• Title/Summary/Keyword: 하수

Search Result 3,833, Processing Time 0.04 seconds

Improvement of strength and prevention of twist strain in sewer pipe using glass fiber and twist prevention band (유리 섬유와 뒤틀림 방지 밴드를 이용한 하수관거의 강도 및 뒤틀림 개선 방안 연구)

  • Hong, Seok In;Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • Maintenance of sewer pipe process sewer pipe repairing process is necessary for deterioration of sewer pipe. In this research, analysis on performance (strength and twist strain) of eco-friendly and even expanded liner process using glass fiber and twist prevention band. As a results, tensile strength, bending strength and failure load is increased after the sewer pipe repairing process than advanced research results. And sewer pipe after the this process obtained advantage of prevention of twist strain and economic. After the this research, sewer pipe repairing process using glass fiber and twist prevention band could be suggest the eco-friendly and effective sewer pipe repairing process.

The Feasibility of Co-Incineration for Municipal Solid Waste and Sewage Sludge through the Change of Heat Loading and Atmospheric Pollutants Loading (하수슬러지와 생활폐기물 혼합소각시 열부하 변화 및 대기오염물질 부하 변화를 통한 혼합소각 가능성에 관한 연구)

  • Cho, Jae-Beom;Kim, Woo-Gu;Yeon, Kyeong-Ho;Shin, Jung-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.9
    • /
    • pp.583-589
    • /
    • 2012
  • The various promotion countermeasures such as solidification, carbonization, and the creation of cement materials have been considered to existing treatment methods such as incineration and the creation of composts, since direct landfill was prohibited for encouraging the recycling based on the sludge treatment on land. The Main objective of this study is to investigate the feasibility of co-incineration for MSW (Municipal Solid Waste) and SS (Sewage Sludge) through the change of heat and atmospheric pollutants. In this study, LHV (Low Heating Value) is 100~300 kcal/kg because the MC (Moisture Content) of de-hydrated sewage sludge is approximately 80%. From the results, we knew the feasibility of co-incineration for MSW (80%) and SS (20%). As the co-incineration rate of SS up to 20% became higher, the loading of heat and atmospheric pollutants was not influenced.

Estimation of Design Population and Design Wastewater Flow Rate for the BTO Project of Wastewater Treatment Facilities (하수종말처리시설 민간투자사업을 위한 계획 인구 및 계획 하수량 추정)

  • Son, Young-Gyu;Lee, So-Young;Kim, Lee-Hyung;Khim, Jee-Hyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.145-151
    • /
    • 2008
  • A novel method was suggested for the estimation of design population and design wastewater flow rate in fishing and agrarian village. Even though the population was decreasing continuously in this area, the design population was considered as constant with the passage of the time in conventional methods. And although the portion of groundwater uses was pretty high, the design wastewater flow rate was determined by the supply amount of tap water. Consequently, the design population and the design wastewater flow rate were overestimated. To prevent these overestimates, the design population was predicted to decrease gradually using the population trends from Korea National Statistical Office, and the design wastewater flow rate was determined using the way that the supply amount of tap water was applied in developed areas and the supply amount of groundwater was used in undeveloped areas.

Introduction of Wastewater Reuse Project in Jeju Island (제주 하수처리장 재이용사업 소개(판포))

