• Title/Summary/Keyword: 하악전방 이동장치

Search Result 29, Processing Time 0.023 seconds

The Influence of the Amount of Mandibular Advancement in the Application of Mandibular Advancement Device for Obstructive Sleep Apnea Patients (폐쇄성수면무호흡증 환자의 하악전방이동장치 적용에 있어서 전방이동량이 미치는 영향)

  • Kim, Young-Kyun;Yoon, In-Young;Kim, Jeong-Whun;Lee, Chul-Hee;Yun, Pil-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.18 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • Objectives: The purposes of this study were to estimate the effect of mandibular advancement device (MAD) and to evaluate the influence of the advancement amount of mandible in the application of MAD for obstructive sleep apnea (OSA) patients. Methods: From the patients who were diagnosed as OSA by polysomnographic study at Seoul National University Bundang Hospital from January 2007 to February 2009, the patients who chose MAD as treatment option were included in this study. All the patients’ data including clinical records and polysomnographic studies (both pre- and post-treatment) were reviewed and analyzed. Results: Successful results were obtained in 65 patients of 86 patients (75.6%). In the follow-up period, mild discomfort of anterior teeth or temporomandibular joint (TMJ) were described in 28 patients, especially in the cases the amount of mandibular advancement were more than 7.0 mm. There was no direct relationship between the amount of mandibular advancement and clinical outcome. Conclusion: MAD was effective treatment option for the OSA patients regardless of severity. For the prevention of potential dental complications, the amount of mandibular advancement should be considered at the time of MAD treatment.

EFFECT OF PULSING ELECTROMAGNETIC FIELDS COMBINED WITH ANTERIOR MANDIBULAR DISPLACEMENT ON CONDYLAR GROWTH IN THE RAT (맥동 전자기장과 하악골 전방이동이 백서의 하악과두 성장에 미치는 영향에 관한 실험적 연구)

  • Yang, Sang-Duk;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.20 no.3 s.32
    • /
    • pp.463-498
    • /
    • 1990
  • 전기적 자극에 의한 골성장기전의 개념을 이용하여 임상적 효율성을 증진시키기 위한 연구는 현재 교정학을 비롯한 치과영역에서 활발히 진행되고 있는 분야 중의 하나이다. 전기적 자극의 여러 형태 중의 하나인 전자기장과 하악의 기능적 전방 이동을 유도하는 악기능교정장치가 백서의 하악과두 성장에 미치는 영향을 구명하기 위하여 본 연구를 시행하였다. 생후 4주된 Sprague Dawley계 백서 48마리를 대조군 12마리, 실험군 36마리로 나누고, 실험군은 다시 전자기장을 가한 군, 하악골 전방이동 장치를 장착시킨 군, 전자기장과 하악골 전방이동 장치를 병용시킨 군으로 분류하여 각각 12마리씩 실험동물을 배정하였다. 각 군의 실험동물은 15 HZ의 특수 전자기장이나 하악전방이동 자치가 하루10시간씩 작용되도록 특별히 제작한 실험장치 속에 넣어 1주간, 4주간씩 사육하여 희생시킨 후 하악골을 분리하고 연조직을 박리한 후 $10\%$ formalin에 보관하였다. 하악골 길이를 측정하기 위해 0.05mm까지 계측 가능한 캘리퍼를 이용하여 하악과두의 후연에서 이공까지의 거리를 계측하였고, 하악과두를 절제하여 0.5M EDTA에 탈회시켜 파라핀 포매를 하였다. 표본의 절단방향은 시상평면에 평행하게 하여 $6{\mu}m$두께로 연속절단 하였으며, 그 중 중심의 3절편을 취하여 통법에 의한 H-E 중염색을 시행하였다. 하악골 계측과 H-E 중염색 표본을 통한 조직학적 관찰을 통해 다음과 같은 결론을 얻었다. 1. 4주군에서 전자기장만에 노출된 실험군은 대조군에 비해 하악골 길이가 유익성 있게 증가되었다. 2. 전자기장과 하악골 전방이동 장치를 병용한 실험군은 하악골 전방이동장치만을 사용한 실험군에 비하여 하악골 길이가 증가되었다. 3. 전자기장에 노출된 실험군은 전구 연골아세포(prechondroblast)의 증식, 비대연골 세포층의 세포간질 및 연골내 골화층의 석회화가 모두 증가되었다. 4. 본 실험에 사용한 15 HZ전자기장의 주요작용부위는 백서의 하악과두 성장지역 중 연골내 골화의 석회화 지역이며, 또한 이는 하악골 전방이동 장치와 병용시 하악과두 성장을 촉진시킬 수 있음이 관찰되었다.

