• Title/Summary/Keyword: 필요환기량

Search Result 107, Processing Time 0.028 seconds

Source Emission Rate on Air Pollutants from Portable Gas Range and Optimal Ventilation Rate in Indoor Environment (휴대용 가스렌지 연소에 의한 공기오염물질의 발생량 및 실내환경의 필요 환기량)

  • Yim, Sung-Kuk;Kim, Young-Hee;Yang, Won-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.2 s.95
    • /
    • pp.92-97
    • /
    • 2007
  • A series of source tests were conducted to characterize emissions of nitrogen oxide(NOx, NO, $NO_2$), carbon mon oxide(CO), carbon dioxide$(CO_2)$ and total VOCs from portable combustion devices in steady-state using well-mixed chamber. Since use of portable gas range is widespread in houses and restaurants in Korea, it is important to characterize the emission of air pollutants and suggest optimum ventilation rate. Ranges of emission rates of air pollutants from portable gas ranges were $NO \;0.551\sim0.939mg/hr,\;NO_2\;0.354\sim1.080mg/hr,\;NO_x\;1.207\sim1.631mg/hr,\;CO\;1.389\sim4.21mg/hr,\;CO_2\;2426.823\sim2973.495mg/hr$, and VOCs $0\sim0.119mg/h$. Mean of personal exposure and indoor environment level of $NO_2$ by combustion of portable gas range were 74.7 ppb and 65.4 ppb, respectively, suggesting persons using portable gas range in houses and restaurants might be highly exposed. Required ventilation rate to control the air pollutants emitted from portable gas range was maximumly $3.131m^3/hr$ on the basis of $NO_2$ indoor air quality standard.

A Study on Measurement of the Indoor Air Quality in Modular Mock-up Housing (모듈러 목업주택의 실내공기질 실측조사 연구)

  • Chun, Chu-Young;Kim, Jong-Yeob;Bang, Jong-Dae;Kim, Gap-Deug
    • Land and Housing Review
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 2015
  • Recently, It has been much interest in modular housing construction. so, The purpose of this study was to investigate the characteristics of the indoor air quality in modular mock-up housing. We measured indoor air quality(formaldehyde, benzene, toluene, ethylbenzene, xylene, styrene) of two modular mock-up units that built-in furniture is installed and uninstalled. As a result, the pollutants of built-in furniture installed unit were emitted more than built-in furniture uninstalled unit. But after bake-out and ventilation, emission concentrations of two modular mock-up units were similar and were below Indoor Air Quality recommendation standards. Built-in furniture is likely to affect the emission concentration of toluene

우리 나라 가축분뇨의 처리기술 현황

  • 최홍림
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.2
    • /
    • pp.18-28
    • /
    • 1998
  • 현재의 가축분뇨처리 형태와 축종별 적용대상은 표 3과 같이 분류되며, 축분 퇴비화 뇨오수 정화방식의 고액분리 형태에서 분뇨혼합물의 동시처리 즉, 깔감축사(소, 돼지), 슬러리 발효 퇴비화를 통한 무방류 시스템으로 변화되는 추세이다. 이러한 현상은 최근의 방류수질 규제강화에 따른 무방류화 저비용 단순화를 지향하고 있으며, 무방류화의 가장 큰 걸림돌은 톱밥과 같은 수분조절재 부족이라 할 수 있다. 현재 이용되고 있는 주요 시스템별 개선안은 다음과 같다. $\square$ 주요 처리 시스템 적용의 문제제기 $\circ$ 축분발효시설 - 톱밥 등 부자재 무이용을 위한 축분의 예비 건조시설 이용 - 교반식 발효기의 악취확산방지를 위하여 밀폐형 하우스 및 강제환기 장치 설치에 의한 악취 포집 및 탈취 - 중소규모 발효시설 개발 $\circ$ 화력건조 - 예비건조를 통한 톱밥, 연료비용 절감 - 악취방치 장치부착 의무화 $\circ$ 활성오니 정화시설 - 시설 운전관리 단순화 - 1차 고액분리를 통한 유입수 오염부하량 감소 및 균일화 $\circ$ 깔감축사 - 경제적으로 흡수를 극대화할 수 있는 수분조절재의 조합비 결정 및 혼합물을 깔감으로 재이용 기술개발 $\circ$ 슬러리 발효퇴비화 시설 - 톱밥 등 수분조절재 사용량 절감기술 - 증발량 극대화 기술개발 및 소요에너지 최소화기술개발 우리나라는 사계절이 뚜렷하여 외기상에 따라 편차가 심하며, 고밀도 사육 및 지역적 편중성, 경지면적 협소, 고비용 시장구조 등의 축산환경을 고려한다면 근원적으로 가축분뇨문제 해결한다는 것은 결코 쉬운 일이 아니다. 이는 저공해 사료개발에서부터 분뇨가 발생단계에서 분리, 수거할 수 있는 수거시설, 고효율 분뇨처리시스템의 정립, 액비 및 퇴비의 가공, 토양환원되었을 때 작물생장장애, 액비, 퇴비의 유통, 가축분뇨처리 정책 및 규제법 등의 각 분야에서 복합적 노력이 필요하다.