  • Lee, Kwang-Ya;Kim, Hae-Do;Joo, Jin-Hun;Kim, Young-Jin;Kang, Su-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.469-469
    • /
    • 2012
  • 제주 지역은 대부분 지하수를 이용하고 있으며, 제주 서부지역의 경우, 지하수의 과다한 취수로 인해 지하수 하강은 물론 해수침투현상도 나타나고 있다.(제주미디어 2009.10) 제주지역의 지하수 적정 개발량은 약 97%에 이르고 있어 국지적으로는 지하수 개발이 한계에 이른 것으로 평가된다. 따라서, 농촌용수 공급을 위한 사업이 필요하며, 농업 환경 피해를 최소화할 수 있는 방안이 필요하다. 또한 농촌지역의 도시화에 따라 하수처리장의 농촌지역에도 늘어가고 있으며 이제는 농촌지역과 도시지역이 구분되지 않고 혼합되어 있는 형태로 발전하고 있기 때문에 과거의 농업활동도 변화되고 있으며, 하천에서 취수하는 용수중에서 농업용수로의 사용이 부적합한 용수가 취수되고 있다. 따라서 하수처리수의 농업용수 재이용시스템과 같이 수처리를 이용한 농업용수의 공급방안이 확대될 것으로 판단된다. 한국농어촌공사 농어촌연구원에서는 (주)필로스, (주)블루인바이로먼트엔텍과 함께 글로벌탑 환경기술개발사업의 과제를 수행하고 있으며, 본 연구를 통하여, 고내구성 고기능성의 복합막 기능이 부여된 UF/NF 분리막 소재 및 모듈을 개발하고 전기분해/오존조합에 의한 에너지 절약형 재이용수 공정기술을 개발하여, 판포하수처리장을 Test-bed로 선정하여 개발 기술을 적용하고자 한다. 제주도 한경면 판포리에 위치한 판포하수처리장은 하수재이용 사업을 통해 수처리 및 용수 공급 관로가 설치되어 있으며, 개발한 재이용수를 현지에서 공급 활용할 수 있어, 연구개발에 국한되지 않고 실증 플랜트에서 용수 사용자까지 연결이 가능하여 최적의 입지 연건을 가지고 있다. 개발될 시스템은, 유입조, ECR 반응조, AOPs, 나노버블을 이용한 막세정 시스템, UF/NF 시스템으로 공정이 설계되며, 제염처리는 물론 제주지역의 농업용수로써 안정적인 용수를 확보할 수 있는 시스템을 구축하고 있다. 본 연구개발을 통한 최종 목표는 하수처리장의 방류수 고도처리를 통해 도시, 농촌지역에 필요한 고품질 맞춤형 재이용수로 공급하고, 국내 외 하수 재이용시장으로 진출하는데 있다.

  • PDF

Improvement of the Biological Process against Advanced Water Quality Standard in Winter Season (동절기 수질기준 강화에 대비한 생물학적 공정의 개선 방안)

  • Han, Man-Shin;Choi, Gye-Woon;Lee, Jin-Young;Lee, Min-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.478-478
    • /
    • 2012
  • 국내의 하수도 보급률은 90%에 달하고 있으며, 하수의 고도처리와 처리기술이 향상된 신기술개발 등으로 수질개선 효과가 크게 개선되어 있고, 전국 각지에 활발하게 하수처리장의 건설이 추진 중에 있지만, 다양한 오염원의 증가와 함께 환경기준은 점차적으로 강화되고 있어 기존 하수처리장은 강화되고 있는 환경기준을 만족시키기 어려운 실정으로 새로운 처리법의 도입이 절실히 요구되고 있는 실정이다. 시설이 노후화된 하수종말처리장의 경우에는 경제적인 부담감을 이유로 기존 공법 개선을 통한 수질기준을 만족하기 위하여 노력하고 있으며, 특히, 방류수 수질 중에서 총질소(T-N)와 총인(T-P)의 기준을 평상시와 겨울철(12월 1일부터 3월 31일까지)로 구분하여 적용하여 왔지만, 2012년부터는 이를 동일하게 적용함으로써 겨울철 생물학적 처리 공정에서의 효율저하로 인한 기준치 만족이 어려운 상황이다. 본 연구에서는 인천의 하수처리장을 대상으로 동절기 수온의 저하에 따른 생물학적 공정을 개선시키기 위하여 운전조건을 변경하여 수질개선 증대 방안을 도출하고자 하였으며, 생물학적 공정인 MLE공법으로 동절기 외부 온도의 영향을 받는 조건을 갖는 사업소를 대상으로 실내 실험장치를 구성하여 조건을 변화하면서 개선 효과를 검토하였다. 생물반응조의 공정위치 변화, 미생물농도 그리고 체류시간변화 등의 실험조건으로 하수 처리 효율을 분석하였으며, 운전 중 외부반송 유량, 내부반송 유량 등의 운전인자는 일정하게 유지하였고, 동절기 온도인 $10^{\circ}C$로 유지하여 실험을 진행하였다. 실험 결과 대상 하수처리장의 생물학적 공정의 개선방향은 공정 배열을 변화하였을 때, 현재의 공정 배열 조건인 무산소조 1개, 호기조 4개의 공정보다 호기조 1개, 무산소조 1개, 호기조 3개로 수정하는 경우 현재 공정보다 질소는 7%, 유기물은 9.2% 처리효율이 개선되는 것으로 분석되었다. 미생물 농도 변화를 주어 수질 개선 효과를 검토한 결과 하수처리장 설계농도인 3,500ppm의 경우보다 미생물 농도를 5,970ppm으로 증가시킨 경우 17.4% 처리효율의 개선효과를 보여 질소 제거를 위해 미생물의 농도를 증가시키는 것이 바람직한 것으로 판단하였다. 또한, 체류시간(HRT)을 변화한 경우에는 현재 체류시간(HRT)인 8시간 보다 10시간으로 증가시켰을 경우 유기물은 3.2%, 질소는 2.6%의 처리효율이 개선되는 것으로 분석되었다.