  • PDF

Effect of MAD Snoring Design on Pharyngeal Airway Dimension (하악전방이동 코골이 장치의 수직 교합량이 상기도에 미치는 영향)

  • Ra, In-Sil;Lee, Jang-Hoon
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.307-314
    • /
    • 2017
  • In this study, a minimum amount of the vertical occlusion was secured differently in each type of mandibular advance devices snoring and Class I malocclusion patients wore these devices. This study analyzes, after the use of devices, a different amount of the vertical occlusion results in a change of the area of upper airway by additional changes such as mandibular position, muscle changes, tongue position. The higher the vertical amount, the area of the upper airway was shown smaller, And if the patient's tongues was prevented from the distal movement, the area of the upper airway had increased, To reduce snoring, doctors should accurately diagnose patients' occlusal relationships and select a MAD snoring that is appropriate for the occlusion. The dental technician who builds the selected device should also consider design settings such as the amount of vertical occlusion, the finish lines, and the thickness of the device to increase the effectiveness of the device.

Treatment Outcome of Mandibular Advancement Device in Obstructive Sleep Apnea Patients- Polysomnographic and Cephalometric analyses (수면무호흡증 환자에서 수면다원검사와 두부규격방사선사진을 이용한 하악전방이동장치의 치료효과에 관한 연구)

  • Chung, Jin-Woo;Kim, Ebee;Kim, Sung-Hun
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.203-213
    • /
    • 2013
  • Objecives : The purpose of the study was to evaluate treatment outcome of mandibular advancement device(MAD) in obstructive sleep apnea (OSA) patients using full night polysomnography and cephalometry. Methods : Twenty-seven OSA patients were confirmed by full night, lab-attended polysomnography. Cephalometric examinations were conducted to obtain SNA, ANB, $AH{\bot}MP$, AH-C3, SPT, PNS-U, NAS, SOAS, MOAS, and HAS. Mandibular advancement devices (MADs) were fabricated and delivered for all subjects. After acclimation period of MAD, the second polysomnographic examinations were conducted in the same manner. Polysomnographic variables were compared between before and after MAD placement. Also, correlation coefficients were calculated between apnea-hypopnea index (AHI) and each item of cephalometric parameters. Results : There were significant improvements in total AHI, lowest $SpO_2$, and total arousal index after MAD therapy. Also, there were significant improvements in NREM $SpO_2$ and NREM AHI, but not in REM $SpO_2$ and REM AHI with MAD. Stratifying the sleep stage, there were significant decrease in stage I and significant increases in stage II and REM, but change in stage III was not significant. SNA and SOAS were significantly correlated with total AHI and NAS was significantly correlated with supine AHI. ANB was significantly associate with the effect of MAD. Conclusions : MAD is an effective treatment in OSA patients comparing polysomnographic variables before and after treatment. Cephalometric examination can be useful to evaluate OSA patients and predict treatment outcome of MAD.

Safety and Efficacy of the Mandibular Advancement Device 'Bioguard' for the Treatment of Obstructive Sleep Apnea : A Prospective, Multi-Center, Single Group, and Non-Inferiority Trial (폐쇄성 수면무호흡증의 치료에 사용되는 하악전방이동장치-'바이오가드'의 안전성과 유효성 검증을 위한 전향적, 다기관, 단일군 및 비열등성 연구)