  • PDF

Thermal Performance Evaluation of a Test Cell Thru Short Term Measurements (TEST CELL에서 단기측정에 의한 열성능 평가)

  • Jeon, M.S.;Yoon, H.K.;Chun, W.G.;Jeon, H.S.
    • Solar Energy
    • /
    • v.10 no.2
    • /
    • pp.10-17
    • /
    • 1990
  • Short-term tests were conducted on a house at KIER, Daejon for its thermal performance evaluation. The test procedure and data analysis were made according to the PSTAR method. Each test period was 3 days during which the building was unoccupied. The data measured with 8 channels were used to renormalize an audit based simulation model of the house. The following are the key parameters obtained in the present analysis: 1) the building loss coefficient(skin conductance plus infiltration conductance during coheating period); 2) the effective building heat capacity; and 3) the effective solar gain. An estimation of total heat required to maintain a standard level of comfort during a typical winter season is also calculated on the basis of the renormalized simulation model and typical long term weather data.

  • PDF

The Effects of High-Intensity Aerobic Interval Training In The Elderly With Myocardial Infarction (노인 심근경색 환자에서 고강도 간헐적 유산소운동의 효과)

  • Kim, Ji Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.267-274
    • /
    • 2019
  • To investigate the effect of high-intensity interval training (HIIT) on the outcomes of cardiac rehabilitation(CR) in elderly and younger patients with myocardial infarction(MI). Of the MI patients who received hospital-based CR from 2015 to 2017, we retrospectively reviewed the medical records of the patients who continued follow-up through the outpatient clinic. A total of 39 patients (20 elderly patients (${\geq}60year$($64.1{\pm}3.6$)) and 19 younger patients (< 60 year($55.6{\pm}2.3$)) was included in this study. The HIIT program was composed of 10 minutes of warm-up, 30 minutes of interval aerobic exercise, and 10 minutes of cool down. The aerobic exercise based on their initial exercise tolerance test outcome consisted of 3-minute usual intensity phase (60-70% of heart rate/VO2 reserve) and 4-minute of high-intensity phase (70-90% of heart rate/VO2 reserve). Exercise capacity was measured by exercise tests before and after hospital- based CR. Before CR, elderly group had a significantly lower exercise capacity in Exercise time, peak VO2, METs, Anaerobic threshold, VEmax, 02pulse than younger group. Both group showed similar improvement of cardiopulmonary exercise capacity after CR. And HIIT is safe and effective in elderly patients. It is considered necessary to further expansion for the participation of high intensity interval training in elderly patients.

The Effect of Bag-Valve Mask Using Skill Education with Flowmeter

  • An, Juyeong;Kim, Hwan-Hui;Yun, Hyeong-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.11
    • /
    • pp.219-229
    • /
    • 2022
  • This study is to evaluate the intervention effect using a flowmeter in bag-valve mask skill education. The purpose of this study was to compare the accuracy of bag-valve mask skill between intervention group with flowmeter and control group without flowmeter, understand the improvement effect of skill education of bag-valve mask, and provide basic data to suggest the method of skill education. The total number of subjects of this study was 60, with 30 intervention group and 30 control group. In comparison of the optimal number of normal tidal volume range at pre-test and post-test, the normal range percentages of the intervention group before and after education were 32.8% and 86.7%, respectively, and there was a significant difference(p<0.01). The normal range percentages of the control group before and after education were 20.0% and 34.7%, respectively, and there was a significant difference(p<0.05). To evaluate the factors associated with good performance of bag-valve mask skill of the subjects including the normal range of tidal volume, the logistic regression analysis has been performed, and the significant influential factors were gender(10.305, 1.20-87.98), educational experience of field practice(31.674, 1.25-805.16), and intervention(92.750, 4.58-1879.69). Through this study, it was confirmed that the intervention using flowmeter for the skill education of bag-valve mask was effective, and it is necessary to consider reflecting it in the education of students majoring in emergency medical technology in the future.

Effects of Cardiac Rehabilitation in Elderly Patients After Myocardial Infarction (노인 심근경색 환자에서의 심장재활의 효과)

  • KIM, JI HEE
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.464-471
    • /
    • 2016
  • To investigate the effects of cardiac rehabilitation (CR) on cardiopulmonary exercise capacity in both elderly and younger patients with myocardial infarction (MI). Of the MI patients who received hospital-based CR between February 2012 and December 2015, we retrospectively reviewed the medical records of patients who continued a follow-up through the outpatient clinic. A total of 46 patients (18 elderly patients (${\geq}60years$) and 28 younger patient (< 60)) were included in this study. The subjects visited the clinic to perform aerobic exercises with ECG monitoring based on their initial exercise tolerance test outcome. The exercise capacity was measured by symptom-limited exercise tests before and after hospital-based CR. Before CR, the elderly group had a significantly lower exercise capacity in peak VO2, METs, anaerobic threshold, exercise time, respiratory exchange ratio (RER) than the younger group. After CR, elderly groups showed a significantly improved exercise capacity in exercise time, HRmax, HRrest, peak VO2, METs, anaerobic threshold, and RER. Both elderly and younger groups showed similar improvement of cardiopulmonary exercise capacity after hospital-based CR. There is a very low cardiac rehabilitation participation and referral rates with MI patients in Korea. It is considered necessary to further expand the participation of cardiac rehabilitation in elderly MI patients.

