• Title/Summary/Keyword: 하수 재이용

Search Result 287, Processing Time 0.028 seconds

Evaluating the Performance of Blended Fertilizer Draw Solution in Reuse of Sewage Water Using Forward Osmosis (정삼투를 이용한 하수의 재이용에서 혼합비료 유도용액의 성능 평가)

  • Kim, Seung-Geon;Lee, Ho-Won
    • Applied Chemistry for Engineering
    • /
    • v.31 no.1
    • /
    • pp.90-96
    • /
    • 2020
  • This paper aims to reuse sewage by a forward osmosis using a blended fertilizer as a draw solution. This work deals with the primary sedimentation basin influent, effluent, and secondary sedimentation basin effluent from J sewage treatment plant. The average permeate water flux was higher in the order of the blend of KCl and NH4Cl > KCl and NH4H2PO4 > KCl and (NH4)2HPO4, and the reverse solute flux was lower in the order of the blend of KCl and NH4H2PO4 < KCl and NH4Cl < KCl and (NH4)2HPO4. Regardless of the blended fertilizer, the permeate water flux of the effluent from the secondary sedimentation basin was the highest. The blended fertilizer of KCl and NH4H2PO4 was found to be most useful for the reuse of sewage because it contains nitrogen, phosphorus and potassium, which are the major components of a fertilizer, and has a low reverse solute flux. When the blend of KCl and NH4H2PO4 was used as a draw solution, the average permeate water and reverse solute flux for the secondary sedimentation basin effluent were 12.14 L/㎡hr and 0.012 mol/㎡s, respectively.

하수도 업무지원을 위한 하수도 관망해석 컴포넌트 설계에 관한 연구

  • Kim, Kye-Hyun;Lee, Woo-Chul;Kim, Jun-Chul
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 2000.06a
    • /
    • pp.181-186
    • /
    • 2000
  • 국가지리정보체계사업을 시작으로 여러 응용분야에서 지리정보시스템을 구축하고 있으며, 특히 지자체에서는 도시정보화 차원에서 UIS(Urban Information System;도시정보시스템)를 구축하고 있다. 지자체의 업무들은 지자체의 상황에 따라 조금씩 차이를 보이지만 업무 단위로 따져 볼 때 공통적으로 수행되는 업무들이 많으며, 지리정보 관련 업무 또한 예외가 아니다. 지금까지 각 지자체의 도시정보시스템은 공통업무에 대하여 중복개발이 불가피 하였으며, 재사용성을 기대하기 어려웠다. 이런 비효율을 극복하는 방안으로 컴포넌트 기술이 대두되었으며, 컴포넌트 기술을 이용하여 업무변화에 유연하고 재활용을 극대화할 수 있는 업무 컴포넌트 개발이 필요한 시점이다. 본 논문은 지자체의 지리정보 관련 업무의 하나인 하수도 업무 중 하수배출용량 산정을 위한 하수도 관망해석 컴포넌트 설계를 제시하였다. 하수도 관망해석 컴포넌트는 하수배출용량을 산정하고, 하수 배출용량을 토대로 통수능이 부족한 하수관거를 추출하며, 통수능 부족 관거에 대하여 적정한 교체 관경 결정을 지원할 수 있도록 설계하였다 컴포넌트 설계과정은 표준업무를 지원할 수 있도록 업무분석을 수행하였으며, 이의 결과물로 하수도 관망해석 알고리즘을 도출하였으며, 알고리즘을 기반으로 하수도 관망해석 업무를 수행하는 하수도 관망해석 컴포넌트를 설계하고 설계 내용을 UML(Unified Modeling Language)로써 명세화 하였다. 현재 설계에 따라 하수도 관망해석 컴포넌트가 개발되고 있으며, 개발된 컴포넌트를 이용한 하수도 관망해석 시스템을 구축할 예정이다. 추후에는 하수도 관망해석 컴포넌트와 하수도 업무 컴포넌트와의 통합부분에 대한 연구가 진행되어야 할 것이다.7.0로 하고 표준(標準) EDTA 용액(溶液)을 소량(少量)넣고 8N-KOH로 pH $12{\sim}13$으로 하고 N-N 희석분말(稀釋粉末)을 지시약(指示藥) 으로써 표준(標準) EDTA 용액(溶液)으로 적정(滴定)하여 Ca 치(値)를 얻었다. Ca와 Mg의 합계결정치(合計決定値)와 Ca 적정치(滴定値) 차(差)로 Mg 치(値)를 얻었다. 음(陰) ion 구분(區分)으로부터 상법(常法)에 의하여 $MgNH_4PO_4$의 침전(沈澱)을 만들어서 HCl에 녹키고 일정량(一定量)의 표준(標準) EDTA 용액(溶液)을 넣어 pH 7.0로 한다음 완충액(緩衝液)으로 pH 10으로 하고 BT 지시약(指示藥)을 써서 표준(標準) Mg $SO_4$용액(溶液)으로 적정(滴定)하여 P 치(値)를 얻었다. 본법(本法)으로 Na-phytate를 분석(分析)한 결과(結果) Na-phytate의 분자식(分子式)을 $C_6H_6O_{24}P_6Mg_4CaNa_2{\cdot}5H_2O$라고 하였을 때의 이론치(理論値)에 비(比)하여 P가 98.9% Cark 97.1%, Mg가 99.1%이고 통계처리(統計處理)한 결과분석치(結果分析値)와 이론치(理論値)는 잘 일치(一致)된다. 그러나 종래법(從來法)에 의(依)한 분석치(分析値)는 이론치(理論値)에 비(比)하여 P가 92.40%, Cark 86.80%, Mg가 93.80%로서 이론치(理論値)와 일치(一致)하지 않는다. 3) Na-phytate를 전분(澱粉)과 일정(一定)한 비(比)로 혼합(混合)하고 본법(本法)으로 P,Ca 및 Mc를 정량(定量)한 결과(結果) 이들의 회수율(回收率)은 거의 100%이었다. 4) 본분석법

