• Title/Summary/Keyword: 하수관로

Search Result 118, Processing Time 0.026 seconds

Development of Rapid Hardening Backfill Material for Reducing Ground Subsidence (지반함몰 저감을 위한 속경형 하수관거 뒤채움재료 개발)

  • Ryu, Yong-Sun;Han, Jin-Gyu;Chae, Woo-Ri;Koo, Ja-Sul;Lee, Dae-Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.3
    • /
    • pp.13-20
    • /
    • 2015
  • Inappropriate backfill material and poor compaction cause the damage to sewer and ground settlement. To deal with such problem, flowable backfill material has attracted attention recently. A basic study was conducted in a bid to obtain optimum mixing ratio of backfill material with the characteristics of rapid hardening, pseudo-plasticity, flowability and anti washout ability and enhance the cost efficiency of backfill material. Through the test of optimal mixing ratio of rapid hardening, evaluation of optimal mixing ratio of backfill material was conducted. As a result, required performance as well as cost efficiency could be achieved by adjusting plasticizer even in case of increasing W/M of the paste of rapid hardening to 100%.

Fixing unit and byte improvement of unit for cutting of projecting parts connects with interior part of drainpipe (하수관로 연결돌출부 절단기 유닛 고정유닛과 바이트 개선)

  • Kim, Jae-Yeol;Yoo, Sin;An, Jae-Sin;Kwak, Yi-Gu;Song, Kyung-Seok;Lee, Chang-Sun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1166-1169
    • /
    • 2003
  • The issue with the drainpipe now a day is that they are laid underground Causing us to perform additional work to repair, such as digging up the ground and peeling off the insulator that surrounds the pipe. And such series works are difficult that concession appears from government and municipal office. However, if we can save time and money. Performance of piping robot that we are studied in existing session through fixing unit and improvement of cutting byte shorten and wished to heighten work efficiency. This is why we aye trying to develop a unit that can cut up the projecting parts which connects with the interior part of the drainpipes.

  • PDF

Application Methods of Smart Water Grid to Small Municipalities in Nepal (네팔 소도시 내 스마트워터그리드의 적용 방안)

  • Jang, Dong Woo;Choi, Gye Woon;Park, Hyo Seon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.2-2
    • /
    • 2019
  • 네팔의 경우 상하수도를 비롯한 기본적인 위생시설이 크게 미비하며 수도인 카트만두조차 수십 년 된 노후관로가 상수관으로 이용되고 있다. 또한, 하수처리 시설이 사실상 전무하며, 지하수를 주요 수원으로 활용하는 대다수 지역은 식수의 오염에 따른 수인성 전염병에 취약한 실정이다. 따라서 네팔에서는 깨끗한 물과 안정적인 수도공급, 하수처리 시설의 확보가 무엇보다 중요한 과제이며, 이에 스마트워터그리드 기술의 도입을 통한 수질개선, 안정적인 수도공급방안이 요구되고 있다. 본 연구에서는 국내에서 개발된 스마트워터그리드 기술을 네팔 소도시에 적용하기 위한 방법론을 제안하였다. 네팔 소도시의 수자원 및 상수도 시설을 답사하여 문제점을 파악하고, 시설 및 운영현황을 분석하였다. 현장조사 자료를 기반으로 스마트워터그리드 기술의 적용 방향과 단기 및 중장기 계획을 제시하였다. 또한, 네팔 소도시 중 하나인 Beni시를 시범지역으로 하여 과거 30년 동안 월 강수량 기반의 가뭄지수를 분석하고, EPANET을 통하여 상수관망해석을 실시였다. 연구 결과, 가뭄의 발생횟수가 점차 빈번해지는 것으로 나타났으며, 상수관망 해석 시 대부분의 수요절점 내 수압이 설계기준보다 낮은 것으로 모의되었고, 향후 관 노후화를 고려한 절점 수압의 확보와 수질개선 방안이 제시될 필요가 있는 것으로 나타났다.

