• Title/Summary/Keyword: 하부구조 강성

Search Result 127, Processing Time 0.065 seconds

Effect of the Member Joint on Structural Performance of an Arch-type Multi-span Greenhouse: A Full-scale Experimental and Numerical Study (부재 접합부가 아치형 연동온실의 구조 성능에 미치는 영향: 실대형 실험적 및 해석적 연구)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.402-410
    • /
    • 2017
  • The effect of the steel pipe member joint on the design performance of a plastic multi-span greenhouse was analysed through the comparing full-scale experiment and numerical analysis. The design performance of the greenhouse is generally evaluated through numerical analysis, but it is rare to consider the characteristics of the connections or joints of the members. In this study, the effect of the column-gutter beam-rafter-wind break wall joint on the design performance of the whole structure of a plastic multi-span greenhouse was analysed. The numerical results with assuming that the member joint are rigid condition were compared with the full-scale load test results using member joints used in the field. The stiffness of the entire structure was compared using the load-displacement relationship and the change of the load sharing ratio that the main members such as column, rafters, and wind break wall was analysed. The results of the load test were about 40% larger than the numerical result and the member stress was more than twice as large as those of the loaded columns. In order to increase the reliability of the design performance of the greenhouse, it is necessary to develop a numerical analysis model which can consider the characteristics of various joints.

Vibrational Analysis of Slab Tracks Considering Wheel-Rail Interaction (차륜-레인 상호작용을 고려한 슬래브 궤도의 진동해석)

  • 이희현
    • Computational Structural Engineering
    • /
    • v.7 no.2
    • /
    • pp.77-87
    • /
    • 1994
  • Vibrational analysis of slab tracks for HSR(High Speed Rail) is performed in order to find dynamic characteristics and to control noise and vibration for the tracks. Wheel-rail interactive force is included in the analysis by modelling the vehicle and track as an unsprung mass and elastically-supported-double-beam respectively, and both are assumed to be connected by the Hertzian spring. From this study, it has been found that vibration in the track and the force transmitted to the infrastructure could be reduced by controlling elasticity, mass and stiffness of the track supporting system appropriately.

  • PDF

An Evaluation and Response Analysis of Hybrid Building System by Introducing Haunch at the Transfer fool (주상복합건물 전이층의 거동 분석과 헌치의 적용성 평가)

  • 장성훈;김희철;홍원기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.1
    • /
    • pp.63-72
    • /
    • 2001
  • 상부 벽체와 하부 골조로 구성되는 주상복합건물은 전이층에서 수직적인 강성과 강도의 불연속성을 갖는다. 이러한 복합구조는 전이층에서 춤이 큰 보에 의하여 하중이 전달되면 설계시 매우 중요하게 고려하여야 하는 사항이다. 그러나 이에 대한 연구가 충분히 이루어져 있지 않으며 실제 전이보의 설계시 춤을 매우 크게 하여 요구되는 강도보다 큰 안전율이 고려되고 있다. 본 연구에서는 전이층의 단순화모델을 이용하여 보의 높이 및 지지면의 길이에 따른 아치거동의 변화를 조사하였다. 유한요소법을 이용하여 구조물을 분석하고 두 변수를 포함하는 헌치부재를 이용하여 그 효과를 기존 시스템과 비교하였다. 중요 변수와 헌치의 기울기는 1:1의 비율에서 사장 효율이 좋은 것으로 나타났으며, 이러한 결과를 전이보를 대신하여 사용한 결과 중력방향의 상부 아치거동에 대하여 효과적으로 작용하는 것으로 나타났다. 또한 응력 집중부위에서의 응력 감소와 깊이 전이보의 높이감소에 효과적으로 작용하는 것으로 나타났다.