  • PDF

Selection of Optimum Pebbles Size in Sewage Treatment Plant by Natural Purification Method (자연정화공법에 의한 하수처리장에서 최적 여재 선정)

  • Seo, Dong-Cheol;Cho, Ju-Sik;Park, Hyun-Geoun;Kim, Hyoung-Kab;Heo, Jong-Soo;Lee, Hong-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.22 no.1
    • /
    • pp.26-35
    • /
    • 2003
  • An investigation was carried out to evaluate the effects of pebble size on the small-scale sewage treatment apparatus by natural purification method that consisted of aerobic and anaerobic plot. pH and EC in both plots varied minimally regardless of pebble size. DO in aerobic plot increased as the pebble size decreased. That in the anaerobic plot was slightly less in comparison with that of the aerobic plot but varied minimally, $2.4{\sim}5.1\;mg/L$ regardless of pebble size. Under all experimental conditions, removals of BOD, COD and turbidity in anaerobic plot were more than 98, 91 and 98, 98% respectively. Removals of T-N and T-P increased as pebble size decreased. Under all experimental conditions, removals of T-N and T-P in anaerobic plot were about $45{\sim}59$ and $480{\sim}96%$, respectively. Judging from the above results, it should be considered that the optimum pebble size and pebble permeability in both plot was $2{\sim}4$ and $0.1{\sim}4\;mm$, respectively.

Analytical Evaluation of Influent Depending on the Occurrence of Rainfall by Case Study of Wastewater Treatment Facility (하수처리시설 사례 별 강우발생 유무에 따른 유입수 분석 평가)

  • Choi, Langkyu;Chung, Jin Do
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.3
    • /
    • pp.35-49
    • /
    • 2019
  • Currently in 2018, Korea has over 600 operating sewage disposal facilities. The law requires a sewage treatment plant to treat 500 tons or more of water per day, and a small-decentralized sewage treatment facility in a community to treat 50 tons or more to less than 500 tons of water per day. However, most facilities fulfill neither the quantity nor the quality requirements from the original design for such reasons as inflow of rainwater and ground water due to deterioration of pipelines and unauthorized input of wastewater in the pipelines. The research has selected 2 representative cases among the technical diagnosif sewage pipelines in many regions within the country to use it as the baseline of: hourly flowrate and BOD water quality analysis in both clear and rainy days, proper plant operation through inflow rate and ratio calculation, and diagnostic evaluation for deterioration of the pipelines and their accessary structures. This also suggests facilities that treats 500 tons or more of inflow per day to sample and analyze the water hourly for 24 hours once a week in both clear weather and rainy weather considering the influence of rainfall on a regular basis.