  • PDF

Performance Analysis of Detecting buried pipelines in GPR images using Faster R-CNN (Faster R-CNN을 활용한 GPR 영상에서의 지하배관 위치추적 성능분석)

  • Ko, Hyoung-Yong;Kim, Nam-gi
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.5
    • /
    • pp.21-26
    • /
    • 2019
  • Various pipes are buried in the city as needed, such as water pipes, gas pipes and hydrogen pipes. As the time passes, buried pipes becomes aged due to crack, etc. these pipes has the risk of accidents such as explosion and leakage. To prevent the risks, many pipes are repaired or replaced, but the location of the pipes can also be changed. Failure to identify the location of the altered pipe may cause an accident by touching the pipe. In this paper, we propose a method to detect buried pipes by gathering the GPR images by using GPR and Learning with Faster R-CNN. Then experiments was carried out by raw data sets and data sets augmentation applied to increase the amount of images.

Characterization of Repairing Polyurethane for Trenchless Sewer Pipeline (비굴착 하수관로용 폴리우레탄 보수재 특성 평가)

  • Park, Jun-Ha;Jeon, Sang-Ryeol;Lee, Kwan-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3542-3547
    • /
    • 2015
  • There is commonly used the full depth excavation method of sewer pipeline maintenance in Korea. This induces couple of technical and social problems like increase of construction cost and time for excavation and backfill, increase of public complains and delay of traffic, and so force. In order to overcome these problems, lots of laboratory tests were carried out for sewer pipeline of maintenance materials with trenchless methods. The testing materials are liquid and hardened polyurethane, and polyurethane CIPP. The lab tests were followed by Korean Standard. There are no side effects, like harmless to the human body and air pollution with stink. Judging from the limited test results, all the items tested were satisfied the KS criteria.

Image Processing Algorithm for Crack Detection of Sewer with low resolution (저해상도 하수관거의 균열 탐지를 위한 영상처리 알고리즘)

  • Son, Byung Jik;Jeon, Joon Ryong;Heo, Gwang Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.590-599
    • /
    • 2017
  • In South Korea, sewage pipeline exploration devices have been developed using high resolution digital cameras of 2 mega-pixels or more. On the other hand, most devices are less than 300 kilo-pixels. Moreover, because 100 kilo-pixels devices are used widely, the environment for image processing is very poor. In this study, very low resolution ($240{\times}320$ = 76,800 pixels) images were adapted when it is difficult to detect cracks. Considering that the images of sewers in South Korea have very low resolution, this study selected low resolution images to be investigated. An automatic crack detection technique was studied using digital image processing technology for low resolution images of sewage pipelines. The authors developed a program to automatically detect cracks as 6 steps based on the MATLAB functions. In this study, the second step covers an algorithm developed to find the optimal threshold value, and the fifth step deals with an algorithm to determine cracks. In step 2, Otsu's threshold for images with a white caption was higher than that for an image without caption. Therefore, the optimal threshold was found by decreasing the Otsu threshold by 0.01 from the beginning. Step 5 presents an algorithm that detects cracks by judging that the length is 10 mm (40 pixels) or more and the width is 1 mm (4 pixels) or more. As a result, the crack detection performance was good despite the very low-resolution images.

Material Properties of Ultra Rapid Hardening Mortar for Repairing Sewage Treatment Concrete Pipes (콘크리트 하수관거 보수용 초속경 수중불분리 모르타르의 재료적 특성)

  • Lee, Byungjae;Lee, Sunmok;Bang, Jin-wook;Kim, Yun-yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • Among the sewage pipes installed in Korea, the length of concrete pipes exceeding 20 years is 66,334 km (42.5%). Deteriorated concrete sewer pipes need to be repaired due to the leakage of internal sewage, which causes problems such as sink holes by expanding the cavity around the pipeline. In this study, we tried to apply anti-washout underwater mortar with ultra rapid hardening cement and segregation reducing agent to sewage pipe repair. As a result of the setting time test, the final set time was delayed by up to 172% by incorporating segregation reducing agent. In the test for measuring the degree of mortar segregation in water, it was measured at pH 12 or less under all mixing conditions. In addition, the suspension amount was measured to be 50 mg / l or less to satisfy the KCI-AD102 standard by incorporating a segregation reducing agent. In terms of the average value of mortar compressive strength, by incorporating segregation reducing agent, the strength of the specimens produced in air was more than 80% of that of the specimens produced in water. Conversely, the bond strengths of the specimens produced in water were measured to be higher than those of the specimens produced in air. Water resistance was evaluated by measuring water absorption and water permeability. Water absorption and water permeability were reduced by 42.6% and 36.6%, respectively, by mixing segregation reducing agent.

