Browse > Article
http://dx.doi.org/10.4334/JKCI.2005.17.6.975

Base Isolation of the 1/3 Scaled RC Building with the Laminated Rubber Bearings  

Chang Kug-Kwan (School of Architectural Engineering, Seoul National University of Technology)
Chun Young-Soo (Housing and Urban Research Institute, Korea National Housing Corporation)
Kim Dong-Young (Dong-il Rubber Belts)
Publication Information
Journal of the Korea Concrete Institute / v.17, no.6, 2005 , pp. 975-982 More about this Journal
Abstract
Scientific community agrees about the fact that base Isolation provides interesting solutions to minimize the seismic risk. Reliability of such a technique is nowadays proofed by a large number of applications like public buildings, nuclear plants, bridges, etc. This paper reports the results of performance verification tests of the base isolated RC building with the laminated rubber bearings which is manufactured by enterprise in Korea. The shaking table tests were performed using a three story model scaled to 1/3 of the prototype RC apartment building. Several major earthquake records were scaled to different peak ground accelerations and used as input base excitations. Especially in this study, effect of earthquake characteristics on response reduction and effect of the intensity of excitations are studied. Through the verification tests, the validity of the applied base isolaion device and the response reduction effect against earthquakes are confirmed.
Keywords
base isolation; laminated rubber bearing; reinforced concrete building; shaking table test;
Citations & Related Records
연도 인용수 순위
  • Reference
1 日本コム協曾, 免震用積層コムの 利用技術の關の硏究報告書(2),日本コム協曾, 1995
2 無田水一, 建築物의 免震, 防震, 制震, 技報堂出版, 1988, pp.1985-1988
3 장극관외 18인, 'RC건물의 면진기법 적용을 위한 설계 지침서 작성 및 실용화연구', 대한건축학회, 대한주택공사. DRB 동일. '2002
4 EI-Atter, A. G., 'White, R. N., and Gergely, P., Shake Table Test of a 1/8 Scale Three-Story lightly Reinforced Concrete Building, Technical Report NCEER-91-0081, Comell University, 1991, pp.2-1-2-5
5 대한건축학회, 건축물의 하중기준 및 해설, 대한건축학회 , 2000, 354pp
6 이현호, 한상환, 이리형, '지진위험도를 고려한 설계지 진기록 선정', 대한건축학회 논문집, 16권 9호, 2000, pp.37-44
7 ICBO, Uniform Building Code: Structural Engineering Design Provision, Vol.2, Whitter, CA, 1997, pp.405-412
8 日本建築學曾, 免震構造設計指針,日本建築學曾, 1993
9 Naeim, F. and Kelly, J. M., Design of Seismic isolated Structures, John Wiley & Sons, Inc., 1999, 289pp
10 Skinnerrn R. I., Robinson, W. H., and Mcverry, G. H., An Introduction to Seismic Isolation, John Wiley & Sons, Inc., 1992, 304pp