  • PDF

Advanced Treatment Efficiency of Biological String Media and Oenanthe javanica for Effluent Quality Improvement in the Sedimentation Model Plant (하수의 최종 유출수 수질 개선을 위한 침전조 모형실험에 적용한 끈상 미생물접촉재와 미나리의 고도처리효율에 관한 연구)

  • Bae Joon-Sam;Lee Sang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.440-447
    • /
    • 2006
  • This study was aimed at the improvement of the effluent quality of municipal wastewater treatment plant by Oenanthe javanica and Bio-string media. The results were compared with conventional sedimentation tank and pilot sedimentation plant. In this study BOD as organic pollutants, SS, Nitrogen and Phosphorus were tested to evaluate the removal efficiencies for the advanced treatment. The result were as follow: in the Pilot Plant experiment, Tank 2 was fairly high removal efficiency as compared with Tank 1. The removal efficiency of BOD and SS in Tank 2 were as a range of $7.9%{\sim}38.8%,\;14.3%{\sim}60.0%$ and the removal efficiency of T-N, T-P were a range of $9.6%{\sim}31.5%,\;33.0%{\sim}80.0%$ respectively. The removal efficiency of T-P and SS were much higher than BOB and T-N.

  • PDF

The Effects of Substitution Rate of Incinerated Sewage Sludge Ash on the Concrete Materials (건설재료로서 하수슬러지 소각재 적정 대체율 도출에 관한 연구)

  • Kim, Chun ho;Kim, Nam wook
    • Resources Recycling
    • /
    • v.25 no.1
    • /
    • pp.10-15
    • /
    • 2016
  • In recent years, in terms of environmental protection and efficient use of the land, efficient utilization of byproducts and wastes generated in industrial areas are emerging. In this study, for the effective utilization of using ever increasing amount of utilizing sewage sludge incineration ash to increase sewage sludge, it is evaluated the use of as an construction material. After making concrete specimens, it is evaluated compressive strength, carbonation and environmental resistance. From the experimental results, compared with concrete without sewage sludge it is obtained satisfactory results for compressive strength and carbonation and results of the leaching test also satisfies the standard value. So, it is sufficient possibility using of concrete aggregate and the replacement rates is judged to be about 10%.

Application of Coagulation-UF Hybrid Membrane Process for Reuse of Secondary Effluent (하수 2차 처리수 재이용을 위한 hybrid 응집-UF 막분리 공정의 적용)

  • Lee, Chul-Woo;Shon, Jung-Ki;Shon, In-Shik;Han, Seung-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.605-612
    • /
    • 2005
  • The objective of this study was to evaluate the factors affecting the optimization of coagulation hybrid UF membrane processes for the reuse of secondary effluent from sewage treatment plant. The experimental results obtained from the UF membrane process showed that organic colloids in the size range of $0.2{\mu}m{\sim}1.0{\mu}m$ caused the most substantial influence on the fouling of UF membrane. When using a coagulation pretreatment to UF membrane, alum dosage of 50mg/L resulted in the least reduction in membrane permeate flux. Also, for the rapid mixing process, in-line mixer type was more efficient for organic removal than back mixer type. Therefore, it may be concluded that coagulation-UF hybrid membrane process comparing to UF alone process showed not only higher removal efficiency of organic matter, but also substantial improvement of permeate flux of UF membrane.

