• Title/Summary/Keyword: 하중전달

Search Result 585, Processing Time 0.023 seconds

Tensile Strength on Connection Socket of Cables (케이블 연결 소켓의 인장강도)

  • Park, Kang-Geun;Lee, Jang-Bok;Ha, Chae-Won;Kim, Jae-Bong
    • Proceeding of KASS Symposium
    • /
    • 2008.05a
    • /
    • pp.37-42
    • /
    • 2008
  • Cable member in structure is tension systems in which the load carrying members transmit loads to support system by tensile stress with no compression or flexure allowed. Cable system have been widely used large span structure roof, air-supported structure, prestressed membrane, cable network roof, suspension structures, guyed tower, ocean platforms, suspension bridges. Cable member can transmit loads by the edge connected system such as socket, swaging, mechanical splice sleave, clip, wedge, loop splice etc. This study will shown an experimental results on the strength of connection socket of cables. In the results of experiment, most of cable connection specimen occurred the failure at the connection socket part before the cable arrived at tensile failure load.

  • PDF

Molecular Dynamics Study on Mechanical Behavior and Load Transfer of CNT/PET Nanocomposites : the Effects of Covalent Grafting (탄소나노튜브/폴리에스터 복합재의 역학적 거동과 하중전달에 관한 분자 동역학 전산모사 : 그래프팅 가공의 영향)

  • Jin, Juho;Yang, Seunghwa
    • Composites Research
    • /
    • v.30 no.3
    • /
    • pp.193-201
    • /
    • 2017
  • Molecular dynamics simulation and the Mori-Tanaka micromechanics study are performed to investigate the effect of the covalent grafting between CNT and polyester on the mechanical behavior and load transfer of nanocomposites. The transversely isotropic stress-strain curves are determined through the tension and shear simulations according to the covalent grafting. Also, isotropic properties of randomly dispersed nanocomposites are obtained by orientation averaging the transversely isotropic stiffness matrix. By addressing the grafting, the transverse Young's modulus and shear moduli of the nanocomposites are improved, while the longitudinal Young's modulus decreases due to the degradation of the grafted CNT.

Study on Fire Resistance of H-Section Beams Filled with Concrete at Web (웨브 보강 형태에 따른 H형강 보부재의 내화성능에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.76-84
    • /
    • 2011
  • Steel beams are one of primary member and those carries the horizontal load and floor load to axial member. To avoid structural failure when the steel beams are exposed to fire, fire resistance performance requires. Till now, the evaluation for fire resistance of the beam was conducted using the maximum load and standard fire curve defined in the KS F 2257. But recently the constructional patterns are changing toward multi-function performance to get a better structural performance and fire resistance as well. In this paper to get the databases for fire resistance, limiting temperatures of the beam, load-bearing fire tests according to load ratios, two grades of compressive concrete strengths were applied.

Performance Verification and Reliability Test of Load Cell Gauge in Korea (국내 하중계 성능검증과 신뢰성 시험 연구)

  • Kim, Yeong-Bae;Park, Yeong-Bae;Lee, Seong-Won;Lee, Kang-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.103-114
    • /
    • 2023
  • Monitoring the site of an underground construction wall is crucial to confirm the stability of the supports and ground due to excavation. In particular, it is essential to maintain the accuracy of a load cell gauge, which identifies the load of the support transmitted from the excavated ground. However, research on verification methods and regulations that can identify the accuracy of load cell gauges at construction sites is inadequate, which is a problem as load cell gauges are installed without proper performance inspections. In this study, performance tests were conducted by a complete investigation of load cell gauges sold in Korea and comparing them with foreign products to determine defect causes. In addition, the criteria for selecting a load cell gauge were presented, and the results of this study were considered to help select a highly reliable load cell gauge.

Analytical Study on Strength Resistance of Steel Beams with Stiffened Ends by Reinforced Concrete -difference of behavior with fixing plate- (복합보의 내력성능에 관한 연구 -정착판의 설치에 의한 거동의 차이-)

  • Kim, Seong Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.681-690
    • /
    • 2000
  • Recently, a long span is often required for the spacious building. Therefore the increase of stiffness is necessary to prevent floor vibration and control deformation of the building under earthquake and wind loads. For this purpose, steel beams with stiffened ends by reinforced concrete are effective. To realize such an effective reinforcement method, the smoothening of bending and shear stress transmission at the boundaries between middle-part of the steel beam and both end-parts of the steel beam with stiffened ends by reinforced concrete is required. Therefore, the fixed plate was installed at the boundary with the view of transferring the stress smoothly. This paper evaluates the method of effective transmission of bending and shear stress through the numerical analysis that is based on advanced experimental tests.