Calculation of Rainwater and Groundwater Fraction in Sewerage: A Case Study in Deokjin Park, Jeonju (동위원소를 이용한 하수 내 지하수 및 우수 함량 산출: 전주 덕진공원 유역 사례)

  • Choi, Seung-Hyun;Kim, Kangjoo;Moon, Sang-Ho
    • Economic and Environmental Geology
    • /
    • v.49 no.5
    • /
    • pp.361-370
    • /
    • 2016
  • It is well known that the inflow of rainwater and the infiltration of groundwater to sewerage (I/I) increase the sewage and burden sewage treatment plants and lower their treatment efficiency. Therefore, it is important to estimate the amount of I/I. In this study, well groundwaters, public water supplies (PWSs), and sewage and rainwater channels were investigated to check whether oxygen and deuterium isotopes could be used as a tool for I/I estimation. This study shows that the isotopic composition of PWS in Jeonju area is very consistent over time and distinctly lighter than the circulating local rainwater (CLR) because it is supplied from Yongdam Dam, which is located about 40 km inland to the east in the mountainous area. Considering the fact that sewage mostly originates from the PWS, we could calculate the amounts of CLR in the sewerage from a monitoring station using unaffected rainwater and tap water as mixing end members. The calculation revealed that the CLR fraction ranged from 50% to 90% depending on observation time. This is well supported by the dilute natures of the sewages at the station. The fraction of PWS in investigated well waters were about 46%, indicating that leaking of PWS is very serious and is an important groundwater source in the study area. Since the infiltration of such groundwater may not alter the isotopic composition of sewage significantly, the actual I/I would be much greater than the calculated ones.

Study on the influence of sewer network simplification on urban inundation modelling results (하수관망의 간소화가 도시침수 모의에 미치는 영향 분석에 관한 연구)

  • Lee, Seung-Soo;Pakdimanivong, Mary;Jung, Kwan-Sue;Kim, Yeonsu
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.4
    • /
    • pp.347-354
    • /
    • 2018
  • In urban areas, runoff flow is drained through sewer networks as well as surface areas. Therefore, it is very important to consider sewer networks as a component of hydrological drainage processes when conducting urban inundation modelling. However, most researchers who have implemented urban inundation/flood modelling, instinctively simplified the sewer networks without the appropriate criteria. In this research, a 1D-2D fully coupled urban inundation model is applied to estimate the influence of sewer network simplification on urban inundation modelling based on the dendritic network classification. The one-dimensional (1D) sewerage system analysis model, which was introduced by Lee et al. (2017), is used to simulate inlet and overflow phenomena by interacting with surface flow. Two-dimensional (2D) unstructured meshes are also applied to simulate surface flow and are combined with the 1D sewerage analysis model. Sewer network pipes are simplified based on the dendritic network classification method, namely the second and third order, and all cases of pipes are conducted as a control group. Each classified network case, including a control group, is evaluated through their application to the 27 July 2011 extreme rainfall event, which caused severe inundation damages in the Sadang area in Seoul, South Korea. All cases are compared together regarding inundation area, inflow discharge and overflow discharge. Finally, relevant criterion for the simplification method is recommended.

충남 지역 하수 슬러지의 물리$\cdot$화학적 특성에 따른 재활용 방안 연구 - 유기물을 중심으로 -

  • 이기환;이태호;박병빈;최석남
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2000.05a
    • /
    • pp.257-258
    • /
    • 2000
  • 충남 지역에서 발생되는 하수 슬러지를 대상으로 재활용을 위한 물리$\cdot$화학적 특성을 조사하였고, 이를 기초로 유기물 중심의 퇴비화 및 연료화 방안을 검토하였다. 하수 슬러지의 함수율은 약 80 % 정도 되며, 유기물이 고형물의 50 % 정도로 퇴비화를 위해서는 다른 폐기물과의 적절한 혼합이 이루어져야 할 것이며, 부숙기간에 따른 C/N비, 식물 독성 및 중금속의 거동 등과 같은 안정성의 신중한 관리가 절실히 요구된다. 또한, 하수 슬러지에 석유 코우크스를 혼합함으로서 무연탄 수준을 넘는 5,000 kcal/kg 이상의 열량을 확보하여 자체 착화가 가능할 것으로 사료된다. 그리고, 하수 슬러지의 함수율을 낮추기 위한 연구 개발이 시급하게 요구되고 있으며, 건조 공정의 연구개발이 성공적으로 이루어진다면 하수 슬러지의 중량감소에 의한 경제적인 면과 재활용방안의 다각화도 함께 이루어 질 수 있을 것으로 사료된다.

  • PDF