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

Application of MBR process for the treatment of RO concentrate from wastewater reuse process (하수재이용 공정에서 발생되는 RO농축수 처리를 위한 MBR 공정 적용)

  • Lee, Do-Hun;Jang, Hyun-Ji;Kim, Han-Seung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.339-349
    • /
    • 2013
  • Biological treatment of RO concentrate from wastewater reuse process is known to be very difficult due to its high concentration of non-degradable organics and salt ions such as chloride, nitrate and phosphate. In this research, the treatment performance of MBR was examined using RO concentrate mixed with raw wastewater as the influent of MBR. Addition of PAC (powdered activated carbon) to MBR was also evaluated in order to enhance the treatment performance and stability. The performance of MBR for treating only RO concentrate decreased gradually although external carbon source was added. The average removal performance of MBR with and without PAC decreased from 99.1 %(98.8 %) to 94.9 %(91.4 %) for COD, 81.3 %(80.3 %) to 42.0 %(41.9 %) for T-N and 57.3(55.0 %) to 30.0 %(21.0 %) for T-P with the increase of RO concentrate mixing rate of 0 % to 20 % in the feed water. Addition of PAC showed positive effect on the performance of MBR for the removal of COD and phosphorus in case that the ratio of RO concentrate to feed water increased.

Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse (처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성)

  • Han, Dong-U
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.213-220
    • /
    • 2002
  • This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.

Preparation of Multi-functional Brick Using MSWI Fly Ash (소각재를 이용한 건축외장재 제조)

  • Ban, Hyo-Jin;Park, Eun-Zoo;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.114-118
    • /
    • 2009
  • With the advance of industrialization and urbanization, a lot of waste has been discharged and treated by incineration. But fly and bottom ashes are generated in this process. In addition, the treatment method to recycle sewage sludge and melting slag is required to manage these wastes. The objective of this research was to prepare of multi-functional brick which were made from MSWI (Municipal solid wastes incinerator) fly ash, sewage sludge and slag. The bricks were made by mixing raw materials and then drying for 24 hours. Next, they were dried for 24 hours at $160^{\circ}C$ and fired for 2 hours. Calcination temperature was changed to discuss the effect of temperature from $1,080^{\circ}C$ to $1,130^{\circ}C$. Compressive strength of a brick was creased with the increase of temperature. To increase mixing ratio of fly ash and slag reduce the compressive strength the optimal condition was the mixing ratio of fly ash : melting slag : sewage sludge : clay as 10 : 20 : 5 : 65 and $1,150^{\circ}C$ of calcination temperature. Compressive strength was obtained as about 41 MPa at this condition.

Effect of Solidified/Stabilized Sewage Sludge using Neutral Solidifying Chemical Agent and Alkaline Agent as Landfill Cover on Decomposition of Organic Matter in Lysimeter (중성계 및 알칼리성 고화재를 이용한 고화하수슬러지의 복토재가 모형매립조 내 유기물 분해에 미치는 영향)

  • Kim, Hye-Jin;Park, Jin-Kyu;Song, Sang-Hoon;Lee, Nam-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.8
    • /
    • pp.768-774
    • /
    • 2008
  • To evaluate the effect of the solidified/stabilized sewage sludge on landfill sites, lysimeter tests were conducted. Lysimeters (LR1, LR2, and LR3) were filled with the material(Compost : Fodder : Sand = 10 : 10 : 80) and covered with different types of the cover soils, the G solidified sludge produced from the neutral solidifying chemical agent(LR1), the A solidified sludge produced from the alkali solidifying chemical agent(LR2), and the weathered granite soil(LR3). Those lysimeters were kept at the temperature controlled room with 30 $\pm$ 2$^{\circ}C$ for about 450 days. As the results, it was appeared LR2 > LR1 > LR3 that total gas production rate(L), gas production rate(L/VS(kg)) and cumulative gas(CO$_2$ + CH$_4$) production. There were not significant differences at decrease of the COD$_{Cr}$ in the leachate from LR1 and LR3. Thus, it had been shown that the use of the G solidified sludge as cover soil did not affect the COD$_{Cr}$ in the leachate. The COD$_{Cr}$ from LR2 had been increased since around 250 days because solidified/stabilized sewage sludge became re-slurry. T-N and T-P from LR3 also were higher than LR1 and LR2. Also were, the use of the solidified/stabilized sewage sludge as a cover soil, therefore, did not affect the T-N and T-Pconcentrations in the leachate.