  • Kim, Hyoung Wook;Hwang, Chungpoong;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.23 no.2
    • /
    • pp.84-92
    • /
    • 2016
  • Objectives: The purpose of this study was to estimate the safety and efficacy of a mandibular advancement device (MAD), 'Bioguard,' for the treatment of obstructive sleep apnea (OSA). Methods: In this 5-week prospective, multi-center, single group, and non-inferiority trial, patients who chose 'Bioguard' as their treatment option were evaluated using both questionnaires (Pittsburgh Sleep Quality Index (PSQI), Epworth sleepiness scale (ESS)) and polysomonography (PSG) (apnea hypopnea index (AHI), oxygen saturation). All patient data, including clinical records, PSG studies (both pre- and post-treatment), and adverse events (AEs), were reviewed and analyzed. Results: Results were obtained for 59 of 62 patients (95.16%). No significant difference in success rate was found between the MAD treatment and surgical treatment (95% CI). AHI, PSQI, ESS and oxygen saturation demonstrated significant improvement (p < 0.001) after MAD treatment, and 39 of 62 patients (62.9%) reported 85 AEs. 79 of the 85 AEs (91.8%) were mild cases, and there were no severe AEs related to the MAD treatment. Conclusion: The MAD 'Bioguard' should be considered as an alternative treatment option for OSA patients.

Changes of the Pharyngeal Space by Various Oral Appliances for Snoring (수종의 코골이장치 장착에 따른 인두공간의 변화)

  • Jo, Chul-Bae;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.247-256
    • /
    • 2009
  • The purpose of this study was to investigate the changes of the pharyngeal space when the following appliances were inserted: the mandibular advancement appliance (MAA), tongue retaining appliance (TRA), and mandibular advancement-tongue retaining appliance (MATRA). Nine male dental students exhibiting Class I occlusion, normal body mass index (BMI), and no signs and symptoms of snoring were selected for this study. The three kinds of snoring appliances (MAA, TRA and MATRA) were fabricated for each subject. The mandibular advancement of the MAA and MATRA was set at a distance of 5 mm, and the TRA and MATRA were made to hold the tongue in front of the maxillary incisors by 10 to 20 mm. Lateral cephalometric radiographs of the following four states - with no appliance, MAA, TRA, and MATRA - were taken to examine any anatomical changes resulting from the application of the appliances. All four radiographs were traced and analyzed for twenty selected variables related to the pharyngeal space, cranio-cervical posture, and position of the soft palate and hyoid bone. According to the results of this study, there were significant increases in both the upper and lower oropharyngeal spaces when the mandible and tongue were protruded simultaneously, although there was a significant increase only in upper oropharyngeal space when the mandible or tongue was advanced separately. In conclusion, it is suggested that the MATRA may result in more positive effect on the control of snoring and OSA compared to a single use of the MAA or TRA, especially for the patients whose upper airway obstruction occurs in the lower oropharynx.

Variables Affecting Long-Term Compliance of Oral Appliance for Snoring (코골이 치료용 구강장치의 지속적 사용에 영향을 주는 요인의 분석)

  • Lee, Jun-Youp;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.305-316
    • /
    • 2008
  • The mandibular advancement device(MAD) has been used to help manage snoring and obstructive sleep apnea. The aims of this study were to specify the demographic and clinical characteristics of the patients receiving long-term treatment with MAD and to quantify the compliance with and side effects of the use of the device. Of 103 patients who were treated with MAD for at least one full year after delivery date, 49 were able to be contacted with telephone and complete follow-up questionnaires were obtainable. They were telephoned to determine whether they were still using the device. If not, they were asked when and why they stopped using it. Patients were also asked how much effectiveness of the MAD in decreasing snoring and how much they and their bed-partners were satisfied with the MAD therapy. The initial respiratory disturbance indices and pre-treatment snoring frequency and intensity were obtained from the medical records of initial visit. All the data were compared between users and nonusers. The results were as follows: 1. Of 49 patients 25 are still using the device, but 24 stopped using it. Among nonusers nobody stopped wearing the device within first 1 month, but 37.5% of nonusers stopped wearing it in the following 6 months, and another 4.2% before the end of the first year. 2. The one-year compliance of the MAD therapy was 79.59%. 3. There were no significant differences in mean age, mean body mass index, and gender distribution between users group and nonusers group. 4. There was no significant difference in mean respiratory disturbance index at initial visit between users group and nonusers group. 5. There was no significant difference in pre-treatment snoring frequency and intensity between users group and nonusers group. 6. The degree of decrease in snoring with use of MAD was significantly higher in the users when compared to nonusers. 7. Patient's overall satisfaction with treatment outcome was significantly higher in the users when compared to nonusers. 8. Bed partner's satisfaction with treatment outcome tended to be higher in the users when compared to nonusers. 9. The most frequent reasons why patients discontinued wearing the MAD were: jaw pain(25%), dental pain(20.83%), broken appliance(20.83%), hassle using(16.67%), lost weight(8.3%), dental work(8.3%), no or little effect(4.17%), sleep disturbance(4.27).

