Feasibility Study of Wetland-pond Systems for Water Quality Improvement and Agricultural Reuse (습지-연못 연계시스템에 의한 수질개선과 농업적 재이용 타당성 분석)

  • Jang, Jae-Ho;Jung, Kwang-Wook;Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.37 no.3 s.108
    • /
    • pp.344-354
    • /
    • 2004
  • A pilot study was performed from September 2000 to April 2004 to examine the feasibility of the wetland-pond system for the agricultural reuse of reclaimed water. The wetland system was a subsurface flow type, with a hydraulic residence time of 3.5 days, and the subsequent pond was 8 $m^3$ in volume (2 m ${\times}$ 2 m ${\times}$ 2 m) and operated with intermittent-discharge and continuous flow types. The wetland system was effective in treating the sewage; median removal efficiencies of $BOD_5$ and TSS were above 70.0%, with mean effluent concentrations of 27.1 and 16.8 mg $L^{-1}$, respectively, for these constituents. However, they did often exceed the effluent water quality standards of 20 mg $L^{-1}$. Removal of T-N and T-P was relatively less effective and mean effluent concentrations were approximately 103.2 and 7.2 mg $L^{-1}$, respectively. The wetland system demonstrated high removal rate (92 ${\sim}$ 90%) of microorganisms, but effluent concentrations were in the range of 300 ${\sim}$ 16,000 MPN 100 $mL^{-1}$ which is still high for agricultural reuse. The subsequent pond system provided further treatment of the wetland effluent, and especially additional microorganisms removal in addition to wetland-pond system could reduce the mean concentration to 1,000 MPN 100 $mL^{-1}$ from about $10^5$ MPN 100 $mL^{-1}$ of wetland influent. Other parameters in the pond system showed seasonal variation, and the upper layer of the pond water column became remarkably clear immediately after ice melt. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the subsequent pond was effective for further polishing. This study concerned agricultural reuse of reclaimed water using natural systems. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, wetland- pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water in rural area.

Development and Application of Modified SWMM to Simulate Permeable Pavement and Infiltration Trench (투수성 포장과 침투 트렌치를 고려한 수정 SWMM의 개발 및 적용)