Estimation of Heat Insulation and Light Transmission Performance According to Covering Methods of Plastic Greenhouses (플라스틱온실의 피복방식에 따른 보온 및 광투과 성능 평가)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won;Diop, Souleymane
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.270-278
    • /
    • 2013
  • The objective of the present study is to provide data needed to decide covering method to be able to increase the thermal insulation and light transmittance efficiency of commercial greenhouse. The thermal insulation effect, PPF transmittance and quantity of condensation water were estimated in experimental tomato greenhouses covered with three types of coverings of single layer, air inflated and conventional double layers covering. The overall heat flow of air inflated double layers greenhouse was similar to that of conventional double layers greenhouse, but the temperature between covering material and thermal screen in air inflated double layers greenhouse was lower than that in conventional double layers greenhouse at the same outside temperature condition due to air leakage through the gap of roof vent. The overall heat transfer coefficients acquired by experiment that was performed in single layer and conventional double layers greenhouses were close to those obtained from model experiment. Even though the PPF transmittance of air inflated double layers greenhouse was lower than that of single layer greenhouse, which was greater than that of conventional double layers greenhouse. The quantity of condensation water on covering surface of single layer greenhouse was greater than that of air inflated double layers greenhouse due to lower covering surface temperature.

Sick Building Syndrome in 130 Underground Workers (지하상가 근무자의 건강 장애에 관한 실태조사)

  • Joo, Ree;SaKong, Joon;Chung, Jong-Hak;Park, Sang-Whan;Kim, Dong-Hee;Kim, Dong-Min;Choi, Eun-Kyong;Cho, Hyun-Geon
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.325-340
    • /
    • 1998
  • A cross-sectional study was conducted to evaluate the relationship between sick building syndrome(SBS) and the environmental factors affecting SBS on 130 underground workers and 60 controls. The study consisted of 1) a review of environmental condition 2) measurement of temperature, $O_2$, $CO_2$, CO, and formaldehyde and 3) a questionnaire survey of symptom prevalence and perception of environmental conditions using indoor Air Quality questionnaire recommended by National Institute for Occupational Safety and Health. Bronchitis and dust allergy were more prevalent in underground workers significantly(p < 0.05). Among the 18 symptoms related to the indoor air pollution, the experience rate of dry, itching or irritated eyes, sore or dry throat, chest tightness, tired or strained eyes and dry or itchy skin symptom was significantly different between the underground workers and controls. The diagnostic criteria of SBS was defined as at least 1 symptom is experienced 1-3 times a week during the last 1 month among 18 indoor air pollution related symptoms which can be relieved by moving out of the underground. Applying the criteria, the mean symptom score was significant higher in underground workers than controls significantly (p < 0.05). These resalts indicated that underground workers are under inappropriate ergonomic and physical condition and inadequate ventilation. Their experience rate of symptoms related to indoor air pollution and prevalence of SBS was significantly higher than controls. To reduce the prevalence of SBS of underground workers, the surveillance system of indoor air quality, restriction of using fuel in underground and legislative regulations for the environment are needed to establish a better indoor air quality. Early detection, treatment and prevention of SBS through medical attention is also needed.

  • PDF

Hydrogen Compressor Cycle Analysis for the Operating Pressure of 50 MPa and High Charging Capacity (50 MPa급 대용량 수소압축기 사이클 해석)

  • Song, Byung-Hee;Myoung, No-Seuk;Jang, Seon-Jun;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.66-73
    • /
    • 2020
  • In the hydrogen compression cycle, which is currently being developed, hydrogen is compressed to a very high pressure using a compressor, and then stored and used in a high-pressure vessel. This shows that an increase in the temperature of hydrogen in the vessel due to a pressure rise during the filling process and the pressure fatigue due to the repeated cycle may cause problems in the reliability of the vessel. In this paper, for the entire processes in a 50 MPa hydrogen compression system, theoretical and numerical methods were conducted to analyze the following: the temperature increase of hydrogen in the vessel and the time required to reach thermal equilibrium with the surroundings, the change in temperature of hydrogen passing through the pressure reducing valve, and the required capacity of the heat exchanger for cooling the vessel. The results will be useful for the design and construction of hydrogen compression systems, such as hydrogen charging stations.