  • PDF

A Study on the Anti-impulsive Strength of the Helmets for a Gas Industry (가스산업용 안전모의 내충격 안전성에 관한 연구)

  • Kim, Chung Kyun;Kim, Tae Whan
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.52-57
    • /
    • 2013
  • In this study, the strain energy density, stress and deformation behaviors have been analyzed as functions of a thickness and a force area of protective helmets with and without an extruder on the top of the shell structure using the finite element method. The strain energy density in which is related to the absorption capacity of an impact energy transfer is one of a key element of the helmet safety. The FEM analyzed results show that when the impulsive force of 4,540N is applied on the top surface of the helmets, the maximum stress is linearly reduced for an increased area of impact forces. But, the maximum strain energy density has been reduced for the increased force area. The reduced strain energy density may increase the impulsive forces transferred to the head and neck of helmet wearers, which may decrease the impact energy absorption safety of the helmets. In thus, it is safer design of the helmet in which has an extruded structure on the summit surface, but the modified helmet may decrease the impact energy absorption capacity.

Development and Performance Test for Unbonded Post-Tensioned Anchor (비부착 강연선에 대한 포스트텐션 정착구 개발 및 성능 시험)

  • Cho, Ah Sir;Jo, Yeong Wook;Jeon, Byong Kap;Kang, Thomas H.K.
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.11-20
    • /
    • 2015
  • An unbonded post-tensioned anchor using a 15.2 mm diameter 7-wire strand was developed based on finite element analysis and experimental testing. In order to evaluate its performance, static load tests and load transfer tests were conducted following KCI-PS101. The static load tests and additional strand tensile tests confirmed that the developed anchor had a capacity more than nominal tensile strength of a 7-wire strand without any damage or deterioration. According to the result of load transfer tests for many different reinforcing details, specimens with no additional reinforcing bars sustained at least 1.64 times the nominal tensile strength of the strand.

An Estimation of the Fatigue Behavior on the Cruciform Type Specimen by Variation of the Stress Ratio (응력비 변화에 따른 십자형 접합부의 피로거동 평가)

  • 김태봉;서상구;우상익
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.1
    • /
    • pp.140-145
    • /
    • 2000
  • This paper was composed with fatigue test of the cruciform specimens, as load carrying and non-load carrying type. It also has performed computational analyses for geometric condition of the fillet welding bead. As test results, the effect of stress ratio in the specimen was insignificant. Stress ranges were varied with R=0.1~0.2. The fatigue cracks that were found in the load carrying type specimens and most specimens welded with contact were developed at the end of welds. The fatigue strength of specimen that have fractured in maternal plate was found about ${\Delta}\sigma_c$=63.5MPa. It's about 24% less than that of the non-load carrying type specimens having about ${\Delta}\sigma_c$=83.8MPa. A category of the Fatigue design specifications which provide for cruciform details was defined grade C as a stress of the maternal member. And then, the fatigue strength to be transformed into the maternal stress was found about 78.27 MPa, it tends to be less than that of allowable fatigue strength.

  • PDF

An Experimental Study on the Bond Strengths for Concrete Filled Steel Tube Columns using a Push-Out Test (단순가력실험을 통한 콘크리트충전 강관기둥의 부착응력에 관한 연구)

  • Woo, Hae Sung;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.481-487
    • /
    • 2002
  • Currently, the load transfer's mechanism from a beam to a column has yet to ve clarified in a concrete filled steel tubular (CFT) structure with a connection type of an exterior diaphragm. The loads for each floor are transferred to the concrete core from a steel beam through ha contacted face between an in-filled concrete and the interior surface of a steel tube. Thus, a Push-Out test was performed to investigate the load transfer mechanism. A total of 30 samples were tested to confirm the bond stress and/or axial load distribution between a steel tube and in-filled concrete for CFT column. The main parameters considered for this study included concrete type, steel tube-shape/length, and the effect of a weld joint wit ha backing strip for a column splice. Test results were summarized to confirm load transfer behavior between a concrete and steel tube for each experimental parameter, using the analytical approach to verify experimental results.

Study on Analysis of Skew Grillage Girder Bridges by Transfer Matrix Method (전달행렬법에 의한 경사 격자교의 해석에 관한 연구)

  • Kim, Yong-Hee;Lee, Yoon-Young;Kim, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.1
    • /
    • pp.159-170
    • /
    • 2005
  • The grid structure is parallel main girders intersected with crossgirder. It distribute the loads to adjoining main girder through the crossgirder when a girder is subjected to a load. grillage girder bridge has high load-carrying capacity, it can save materials and become more economical type of bridge. In this paper, the grillage girder bridge analysis program developed by using the transfer matrix method deals with following problems: the comparision with Leonhardt, Szabo, FEM yang and jung in the analysis of grillage girder bridges, quality of straight and curved bridges with skew angle, forces of straight and curved bridges according to skew angle and bending stiffness/torsional stiffness ratio.