A study on the correction of the connection part of the underground facility 3D model and the correction of irregularities (지하시설물 3차원 모델 연결부 보정 및 요철보정에 관한 연구)

  • Kim, Sung Su;Han, Kyu Won;Heo, Sung Seo;Han, Sang Hoon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.429-435
    • /
    • 2021
  • The integrated underground space map shows the underground facility(water supply, sewage, gas, electric power, communication, heating), underground structures (subway, underpass, underground walkway, underground parking lot, underground shopping mall, common ward), ground(drilling, coffin, geology) refers to a map constructed so that a total of 15 types of underground information can be checked at a glance on a three-dimensional basis. The purpose of this study is to develop a technology to correct the problem of curved surface processing and the unevenness of underground facility pipelines that occur in converting 2D underground facility data into 3D-based underground space integrated map(3D underground facility model). do it with. To this end, we first investigated and reviewed the domestic and foreign status of technologies that generate data on underground facilities based on three dimensions, and developed a surface correction algorithm and an unevenness correction algorithm to solve practical problems. Algorithms to verify the developed algorithm This applied correction program was developed. Based on the above process, the three-dimensional model of the underground facility could be produced identically to reality. This study is judged to have significance as a basic study to improve the utilization of the underground spatial integration map.

Classification and Installation Cases of Small Hydraulic Turbine (소수력용 수차의 종류 및 설치 예)

  • Choi, Young-Do;Kim, You-Taek;Lee, Young-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.503-506
    • /
    • 2006
  • Recently, small hydropower attracts attention because of its clean renewable and abundant energy resources to develop. However, suitable turbine type is not normalized yet in the range of small hydropower and it is necessary to study for the effect ive turbine type. Moreover, relatively high manufacturing cost by the complex structure of the turbine is the highest barrier for developing the small hydropower turbine. Therefore, this study is trying not only, to classify the type of current operating turbines installed in the domestic power plants and turbines supplied in Japan by Japanese manufacturer but also, to examine the practical turbine type and installation site to extract the small hydropower energy effectively.

  • PDF

Assessment of the Struvite Crystallization Process for Phosphate Removal and Recovery from a Sludge Treatment System of a Domestic Wastewater Treatment Plant (하수처리장 슬러지처리 계통에서의 인 제거 및 회수를 위한 Struvite 결정화 공정 적용성 평가)

  • Baek, Seung Ryong;Lee, Byung Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.8
    • /
    • pp.462-469
    • /
    • 2017
  • Eutrophication and shortage of phosphate ore raise the necessity of phosphate removal and recovery from wastewater treatment plants. Especially, a sludge treatment system containing highly concentrated phosphate should be targeted for phosphate removal and recovery. This study thus aimed to evaluate the capability of the struvite crystallization process for phosphate removal and recovery from a sludge treatment system of a wastewater treatment plant. Analysis on phosphate concentrations and masses in the sludge treatment system revealed that digested sludge and centrate have phosphate concentrations and masses, high enough to adopt the struvite crystallization process. Chemical equilibrium modeling indicated that the struvite crystallization reaction substantially occurred with pH higher than 8 and $Mg^{2+}$ concentration 1.2 times higher than its theoretical requirement. A series of batch tests with digested sludge and centrate indicated that the phosphate removal reaction by struvite crystallization followed a first-order kinetics and reached over 80% removal efficiency at equilibrium. Aeration in the batch tests was found to purge $CO_2$ in sludge or centrate and increase pH up to 8.7, without adding NaOH. Thus, we concluded that the struvite crystallization process could be an efficient and economical process for phosphate removal and recovery from a wastewater treatment plant.