  • Lee, Jung-Min;Lee, Sang-Ho;Park, Jae-Hyeon;Lee, Kil-Seong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.326-330
    • /
    • 2007
  • 도시화 면적이 증가하면 불투수 면적이 증가하고 그에 따라 도시 하천의 평상시 유출이 감소한다. 도시유역의 평상시 수량을 회복시키는 방법으로는 침투 증진시설(투수성 포장, 침투 트렌치, 침투 측구 등)의 설치, 하수의 고도처리 후 방류 저수지에 의한 유황 개선, 지하철 용출수 활용 등이 있다. 우리나라의 경우에 일부 도시하천의 수량 감소가 심각한 상황에 이르고 있으며 이를 해결하고자 하는 노력이 최근에 나타나고 있다. 수량을 회복하려면 유량 평가를 위한 현장조사, 수량회복 계획, 재원의 반영, 수량회복 시설의 설치 및 관리의 순서로 단계별 사업이 수행되어야 한다. 계획 단계의 과업에서 필요한 사항은 여러 가지 수량 회복 방법의 영향을 정량 평가하는 것이다. 이에 핵심이 되는 것은 수량 회복 요소를 포함하거나 추가한 수문순환 평가 도구이다. 침투시설 중 투수성 포장과 침투 트렌치를 모의하도록 기존의 SWMM 모형을 수정하였다. 그 과정에서 증발량 처리와 지하수 출력기능에 대한 오류도 수정되었다. 수정 개발된 SWMM을 침투시설 모형실험 결과와 비교하여 수정된 프로그램의 적합성을 검증하였다. 투수성 포장과 침투 트렌치를 고려하여 수정된 프로그램을 안양천의 지류인 학의천 유역에 적용하여 침투시설의 효과를 분석하였다. 만일 학의천 불투수 면적의 10%를 투수성 포장으로 교체하면 하류 비산교 지점의 저수량$(Q_{275})$이 3 %, 갈수량$(Q_{355})$이 17 % 증가하는 것으로 분석되었다. 침투 트렌치의 경우 학의천 소유역 별로 100m 트렌치를 $5{\sim}10$개 시공할 경우 저수량은 약 1 %, 갈수량은 약9 %가 증가하였다. 수정 개발된 SWMM을 사용하면 침투 트렌치와 투수성 포장 이 도시 유역의 건기 수량회복에 미치는 영향을 분석할 수 있다.해 경보발령 이전에 한계수위를 넘어서는 경우(case_3)로서 분석되었다. 이러한 실패한 경보발령의 경우에 대한 원인분석 결과, 기존의 모형화를 통해 고려되지 못하였던 해안도시 홍수의 특성 중 총강우량에 대한 고려, 선행강우 여부 및 강우 지속시간, 지속시간 내 강우집중도 그리고 선정지점 내 조위의 영향과 유역내 합류식 하수관거 시스템의 영향 등 자연유역과는 다른 다소 복잡한 요소를 고려한 해안도시홍수 경보발령 기준에 대한 개선이 필요함을 확인할 수 있었다.이 좋다고 고찰된다. 6. 우리 나라의 현행 수도작기로 본 기온 및 일조조건은 수도의 분얼전기에 대해서는 호조건하에 놓여 있으나, 분얼후기인 7월 중ㆍ하순 경의 일조부족과 고온다습조건은 병해, 특히 도열병의 유발원인이 되고 있다. 7. 우리 나라의 현행수도작기로 본 전국각지의 수도의 출수기는 모두 일조시간이 적은 부적당한 시기에 처해 있다. 8. 출수후 40일간의 평균기온에 의한 적산온도 88$0^{\circ}C$의 출현기일은 수원에서 8월 23일이었고, 년간편차를 고려한 안전출수기일은 8월 19일로서 적산온도면에서는 관행 출수기일은 약간 늦다고 보았다. 9. 등열기의 평균기온에 의한 적산온도는 현행 수도작기로서는 최종한계시기에 놓여 있으며, 평균기온의 년간편차와 우리 나라의 최저기온이 낮은 점을 고려할 때, 현행출수기는 다소 늦은 것으로 보았다. 10. 생육단계별의 수도체내의 질소함량은 영양생장기의 질소함량이 과다하였으며, 출수 이후에 영양조락을 여하히 방지하느냐가 문제된다고 보았다. 11. 수리불안전답 및 천수답이 차지하는 전답면적의 비율은 차차 감소되고 있는데, 이와 전체 10a당 수량의 증가율과의 상관계수를 산출하였는데, 수리불안전답과의 상관계수 (4)는 +0.525였으며, 천수답과는 r=+0.832, 그리고 수리불안전답과 천수답을 합계한 것과의

  • PDF

Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant (바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구)

  • Shin, Jae-Suk;Kim, Sung-Chul;Cho, Kwang-Ju;Choi, Choong-Ho;Choi, In-Wook;Park, Jeong-Ja;Park, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.115-121
    • /
    • 2009
  • The hybrid constructed wetland(HCW) as tertiary treatment process of a bio industrial wastewater treatment plant was employed to estimate applications for the reuse of final effluent. Raw wastewater was sequently treated through chemical and biological treatment processes and the biologically treated water was flowed into the HCW. The HCW system was composed of two constructed wetlands connected in series; The one is the aerobic constructed wetland with natural air draft system whose driving force for air supply was the difference between the temperature of the air inside the wetland and the ambient air, and the other is the anaerobic/anoxic constructed wetland. Average influent concentrations of BOD, SS, T-N and T-P in the HCW were 53mg/L, 48mg/L, 34mg/L and 3mg/L, respectively. After being treated at HCW, final effluent concentrations of BOD, SS, T-N and T-P were 2.3mg/L, 1.2mg/L, 7.95mg/L and 0.83mg/L, respectively. Referring to a reuse standard for a sewage wastewater, final effluent could sufficiently be reuse as landscaping, washing or agriculture water. HCW system with the aerobic/anaerobic combined constructed wetland could be achieved a high removal efficiency because each constructed wetland was functionalized to be removed efficiently organics, nitrogen and phosphorus. HCW system could be estimated to be successful application as tertiary treatment process of a various industrial and municipal wastewater.