  • PDF

A Study on the Durability Improvement of Movable Bracket Structures (가동 브라킷 구조물의 내구 성능 향상 방안 연구)

  • Park, Yong-Suk;Seo, Jeong-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1117-1121
    • /
    • 2011
  • The movable bracket structure, which is an apparatus for supplying electric power to a running electric locomotive, is applied by a repeated load during the passage of the electric locomotive. Such a repeated load becomes an excitation source that causes screws constituting the movable bracket structure to be loosened. This study was conducted on the causes and countermeasures of the bolt loosening caused by the repeated vibration using a computer simulation. As the result, a simulation model was constructed to enable the dynamic analysis of the movable bracket structure. It could be found that the principal excitation frequency range for the bolt loosening of the movable bracket structure was less than 200 Hz. In addition, the bolts are prevented from being loosened by increasing stiffness of H beams. The vibration mode of a lower band bracket is found to be triggered in a frequency range between 300 and 600 Hz. And the increase in stiffness of the lower band bracket exhibits the effect to avoid the bolt loosening at a frequency range of 200 Hz or more.

Oil Leakage Prediction through Cut Part of Double Elastomeric Seal (이중 탄성중합체 시일의 절단부 오일누유 예측)

  • Taek-Sung Lee;Yeon-Hi Kim
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.3
    • /
    • pp.165-171
    • /
    • 2023
  • The rotary joint connecting the upper and lower structures of construction machinery and special vehicles transmits hydraulic pressure as the shaft and housing rotate, and multiple seals are assembled to prevent oil leakage into the oil flow channel. Because the seal material is rigid and difficult to assemble, we sought a method to assemble it after cutting. The shapes of the cutting surface are L-shaped and / shaped, and the leakage standard when hydraulic pressure is applied is the contact pressure generated on the cutting surface. The structure and material of the seal are composed of a double elastomer, and nonlinear contact structural analysis is performed when only the high-rigidity PE material is cut. Studies have shown that the shorter the cutting length, the better the leakage prevention and the higher the possibility of leakage to the bottom surface where NBR and PE come into contact rather than the top surface where the PE and the housing come into contact.

Structural Performance of the RC Boundary Beam-Wall System Subjected to Axial Loads (축하중이 작용하는 철근 콘크리트 경계보-벽체 시스템의 압축성능 평가)

  • Han, Jin-Ju;Son, Hong-Jun;Kim, Dae-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.1
    • /
    • pp.57-64
    • /
    • 2022
  • This study investigated the structural performance of the RC boundary beam-wall system subjected to axial loads that required lesser construction quantity and smaller floor height in comparison with the conventional RC transfer girder system. Four specimens of 1/2 scale were constructed, and their peak strengths under axial loads and failure characteristics were compared and analyzed. Test parameters included the ratio of the lower to the upper wall length, lower wall thickness, and stirrup details of the lower wall. In addition, three-dimensional nonlinear finite element analysis was performed to verify the effectiveness of the boundary beam-wall system. The peak strength of each specimen was similar to the nominal axial strength of the lower wall, indicating that the axial load was transferred smoothly from the upper to the lower wall. The contribution of the lower wall cross-section was high if the ratio of the lower to the upper wall length was small; the contribution was low if the out-of-plane eccentricity existed in the lower wall. The specimen with smaller stirrup distance and cross-ties in the lower wall showed higher initial stiffness and peak load than other specimens.

Monotonic and Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Top-Seat Angle (상·하부 ㄱ형강 반강접 CFT 기둥-보 접합부의 단조 및 이력거동)

  • Lee, Sung Ju;Kim, Joo Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.3
    • /
    • pp.191-204
    • /
    • 2014
  • In this paper a systematic numerical analysis is performed to obtain the bending moment resisting capacity of a top and seat angle connection, which is a type of partially restrained connection, for a CFT composite frame subjected to cyclic loading. This partially restrained composite CFT connections are fabricated using high strength steel connection bar. The three-dimensional nonlinear finite element models are constructed to investigate the rotational stiffness, bending moment capacity, and failure modes. A wide scope of additional structural behaviors explain the different influences of the top and seat angle connection's parameters, such as the different thickness of connection angles and the gage distances of the high strength steel bar. The moment-rotation angle relationships obtained from the finite element analysis are compared with those from Richard's theoretical equation.

