982 Urahawa-ohi and the 1995 Kobe earthquakes, a number of bridge columns were observed to develop a flexural-shear failure due to the bond slip as a consequence of premature termination of the column longitudinal reinforcement. Because the seismic behavior of RC bridge piers is largely dependent on the performance of the plastic hinge legion of RC bridge piers, it is desirable that the seismic capacity of RC bridge pier is to evaluate as a curvature ductility. The provision for the lap splice of longitudinal steel was not specified in KHBDS(Korea Highway Bridge Design Specification) before the implementation of 1992 seismic design code, but the lap splice of not more than 50%, longitudinal reinforcement was newly allowed in the 2005 version of the KHBDS. The objective of this research is to investigate the distribution and ductility of the curvature of RC bridge column with the lap splice of longitudinal reinforcement in the plastic hinge legion. Six (6) specimens were made in 600 mm diameter with an aspect ratio of 2.5 or 3.5. These piers were cyclically subjected to the quasi-static loads with the uniform axial load of $P=0.1f_{ck}A_g$. According to the slip failure of longitudinal steels of the lap spliced specimen by cyclic loads, the curvatures of the lower and upper parts of the lap spliced region were bigger and smaller than the corresponding paris of the specimen without a lap splice, respectively. Therefore, the damage of the lap spliced test column was concentrated almost on the lower part of the lap spliced region, that appeared io be failed in flexure.

Base Isolation of the 1/3 Scaled RC Building with the Laminated Rubber Bearings (적층고무형 면진 장치를 갖는 철근콘크리트 건물의 면진 특성)

  • Chang Kug-Kwan;Chun Young-Soo;Kim Dong-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.975-982
    • /
    • 2005
  • Scientific community agrees about the fact that base Isolation provides interesting solutions to minimize the seismic risk. Reliability of such a technique is nowadays proofed by a large number of applications like public buildings, nuclear plants, bridges, etc. This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by enterprise in Korea. The shaking table tests were performed using a three story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Especially in this study, effect of earthquake characteristics on response reduction and effect of the intensity of excitations are studied. Through the verification tests, the validity of the applied base isolaion device and the response reduction effect against earthquakes are confirmed.

Rotor Hub Vibration Reduction Analysis Applying Individual Blade Control (개별 블레이드 조종을 통한 로터 허브 진동 저감 해석)

  • Kim, Taejoo;Wie, Seong-Yong;Kim, Minwoo;Lee, Dong-geon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.8
    • /
    • pp.649-660
    • /
    • 2021
  • Through analytical method based on S-76 model, the level of rotor hub vibration reduction was analyzed according to higher harmonic actuating by individual blade control. The higher harmonic actuating method for individual blades was divided into a method of generating an additional actuating force from the pitch-link in the rotating part and generating actuating force through the active trailing edge flap control of the blade. In the 100kts forward flight conditions, the hub load analysis was performed by changing the phase angle of 15 degree for the 2P/3P/4P/5P harmonic actuation for individual blades. Through the harmonic actuation results, the sensitivity of the rotor system according to the actuating conditions was analyzed, and the T-matrix representing the characteristics of the rotor system was derived based on this analysis result. And through this T-matrix, optimal higher harmonic actuating condition was derived to minimize hub vibration level for flight condition. In addition, the effect on the performance of the rotor system and the pitch-link load under minimum hub vibration condition, as well as the noise influence through the noise analysis were confirmed.

Evaluation of Pull-out Performance of Torsion Control Expansion Anchor According to Drill Bit Diameter (드릴비트 직경에 따른 비틀림 제어 확장 앵커의 인발성능 평가)

  • Kyoung-Hun Chae;Tae-Wo Park;Moo-Won Hur;Yeong-Seung An;Ju-Yeon Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.1
    • /
    • pp.64-70
    • /
    • 2023
  • In this study, reliability tests of torsion control expansion anchors according to drill bit diameters were performed. The standard deviation and coefficient of variation of the anchor were reviewed through the tests for each variable, and the results were compared and evaluated with the standard test results. As a result of the reliability test of the M12 and M16 anchors with 1.04 times the drill bit diameter, they were within 20% of the ultimate tensile load permissible standard coefficient of variation. It was found that the pulling-out performance of the anchor installed in the large hole was sufficiently secured. However, it was found to be about 253% and 210% of the design strength, indicating that the pulling performance of the anchor installed in 1.04 times the drill bit diameter was sufficiently secured. As a result of the reliability test of the M12 and M16 anchors with 1.02 times the drill bit diameter, the value of the coefficient of variation of the ultimate tensile load limit was within 20%, which satisfies the test standard. It was shown to be about 136% and 168% of the design strength, indicating that the pulling-out performance of the anchor installed in 1.02 times the drill bit diameter is sufficiently secured.