  • PDF

Efficient Spent Sulfidic Caustic wastewater treatment using Adsorption Photocatalysis System (흡착광산화 시스템을 이용한 효과적인 SSC 페수처리)

  • Kim, Jong Kyu;Lee, Min Hee;Jung, Yong Wook;Joo, Jin Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.520-520
    • /
    • 2016
  • 석유 화학공장에서 발생하는 spent sulfidic caustic (SSC) 폐수는 액화석유가스(LPG)나 천연가스(NG)의 정제과정에서 발생되는 것으로 고농도의 sulfide와 cresylic, phenolic 그리고 mercaptan 등이 포함된 독성과 냄새를 유발하는 물질이다. 이러한 물질들은 LPG나 NG의 정제과정에서 높은 산도를 가진 휘발성 황화합 물질들을 제거하기 위해 사용된 NaOH가 $H_2S$와 반응하여 발생하는 것이다. 진한 갈색 또는 검은색을 띄는 SSC 폐수는 12 이상의 높은 pH를 가지고 있으며 5~12 wt%의 높은 염분도를 가지고 있다. 또한 강한 부식성과 독성을 가진 황화합물의 농도가 1~4 wt%이며, 방향족 탄화수소 물질 (i.e. methanethiol, benzene, tolune and phenol)들도 다량 함유되어 있다. 따라서 이러한 유해 물질들은 기존의 하수처리 공정으로 방류하기 전에 완벽하게 처리해야만 하수처리 공정의 오염 부하량을 줄일 수 있다. 습식산화공정은 SSC 폐수를 처리하기 위해 흔히 사용되고 있는 물리-화학적 처리 공정이지만 고비용, 고에너지가 필요하며, 고온 및 고압에서만 작동되어 안전상의 문제점을 갖고 있다. 또한 습식산화공정을 거친 폐수는 배출허용기준을 만족하기 위해 생물학적 2차 처리가 반드시 필요하다. 철-과산화수소를 이용하는 펜톤산화 공정, 그리고 sulfide를 sulfate로 전환시키는 생물학적 처리 공정은 황화합물의 완전한 무기물화가 힘들며, 현장 적용 시 기술적 경제적 부담이 크다. 이러한 단점을 극복하고, SSC 폐수를 효과적으로 처리하기 위해 본 연구는, 높은 흡착력과 광산화력을 가진 흡착광산화 반응 시스템(Adsorption Photocatalysis System, APS)을 개발하였다. APS는 SSC 폐수를 시스템 내부로 유입하여 수중의 오염물질을 흡착광산화제로 구성된 반응구조체가 흡착하고, 흡착된 오염물질을 UV에너지와 이산화티타늄 광촉매의 광화학반응에 의해 최종적으로 무해한 물질로 환원시키는 폐수처리시스템이다. APS의 반응구조체는 태양에너지 및 인공에너지원에 의해 활용 가능하며, 난분해성 유기화합물질을 물과 이산화탄소로 분해할 수 있는 친환경적이고 경제적인 소재로서 널리 쓰이고 있는 이산화티타늄 광촉매와 화력발전소의 높은 소성온도에 의해 연소된 후 발생되는 bottom ash를 이산화티타늄의 지지체로 사용하여 높은 흡착력과 광촉매 산화력을 가진 복합물이다. 개발된 APS에 의해 SSC 폐수를 처리한 결과, COD 86.1%, 탁도 98.4%, sulfide 99.9%의 높은 처리효율을 보여주고 있다. 따라서 본 연구를 통해 개발된 APS는 강한 부식성과 독성 그리고 높은 농도를 가지고 있는 SSC 폐수를 효과적으로 처리할 수 있다.