Evaluation on Behavioral Characteristics of PSC Integral Abutment Bridge (PSC 일체식 교대 교량의 거동특성 평가)

  • Ahn, Jin-Hee;Yoon, Ji-Hyun;Kim, Sang-Hyo;Kim, Jun-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4A
    • /
    • pp.361-373
    • /
    • 2010
  • Bridges constructed without any expansion joint or bridge bearing are called integral abutment bridges. They integrate the substructure and the superstructure. Possible deformation of the superstructure, due to changes in temperature for example, is prevented by the bending of the piles placed at the lower part of the abutment. This study examines the behavior of integral abutment bridges through soil-pile interaction modeling method and proposes an appropriate modeling method. Also, it assesses the behavior characteristics of the superstructure and piles of integral abutment bridges through parametric study. Soil condition around the pile, abutment height, and pile length were selected as parameters to be analyzed. Structural analysis was conducted while considering the interactions of soil-pile and temperature change-earth pressure on the abutment. Comparative behavior analysis through soil-pile interaction modeling showed that elastic soil spring method is more appropriate in evaluating the behavior of integral abutment bridges. The parametric study showed the tendency that as the soil stiffness around the pile increases, the moment imposed on the superstructure increases, and the displacement of the piles decreases. In addition, it was observed that as the bridge height increases, the earth pressure on the abutment increases and that in turn affects the behavior of the superstructure and piles. Also, as the length of the pile increased, the integral bridge showed more flexible behavior.

Analysis and Prediction for Abutment Behavior of Prestressed Concrete Girder Integral Abutment Bridges (프리스트레스트 콘크리트 거더 일체식 교량의 교대 거동 해석과 예측)

  • Kim, Woo-Seok
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.667-674
    • /
    • 2011
  • This paper discusses the analysis method of prestressed concrete girder integral abutment bridges for a 75-year bridge life and the development of prediction models for abutment displacements under thermal loading due to annual temperature fluctuation and time-dependent loading. The developed nonlinear numerical modeling methodologies considered soil-structure interaction between supporting piles and surrounding soils and between abutment and backfills. Material nonlinearity was also considered to simulate differential rotation in construction joints between abutment and backwall. Based on the numerical modeling methodologies, a parametric study of 243 analysis cases, considering five parameters: (1) thermal expansion coefficient, (2) bridge length, (3) backfill height, (4) backfill stiffness, and (5) pile soil stiffness, was performed to established prediction models for abutment displacements over a bridge life. The parametric study results revealed that thermal expansion coefficient, bridge length, and pile-soil stiffness significantly influenced the abutment displacement. Bridge length parameter significantly influenced the abutment top displacement at the centroid of the superstructure, which is similar to the free expansion analysis results. Developed prediction model can be used for a preliminary design of integral abutment bridges.

Effect of Bedding Conditions on Earth Pressure Distribution of Embedded Pipes (EPS베딩재가 지중매설관의 토압에 미치는 영향)

  • Yoo, Nam-Jae;Lee, Hee-Kwang;Park, Byung-Soo;Jeong, Gil-Soo;Sim, Do-Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.6
    • /
    • pp.121-130
    • /
    • 2007
  • In this paper, large scale experimental model tests were performed to investigate the distribution of earth pressure acting on embedded rigid pipes having different bedding conditions. For these tests, very light weighted EPS blocks were installed at top and bottom of the rigid pipe and Jumunjin Standard Sand was used as a ground material. As results of model tests, for the case of no bedding on the pipe, the measured pressure at the bottom of the pipe was $4.96_{tf/m^2}$ whereas they were in the range of $1.87{\sim}4.96_{tf/m^2}$ in the case of EPS beddings being installed at the top and the bottom of the pipe. Therefore, for the case of EPS bedding being installed, the ratio of reduced pressures acting on the pipe, compared with the case of no EPS beddings, were in the rage of 16~62%. As a result of parametric test with changing the locations of EPS bedding, the trend of reducing the stress acting on the pipe was in the order of bottom bedding, top bedding, and top and bottom bedding. Effect of bedding positions on the reduced magnitude of acting pressure on the pipe was more significant in the case of top bedding than in the case of the bottom bedding.