The effects of maxillary protraction appliance (MPA) depending on vertical facial patterns (수직적 안모 형태에 따른 상악골 전방 견인 장치의 효과 비교)

  • Ryu, Young-Kyu;Lee, Kee-Joon;Oh, Chang-Hun
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.413-424
    • /
    • 2002
  • Preadolescent children with deficient maxillae are suitable candidates for the maxillary protraction appliance(MPA). The theoretical effect of the MPA is protraction or anterior displacement of the maxilla. However, it is known that complex effects such as anterior displacement of the maxillary teeth, downward and backward rotation of the mandible, linguoversion of the mandibular anterior incisors, are known to play a role in improving the Cl III malocclusion. There have been much studies with regard to maxillary protraction, but the different effects of MPAs depending on the vertical facial pattern are not known precisely. This study was based on 67 patients (31 males, 36 females) aged from 6 years 6 months to 13 years 3months, who visited the Dept. of Orthodontics at Yonsei Univ., Dental Hospital and diagnosed as skeletal Class III with maxillary deficiency. They were divided into 3 groups (low, average, high angle groups) depending on genial angle and the SNMP (Go-Gn) angle, respectively. Pretreatment and post-treatment lateral cephalograms were used to compare the effects of MPA and the following conclusions were obtained: 1) A significantly large amount of backward movement of the B point was observed in patients with a low SNMP angle. Those with a high SNMP angle had significant forward movement at A point. 2) The patients with low genial angle had the least forward movement at the A point, and those with a high angle had more forward movement. 3) In comparing the arcTan of the A point, the high angle group showed more horizontal movement while the low angle group showed more vertical movement. 4) There was no significance between the treatment duration of the SNMP and the Genial angle groups.

MAXILLARY MOLAR DISTALIZATION WITH A PENDULUM APPLIANCE (Pendulum 장치를 이용한 상악 대구치의 원심이동 증례)

  • Lee, H.J.;Kim, Y.J.;Kim, J.W.;Jang, K.T.;Lee, S.H.;Kim, C.C.;Hahn, S.H.
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.523-531
    • /
    • 2008
  • Maxillary molar distalization is a treatment approach for patients with Class II malocclusions who do not require extractions and mesial movements of mandibular molars. The pendulum appliance is effective for distalization of the maxillary molars and independent of patient cooperation. This appliance can stabilize the maxillary premolars and use the palatal rugae area as an additional anchorage. However, caution is needed to control collateral effects, including increase of lower facial height, incisor protrusion and damage to the rugae area. This article reports the cases in which maxillary molar distalization achieved by pendulum appliance resolves the space problems and corrects the molar relationships.

  • PDF

Antisnoring Effects of Adjustable Anterior Positioner: Case Study (조절성 전방이동형 코골이 방지장치의 효과)

  • Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.213-219
    • /
    • 2012
  • Oral appliances are a primary treatment option for snoring and mild to moderate obstructive sleep apnea (OSA) and are considered as an alternative for patients with severe OSA who have failed continuous positive airway pressure (CPAP) or upper airway surgery. But it is true that OAs have varying degrees of effectiveness depending on different oral appliances and the efficacy of OAs are established in some but not all patients. New oral appliance, which is one of Adjustable Anterior Positioners, was developed by Dept of Oral Medicine, Dental School, Dankook University. This is a report for treating severe OSA patient with a failure of previous uvulopalatopharyngoplasty using a new Adjustable Anterior Positioner, followed by significant success of controlling OSA.