  • PDF

A Study on Removal of T-N by Loess Ball Using Synthetic Wastewater (Loess ball에 의한 총질소 제거에 관한 연구)

  • Shin Sung-Euy;Lee Choon-Boem;Cha Wol-Suk
    • Journal of Life Science
    • /
    • v.15 no.4 s.71
    • /
    • pp.590-594
    • /
    • 2005
  • In this study, the wastewater treatment was conducted to evaluate the removal efficiency of total nitrogen from synthetic wastewater in the F-STEP PROCESS $(anaerobic{\rightarrow}\;oxic\;{\rightarrow}\;anoxic)$ with loess ball as support metrics. The average removal efficiencies of total nitrogen and ammonia nitrogen were $83.0\%\;and\;84.4\%$, respectively. The average nitrification efficiency at the oxic area was $60.9\%$ in the pH range of effluent water between 4.8 and 6.0. On the other hand, in the case of pH range of effluent water between 6.5 and 7.5, the denitrification efficiency at the anoxic area was $96.3\%$. The average concentration of COD was 12.8 ppm and the removal efficiency of COD in the F-STEP PROCESS were $96.3\%$. In the case of SS, the average concentration was $7.0\%$ at the effluent.

Analysis of Flood Reduction in Downstream Urban Areas for the Storage in Apartment Complex (하류 도심지 침수저감 분석을 통한 공동주택 단지의 우수저류조 계획)

  • Jae-Do Choi;Hyoung-Chul Lim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.698-709
    • /
    • 2023
  • Purpose: In this paper, we would like to analyze the growth rate of existing urban immersion in the downstream during large-scale urban development and the degree of reduction in existing urban immersion in the downstream when small excellent storage facilities are planned in apartment complexes. Method: A large-scale sewage model was built using the SWMM model of the U.S. Environmental Protection Agency, and the impact of flooding in existing downtown areas downstream was analyzed through simulation. The built model included the development zone, the existing downtown area downstream, and the entire river basin that discharges rainwater. Result: As a result of calculating and simulating the minimum excellent reservoir capacity for each apartment block in the study target area, it was found that the immersion of 4,893㎥ based on one hour, 25,815㎥ based on two hours, and 55,528㎥ based on three hours in the downstream urban area. Conclusion: As in this study, large-scale flooding simulation considering the existing downtown area in the downstream shows a significant increase in flooding in the downstream, and if excellent reservoir capacity is planned for each apartment block before development and the construction of excellent reservoirs is recommended.

A Study on Reuse of Reclaimed Water in Jeonbuk Province (전북지역 하수처리수 재이용 방안 연구)

  • Cho, Changwoo;Kim, Jintae;Park, Jeongjae;Song, Juhoon;Lee, Miseon;Jeong, Juri;Ryou, Jaewoong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.5
    • /
    • pp.237-245
    • /
    • 2017
  • This study was aimed at investigating effluent water quality and proposing reuse possibilities for 12 sewage treatment plants discharged more than $5,000m^3/day$ in order to recycle the sewage treatment plant effluent of Jeollabuk-do effectively. Additionally, a laboratory scale test for reprocessing water discharge was performed. Categories of reclaimed sewage water reuse were divided into 7 topics and analyzed a total of 28 items including 16 heavy metals based on water quality standard. As a results, color, BOD, TN, chloride and Electrical Conductivity (EC) exceeded reused water quality standard. In particular, color and TN exceeded in 8 and 5 sewage treatment plants, respectively. The value of chloride and EC were high in sewage treatment plants including the food and industrial wastewater. At 4 sewage treatment plants were possible to reuse without re-treatment. The laboratory scale test was conducted to SandFilter (SF)-Granular Activated Carbon (GAC)-MicroFiltraion (MF)-Reverse Osmosis (RO). Both the removal efficiencies and economic feasibility of total E. coli., color and Suspended Solid (SS) suited in case using the SF-GAC treatment method. The removal of chloride and EC had little effect in the case of SF-GAC-MF system, but RO showed over 90% of removal efficiency. After using SF-GAC process only, the concentration of $UV_{254}$ decreased sharply from 0.3651 /cm to 0.0306 /cm and it showed over 92% of removal efficiency rate. In conclusion, for the effective reuse of sewage discharged water, water quality and the surrounding terrain of treatment plants should be all taken into account. If it needed for the reprocessing, both the selection for treatment and economic combination treatment methods will have to be considered.

Biological Water Quality Assessments in Wastewater-impacted and Non-impacted Streams (폐수처리 시설의 영향에 따른 영산강 수계의 생물학적 수질 평가)

  • An, Kwang-Guk;Kim, Kang-Il;Kim, Ja-Hyun
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.1
    • /
    • pp.82-92
    • /
    • 2007
  • In 2003, we evaluated biological water quality at twelve sites of Youngsan River using community analysis, fish compositions, and the Index of Biological Integrity (IBI). Of the twelve, four sites were the controls, which have no point sources in the upstream and the remaining eight sites were the impacted sites, which are influenced by wastewater treatment plant (WTP) and agro-industrial complex. Model values of the IBI, based on 12 sites data, averaged 28 (n=12, range: $18{\sim}44$), indicating fair poor condition according to the criteria of US EP A (1993). In the mean time, mean IBI in the control sites (S3, S5, S6, S11) was 42 (n=4, range: $38{\sim}44$), indicating a good condition, whereas mean IBI in the impacted sites was 21, indicating a poor condition. Mean IBI value in the control, thus, was greater by 2 fold than that in the WTP sites. The spatial pattern of IBI values was similar to the patterns of species diversity index and species richness index, except for Site 11, which was 1st order stream. Similarity analysis indicated that three groups were divided at the similarity level of 80%. One group was the streams influenced by wastewater and the other two groups were the pristine streams as the control, indicating that the stream health conditions are directly influenced by presence or absence of the point sources. Also, Pearson's correlation analysis showed that IBI values had negative correlation (r=0.899, p<0.001) with relative abundance of tolerance species, and had positive relation (r=0.890, p<0.001) with sensitive species. Overall, outcomes suggest that the point sources of the WTP might impact the species composition and ecological health, resulting in degradation of biological water quality.

Analysis study on substances subject to management using long-term water quality monitoring data in tributaries of the Nakdong River basin (낙동강유역 지류에서의 장기 수질모니터링 자료를 이용한 관리 대상물질 분석 연구)

  • Byungseok Kal;Jaebeom Park;Seongmin Kim;Sangmin Shin;Soonja Jang;Minjae Jeon;Donghyun Lee
    • Journal of Wetlands Research
    • /
    • v.25 no.4
    • /
    • pp.326-334
    • /
    • 2023
  • The purpose of this study is to use long-term water quality monitoring data from tributaries of the Nakdong River system to identify problematic substances in tributaries by examining the rate of exceedance and increase in water quality targets. In the Nakdong River system, monitoring is conducted once a month for 38 tributaries that require intensive management, and this data was used to analyze trends in exceeding and increasing target water quality at each point. The analysis items are eight items that can be evaluated based on river water quality standards: DO, BOD, COD, TOC, SS, total phosphorus, fecal coliform, and total coliform. As a result of the analysis, the target water quality exceedance rate was more than 50%, and the items with an increasing trend were TOC, fecal coliform and total E. coli counts, and the items with an exceedance rate of less than 50% but an increasing trend were SS. TOC is believed to be caused by an increase in non-degradable substances, and the continued increase in Total Coliform will require management of Total ColiformTotal Coliform in effluent water from sewage treatment facilities in the future.

A Study on Long-term Variations of BOD and COD as Indicators of Organic Matter Pollution in the Han River (한강 본류에서 유기물 오염도 지표인 BOD와 COD에 대한 장기변동 특성)

  • Cho, Hyun-Seok;Kim, Kwang-Rae;Lim, Gyu-Chul;Bae, Kyung-Seok;Lee, Min-Hwan
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.4
    • /
    • pp.474-481
    • /
    • 2012
  • This study was performed to investigate the degree of long-term pollution at the mainstream of the Han River by comparing the concentration of BOD and COD from 1975 to 2011. The long-term annual average BOD and COD concentration at the mainstream of the Han River showed an increasing trend as it flowed downstream from Paldang Dam to Gayang. The concentration of BOD ($r^2$=0.646) and COD ($r^2$=0.260) showed a consistent decreasing trend for 37 years. In the case of Paldang Dam, BOD has maintained a decreasing trend, whereas the COD value showed an increasing trend after the 1990s. Therefore, a control of non-biodegradable materials in areas around Paldang Dam is required. The result of the seasonal variations of BOD and COD is as follows: spring>winter>summer and fall (p<0.001). The time series analysis revealed a strong correlation for every 12-month period. Also, the amount of water discharge at Paldang Dam has to be systematically controlled because the amount of water discharge from the dam influences the water quality at the mainstream of the Han River.